• Title/Summary/Keyword: Semi-passive

Search Result 215, Processing Time 0.023 seconds

Reduced-mass Adaptive TMD for Tall Buildings Damping

  • Weber, Felix;Huber, Peter;Spensberger, Simon;Distl, Johann;Braun, Christian
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.2
    • /
    • pp.117-123
    • /
    • 2019
  • Tall buildings are prone to wind-induced vibrations due to their slenderness whereby peak structural accelerations may be higher than the recommended maximum value. The common countermeasure is the installation of a tuned mass damper (TMD) near the highest occupied floor. Due to the extremely large modal mass of tall buildings and because of the narrow to broad band type of wind excitation the TMD mass may become inacceptable large - in extreme cases up to 2000 metric tons. It is therefore a need to develop more efficient TMD concepts which provide the same damping to the building but with reduced mass. The adaptive TMD concept described in this paper represents a solution to this problem. Frequency and damping of the adaptive TMD are controlled in real-time by semi-active oil dampers according to the actual structural acceleration. The resulting enhanced TMD efficiency allows reducing its mass by up to 20% compared to the classical passive TMD. The adaptive TMD system is fully fail-safe thanks to a smart valve system of the semi-active oil dampers. In contrast to active TMD solutions the adaptive TMD is unconditionally stable and its power consumption on the order of 1 kW is negligible small as controllable oil dampers are semi-active devices. The adaptive TMD with reduced mass, stable behavior and lowest power consumption is therefore a preferable and cost saving damping tool for tall buildings.

Application Assessment of Passive Sampling to Monitor Polybrominated Diphenyl Ethers in Water Environment as Alternative Sampling Method for Grab Sampling (수계 중 폴리브롬화 디페닐에테르 모니터링을 위한 Passive Sampling 적용 및 그랩 시료채취법의 대체 활용가능성 평가)

  • Kim, Un-Jung;Seo, Chang Dong;Im, Tae-Hyo;Oh, Jeong-Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.45-51
    • /
    • 2015
  • PBDEs (polybrominated diphenyl ehters) are rarely dissolved in water due to their strong hydrophobicity and large molecular mass so not many researches were done in aqueous environment compared to other environmental compartments. However, the mass loading from wastewater treatment plant into aquatic environment, re-suspension from bottom sediment and partitioning from floating particles and colloids may not be negligible. It is, therefore, important but also difficult to investigate PBDEs in water environment. Recent overcoming resolution towards this barrier to monitor hydrophobic organic compounds in aquatic environment is using passive sampling technique like semipermeable membrane device. By using passive sampling, it might be possible to obtain long-term reproducible monitoring result and detect the trace amounts of PBDEs, with controlling fluctuation of surrounding environmental factors during the sampling event. So therefore, this study is purposed to confirm the possibility of using SPMD (semi-permeable membrane device) as water monitoring tool. Grab samples, composite samples and SPMDs were applied in river bank to evaluate the concentration difference and temporal fluctuation by various water sampling method, and to assess the water concentration prediction capability of SPMD for the PBDEs.

A Study on the Appication of Semi-Active Supension Units for a Combat Vehicle by Using HILS (HILS를 활용한 전투차량의 반능동 현수장치 적용에 관한 연구)

  • Kim, Chi-Ung;Kim, Moon-June;Rhee, Eun-Jun;Lee, Kyoung-Hoon;Woo, Kwan-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.967-975
    • /
    • 2010
  • There have been a lot of efforts on the improvement for the ride comfort and handling stability of the combat vehicles. Especially most of vehicles for military purpose have bad inertial condition and severe operating condition such as the rough road driving, and need a high mobility in the emergency status. It is necessary to apply the controlled suspension system in order to improve the vehicle mobile stability and ride comfort ability of crews. A feasibility study is performed on the application of the semi-active suspension system with a magneto-rheological controlled shock absorber for a $6{\times}6$ combat vehicle. First, the dynamic simulation model of the vehicle including the control model for the semi-active suspension system was executed. Based on this model, a hardware-in-the-loop simulation(HILS) system which has a semi-active suspension controller hardware was constructed. After full vehicle simulations were performed in virtual proving courses with this system, the semi-active suspension system was proven to give better ride comfort and handling stability in comparison with the conventional passive suspension system.

