• Title/Summary/Keyword: Sensible Heat

Search Result 332, Processing Time 0.031 seconds

Performance Evaluation of Four Different Land Surface Models in WRF

  • Lee, Chong Bum;Kim, Jea-Chul;Belorid, Miloslav;Zhao, Peng
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.42-50
    • /
    • 2016
  • This study presents a performance evaluation of four different land surface models (LSM) available in Weather Forecast Research (WRF). The research site was located in Haean Basin in South Korea. The basin is very unique by its geomorphology and topography. For a better representation of the complex terrain in the mesoscale model were used a high resolution topography data with a spatial resolution of 30 meters. Additionally, land-use layer was corrected by ground mapping data-sets. The observation equipments used in the study were an ultrasonic anemometer with a gas analyzer, an automatic weather station and a tethered balloon sonde. The model simulation covers a four-day period during autumn. The result shows significant impact of LSM on meteorological simulation. The best agreement between observation and simulation was found in the case of WRF with Noah LSM (WRF-Noah). The WRF with Rapid Update Cycle LSM (WRF-RUC) has a very good agreement with temperature profiles due to successfully predicted fog which appeared during measurements and affected the radiation budget at the basin floor. The WRF with Pleim and Xiu LSM (WRF-PX) and WRF with Thermal Diffusion LSM (WRF-TD) performed insufficiently for simulation of heat fluxes. Both overestimated the sensible and underestimated the latent heat fluxes during the daytime.

A Feasibility Study on Geothermal Power Plant in Korea (한국형 지열발전 타당성 연구)

  • Lim, Hyo-Jae;Kwon, Jung-Tae;Kim, Geum-Soo;Chang, Ki-Chang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.39-44
    • /
    • 2009
  • Geothermal energy is the heat contained in the earth and its internal fluids. Geothermal energy is stored as sensible or latent heat. Supplied by both internal and external sources, it represents a vast supply which is only started to be tapped for generation of electric power. In general, this is natural dry or wet medium to high enthalpy steam at temperatures above $150^{\circ}C$. For some time, binary systems employing substances with a lower boiling point than water in a secondary circuit have been used to generate vapor for driving turbines at a lower temperature level. The utilization of binary plants and the possibility of production from enhanced geothermal systems can expand its availability on a worldwide basis. The geothermal electricity installed capacity is approaching the 10,000GW threshold. Geothermal energy is not present everywhere, but its baseload capability is a very important factor for its success.

  • PDF

Performance Analysis of Ammonia-Water Regenerative Rankine Cycles for Use of Low-Temperature Energy Source (저온 열원 활용을 위한 암모니아-물 재생 랭킨 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Han, Chul-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5kW per unit mass flow rate of source air at $180^{\circ}C$.

Study Characteristics in Packed Tower of Liquid Desiccant Solar Cooling System Using Counter Flow Configuration

  • Rahmanto, R. Hengki;Choi, K.H.;Agung, B.;Sukmaji, I.C.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.168-174
    • /
    • 2009
  • High water vapour content in air can cause a number of problems as for human or surrounding materials. For human a high water vapour can create physiological stress, discomfort, and also can encourage ill health. While, the cause for the environment is can accelerate the corrosion of metals, accelerate the growth of spores and mould, can reduce the electrical resistance of insulators and etc. Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling especially the latent load and also sensible load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed tower of liquid desiccant solar cooling system and the heat transfer and mass transfer will occur. This thesis is trying to study the characteristics inside the packed tower of dehumidifier systems. This characteristics consist of mass transfer rate, heat transfers rate, human comfort and energy that consume by the system. Those characteristics were affected by air flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems. The results of this thesis later on can be used to determine the best performance of the systems.

  • PDF

Sea Level Variations at Kerguelen Island in the South Indian Ocean by the Satellite Data(ARGOS) and Meteorological Data(METEO)

