• Title/Summary/Keyword: Sensing Valve

Search Result 47, Processing Time 0.035 seconds

Study about the home network system implementation that used an ubiquitous sensor network (유비쿼터스 센서 네트워크을 이용한 홈네트워크 시스템 구현에 관한 연구)

  • Nam, Sang-Yep;Park, Chun-Myoung
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.479-480
    • /
    • 2007
  • It is study about implementation of the home network system that used an ubiquitous sensor network and an embedded system in this paper. PXA270 and CC2420 were used, and the home server of a wireless sensor home network system composed it. A wireless control system is composed of a gas valve, a DC motor, a lamp and a door rock. A wireless detection system is composed of a gas detection sensor, a movement detection sensor, an extension detection sensor The wireless detection system that was an environment sensing system was composed of temperature, humidity, mic, illuminance, a speed-up, infrared rays temperature sensing module, and modular, other RFID established an USB camera, and an ubiquitous home network was composed.

  • PDF

Bio-monitoring System for Early Detection of Toxic Dinoflagellate Alexandrium pacificum Using the Shell Valve Movements of Bivalves (유독 와편모조류 Alexandrium pacificum의 조기 탐지를 위한 이매패류 패각운동 생물모니터링 시스템 연구)

  • Jeong, Soo Yong;Kim, Dae Hyun;Oh, Seok Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_3
    • /
    • pp.979-989
    • /
    • 2022
  • We examined changes in the shell valve movements (SVMs) of Mytilus edulis and Crassostrea gigas using a Hall element sensor to investigate the early detection of the toxic dinoflagellate Alexandrium pacificum. No increase or decrease was observed in SVMs caused by the non-toxic algae Isochrysis galbana in both M. edulis and C. gigas. However, when M. edulis and C. gigas were exposed to A. pacificum, which causes paralytic shellfish poisoning, the average SVMs for 12 hours before and after exposure increased from 1.25 times/hr to 2.13 times/hr and 2.23 times/hr to 8.91 times/hr, respectively. After exposure to A. pacificum, the SVMs of M. edulis increased rapidly within 1 hour and then decreased gradually. However, C. gigas showed high SVMs until 4 hours after exposure. SVMs of C. gigas appeared to be more sensitive to toxic dinoflagellate than those of M. edulis. Therefore, these results are expected to be used as basic data for the establishment of a biological monitoring system for early detection of the toxic dinoflagellate A. pacificum.

Response Characteristic of HVDC System According to Frequency Sensing Methods (주파수 측정방법에 따른 HVDC시스뎀의 응답특성)

  • Kim C,K;Yang B.M;Park J.G.;Jeong G.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.299-303
    • /
    • 2003
  • This paper deals with the frequency sensing methods at HVDC system. The objects of frequency information in HVDC system areto fire a valve and to control a frequency of AC network. Conventionally, there are two methods to measure a frequency of AC network. The first method is to draw out from the synchronous machine and the second method is from AC network. Two methods have advantages and disadvantage each other. For the extreme case of a receiving system of zero inertia (no generation), synchronous machine is essential. In this situation, the frequency information received from the synchronous machine shaft. However, the speed of synchronous machine is oscillated when a disturbance in AC network occurs, and HVDC may be oscillated due to an oscillation speed. To solve this drawback, in this paper, new frequency sensing method is proposed. A proposed method that is use a modified curve-fitting algorithm, has a robust characteristics against a harmonics and unbalanced faults. Consequently, A proposed method is verified by PSCAD/EMTDC Program and experimental test.

  • PDF

Method of Test for Combustion Instability and Control at Model Combustor of Supersonic Engine (초음속 엔진 모델 연소기에서의 연소불안정 및 제어 시험 기법)

  • Choi, Ho-Jin;Hwang, Yong-Seok;Jin, You-In;Park, Ik-Soo;Yoon, Hyun-Gull;Kang, Sang-Hun;Lee, Yang-Ji
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.111-115
    • /
    • 2009
  • The method of test for observing the combustion instability and controling the instability actively by using secondary injection of fuel through flame stabilizer was studied by constructing model combustor of supersonic engine. The frequency of combustion instability was detected by measuring the pressure of combustor using pressure sensor and by optical sensing of flame intensity. Electro-magnetic valve was adopted as actuator for active control and the characteristics of modulated fuel was studied by measured pressure of valve outlet and scattering signal of spray at secondary fuel injection.

  • PDF

Application of Guided Ultrasonic Wave Technology for Evaluation of Welding Part in Cooling Water Pipe (냉각수 배관 용접부 평가를 위한 유도초음파 기술의 적용)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.5
    • /
    • pp.36-40
    • /
    • 2010
  • The ultrasonic guided wave propagates along with the given structure's wall direction. Because of this specific character, the ultrasonic guided waves arc used in many other fields. Especially, it can be readily utilized for nondestructive inspection of various structures that are made up of gas pipes, heat exchanger tubes, and thin plates. Further, the guided wave technology can be readily utilized when inspecting pipes or thin plates which pose high risk of the accident but for which the nondestructive inspection itself is impossible because it is difficult to get to them since they are coated or buried underground. In the other hand, conventional ultrasonic testing such as thickness gauging uses bulk waves and only tests the region of structure immediately below the transducer. As a result of the application about inlet and outlet cooling water line using guided wave test, we conformed that the overall corrosions were in the lower side of the 304.8 mm inlet valve and these corrosions were engaged in not locally but through the lower side of the valve line. In the near future, we can expect that the detectable defect size is smaller than before along with the development of the sensing technology.