Study on Active Damper System Applying DC-Motor (DC Motor를 이용한 능동형 댐퍼 시스템에 대한 연구)

  • Lee, Hak-Cheol;Jeon, Jin-Young;Jeong, Young-Suk
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.121-123
    • /
    • 2008
  • The suspension systems currently in use can be classified as passive, semi-active and active. The passive suspension systems are the most commonly used due their low price and high reliability. However, this system cannot assure the desired performance form a modern suspension system. An important improvement of suspension performance is achieved by the active systems. This paper treats active damper system and applying DC-Motor. In this system, all the energy for active control is supplied from the damper, which regenerates energy. And simulations by sky-hook control.

  • PDF

The Pattern of Decision Making to Donate a Living Kidney (생체 신장을 주기 위한 공여자들의 의사결정 유형)

  • 이명선
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.1
    • /
    • pp.47-59
    • /
    • 2000
  • The purpose of this study was to explore decision making phenomenon of living kidney donation experienced by kidney donors. Data were collected through semi-structured indepth interviews from 12 kidney donors. All interviewes were audiotaped and transcribed verbatim. Constant comparative analysis was used to analyze the data with NUDIST4.0 software program. process have effects on the execution of kidney donation. Based on the degree of "wish to give", three distinct patterns were identified: Voluntary, compromising, and passive. The voluntary decision making was the most frequent one, while the passive the least. The degree of "wish to give" was influenced by intimacy between the donor and the receipient, geographical locations, economical efficiency of kidney transplantation, and religion. Each pattern was explained by describing interfering and facilitating factors as well as other issues occured in the decision making process. The results of this study will help nurses make effective nursing intervention by understanding the characteristics of decision-making patterns and decision-making process to donate a living kidney.

  • PDF

High Performance Wilkinson Power Divider Using Integrated Passive Technology on SI-GaAs Substrate

  • Wang, Cong;Qian, Cheng;Li, De-Zhong;Huang, Wen-Cheng;Kim, Nam-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.129-133
    • /
    • 2008
  • An integrated passive device(IPD) technology by semi-insulating(SI)-GaAs-based fabrication has been developed to meet the ever increasing needs of size and cost reduction in wireless applications. This technology includes reliable NiCr thin film resistor, thick plated Cu/Au metal process to reduce resistive loss, high breakdown voltage metal-insulator-metal(MIM) capacitor due to a thinner dielectric thickness, lowest parasitic effect by multi air-bridged metal layers, air-bridges for inductor underpass and capacitor pick-up, and low chip cost by only 6 process layers. This paper presents the Wilkinson power divider with excellent performance for digital cellular system(DCS). The insertion loss of this power divider is - 0.43 dB and the port isolation greater than - 22 dB over the entire band. Return loss in input and output ports are - 23.4 dB and - 25.4 dB, respectively. The Wilkinson power divider based on SI-GaAs substrates is designed within die size of $1.42\;mm^2$.

Modulation Depth Dependence of Timing Jitter and Amplitude Modulation in Mode-Locked Semiconductor Lasers (모드잠김 반도체 laser의 타이밍 지터및 크기 변조의 변조 신호 크기 의존성)

