• 제목/요약/키워드: Sensitive film

검색결과 393건 처리시간 0.028초

RF Sputtering을 이용한 전류 민감성 차단 디바이스에 관한 연구 (The Study on a sensitive current limiting breaking device using RF Sputtering)

  • 이세현;정광희;박두기;김용락;이종철;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1088-1092
    • /
    • 1995
  • In this paper, we evaluated the sputter-deposited Cr/Cu thin film fuses on $Al_2O_3$ substrates by the adhesive, breaking and repetitive over-current test as a function of temperature on them. Each Cr and Cu was deposited $1700{\pm}300{\AA},\;3700{\pm}300{\AA}$ using RF sputtering unit. The electroplated Cu of $25{\mu}m$ thickness was added in order to make sensitive thin film fuse of the normal current 15[A]. The adhesive strength and the number of repetition were Increasing and then decreasing with the temperature. The maximum adhesive strength of over $9kgf/9mm^2$ was obtained at $400^{\circ}C$. In the breaking test, the post-arc time characteristic was better than any other factor.

  • PDF

임상가를 위한 특집 3 - 교합력 측정의 방법과 임상적 적용 (The methods for occlusal force measurement and their clinical applicatio)

  • 박지만;허성주;전윤식
    • 대한치과의사협회지
    • /
    • 제50권1호
    • /
    • pp.22-30
    • /
    • 2012
  • The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack- tooth syndrome, temporomandibul ar disease, and idiopathic implant loosening.

자성유체의 밀폐공간내 열전달특성에 관한 수치적 연구 (A Numerical Analysis on the Heat Transfer Characterristics of Magnetic Fluid in a Rectangular Enclosure)

  • 유신오;박명호;박길문;박정우;서이수;전철호
    • 한국유체기계학회 논문집
    • /
    • 제6권1호
    • /
    • pp.37-43
    • /
    • 2003
  • Natural convection of a magnetic fluid is different from that of Newtonian fluids because a magnetic body force exists in an addition to gravity and buoyancy forces. In this paper, the natural convection of a magnetic fluids (W-40) in a rectangular enclosure is investigated by numerical and experimental methods. One side wall is kept at a constant temperature ($25^{\circ}C$), and the opposite side wall is also kept at a constant temperature ($20^{\circ}C$), Under above conditions, the magnitude of the magnetic fields were varied and applied. GSMAC scheme is used for the numerical method, and the thermo-sensitive liquid crystal film (R20C5A) is utilized in order to visualize wall-temperature distributions as an experimental verification. This study has resulted in the following fact that the natural convection of a magnetic fluid is controlled by the direction and intensity of the magnetic fields.

Nb SQUID가 탑재된 초고감도 캔티레버 제작 (Fabrication of Nb SQUID on an Ultra-sensitive Cantilever)

  • 김윤원;이순걸;최재혁
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.36-41
    • /
    • 2009
  • Superconducting quantum phenomena are getting attention from the field of metrology area. Following its first successful application of Josephson effect to voltage standard, piconewton force standard was suggested as a candidate for the next application of superconducting quantum effects in metrology. It is predicted that a micron-sized superconducting Nb ring in a strong magnetic field gradient generates a quantized force of the order of sub-piconewtons. In this work, we studied the design and fabrication of Nb superconducting quantum interference device (SQUID) on an ultra-thin silicon cantilever. The Nb SQUID and electrodes were structured on a silicon-on-insulator (SOI) wafer by dc magnetron sputtering and lift-off lithography. Using the resulting SOI wafer, we fabricated V-shaped and parallel-beam cantilevers, each with a $30-{\mu}m$-wide paddle; the length, width, and thickness of each cantilever arm were typically $440{\mu}m,\;4.5{\mu}m$, and $0.34{\mu}m$, respectively. However, the cantilevers underwent bending, a technical difficulty commonly encountered during the fabrication of electrical circuits on ultra-soft mechanical substrates. In order to circumvent this difficulty, we controlled the Ar pressure during Nb sputtering to minimize the intrinsic stress in the Nb film and studied the effect of residual stress on the resultant device.

  • PDF

흉부X선촬영(胸部X線撮影)에 있어서 피폭선량(被曝線量)의 저감(低減)에 관(關)한 연구(硏究) (A Study on the Chest Radiography for Reducing Exposure Dose)

  • 이만구;윤한식;이종석;이선숙;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권1호
    • /
    • pp.41-49
    • /
    • 1996
  • We have been used super sensitive screen/film system which is thought to be the limit of sensitivity, however, we think this method is not satisfactory. As a general radiographic rule, reduction of exposure is inconsistent with improvement of image quality, but it is necessary to challenge this rule to get better method. We tried air gap method for minimal diffuse lung shadow which is difficult to find out by our routine method. As a result, air gap method with super sensitive screen/film system(SRO 1000/TMH) showed lower exposure dose, 50% of our routine system(SRO 750/SRH with grid), and better image quality for pulmonary pattern in the lower lung field.