Uniaxial Magnetic Anistotropy of a NiO-Spin Valve Device

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • The shape anisotropy effect of a giant magnetoresistance-spin valves (GMR-SV) device with a glass/NiO/NiFe/CoFe/Cu/CoFe/NiFe layered structure for use in the detection of magnetic property of molecules within a cell was investigated. The patterned device was given uniaxial anisotropy during the sputtering deposition and vacuum post-annealing, which was performed at $200^{\circ}C$ under a 300 Oe magnetic field. The pattern size of the device, which was prepared through the photolithography process, was $2{\times}15\;{\mu}m^2$. The experimental results confirmed that the best design for a GMR-SV device to be used as a biosensor is to have both the axis sensing current and the easy axis of the pinned NiO/NiFe/CoFe triple layer oriented in the direction of the device's width, while the easy axis of the free CoFe/NiFe bilayer should be pointed along the long axis of the device.

Development of Performance Verification Method for Components of IoT-based Industrial Valve Safety Management System (IoT 기반 산업용 밸브 안전관리 시스템 구성장치의 성능검증 방안 개발)

  • Kim, Jae-Ok;Lyu, Geun-Jun;Lee, Kyung-Sik;Kim, Jung-Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.10-19
    • /
    • 2020
  • Valve leak accidents in petrochemistry plants and gas utilities cause human and property damage. The main reason why happen gas inhalation, poisoning, fire and explosion accidents is gas valve leakage. To prevent gas leakage, inspectors check the facilities in the field. And they are at risk of gas leak accidents. So we applied IoT-based risk assessment, monitoring and automatic control system. It can detect both internal and external gas leakage, do real-time monitoring of industrial valve in the plant by using hybrid sensor. As the new safety management system for industrial valve is developed, it needs method to evaluate device performance and environmental components for the system. This study is about development of method to verify performance of the explosion-proofed hybrid sensing system include gas detector and optical fiber sensor supporting wire and wireless communication.

An Analysis of Mechanism of Auto-Sensing Breaker's Automatic Impact (지능형 브레이커의 자동타격 메카니즘 분석)

  • Park, Sung-Su;Noh, Dae-Kyung;Lee, Dae-Hee;Lee, Geun-Ho;Kang, Young-Ky;Cho, Jae-Sang;Jang, Joo-sup
    • Journal of the Korea Society for Simulation
    • /
    • v.25 no.4
    • /
    • pp.31-42
    • /
    • 2016
  • This study aims to identify the core technology for the automatic impact of the auto-sensing breaker that is one of the construction machinery which do not have a notable development success case yet in Korea. The study has been carried out as follows. Firstly, an analysis model was developed after determining the interconnection of pressure receiving area, opening area and port. And then, a simulation of situation that hard rock and soft rock are mixed was carried out to verify if it is possible to switch between long impact mode and short impact mode continuously. Lastly, the dynamic behavior of automatic control valve induced by the change of impact mode was analyzed based on the analysis result to decipher the core principle of automatic impact control.

Pneumatic circuit design and Performance test of Air balancer (에어밸런서 공압 회로의 설계 및 성능 실험)

  • Kim, D.S.;Bae, S.K.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.20-24
    • /
    • 2006
  • Air balancer is a conveyance cargo-handling machine, used in assembly and process lines of car and machining industries. This can lift up an object, the weight of which is from 5 to 200 kg, and moves it to a position. As industrial technologies evolve, it is required to move an object and fit it into a specified position with greater accuracy, rather than performing simple tasks such as lifting objects up and down as conventional ones do. There is also a demand to handle an object with one hand, rather than with two hands,. Through designs of manifold unit for an air balancer function, pilot regulator unit to keep pressure constant, hand unit for an accurate load perception function, and air balancer circuit, this study enables everybody to work it with ease and convenience. Experiments and comparisons were conducted for the performance evaluation of the circuit.

  • PDF

Fabrication of Biochip Using Gray-scale Photolithography (Gray-scale photolithography를 이용한 바이오칩 제작)

  • Bae, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.137-141
    • /
    • 2008
  • Biochip, which implements bioanalytical process on a tiny surface, is one of candidates for medical diagnosis, drug screening, and molecular sensing. In general, a type of biochip based on microfluidics is composed of microcomponents including microchannel, pump, and valve, which require complicated processes. In this study, gray-scale photolithography(GSPL) was applied to fabricate a biochip with multiple layers. A mould for casting PDMS(polydimethylsiloxane) channel, was fabricated using GSPL. A gray-photomask was prepared by printing gray patterns on a high-quality glossy paper followed by photoreducing by 10:1 onto the photo-film. The formation of multiple layers was studied according to the change of gray level of pattern and the developing time. A biochip composed of a weir(multiple layer structure) and a reaction chamber in a single microchannel was fabricated in a glass plate. Finally, we investigated the application of biochip to antigen-antibody reaction by packing the microbead coated with antibody.