• Title/Summary/Keyword: Sensitivity Axis

Search Result 217, Processing Time 0.025 seconds

Golf Swing Diagnosis Equipment based on MEMS Inertial Sensors (초소형 관성센서를 이용한 골프스윙진단장치)

  • Song, Ci-Moo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1761-1766
    • /
    • 2008
  • This paper deals with a novel autocalibration method of three-axis micromachined accelerometers applied to a new golf swing diagnosis equipment for golfers. This diagnosis equipment can help golfers monitor and anlalyze their swing posture and therefore modify their swing action to get better score and enjoy their lives through golf. The micromachined accelerometers to get information of the motion are the essential part of the putting club to measure the three-axis acceleration as accurately as possible. This paper presents an efficient autocalibration algorithm to find the offset and sensitivity of accelerometers by only using the static measurement data at six different positions. The experimetnal results on the developed putters show the validity of the proposed algorithm for the new smart putter.

  • PDF

The torque distribution algorithm of driving wheels using 2D joystick in the electric wheel-chair (2D 조이스틱에 기반한 전동휠체어의 토크 분배 알고리즘)

  • Park, Sung-Jun;Park, Je-Wook;Kim, Jang-mok
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.212-213
    • /
    • 2013
  • This paper proposes the algorithm of torque distribution in the electric wheel-chair using 2D joystick for drive safety. For the accurate driving performance, the specific and precise torque distribution is required in both wheels depending on signals of X-Y axis that is generated from 2D joystick. The signals of X-Y axis from joystick are transformed into the propulsion force and the torque reference. And the torque reference can be generated through the dynamic model of wheel-chair. The optimal dynamic characteristics of the electric powered wheelchair can be obtained, by adjusting the sensitivity coefficients of propulsion force and torque reference, In addition, the system takes smooth and stable control characteristics due to continuous torque output at all directions of joystick. The several simulations verify the usefulness of the proposed algorithm about torque distribution.

  • PDF

A Two Dimensional Digital Clinometer with Dual Axis Micromachined Accelerometers (2축 MEMS 가속도 센서를 이용한 2차원 디지털 경사계)

  • Song, Ci-Moo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.10
    • /
    • pp.499-503
    • /
    • 2006
  • This paper deals with a new two dimensional clinometer based on dual axis micromachined accelerometers. The clinometer is a small and low-cost product, which is mainly developed to help golfers read easily the tilt of a putting green. First, this paper proposes the principle of two dimensional clinometer and also a calibration method with respect to the offset voltage and sensitivity of a accelerometer. Experimental results on the developed clinometer show that the proposed clinometer can provide useful information on the tilt angle and direction of an inclined plane.

Development of Micro-opto-mechanical Accelerometer using Optical fiber (광섬유를 이용한 미세 광 기계식 가속도 센서의 개발)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.93-99
    • /
    • 2011
  • This paper presents a new type of optical silicon accelerometer using deep reactive ion etching (DRIE) and micro-stereolithography technology. Optical silicon accelerometer is based on a mass suspended by four vertical beams. A vertical shutter at the end of the mass can only moves along the sensing axis in the optical path between two single-mode optical fibers. The shutter modulates intensity of light from a laser diode reaching a photo detector. With the DRIE technique for (100) silicon, it is possible to etch a vertical shutter and beam. This ensures low sensitivity to accelerations that are not along the sensing axis. The microstructure for sensor packaging and optical fiber fixing was fabricated using micro stereolithography technology. Designed sensors are two types and each resonant frequency is about 15 kHz and 5 kHz.

Analysis of Measured Azimuth Error on Sensitivity Calibration Routine (Sensitivity Calibration 루틴 수행시 Tilt에 의한 방위각 측정 오차의 분석)

  • Woo, Kwang-Joon;Kang, Su-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • The accuracy of MR sensor-based electronic compass is influenced by the temperature drift and DC offset of the MR sensor and the OP-amp, the magnetic distortion of nearby magnetic materials, and the compass tilt We design the 3-axis MR sensor and accelerometers-based electronic compass which is compensated by the set/reset pulse switching method on the temperature drift and DC offset, by the execution of hard-iron calibration routine on the magnetic distortion, and by the execution of the Euler rotational equation on the compass tilt. We qualitatively analyze the measured azimuth error on the execution of sensitivity calibration routine which is the normalization process on the different sensitivity of each MR sensor and the different gain of each op-amps. This compensation and analytic result make us design the one degree accuracy electronic compass.

