• Title/Summary/Keyword: Self-expandable metallic stents

Search Result 16, Processing Time 0.025 seconds

Left Wedge Pneumonectomy for the Complication of the Self Expandable Metallic Stent -A Case Report- (Self expandable Metallic Stent 합병증으로 인한 좌측 전폐 설상 절제술 -치험 1례-)

  • Kim, Jin;Shin, Hyeong-Ju;Kuh, Ja-Hong;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.28 no.2
    • /
    • pp.201-205
    • /
    • 1995
  • Most of the patient with endobronchial tuberculosis have some degree of bronchial stenosis. however, a part of bronchial stenosis need aggressive treatment for the patency because of severe symptoms. The self-expendable metallic stents provide palliative treatment for narrowed airways where surgical resection is inadvisable. We experienced a successful left wedge pneumonectomy on a 29-year-old woman with obstruction of left main bronchus due to complication of the bronchial stent. She had inserted self-expendable metallic stents on left main bronchus of the tuberculous bronchial stenosis two times. There was no specific postoperative complication.

  • PDF

Optimal endoscopic drainage strategy for unresectable malignant hilar biliary obstruction

  • Itaru Naitoh;Tadahisa Inoue
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.135-142
    • /
    • 2023
  • Endoscopic biliary drainage strategies for managing unresectable malignant hilar biliary obstruction differ in terms of stent type, drainage area, and deployment method. However, the optimal endoscopic drainage strategy remains unclear. Uncovered self-expandable metal stents (SEMS) are the preferred type because of their higher functional success rate, longer time to recurrent biliary obstruction (RBO), and fewer cases of reintervention than plastic stents (PS). Other PS subtypes and covered SEMS, which feature a longer time to RBO than PS, can be removed during reintervention for RBO. Bilateral SEMS placement is associated with a longer time to RBO and a longer survival time than unilateral SEMS placement. Unilateral drainage is acceptable if a drainage volume of greater than 50% of the total liver volume can be achieved. In terms of deployment method, no differences were observed in clinical outcomes between side-by-side (SBS) and stent-in-stent deployment. Simultaneous SBS boasts a shorter procedure time and higher technical success rate than sequential SBS. This review of previous studies aimed to clarify the optimal endoscopic biliary drainage strategy for unresectable malignant hilar biliary obstruction.

Covered Self-expandable Metallic Stent Insertion as a Rescue Procedure for Postoperative Leakage after Primary Repair of Perforated Duodenal Ulcer (십이지장 궤양 천공 단순 봉합수술 후 완전 피막형 자가확장 금속 스텐트 삽입술로 치료된 봉합 부위 누출)

  • Yoo, Young Jin;Lee, Yong Kang;Lee, Joong Ho;Lee, Hyung Soon
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.262-266
    • /
    • 2018
  • Surgery has been the standard treatment for perforated duodenal ulcers, with mostly good results. However, the resolution of postoperative leakage after primary repair of perforated duodenal ulcer remains challenging. There are several choices for re-operation required in persistent leakage from perforated duodenal ulcers. However, many of these choices are complicated surgical procedures requiring prolonged general anesthesia that may increase the chances of morbidity and mortality. Several recent reports have demonstrated postoperative leakage after primary repair of a perforated duodenal ulcer treated with endoscopic insertion using a covered self-expandable metallic stent, with good clinical results. We report a case with postoperative leakage after primary repair of a perforated duodenal ulcer treated using a covered self-expandable metallic stent.

Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow (정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성)

  • 이홍철;김철생;박복춘;박복춘
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2003
  • This experimental study is aimed at evaluating the hydrodynamic performance of newly designed self-expandable graft stents under steady flow condition. Two graft stents with different coating materials and a bare TiNi metallic stent for comparison test were used in the experiment. Pressure variation and velocity distribution at the upstream and downstream of the stents were measured at flow rates of 5, 10, and 15 l/min, respectively. Pressure loss due to insertion of the stent increased with increasing flow rate exponentially as expected. At a flow rate of 15 l/min, pressure loss of Polyure-thane(PU)-coated graft stent was 6 times higher than that of TiNi metallic stent, while the pressure loss of a porous Polytetrafluoroethylene(PTFE)-coated graft stent was comparable to a bare TiNi metallic stent. Velocity profiles of the porous PTFE-coated graft stent were similar to those of a bare TiNi metallic stent regardless of flow rate. Furthermore, the velocity profile of PU-coated graft stent revealed an asymmetrical and relatively low central velocity at a higher flow rate than 10 1/min, expecially, where the effects resulted in increases of wall shear stress and normal stress. The worse hydrodynamic behavior of PU-coated graft stent than the other two stents might be attributed to formation of folds due to poor flexibility of coated material when inserting the graft stent into the pipe with a more smaller size, which later gave rise non-symmetry of flow area, increase of surface roughness and jet flow via the crevice between the stent and cylinder wall.

Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction

  • Taro Shibuki;Kei Okumura;Masanari Sekine;Ikuhiro Kobori;Aki Miyagaki;Yoshihiro Sasaki;Yuichi Takano;Yusuke Hashimoto
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.802-811
    • /
    • 2023
  • Background/Aims: Covered self-expandable metallic stents (cSEMS) have become popular for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting (EUS-HGS). We compared the time to recurrent biliary obstruction (TRBO), complications, and reintervention rates between EUS-HGS using plastic stent (PS) and cSEMS in patients with unresectable malignancies at multicenter institutions in Japan. Methods: Patients with unresectable malignant biliary obstruction who underwent EUS-HGS between April 2015 and July 2020 at any of the six participating facilities were enrolled. Primary endpoint: TRBO; secondary endpoints: rate of complications other than recurrent biliary obstruction and technical success rate of reintervention were evaluated. Results: PS and cSEMS were used for EUS-HGS in 109 and 43 patients, respectively. The TRBO was significantly longer in the cSEMS group than in the PS group (646 vs. 202 days). Multivariate analysis identified two independent factors associated with a favorable TRBO: combined EUS-guided antegrade stenting with EUS-HGS and the use of cSEMS. No significant difference was observed in the rate of complications other than recurrent biliary obstruction between the two groups. The technical success rate of reintervention was 85.7% for PS and 100% for cSEMS (p=0.309). Conclusions: cSEMS might be a better option for EUS-HGS in patients with unresectable malignancies, given the longer TRBO.

Self-expandable metallic stent-induced esophagorespiratory fistulas in patients with advanced esophageal cancer

  • Iatagan R. Josino;Bruno C. Martins;Andressa A. Machado;Gustavo R. de A. Lima;Martin A. C. Cordero;Amanda A. M. Pombo;Rubens A. A. Sallum;Ulysses Ribeiro Jr;Todd H. Baron;Fauze Maluf-Filho
    • Clinical Endoscopy
    • /
    • v.56 no.6
    • /
    • pp.761-768
    • /
    • 2023
  • Background/Aims: Self-expandable metallic stents (SEMSs) are widely adopted for the palliation of dysphagia in patients with malignant esophageal strictures. An important adverse event is the development of SEMS-induced esophagorespiratory fistulas (SEMS-ERFs). This study aimed to assess the risk factors related to the development of SEMS-ERF after SEMS placement in patients with esophageal cancer. Methods: This retrospective study was performed at the Instituto do Cancer do Estado de São Paulo. All patients with malignant esophageal strictures who underwent esophageal SEMS placement between 2009 and 2019 were included in the study. Results: Of the 335 patients, 37 (11.0%) developed SEMS-ERF, with a median time of 129 days after SEMS placement. Stent flare of 28 mm (hazard ratio [HR], 2.05; 95% confidence interval [CI], 1.15-5.51; p=0.02) and post-stent chemotherapy (HR, 2.0; 95% CI, 1.01-4.00; p=0.05) were associated with an increased risk of developing SEMS-ERF, while lower-third tumors were a protective factor (HR, 0.5; 95% CI, 0.26-0.85; p=0.01). No difference was observed in overall survival. Conclusions: The incidence of SEMS-ERFs was 11%, with a median time of 129 days after SEMS placement. Post-stent chemotherapy and a 28 mm stent flare were associated with a higher risk of SEMS-ERF.

