• 제목/요약/키워드: Sensitive to radiation

검색결과 386건 처리시간 0.028초

THERMOLUMINESCENCE DOSIMETRIC PROPERTIES OF Ge- AND Er-DOPED OPTICAL FIBRES AND THEIR APPLICATION IN THE MEASUREMENT OF DEPTH -DOSE IN SOLID WATER PHANTHOM

  • Amin, Y.M.;Abdulla, Y.A.;Khoo, B.H.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.143-147
    • /
    • 2001
  • The dosimetric properties of Ge- and Er-doped optical fibres are studied. The Ge-doped fibre is found to be more sensitive to radiation and there is little fading of TL signal compared with Er-doped fibre. The Ge- and Er-doped fibres showed a linear response over a range of ${\sim}1\;Gy$ to about 120 Gy and ${\sim}1Gy$ to about 250Gy respectively. The Ge-doped fibre is found to be dose-rate independent both for photons and electron beams of energy ranging from 6 to 10 MeV and 6 to 12 MeV respectively. The fibre is energy independent for energy greater than ${\sim}0.1\;MeV$ for photon or 0.1 MeV for electron beam. From the depth-dose measurement, it was found that the position of maximum dose, dmax, increased with increasing energy ranging from ${\sim}2\;cm$ and ${\sim}2.5\;cm$ for 6 MeV and 10 MeV photons respectively. The central axis percentage depth dose at 10 cm depth was found to be in good agreement with the value obtained using ionization chamber.

  • PDF

선량과 선질에 따른 형광량계 응답특성 (The Response of Fluorescence Meter according to X-ray dose and quality)

  • 김정민;김명준;윤종민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.71-75
    • /
    • 1995
  • In order to establish the photographic effects and sensitivity of various screens, fluorescence meter is used with convenience. When the radiation quality has been fixed the fluorescence has increased in proportion to X-ray dose. However, the response of fluorescence meter has the dependency of X-ray quality in accordance with KVP. as well as the difference of screen and scatter fraction can influence on the response of fluorescence meter. Using accurate fluorescence meter as a radiation detecter and as for a proper supervision the sensitive materials, we have to aware of the meter's dependency of X-ray quality and the scatter fraction.

  • PDF

Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance

  • Ananda Amaral Santos;Brunno Santos de Freitas Silva;Fernanda Ferreira Nunes Correia;Eleazar Mezaiko;Camila Ferro de Souza Roriz;Maria Alves Garcia Silva;Deborah Queiroz Freitas;Fernanda Paula Yamamoto-Silva
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.159-169
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate the influence of different cone-beam computed tomography (CBCT) acquisition protocols on reducing the effective radiation dose while maintaining image quality. Materials and Methods: The effective dose emitted by a CBCT device was calculated using thermoluminescent dosimeters placed in a Rando Alderson phantom. Image quality was assessed by 3 experienced evaluators. The relationship between image quality and confidence was evaluated using the Fisher exact test, and the agreement among raters was assessed using the kappa test. Multiple linear regression analysis was performed to investigate whether the technical parameters could predict the effective dose. P-values<0.05 were considered to indicate statistical significance. Results: The optimized protocol (3 mA, 99 kVp, and 450 projection images) demonstrated good image quality and a lower effective dose for radiation-sensitive organs. Image quality and confidence had consistent values for all structures (P<0.05). Multiple linear regression analysis resulted in a statistically significant model. The milliamperage (b=0.504; t=3.406; P=0.027), kilovoltage peak (b=0.589; t=3.979; P=0.016) and number of projection images (b=0.557; t=3.762; P=0.020) were predictors of the effective dose. Conclusion: Optimized CBCT acquisition protocols can significantly reduce the effective radiation dose while maintaining acceptable image quality by adjusting the milliamperage and projection images.

INFRARED EMISSION FROM SPHERICAL DUST CLOUDS

  • Lee, Hyung-Mok;Hong, Seung-Soo;Yun, Hong-Sik;Lee, Sang-Gak
    • 천문학회지
    • /
    • 제25권2호
    • /
    • pp.111-128
    • /
    • 1992
  • Infrared emissions from spherical dust, clouds are calculated using quasi-diffusion method. We have employed graphite-silicate mixture with power-law size distribution for the dust model. The grains are assumed to be heated and cooled by radiative processes only. The primary heating source is diffuse interstellar radiation field. hut the cases with an embedded source are also considered. Since graphite grains have higher temperature than silicate grains, the observed IR emission is mainly due to graphite grains, unless the fraction of graphite grains is negligibly small. The color temperature of Bok globules obtained from IRAS 60 and $100{\mu}m$ data are found to be consistent with the dust cloud with graphite-silicate mixture exposed to average interstellar radiation field. The color temperature is sensitive to the external radiation field, but rather insensitive to the size distribution of the grains. We found that the density distribution can be recovered outside the beam size using the inversion technique that assumes negligible optical depth. However, the information within the beam size is lost for if beam convolved intensity distributions are used in deriving density profile.