  • PDF

인덕턴스 복사계 측정을 위해 사용된 초전도 자속 흐름 센서기 모델링 (Modeling of a Superconducting Flux Flow Sensor Inductance Radiometer)

  • 고석철;강형곤;임성훈;최명호;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.19-22
    • /
    • 2003
  • For use in constructing highly sensitive thermal detectors, the present authors have been studying the preparation of Superconducting Flux Flow Sensor(SFFS). In this research, SFFS with five channel ($5{\mu}m$/1channel) has been fabricated based on the flux flow using high temperature superconducting thin films by the ICP etching technique. We have designed a bolometer based on the temperature dependence of the kinetic inductance of a superconducting flux flow thin film. In this paper examines the fabrications and flux flow resistance and thermometer responses of the highly sensitive sensor constructed of a thin YBCO film. It is also suggested that they will be applicable to a new type of flux flow sensor.

  • PDF

흉부질환의 화질과 피폭을 고려한 촬영조건의 연구 (A Study on the Chest Radiography with Diseases in Consideration of Image Qualify and Patient Exposure)

  • 이만구;임태랑;석전유치
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.56-62
    • /
    • 1997
  • To evaluated the image quality and the patient exposure for the chest radiography, its fundamental imaging properties were investigated. The basic imaging properties were evaluated by measuring characteristic curves, relative speeds, average gradient, and patient exposure dose. The image qualities were evaluated by using a rotating meter. It was found that the film gradient of SRO750/SRH system was 3.13 and that of SRO750/HR-C30 was 1.77. The ratio of SRO1000/TMH to FS/RP-1 was 1 to 18.2. It was possible to visualize the static image when the exposure time was less than 2.5 msec in patient that had respiratory excessive motion, heart beat and natural physical motion, and less than 8.5 msec in normal. The ratio of medical exposure dose compared with our method was 1 to 25 in the routine chest radiography and maximum was 1 to 70. In estimation of the image quality in same cases, we found that the image of SRO1000/SRH and TMH of super sensitive systems was the same results. We found that these super sensitive screen-film systems were available for the chest radiography considering the relationship between the image quality and patient exposure.

  • PDF

스프링삽입형 유하액막식 흡수기의 열 및 물질전달 특성 (Characteristics of Heat and Mass Transfer for a Falling Film Type Absorber with Insert Spring Tubes)

  • 윤정인;오후규;백목효부
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1501-1509
    • /
    • 1995
  • It is known that the heat and mass transfer characteristics in the absorber are most sensitive of the temperature boost of all the heat exchangers and the development of a more efficient absorber should be highly important. This paper describes absorption experiments made with different inside tube diameters, tube length and tube shapes. The purpose of this study is to acquire basic knowledge about heat and mass transfer in a falling film type absorber with vertical inner tubes. Heat and mass transfer were measured for water vapor absorption into a Lithium Bromide-water solution flowing down an absorber of vertical inner tubes. As a result, insert spring tube compares bare tube and heat transfer improved by order of insert spring tube P2(pitch 20 mm) and P1(pitch 10 mm).

포지티브 포토레지스트의 감도 증진을 위한 산증식제로 1-Hydroxy-4-tosyloxy cyclohexane과 1,4-Ditosyloxy cyclohexane에 관한 연구 (1-Hydroxy-4-tosyloxy cyclohexane and 1,4-Ditosyloxy cyclohexane as Acid Amplifiers To Enhance the Photosensitivity of Positive-Working Photoresists)

  • 정연태;이은주;권경아
    • 한국인쇄학회지
    • /
    • 제20권1호
    • /
    • pp.91-101
    • /
    • 2002
  • An acid amplifier is defined as an acid-generating agent which is decomposed autocatalytically to produce new strongly acidic molecules in a non-liner manner, The addition of the acid amplifiers to conventional chemically amplified photoresists consisting of photoacid generators and acid-sensitive polymers result in the improvement of photosensitivity due to the amplified generation of catalytic acid molecules as a result of the decomposition of acid amplifiers. We synthesized and evaluated 1-hydroxy-4-tosyloxy cyclohexane(AA-1) and 1,4-ditosyloxy cyclohexane(Ah-2) as novel acid amplifiers. The acid amplifiers(AA-1, AA-2) showed reasonable thermal stability for resist processing temperature. As estimated by the sensitivity curve, tort-butyl methacrylate homopolymer(ptBMA) film doped with AA-1 or 2 exhibited much higher photosensitivity than ptBMA film without AA-1 or 2. And AA-1 showed higher effect than AA-2 on enhancing photosensitivity of ptBMA film.

  • PDF

적층형 커패시터의 응용을 위한 고유전 박막 재료의 연구 (The study of the high dielectric thin films for MLCC)

  • 장범식;최원석;문상일;장동민;홍병유;이준신
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.836-839
    • /
    • 2001
  • Ba(Zr$_{x}$Ti$_{l-x}$)O$_3$(BZT) thin films of x=0.2 and 150nm thickness were prepared on Pt/SiO$_2$/Si substrate by RF Magnetron Sputtering deposition at several temperature (40$0^{\circ}C$, 50$0^{\circ}C$, $600^{\circ}C$). As the substrates temperature increase, crystallization of the films and high dielectric constants can be obtained. Capacitance of the film deposited at high temperature is more sensitive to the applied voltage than that of the film deposited at low temperature, and the film's breakdown voltage is higher in low temperature.ure.

  • PDF