• Title/Summary/Keyword: Sensitivity Axis

Search Result 217, Processing Time 0.026 seconds

Telemonitoring System of Fall Detection for the Elderly (노인을 위한 원격 낙상 검출 시스템)

  • Lee, Yong-Gyu;Cheon, Dae-Jin;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.420-427
    • /
    • 2011
  • The population of elderly people increases rapidly as our society moves towards the aged one. Healthcare for the elderly becomes an important issue and falling down is one of the critical problems although not well recognized. In this study, a fall detection system was developed using a 3-axis accelerometer. Analyzing fall patterns, we took into account the degree of impact, posture angle, the repetitions of similar movements and the activities after a potential fall and proposed an algorithm of fall detection. Information of the fall sensor was sent to a remote healthcare server through the wireless networks of Zigbee and WLAN. Our system was designed to monitor multiples users. 12 persons participated in experiment and each one performed 24 different movements. Our proposed algorithm was compared with other reported ones. Our method produced the excellent results having a sensitivity of 96.4 % and a specificity of 100 % whereas other methods had a sensitivity range between 87.5 % and 94.8 % and a specificity range between 63.5 % and 83.3 %.

The Analysis of position Sensitivity and Aberration characteristics of Liquid Crystal Elements (액정 소자의 위치 민감도 및 수차 특성에 대한 연구)

  • Heor Jae-Youn;Yoo Ho-Sik;Yoo Jang-Hoon;Park Soo Han;Jeong Soo-Jin
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.78-83
    • /
    • 2005
  • The Blu-ray disc as a next generation high density optical medium uses an objective lens of high numerical aperture(NA 0.85) and blue laser in order to increase the recording density. The double layer is also useful for doubling the density. The spherical aberration of Blu-ray disc is very sensitive to the thickness of the disk because of high numerical aperture. This paper suggests a method to compensate the spherical aberration caused by the change of disk thickness, by using the Liquid Crystal lens instead of the Liquid Crystal panel. It was possible to develop both the LC panel generating the optical phase difference and LC lens changing the optical power. In this paper, we analyzed the aberration performance and a position sensitivity of the two type LC elements when the samples deviate from the optical axis of the objective lens. The results of applying this analysis show that the LC lenses rather than the LC panels have a significant assembling tolerance. The theoretical characteristics of the two elements are calculated and compared with the measurement data.

  • PDF

Optimized blade of small vertical axis wind turbine and its vortex structure analysis (수직축 풍력 터빈 블레이드의 최적화 설계 및 Vortex 구조 분석)

  • Na, Jisung;Ko, Seungchul;Sun, Sanggyu;Bang, Yusuk;Lee, Joon Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • Sensitivity studies of blade angle and twisted angle are numerically investigated to optimize the Savonius blade. As blade angle increases, the contact area between blade and wind decreases, showing the suppression of the vortex generation near blade. Compared to the blade angle of 0 degree, the blade angle of 20 degree shows about 2.6% increment of power efficiency. Based on the blade angle of 20 degree, sensitivity studies of the twisted angle are performed. The result indicates that the adjustment of the twisted angle causes the torque of blade to increase. Optimized blade can suppress the formation of the vortex structure in rear region. Also, wind flows without disturbance of vortex when passing through the optimized blade. The 1kw vertical wind turbine system with optimized blade can generate 4442.2kWh per year and have 53% capacity factor.

High Sensitivity Micro-fabricated Fluxgate Sensor with a Racetrack Shaped Magnetic Core

  • Choi, Won-Youl;Kim, So-Jung
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.3
    • /
    • pp.110-114
    • /
    • 2005
  • We present a micro fluxgate magnetic sensor having solenoid coils and racetrack shaped magnetic core, which was designed to decrease the .operating power and magnetic flux leakage. Electroplated copper coils of $6\;{\mu}m$ thickness and the core of $3\;{\mu}m$ thickness were separated by benzocyclobutane (BCB) having a high insulation and good planarization characters. Permalloy $(Ni_{0.8}Fe_{0.2})$ as a magnetic core was also electroplated under 2000 gauss to induce the magnetic anisotropy. The core had the high DC effective permeability of $\~1,300$ and coercive field of $\~0.1$ Oe. The fabricated fluxgate sensor had the very small actual size of $3.0\times1.7\;mm^2$. The fluxgate sensor with a racetrack shaped core had the high sensitivity .of $\~350$ V/T at excitation condition of 3 $V_{P-P}$ and 2 MHz square wave. When two fluxgates were perpendicularly aligned in terrestrial field, their two-axis output signals were very useful to commercialize an electronic azimuth compass for the portable navigation system.