  • Yoon, Hong-Joo
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.2
    • /
    • pp.117-133
    • /
    • 2000
  • We studied the sea level variations at Kerguelen island in the South Indian Ocean with ARGOS data and meteorological data during about 1 year(May 1993~April 1994) through using filter, spectral analysis, coherency and phase, and found characteristics for the two oceanic signal levels(detided oceanic signal level, h$_{detided}$ and seasonal oceanic level, h$_{corr.ib}$). The forms of atmospheric pressure variations are good agreed to between ARGOS data and meteorological data in the observed periods. This Kerguelen area shows the inflow of an air temperature(gain of a radiant heat) into the sea water and the stagnation of high atmospheric pressure bands in summer, and the outflow of a sea water temperature(loss of sensible and latent heat) toward the atmosphere and the stagnation of low atmospheric pressure bands in winter. The seasonal difference of sea level between summer and winter is about 1.6cm. Both the detided oceanic signal level(h$_{detided}$) variation and the inverted barometer level(h$_{ib}$) variation have a strong correlation for T>1day period bands. The characteristics of h$_{detided}$ variation are not decided by the influence of any meteorological distributions (atmospheric pressure), but the influence of other factors(bottom water temperature) for T>2days periods bands. h$_{corr.ib}$ plays a very important role of sea level variation in the observed periods (especially T>about 180days period bands).

Evaluation the Community Land Model (CLM) using Fluxnet data over East Asia (동아시아 Fluxnet 자료를 활용한 지면모형(CLM)의 성능평가 및 개선)

  • Seo, Ho Cheol;Kim, Jeong Bin;Lee, Jae Hyeong;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.173-173
    • /
    • 2017
  • 지구표면에서 발생하는 물순환, 에너지순환, 탄소순환은 토지-대기-식생간의 물리화학적 관계에 의하여 발생하며 이를 모사하기 위해 지면 및 기후모델이 활용된다. 본 연구에서는 NCAR의 지면모형인 Community Land Model(CLM) v4.5를 동아시아에 적용하고자 한다. 동아시아 범위에서 Fluxtower가 설치되어 물, 에너지, 탄소 플럭스 자료가 관측된 지점에서 모형을 구동하고 결과를 평가하였다. CLM 결과에 따른 증발산(Evapotranspiration), 잠열(Latent heat), 헌혈(Sensible heat)과 같은 물 및 에너지 순환에 관한 결과 뿐 아니라 총 일차생산량(Gross primary production), 순생태계순환(Net ecosystem exchange), 생태계 호흡량(Ecosystem respiration)과 같은 탄소순환에 관한 결과를 비교, 분석하였다. 특히, 기초 결과 분석에 따라 지면 모형 내의 여러 모듈 중에서 화재 관련 모듈에 초점을 맞추어 CLM 모형을 개선하였다. 화재는 식생의 성장에 많은 영향을 미치는 모듈로서 탄소순환 모의에 중요한 역할을 한다. 전 지구 대상 모의를 기반으로 하는 CLM에서 삼림 및 초지 지역의 화재 발생는 국내총생산(Gross domestic product, GDP) 및 인구밀도에 따라 모수화되어 있으나, 이는 전 지구 혹은 지역 대상이 아닌 지점 수준의 모형적용을 위해 부적합하다. 이에 관련 모수들을 재산정하고 개선된 모형 결과를 정량화하기 위해 위에서 언급한 물순환, 에너지순환, 탄소순환 관련된 변수들의 모의값을 Fluxtower 관측값과 비교, 분석하였다.

  • PDF

Local Enhancement Mechanism of Cold Surges over the Korean Peninsula (한반도 한파의 지역적 강화 메커니즘)

  • Lee, Hye-Young;Kim, Joowan;Park, In-Gyu;Kang, Hyungyu;Ryu, Hosun
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.383-392
    • /
    • 2018
  • This study investigates synoptic characteristics of cold surges over South Korea during winter season (December-February). A total of 63 cold events are selected by quantile regression analysis using daily mean temperature observations from 11 KMA stations for 38 years (1979/80-2016/17). Large-scale pressure pattern during the cold surges is well characterized by high over Siberia and low over Aleutian regions, which elucidates cold advection over the Korean peninsula. However, the large-scale pattern cannot successfully explain the observed sudden decrease of temperature during the cold surges. Composite analyses reveal that a synoptic-scale cyclone developing over the northern Japan is a key feature that significantly contribute to the enhancement of cold advection by increasing pressure gradient over the Korean peninsula. Enhanced sensible and latent heat fluxes are observed over the southern ocean of Korea and Japan during the cold surges due to temperature and humidity differences between the near surface and the lower atmosphere over the ocean. The evaporated water vapor transported toward the center of the surface cyclone and condenses in the lower-to-middle troposphere. The released energy likely promotes the development of the surface cyclone by inducing positive PV near the surface of the heating region.