Self-Expandable metallic Stent in Benign Tracheobronchial Stenosis (양성기관지 협착증 환자에서 팽창성 금속성 스텐트의 사용경험)

  • Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Jeon, Seok-Chol;Chung, Won-Sang;Kim, Kung-Hun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.4
    • /
    • pp.318-324
    • /
    • 1992
  • Acquired tracheobronchial stenosis has resulted from vehicular accidents, prolonged tracheal intubation, sleeve resection, tuberculosis and sarcodosis. Various modalities of therapy for the relief of such stenosis included surgery, cryotherapy, laser photoresection, and sometimes balloon dilatation. Several recent reports have described the use of self-expandable metal stents for the dilatation of stenotic areas in the tracheobronchial tree. Three patients of benign acquired tracheobronchial stenosis were treated with self-expandable metal stents, who had shown little response to several times of balloon dilatations; One patient had a tracheal stenosis caused by intubation, one a right main bronchial stenosis developed after reconstructive surgery of traumatic bronchial rupture, and the other a left main bronchial stenosis caused by longstanding endobronchial tuberculosis. We found that the using stent in benign acquired tracheobronchial stenosis can be effectively performed with alleviation of clinical symptoms and lung function. And even in longstanding localized stenosis of main bronchus without distal bronchial destruction, lung perfusion also improved.

  • PDF

Evaluation of the mechanical properties of current biliary selfexpandable metallic stents: axial and radial force, and axial force zero border

  • Wataru Yamagata;Toshio Fujisawa;Takashi Sasaki;Rei Ishibashi;Tomotaka Saito;Shuntaro Yoshida;Shizuka No;Kouta Inoue;Yousuke Nakai;Naoki Sasahira;Hiroyuki Isayama
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.633-649
    • /
    • 2023
  • Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

Percutaneous Placement of Self-expandable Metallic Biliary Stents in Malignant Extrahepatic Strictures: Indications of Transpapillary and Suprapapillary Methods

  • Deok Hee Lee;Jeong-Sik Yu;Jae Cheol Hwang;Ki Hwang Kim
    • Korean Journal of Radiology
    • /
    • v.1 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • Objective: To compare the efficacy of suprapapillary and transpapillary methods of transhepatic biliary metallic stent placement in malignant biliary strictures and to specify the indications of each method applied. Materials and Methods: Stents were placed in 59 patients. Strictures were categorized as type A (within 3 cm of the ampulla, n = 27), type B (over 3 cm from ampulla, n = 7), type C (within 3 cm of the bending portion, n = 9), or type D (over 3 cm above the bending portion, n=16). The stenting method was suprapapillary in 34 cases and transpapillary in 25. The rates of initial and long-term patency and of early recurrence were compared. Results: Initial patency rates for the suprapapillary and transpapillary methods were 1/7 (14.3%) and 20/20 (100%) respectively for type A (p < 0.0001), 4/5 (80.0%) and 2/2 for type B, 3/7 (42.9%) and 2/2 for type C, and 15/16 (93.8%) and 0/0 for type D. Early recurrence rates were 7/30 (23.3%) using the suprapapillary method and 4/29 (13.8%) using the transpapillary method (p = 0.51). The long-term patency rate did not differ significantly according to either type (p = 0.37) or method (p = 0.62). Conclusion: For good initial patency, the transpapillary method is recommended for strictures of the distal extrahepatic duct near the ampulla and just above the bending portion. Long-term patency is not influenced by the stenting method employed.

  • PDF

Serious Complications after Self-expandable Metallic Stent Insertion in a Patient with Malignant Lymphoma

  • Cho, Sung Bae;Cha, Seon Ah;Choi, Joon Young;Lee, Jong Min;Kang, Hyeon Hui;Moon, Hwa Sik;Kim, Sei Won;Yeo, Chang Dong;Lee, Sang Haak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.1
    • /
    • pp.31-35
    • /
    • 2015
  • An 18-year-old woman was evaluated for a chronic productive cough and dyspnea. She was subsequently diagnosed with mediastinal non-Hodgkin lymphoma (NHL). A covered self-expandable metallic stent (SEMS) was implanted to relieve narrowing in for both main bronchi. The NHL went into complete remission after six chemotherapy cycles, but atelectasis developed in the left lower lobe 18 months after SEMS insertion. The left main bronchus was completely occluded by granulation tissue. However, the right main bronchus and intermedius bronchus were patent. Granulation tissue was observed adjacent to the SEMS. The granulation tissue and the SEMS were excised, and a silicone stent was successfully implanted using a rigid bronchoscope. SEMS is advantageous owing to its easy implantation, but there are considerable potential complications such as severe reactive granulation, stent rupture, and ventilation failure in serious cases. Therefore, SEMS should be avoided whenever possible in patients with benign airway disease. This case highlights that SEMS implantation should be avoided even in malignant airway obstruction cases if the underlying malignancy is curable.