Growth and Photosensor Properties for $AgInS_2$ Single Crystal Thin Film ($AgInS_2$ 단결정 박막 성장과 광센서 특성)

  • Hong, Kwang-Joon;Baek, Seong-Nam
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.134-135
    • /
    • 2006
  • $AgInS_2$ single crystal thin filmsl was deposited on throughly etched semi-insulator GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperature were $680^{\circ}C$ and $410^{\circ}C$ respectively, and the thickness of the single crystal thin films is $6{\mu}m$. From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the $AgInS_2$ single crystal thin film, we have found that the values of spin orbit coupling ${\Delta}So$ and the crystal field splitting ${\Delta}Cr$ were 0.0098 eV and 0.15 eV at 10 K, respectively. In order to explore the applicability as a photoconductive cell, we measured the sensitivity ($\gamma$), the ratio of photocurrent to darkcurrent (pc/dc), maximum allowable power dissipation (MAPD), spectral response and response time. The result indicated that the samples annealed in S vapour the photoconductive characteristics are best. Therefore we obtained the sensitivity of 0.98, the value of pc/dc of $1.02{\times}10^6$, the MAPD of 312 mW, and the rise and decay time of 10.4ms and 10.8ms respectively.

  • PDF

Efficient baseline suppression via TIP and modified DEPTH

  • Hyun, Namgoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.26 no.4
    • /
    • pp.51-58
    • /
    • 2022
  • The baseline flattened NMR spectrum has been achieved by several methodologies including pulse manipulation with a series of phase cycling. The background signal inherent in the probe is also main source of baseline distortion both in solution and solid NMR. The simple direct polarization with 90° pulse flipping the magnetization from the z-axis onto the receiver coil requires the strong rf pulse enough to encompass the wide frequency range to excite the resonance of interest nuclei. Albeit the perfect polarization 90° pulse, the signal from the unwanted magnetic fields such as background signal can not be completely suppressed by suitable phase cycling. Moreover, slowly baseline wiggling signal from the low 𝛾 nuclei is not easy to eliminate with multiple pulse manipulation. So there is still need to contrive the new scheme for that purpose in an adroit manner. In this article new triple pulse excitation schemes for TIP and modified DEPTH pulse sequence are analytically examined in terms of arbitrary phase and flip angle of pulse. The suitable phase cycling for these pulse trains is necessary for the good sensitivity and resolution of the spectrum. It is observed that the 13C sensitivity TIP experiment is almost equal to the CP/MAS with modified DEPTH sequence, both of which are applicable to both solid and solution state NMR.

Optical Design and Tolerance Analysis for UVO-Multiband Polarizing Imager System

  • Han, Jimin;Chang, Seunghyuk;Park, Woojin;Lee, Sunwoo;Ahn, Hojae;Kim, Geon Hee;Lee, Dae-Hee;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2020
  • UVO-Multiband Polarizing Imager System (UVOMPIS) is an ultraviolet to visible light multi-wavelength polarization/imaging system for Compact Advanced Satellite. We developed Linear Astigmatism Free-Three Mirror System (LAF-TMS) D200F2 as an optical system of UVOMPIS which has an entrance pupil diameter of 200 mm, a focal ratio of 2, a field of view of 2° × 4°. LAF-TMS is a confocal off-axis reflecting telescope system that removes linear astigmatism, and its all mirrors (M1, M2, M3) are optimized with the freeform surface to reduce high-order aberrations. Through the sensitivity analysis and Monte-Carlo simulation as the tolerance analysis, we can confirm the feasibility of the system, relatively sensitive parameters (tilt, decenter, despace, surface RMS error), and considerations for optomechanical design. From the sensitivity analysis, we can discover the relatively sensitive optical alignment parameters to a single perturbation. Further more, in the monte-carlo simulation, we investigate the minimum tolerance budget satisfying the required optical performance and whether the tolerance range is satisfied within manufacturing error.