A Novel Visual Servoing Method Using QR Decomposition and Disturbance Observer (QR분해와 외란관측기를 이용한 시각구동 방법)

  • 이준수;서일홍;유범재;오상록
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.6
    • /
    • pp.462-470
    • /
    • 2000
  • This paper proposes a visual servoing method based on QR decomposition and disturbance observer. The QR decomposition factors the image feature Jacobian into a unitary matrix and an upper triangular matrix. And it is shown that several performance indices such as measurement sensitivity of visual features, sensitivity of the control to noise and controllability can be improved for any general image feature Jacobian by QR decomposition and disturbance observer. To show the validity of the proposed approach, visual servoing with stereo vision is carried out for a Samsung FARAMAN 6-axis industrial robot manipulator.

  • PDF

Null lens design for testing of elliptical surface (타원면경 측정 Null 렌즈 설계)

  • 김연수
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.246-249
    • /
    • 2000
  • The null lens is designed for testing the elliptical (conic constant>O) mirror which is the third mirror of the off-axis Three Mirror Anastigmat (TMA) designed as a high resolution camera for remote sensing. The mixed type design is proposed as a new design type which has a small annular flat mirror, but has as twice sensitivity as the autostigmatic type design. It is also shown that the null lens of the Mixed type is better than that of the autostigmatic type in terms of the sensitivity of the wavefront distortion which is given as the magnitude of optical path difference with respect to the change of each surface parameters such as the radius of curvature, thickness of lenses and tested mirror.

  • PDF

Experiments on a Visual Servoing Approach using Disturbance Observer (외란 관측기를 이용한 시각구동 방법의 구현)

  • Lee, Joon-Soo;Suh, Il-Hong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1311-1316
    • /
    • 1999
  • A visual servoing method has been proposed based on disturbance observer to eliminate the effect of the off-diagonal component of image feature Jacobian, since performance indices such as measurement sensitivity of visual features, sensitivity of the control to noise and controllability could be improved when an image feature Jacobian was given as a block diagonal matrix. In this paper, experimental results of disturbance observer-based visual servoing are discussed where Samsung FARAMAN-AS1 6-axis industrial robot manipulator is employed. Also, the feature saturator is proposed to stabilize the disturbance observer loop by saturating the differential changes of the image features.

  • PDF

Evaluation and Analysis of Dynamic Characteristics in Tilt Actuator for High Density Optical Storage Devices (고밀도 광저장 기기용 틸트 액추에이터 동특성 분석 및 평가)

  • 김석중;이용훈;최한국
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.584-595
    • /
    • 2000
  • We design a new actuator for high density optical device in order to control the radial tilting motion. The newly designed actuator makes it possible to control the tilting motion actively, while the coventional actuator compress tilting motion with passive spring. First of all, We present 3-dimensional modeling of actuator and accomplish the modal analysis and magnetic analysis of actuator. Due to these results, a new designed actuator has performance of high sensitivity and high second resonance frequency. Secondly, We present the 3-DOF dynamic modeling of the 4-wire spring type actuator. sensitivity analysis is performed to consider the assembling error, such as the difference of mass center and force center. From these results, the sensitivities of rotation due to the assembly error are revealed and design criteria of rotation is presented. And experimental results of a newly designed actuator are presented and compared with theoretical results. Finally, We propose a dynamic tilt compensation and high acceleration actuator for high density optical storage devices.

  • PDF

A Study on Dose Sensitivity according to Position Variance in Extremities Radiation Therapy with Water Bolus (사지의 방사선 치료에 사용하는 water bolus의 적용 시 치료부위의 위치 변화에 따른 방사선 선량분포의 민감도 연구)

  • Seo, Jeong Min
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.199-206
    • /
    • 2015
  • The purpose of this study was to investigate radiation dose sensitivity due to displacement of human extremities in the water bolus box on radiation therapy. Water bolus box and human thigh with femur bone were constructed in computerized radiation therapy planning system to verify the absorbed dose. Two 6MV X-ray beams were irradiated bilaterally into water bolus box and then radiation dose were calculated each situation at displacement of middle axis of thigh from the center in water bolus box to right and left direction. Absorbed dose of thigh and femur bone increased by the distance of displacement. The maximum dose of thigh even increased 20% over than prescribed dose. This is in contrast to conventional concept of dose distribution in water bolus box. Based on this result, displacement of body site in the water bolus box have to be averted during radiation therapy.