• 제목/요약/키워드: Sensing-rate

검색결과 722건 처리시간 0.024초

Sensing and Compression Rate Selection with Energy-Allocation in Solar-Powered Wireless Sensor Networks

  • Yoon, Ikjune
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권5호
    • /
    • pp.81-88
    • /
    • 2017
  • Solar-powered wireless sensor nodes can use extra energy to obtain additional data to increase the precision. However, if the amount of data sensed is increased indiscriminately, the overhead of relay nodes may increase, and their energy may be exhausted. In this paper, we introduce a sensing and compression rate selection scheme to increase the amount of data obtained while preventing energy exhaustion. In this scheme, the neighbor nodes of the sink node determine the limit of data to be transmitted according to the allocated energy and their descendant nodes, and the other nodes select a compression algorithm appropriate to the allocated energy and the limitation of data to be transmitted. A simulation result verifies that the proposed scheme gathers more data with a lower number of blackout nodes than other schemes. We also found that it adapts better to changes in node density and the amount of energy harvested.

Compressed sensing을 이용한 TOF MRA 검사에서 Flow rate와 CS factor의 변화에 따른 영향 (Effects of Flow Rates and CS Factors on TOF MRA using Compressed Sensing)

  • 김성호;정현근;유세종
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.281-291
    • /
    • 2021
  • 본 연구는 자기공명영상을 이용한 TOF MRA 검사에서 flow rate 2.0 ml 이하의 유속을 표현함에 있어 Compressed sensing의 사용에 따른 영상의 변화를 정량적으로 측정하고자 하였다. Auto-injector와 Flow phantom을 이용하여 각각의 혈류속도 구간을 설정하고 CS를 사용하지 않은 TOF without CS 기법과 CS를 이용한 TOF with CS 기법에서 CS factor의 변화에 따른 SNR, CNR, SSIM, RMSE 등을 측정하여 비교하였다. CS factor의 증가에 따라 나타나는 영상의 영향을 검증하고자 일원배치 분산분석(One-way ANOVA)을 시행하였다. 실험 결과 CS를 사용한 TOF MRA는 CS를 사용하지 않은 TOF MRA와 비교하여 SNR 및 CNR의 유의한 차이 없이 scan time이 현저하게 감소하였다. 반면 CS factor의 증가에 따라 SSIM 및 RMSE는 TOF without CS 영상과의 차이가 증가함을 나타내었다. 따라서 TOF MRA 검사 시 CS 기법을 통해 scan time을 효율적으로 감소시키되 적절한 CS factor의 범위를 충분히 고려해야 한다. 또한 CS factor와 영상의 유사도, 정밀성에 대한 지속적인 연구가 필요할 것으로 사료된다.

데이터 손실이 있는 RCS 데이터에서 압축 센싱 이론을 적용한 ISAR 영상 복원 알고리즘 연구 (A Study on the ISAR Image Reconstruction Algorithm Using Compressive Sensing Theory under Incomplete RCS Data)

  • 배지훈;강병수;김경태;양은정
    • 한국전자파학회논문지
    • /
    • 제25권9호
    • /
    • pp.952-958
    • /
    • 2014
  • 본 논문에서는 불완전한 radar-cross-section(RCS) 데이터로부터 inverse synthetic aperture radar(ISAR) 영상 복원과 동시에 표적의 회전각도를 추정하기 위한 compressive sensing(CS) 기반의 레이더 신호 모델을 적용한 parametric sparse 복원 알고리즘을 제안하고자 한다. Sparse 복원 알고리즘으로는 iteratively-reweighted-least-square(IRLS) 기법을 이용하여 각도 방향(cross-range)에서 모르는 처프 비율(chirp rate)의 처프 성분을 포함하는 레이더 신호 모델과 결합한다. 그리고, particle swarm optimization(PSO) 최적화 알고리즘을 이용하여 표적의 회전각도와 연관된 파라미터들을 추출한다. 따라서, RCS 데이터 샘플에 데이터 손실이 발생하더라도 본 논문의 IRLS 기반 parametric sparse 복원 알고리즘에 따라 효율적으로 ISAR 영상을 복원할 수 있고, 동시에 표적의 회전각도를 추정할 수 있다. 또한, 불완전한 RCS 데이터 샘플에 대하여 영상의 엔트로피 관점에서 본 논문에서 제안한 방법의 성능과 전통적인 보간법의 성능을 서로 비교 관찰한다.