  • PDF

출력 소음을 고려한 직접방사형 라우드스피커의 비선형 매개변수 규명 (Identification of Nonlinear Parameters of Electrodynamic Direct-Radiator Loudspeaker with Output Noise)

  • 박석태;홍석윤
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.887-899
    • /
    • 1998
  • It has been resulted that Lagrange multiplier method with statistical approach was superior to traditional harmonic balance method in identifying the nonlinear loudspeaker parameters when output signals were contaminated with Gaussian random noise. We have known that the displacement-dependent characteristic values of nonlinear parameters identified by traditional harmonic balance method were estimated less than original values by the increase of output noise and the stiffness coefficients were very sensitive to output noise. Also, by the sensitivity analysis we have verified that the harmonic distortions in acoustic radiation was mainly due to nonlinearity of force factor caused by uneven magnetic fields and that reducing the nonlinearity of damping coefficients were very effective for improving second harmonic distrotion of acoustic radiation.

  • PDF

U937 세포에서 발암관련 유전자들로 구성된 DNA chip을 이용한 방사선 감수성 유전자들의 선발 (Identification of Radiation-Sensitive Gene in U937 Cell by using cDNA-Chip Composed of Human Cancer Related Gene)

  • 김종수;김인규;강경선;윤병수
    • 한국환경성돌연변이발암원학회지
    • /
    • 제22권1호
    • /
    • pp.54-59
    • /
    • 2002
  • We have used cDNA microarray hybridization to identify gene regulated in response to gamma-irradiation in U-937 cell. The cDNA-chip was composed entirely of 1,000 human cancer related gene including apoptosis and angiogenesis etc. In gamma-irradiated U-937 cell, highly charged protein, ribosomal protein L32, four and a half LIM domains 3, lipocalin 2 (oncogene 24p3) and interleukin 15, ataxia telangiectasia mutated (includes complementation groups A, C and D) genes showed increased level of its transcription, and cell division cycle 25A, dihydrofolate reductase, topoisomerase (DNA) II beta(180kD), kinase suppressor of ras and strarigin genes showed reduced level of its transcription compared to untreated U-937 cell. The significant change of level of transcription was not found in well-known ionizing radiation(IR)-responsive gene, such as transcription factor TP53 and p53 related gene, except ataxia telangiectasia mutated gene.

  • PDF

pH-Sensitivity Control of PEG-Poly(${\beta}$-amino ester) Block Copolymer Micelle

  • Hwang, Su-Jong;Kim, Min-Sang;Han, Jong-Kwon;Lee, Doo-Sung;Kim, Bong-Sup;Choi, Eun-Kyung;Park, Heon-Joo;Kim, Jin-Seok
    • Macromolecular Research
    • /
    • 제15권5호
    • /
    • pp.437-442
    • /
    • 2007
  • Poly(ethylene glycol) methyl ether (PEG)-poly(${\beta}$-amino ester) (PAE) block copolymers were synthesized using a Michael-type step polymerization, and the construction of pH-sensitive polymeric micelles (PM) investigated. The ${\beta}$-amino ester block of the block copolymers functioned as a pH-sensitive moiety as well as a hydrophobic block in relation to the ionization of PAE, while PEG acted as a hydrophilic block, regardless of ionization. The synthesized polymers were characterized using $^1H-NMR$, with their molecular weights measured using gel permeation chromatography. The $pK_b$ values of the pH-sensitive polymers were measured using a titration method. The pH-sensitivity and critical micelle concentration (CMC) of the block copolymers in PBS solution were estimated using fluorescence spectroscopy. The pH dependent micellization behaviors with various bisacrylate esters varied within a narrow pH range. The critical micelle concentration at pH 7.4 decreased from 0.032 to 0.004 mg/mL on increasing the number of methyl group in the bisacrylate from 4 to 10. Also, the particle size of the block copolymer micelles was determined using dynamic light scattering (DLS). The DLS results revealed the micelles had an average size below 100 nm. These pH-sensitive polymeric micelles may be good carriers for the delivery of an anticancer drug.