  • Kim, Ji-hoon;Bae, Seong-Ju;Lee, Yong-Tak
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.276.2-278
    • /
    • 2000
  • In a recent years, a number of approaches have been studied, including passive, active, and hybrid mode-locking of semi-conductor lasers for short pulse generation and research has been devoted to achieve low timing-jitter operation since the timing jitter is unfavorable for system applications. Among the methods of mode locking, passive mode locking does not need external rf drives, and therefore the operation and fabrication procedures are simplified. In spite of these attractive advantages of passive mode-locked laser, it has critical drawbacks such as large timing jitter and the difficulty in synchronization with external circuits. Their inherent large timing jitter value was shown to be suppressed to certain levels by means of hybrid mode-locking technique$^{(1)}$ , where the saturable absorber section was modulated by an external signal with the cavity round trip frequency. Furthermore, the subharmonic mode-locking (SHML) technique alleviates the restrictions of high speed driving electronics. It has been demonstrated experimentally$^{(1)}$ that the hybrid subharmonic mode-locking technique has lead to significant reduction of the timing jitter. (omitted)

  • PDF

TAPINS: A THERMAL-HYDRAULIC SYSTEM CODE FOR TRANSIENT ANALYSIS OF A FULLY-PASSIVE INTEGRAL PWR

  • Lee, Yeon-Gun;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.439-458
    • /
    • 2013
  • REX-10 is a fully-passive small modular reactor in which the coolant flow is driven by natural circulation, the RCS is pressurized by a steam-gas pressurizer, and the decay heat is removed by the PRHRS. To confirm design decisions and analyze the transient responses of an integral PWR such as REX-10, a thermal-hydraulic system code named TAPINS (Thermal-hydraulic Analysis Program for INtegral reactor System) is developed in this study. Based on a one-dimensional four-equation drift-flux model, TAPINS incorporates mathematical models for the core, the helical-coil steam generator, and the steam-gas pressurizer. The system of difference equations derived from the semi-implicit finite-difference scheme is numerically solved by the Newton Block Gauss Seidel (NBGS) method. TAPINS is characterized by applicability to transients with non-equilibrium effects, better prediction of the transient behavior of a pressurizer containing non-condensable gas, and code assessment by using the experimental data from the autonomous integral effect tests in the RTF (REX-10 Test Facility). Details on the hydrodynamic models as well as a part of validation results that reveal the features of TAPINS are presented in this paper.

Vibration reduction of a pipe conveying fluid using the semi-active electromagnetic damper

  • Kavianipour, Omid
    • Coupled systems mechanics
    • /
    • v.6 no.2
    • /
    • pp.175-187
    • /
    • 2017
  • This paper deals with a uniform cantilever Euler-Bernoulli beam subjected to follower and transversal force at its free end as a model for a pipe conveying fluid under electromagnetic damper force. The electromagnetic damper is composed of a permanent-magnet DC motor, a ball screw and a nut. The main objective of the current work is to reduce the pipe vibration resulting from the fluid velocity and allow it to transform into electric energy. To pursue this goal, the stability and vibration of the beam model was studied using Ritz and Newmark methods. It was observed that increasing the fluid velocity results in a decrease in the motion of the free end of the pipe. The results of simulation showed that the designed semiactive electromagnetic damper controlled by on-off damping control strategy decreased the vibration amplitude of the pipe about 5.9% and regenerated energy nearly 1.9 (mJ/s). It was also revealed that the designed semi-active electromagnetic damper has better performance and more energy regeneration than the passive electromagnetic damper.

A Study on the Design and Performance of Continuously Variable Suspension System using Electro-Rheological Fluids (전기변성유체를 이용한 연속가변 현수장치 시스템의 디자인 및 성능에 관한 연구)

  • 장문석;김수태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.543-546
    • /
    • 1997
  • The purpose of this study is to investigate the ERSU(Electr0-Rheological Suspension IJnit) and some progress of damping force characteristic of a ERSU. This paper describes overall construction of th'e system design and the manufacturing of ERSU. A model of the ERSU is made by using electric field dependent on Bingham properities of ER fluid. In this paper. the ERSU is designed and manufactured for a light ground tracked vehicle. From the results, it is shown that the damping performance of ERSLJ is better than that of a passive suspension unit. This experimental study might be very useful for the simulat~on and the design of semi-active suspension units.

  • PDF