Concrete structural health monitoring using piezoceramic-based wireless sensor networks

  • Li, Peng;Gu, Haichang;Song, Gangbing;Zheng, Rong;Mo, Y.L.
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.731-748
    • /
    • 2010
  • Impact detection and health monitoring are very important tasks for civil infrastructures, such as bridges. Piezoceramic based transducers are widely researched for these tasks due to the piezoceramic material's inherent advantages of dual sensing and actuation ability, which enables the active sensing method for structural health monitoring with a network of piezoceramic transducers. Wireless sensor networks, which are easy for deployment, have great potential in health monitoring systems for large civil infrastructures to identify early-age damages. However, most commercial wireless sensor networks are general purpose and may not be optimized for a network of piezoceramic based transducers. Wireless networks of piezoceramic transducers for active sensing have special requirements, such as relatively high sampling rate (at a few-thousand Hz), incorporation of an amplifier for the piezoceramic element for actuation, and low energy consumption for actuation. In this paper, a wireless network is specially designed for piezoceramic transducers to implement impact detection and active sensing for structural health monitoring. A power efficient embedded system is designed to form the wireless sensor network that is capable of high sampling rate. A 32 bit RISC wireless microcontroller is chosen as the main processor. Detailed design of the hardware system and software system of the wireless sensor network is presented in this paper. To verify the functionality of the wireless sensor network, it is deployed on a two-story concrete frame with embedded piezoceramic transducers, and the active sensing property of piezoceramic material is used to detect the damage in the structure. Experimental results show that the wireless sensor network can effectively implement active sensing and impact detection with high sampling rate while maintaining low power consumption by performing offline data processing and minimizing wireless communication.

Performance Analysis of Amplify and Forward (AF)-based Cooperative Spectrum Sensing in Cognitive Radio Networks

  • Khan, Muhammad Sajjad;Koo, Insoo
    • Journal of information and communication convergence engineering
    • /
    • 제11권4호
    • /
    • pp.223-228
    • /
    • 2013
  • Cognitive radio has been recently considered a promising technology to improve spectrum utilization by enabling secondary access to licensed bands that are not used by primary users temporarily or spatially. A prerequisite to this secondary access is the lack of interference to the primary system. This requirement makes spectrum sensing a key process for cognitive radio. In this study, we consider amplify and forward (AF)-based cooperative spectrum sensing for cognitive radio networks where multiple relay nodes are utilized to amplify and forward the primary user signal for better spectrum sensing, and maximum ratio combining is used for fusion detection by a cognitive coordinator. Further, the detection probability and the bit error rate of AF-based cooperative spectrum sensing are analyzed in fading multiple cognitive relay channels. The simulation results show that the AF-based cooperative spectrum sensing scheme outperforms the conventional scheme.

인지 무선 네트워크에서 상관관계를 갖는 다중 신호를 위한 협력 베이지안 압축 스펙트럼 센싱 (Cooperative Bayesian Compressed Spectrum Sensing for Correlated Signals in Cognitive Radio Networks)

  • 정홍규;김광열;신요안
    • 한국통신학회논문지
    • /
    • 제38B권9호
    • /
    • pp.765-774
    • /
    • 2013
  • 본 논문에서는 분산된 광대역 인지 무선 네트워크 환경에서 상관관계를 갖는 다중 신호를 위한 협력 압축 스펙트럼 센싱 기법을 제안한다. 압축 센싱 (Compressed Sensing)은 나이퀴스트율 (Nyquist Rate) 이하로 샘플링된 신호를 높은 확률로 복구할 수 있는 신호처리 기법으로 기존의 광대역 스펙트럼 센싱을 위해서 필요로 했던 고속의 아날로그-디지털 변환기 구현 문제를 해결할 수 있다. 압축 센싱에서는 압축된 신호를 원본 신호로 정확하게 복구하는 복구 알고리즘을 설계하는 것이 하나의 핵심 문제이다. 본 논문에서는 나이퀴스트율 이하로 압축된 신호의 복구 성능을 높이기 위하여 연속된 다중 입력 신호로 구성된 Multiple Measurement Vector 모델을 이용하였고, 입력 신호 사이의 시간적 상관관계를 이용하는 협력 베이지안 복구 알고리즘을 제안한다.

클러스터링 기반의 CR시스템에서 가중치 협력 스펙트럼 센싱 기술의 개선연구 (Improved Weighted-Collaborative Spectrum Sensing Scheme Using Clustering in the Cognitive Radio System)

  • 최규진;손성환;이주관;김재명
    • 한국ITS학회 논문지
    • /
    • 제7권6호
    • /
    • pp.101-109
    • /
    • 2008
  • 본 논문은 클러스터링 기법을 도입하여 기존에 제안된 가중치 협력 스펙트럼 시스템에서 실질적으로 구하지 못했던 Pd를 구하고, 새로운 가중치 생성 알고리즘을 통하여 1차 사용자 신호의 감지 성능을 향상시키는 방법을 제안하였다. 유사한 채널을 같는 CR 사용자를 클러스터링 기법을 이용하여 그룹화하여 각각의 사용자로부터 획득한 센싱 결과를 토대로 Pd를 계산하였다. 또한, 각 클러스터의 검출확률의 제곱 합을 이용하여 가중치(Wj(n+1))를 생성하였다. 이는 기존의 방식보다 센싱 성능이 우수하였으며, 특히 1차 사용자의 신호가 갑자기 사라졌을 경우 신호가 없는 상황에서의 검출 확률인 false alarm rate가 낮아지는 결과를 보였다. 컴퓨터 모의실험을 통하여 이를 검증한다.