Comparison of Characteristics of Gamma-Ray Imager Based on Coded Aperture by Varying the Thickness of the BGO Scintillator

  • Seoryeong Park;Mark D. Hammig;Manhee Jeong
    • Journal of Radiation Protection and Research
    • /
    • 제47권4호
    • /
    • pp.214-225
    • /
    • 2022
  • Background: The conventional cerium-doped Gd2Al2Ga3O12 (GAGG(Ce)) scintillator-based gamma-ray imager has a bulky detector, which can lead to incorrect positioning of the gammaray source if the shielding against background radiation is not appropriately designed. In addition, portability is important in complex environments such as inside nuclear power plants, yet existing gamma-ray imager based on a tungsten mask tends to be weighty and therefore difficult to handle. Motivated by the need to develop a system that is not sensitive to background radiation and is portable, we changed the material of the scintillator and the coded aperture. Materials and Methods: The existing GAGG(Ce) was replaced with Bi4Ge3O12 (BGO), a scintillator with high gamma-ray detection efficiency but low energy resolution, and replaced the tungsten (W) used in the existing coded aperture with lead (Pb). Each BGO scintillator is pixelated with 144 elements (12 × 12), and each pixel has an area of 4 mm × 4 mm and the scintillator thickness ranges from 5 to 20 mm (5, 10, and 20 mm). A coded aperture consisting of Pb with a thickness of 20 mm was applied to the BGO scintillators of all thicknesses. Results and Discussion: Spectroscopic characterization, imaging performance, and image quality evaluation revealed the 10 mm-thick BGO scintillators enabled the portable gamma-ray imager to deliver optimal performance. Although its performance is slightly inferior to that of existing GAGG(Ce)-based gamma-ray imager, the results confirmed that the manufacturing cost and the system's overall weight can be reduced. Conclusion: Despite the spectral characteristics, imaging system performance, and image quality is slightly lower than that of GAGG(Ce), the results show that BGO scintillators are preferable for gamma-ray imaging systems in terms of cost and ease of deployment, and the proposed design is well worth applying to systems intended for use in areas that do not require high precision.

X-RAY FLUORESCENCE IN RESEARCH ON THE CULTURAL HERITAGE

  • Cechak, Tomas;Kopecka, Ivana;Musilek, Ladislav
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.321-326
    • /
    • 2001
  • Radionuclide X-ray fluorescence analysis is a method, which has many advantages for analysing various historic artefacts, as it is relatively cheap, sensitive and non-destructive, and it allows measurements in-situ. However, this analysis has also certain limitations especially concerning sensitivity to chemical elements only, irrespective of the compounds or chemical forms in which these elements have been bonded. In addition, light elements emitting very soft X-rays cannot be measured, and in order to detect a wide range of elements, it is necessary to carry out repeated measurements with different radiation sources. Despite these limitations, valuable information can be obtained about the composition of historic materials and data about the origin and age of these artefacts can be derived. Analyses of wall paintings, ancient metal sculptures or other objects of art provide the basis for historic considerations documented in our results for some objects belonging to the Czech cultural heritage. The results are promising. Thus it is expected that our laboratory will expand its work into more fields of the fine and applied arts.

  • PDF

방사선과 대학생이 방사선피폭관리에 대한 지식, 태도, 행위에 관한 연구 (A Study on Perceptions by College Students of Radiology about the Knowledge, Attitudes and Behaviors of Radiation Exposure Management)

  • 여진동;고인호;김혜숙
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.79-99
    • /
    • 2015
  • 본 연구의 조사대상은 대구, 경북지역에 소재한 대학교에 재학 중인 방사선과를 전공하는 대학생을 조사대상으로 2014년 2월 3일부터 2월21일까지 설문조사를 실시하여 다음과 같은 결과를 얻었다. 1. 방사선피폭관리에 대한 지식에 대해서는 'X선의 차폐는 납이나 콘크리트로 된 물질이 가능 하다', '인체에서 생식선은 방사선에 매우 민감한 부분이다' 문항에서 가장 높은 점수를 보였고, '직업상 피폭선량은 규정된 5년간에 대해 평균하여 연간 20 mSv를 넘을 수 없다'는 방사선피폭관리에 대한 지식이 가장 낮은 점수를 보였다. 2. 방사선피폭관리에 대한 태도에 대해서는 '방사선피폭과 관련하여 정기적인 건강진단을 받아야한다'. '방사선 조사지역에서 작업 시 방호복을 착용해야한다'는 문항에서 가장 높은 태도 수준을 보였고, '방사선장치의 선량보정 (Calibration)을 위한 선량측정을 정기적으로 해야 한다'는 방사선피폭관리에 대한 태도에서 가장 낮은 태도수준을 보였다. 3. 방사선피폭관리에 대한 행위에 대해서는 '방사선 조사 시 방어벽(판) 뒤에서 작업을 한 다'. '방사선피폭관리에 관한 교육을 정기적으로 받는 다'는 문항에서 가장 높은 행위 수준을 보였고, '근무지의 방사선 관련 장비가 순조로운 작업 상태로 되어 있는가를 사용 전 점점(Check)한다'는 가장 낮은 행위 수준을 보였다.