  • PDF

UV Effect on the Number of Primordial Germ Cells in the Embryo of Rana dybowskii (자외선이 산개구리 (Rana dybowskii) embryo의 시원생식세포 수에 미치는 영향)

  • 정해문;김원숙
    • The Korean Journal of Zoology
    • /
    • v.27 no.1
    • /
    • pp.13-24
    • /
    • 1984
  • The fertilized eggs of Rana dybowskii were irradiated with UV (254 nm wave length) on the vegetal hemisphere to investigate the effects on the primordial germ cells (PGCs) and axis formation. The investigations were carried out in two ways; namely time course and UV dose. Up to 1,600 $ergs/mm^2$ of UV dose, irradiated at 60 min. after fertilization, there was no effect on the PGC number. However, the number of PGC comparing with that of unirradiated control was decreased more than 40%. As the amount of irradiation was increased, the number of PGC was inversely declined. The maximal dose of irradiation which eliminates PGC completely without inducing any axis abnormality was 4,800 $ergs/mm^2$. If the eggs were irradiated earlier with this amount the severer effect could be obtained. Thus the UV effect on the PGC number was most effective when irradiated by 60 min. post fertilization. Thereasfter stage. At UV doses over 9,600 $erge/mm^2$ other effects start to appear; namely abnormalities of nerual tube and axis formation. Therefore, comparative study on the UV sensitivity of PGC and axis formation was carried out. It was revealed that UV effect on the axis was drastically decreased at the time of $0.7\\sim0.8$ between fertilization and 1st cleavage, while the germ plasm was sensitive to UV until 4 cell stage.

  • PDF

miR-335 Targets SIAH2 and Confers Sensitivity to Anti-Cancer Drugs by Increasing the Expression of HDAC3

  • Kim, Youngmi;Kim, Hyuna;Park, Deokbum;Jeoung, Dooil
    • Molecules and Cells
    • /
    • v.38 no.6
    • /
    • pp.562-572
    • /
    • 2015
  • We previously reported the role of histone deacetylase 3 (HDAC3) in response to anti-cancer drugs. The decreased expression of HDAC3 in anti-cancer drug-resistant cancer cell line is responsible for the resistance to anti-cancer drugs. In this study, we investigated molecular mechanisms associated with regulation of HDAC3 expression. MG132, an inhibitor of proteasomal degradation, induced the expression of HDAC3 in various anti-cancer drug-resistant cancer cell lines. Ubiquitination of HDAC3 was observed in various anti-cancer drug-resistant cancer cell lines. HDAC3 showed an interaction with SIAH2, an ubiquitin E3 ligase, that has increased expression in various anti-cancer drug-resistant cancer cell lines. miRNA array analysis showed the decreased expression of miR-335 in these cells. Targetscan analysis predicted the binding of miR-335 to the 3'-UTR of SIAH2. miR-335-mediated increased sensitivity to anti-cancer drugs was associated with its effect on HDAC3 and SIAH2 expression. miR-335 exerted apoptotic effects and inhibited ubiquitination of HDAC3 in anti-cancer drug-resistant cancer cell lines. miR-335 negatively regulated the invasion, migration, and growth rate of cancer cells. The mouse xenograft model showed that miR-335 negatively regulated the tumorigenic potential of cancer cells. The down-regulation of SIAH2 conferred sensitivity to anti-cancer drugs. The results of the study indicated that the miR-335/SIAH2/HDAC3 axis regulates the response to anti-cancer drugs.

Design, Fabricaiton and Testing of a Piezoresistive Cantilever-Beam Microaccelerometer for Automotive Airbag Applications (에어백용 압저항형 외팔보 미소 가속도계의 설계, 제작 및 시험)

  • Ko, Jong-Soo;Cho, Young-Ho;Kwak, Byung-Man;Park, Kwan-Hum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.408-413
    • /
    • 1996
  • A self-diagnostic, air-damped, piezoresitive, cantilever-beam microaccelerometer has been designed, fabricated and tested for applications to automotive electronic airbag systems. A skew-symmetric proof-mass has been designed for self-diagnostic capability and zero transverse sensitivity. Two kinds of multi-step anisotropic etching processes are developed for beam thickness control and fillet-rounding formation, UV-curing paste has been used for sillicon-to-glass bounding. The resonant frequency of 2.07kHz has been measured from the fabricated devices. The sensitivity of 195 $\mu{V}$/g is obtained with a nonlinearity of 4% over $\pm$50g ranges. Flat amplitude response and frequency-proportional phase response have been obserbed, It is shown that the design and fabricaiton methods developed in the present study yield a simple, practical and effective mean for improving the performance, reliability as well as the reproducibility of the accelerometers.