  • PDF

Fatigue characteristics of distributed sensing cables under low cycle elongation

  • Zhang, Dan;Wang, Jiacheng;li, Bo;Shi, Bin
    • Smart Structures and Systems
    • /
    • 제18권6호
    • /
    • pp.1203-1215
    • /
    • 2016
  • When strain sensing cables are under long-term stress and cyclic loading, creep may occur in the jacket material and each layer of the cable structure may slide relative to other layers, causing fatigue in the cables. This study proposes a device for testing the fatigue characteristics of three types of cables operating under different conditions to establish a decay model for observing the patterns of strain decay. The fatigue characteristics of cables encased in polyurethane (PU), GFRP-reinforced, and wire rope-reinforced jackets were compared. The findings are outlined as follows. The cable strain decayed exponentially, and the decay process involved quick decay, slow decay, and stabilization stages. Moreover, the strain decay increased with the initial strain and tensile frequency. The shorter the unstrained period was, the more similar the initial strain levels of the strain decay curves were to the stabilized strain levels of the first cyclic elongation. As the unstrained period increased, the initial strain levels of the strain decay curves approached those of the first cyclic elongation. The tested sensing cables differed in the amount and rate of strain decay. The wire rope-reinforced cable exhibited the smallest amount and rate of decay, whereas the GFRP-reinforced cable demonstrated the largest.

용액 공정으로 증착된 HfOx 감지막을 갖는 Electrolyte-Insulator-Semiconductor 소자의 두께 의존성 (Thickness Dependence of Solution Deposited HfOx Sensing Membrane for Electrolyte-Insulator-Semiconductor (EIS) Structures)

  • 이인규;조원주
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.233-237
    • /
    • 2013
  • We fabricated electrolyte-insulator-semiconductor (EIS) devices using a solution process and measured the sensing properties of EIS devices according to the thicknesses of sensing membrane. For high pH sensitivity and better stability properties, we used $SiO_2/HfO_x$ (OH) layer as a sensing membrane. In this work, $HfO_x$ sensing membranes were deposited on 5 nm thick $SiO_2$ buffer layer by spin coater with thicknesses of 15, 31, 42, 55 nm, respectively. As a result, we founded that the thickness of $HfO_x$ sensing membrane affects to sensitivity and chemical stability of EIS device. Especially, the EIS device with 42 nm thick $HfO_x$ membrane showed superior sensing ability in terms of pH-sensitivity, linearity, hysteresis voltage and drift rate characteristics than the other devices. In conclusion, we confirmed that it is possible to improve the sensing ability and the chemical stability properties using optimized thickness of sensing membrane and proper annealing process.

표면적 변화에 기반한 입체적 웨어러블 호흡수 센서의 가능성 탐색 (A Study on the Possibility of Three-dimensional Wearable Respiration Rate Sensor based on Surface Area Changes)

  • 이승표;반현성;이주현
    • 감성과학
    • /
    • 제21권1호
    • /
    • pp.35-44
    • /
    • 2018
  • 본 연구에서는 센서의 표면적 변화에 따른 입체적 호흡수 센서의 센싱 방식을 제안하고, 직물 기반의 입체적 호흡수 센서의 성능 평가 및 의복에 적용할 수 있는 디자인 방향성을 탐색하고자 한다. 이를 위해 입체적 구조의 차이에 따라 2가지 유형의 입체적 호흡수 센서를 제작하고 더미와 인체 대상으로 연구를 실시하였다. 연구I은 더미 대상 실험으로 센서의 유형 및 호흡 속도의 연구변인에 의해 입체적 호흡수 센서의 측정 가능성을 탐색하였다. 연구II는 7명의 20대 남성을 대상 실험으로 연구I의 연구변인 이외에 3개의 측정 위치별 적합한 유형의 센서를 제안하였다. 입체적 호흡수 센서의 정확도, 재현성, 신뢰도를 평가하기 위해, 의료기기 분야의 대표적 웨어러블 호흡수 센서인 BIOPAC을 사용하여 입체적 호흡수 센서와 동시에 호흡수를 측정하였다. 이상의 연구 결과를 통해 더미 대상으로 입체적 호흡수 센서의 측정 가능성을 탐색하였으며, 인체 대상으로 호흡수를 측정하여 측정 위치별 적합한 유형의 센서를 제안하였다.