Impact of irrigation on global climate within Community Land Model(CLM) and Community Atmospheric Model(CAM) (기상기후모델(CLM)과 기상대기모델(CAM)을 활용한 관개농업이 기후에 미치는 영향)

  • Seo, Hocheol;Kim, Yeonjoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.103-103
    • /
    • 2018
  • 인류 문명이 발전되면서 이산화탄소 증가나 표지 피복도의 변화와 같은 인류의 영향으로 인하여 자연현상들은 많은 변화가 발생하고 있다. 특히 고대서부터 현재까지 농작물을 짓기 위해서 관개 수로를 이용한 농업이 발전되어져 왔다. 관개 농업은 작물의 생육과 알맞은 토양환경을 만들기 위해 깨끗한 물을 인공적으로 농업에 이용하기에 물 순환뿐 아니라 에너지 순환에 많은 영향을 미치는 요소이다. 따라서 그에 대한 메커니즘을 이해하는 것을 중요하다. 본 연구에서는 지상기후모형인 Community Land Model(CLM)과 대기기후모형인 Community Atmospheric Model(CAM)을 이용하였으며 관개농업에 관한 과정을 고려할 때와 고려하지 않았을 때 도출된 결과값들을 서로 비교함으로써 관개농업이 지구환경에 미치는 영향을 알아보았다. 관개농업으로 인하여 강수량, 증발산량(Evapotranspiration, ET)과 같은 수문량의 변화뿐 아니라 지하 토양수분과 지하수면 깊이(Water table depth)의 변화량과 같은 모델의 결과들을 시간적 공간적 변화를 나타냄으로써 관개농업이 물 순환에 미치는 영향을 제시하였다. 또한 에너지 순환의 변화에 미치는 영향을 알아보기 위해 잠열(Latent heat) 과 헌혈(Sensible heat)의 변화를 알아내어 관개가 에너지 순환에 미치는 영향을 알아보았다.

  • PDF

A Study on Thermally Stratied Hot Water Storage Tank in A Solar Heating System (태양열 난방 시스템에 적용되는 축열조의 성층화에 관한 연구)

  • Hong, Hi-Ki;Kim, Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.1
    • /
    • pp.87-96
    • /
    • 1986
  • An experiment on the devices that enchance the stratification of storage tanks in a solar heat ins system has been carried out. The benefits of thermal stratification in sensible heat storage are to increase the system performance such as the collector efficiency or the fraction of the total load supplied by solar energy. Using the diffuser and the distributor as the stratification enchancement device, the expeliments were perfomed in the different condition of diameter and material of the distributor. As a result of experiments, there exists the diameter of distributor in which the stratification is made maximum under certain design and operation condition. Also it was identified that the kind of distributor material influenced the degree of stratification. Comparing the experimental result to the computational results calculated under the same conditions, the node number N(stratification index) was determined. The results of computer simulation that was performed about the actual solar heating system in Seoul for 24 hours show the relative advantage of stratified over well-mixed storage and the significant improvements in system performance.

  • PDF

A Study of Simulation on the Refrigerated Warehouse System Based on the Cold Energy of Lng Using the Pro-Ii Simulator (LNG 냉열을 이용한 냉장·냉동 창고 모사에 관한 연구)

  • HAN, DANBEE;KIM, YOONJI;YEOM, KYUIN;SHIN, JAERIN;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.4
    • /
    • pp.401-406
    • /
    • 2017
  • When Liquified Natural Gas (LNG) is vaporized into NG for industrial and household usage, tremendous cold energy was transferred from LNG to seawater during phase-changing process. This heat exchanger loop is not only a waste of huge cold energy, but will cause thermal pollution to the coastal fishery area also when cold water was re-injected into the sea. In this study, an innovation design has been performed to reclaim the cold energy for -35 to $62^{\circ}C$ refrigerated warehouse. Conventionally, this was done by installing mechanical refrigeration systems, necessitating tremendous electrical power to drive temperature. A closed loop LNG heat exchangers in series was designed to replace the mechanical or vapor-compression refrigeration cycle by process simulator. The process simulation software of PRO II with provision has been used to simulate this process for various conditions, what to effect on cold energy and used energy for re-liquefaction and evaporation process. In addition, through analysis the effect of the change of LNG supply pressure on sensible and latent heat, optimum operational conditions was suggested for LNG cold energy warehouse.