• 제목/요약/키워드: Self-expandable metallic stent

검색결과 31건 처리시간 0.026초

A remnant choledochal cyst after choledochal cyst excision treated with a lumen-apposing metal stent: a case report

  • Bo Kyung Kim;Jung Won Chun;Sang Hyub Lee;Ji Kon Ryu;Yong-Tae Kim;Woo Hyun Paik
    • Clinical Endoscopy
    • /
    • 제55권4호
    • /
    • pp.564-569
    • /
    • 2022
  • A lumen-apposing metal stent (LAMS) is a saddle-shaped stent with large flanges at both ends, thereby preventing stent migration and helping with approximation of the adjacent structures. We report the case of a 25-year-old female with remnant choledochal cyst which was successfully treated with LAMS after initial treatment failure with a plastic stent. Although complete excision of the cyst is the definite treatment of choledochal cysts, endoscopic ultrasonography-guided cystoduodenostomy can be considered in cases wherein surgery is not feasible and dysplasia is not present. LAMS may be preferred to plastic stents for effective resolution of remnant choledochal cyst and prevention of ascending infection.

Portal cavernography during endoscopic retrograde cholangiopancreatography: from bilhemia to hemobilia

  • Rawad A. Yared;Paraskevas Gkolfakis;Arnaud Lemmers;Vincent Huberty;Thierry Degrez;Jacques Deviere;Daniel Blero
    • Clinical Endoscopy
    • /
    • 제56권4호
    • /
    • pp.521-526
    • /
    • 2023
  • Portobiliary fistulas are rare but may lead to life-threatening complications. Biliary plastic stent-induced portobiliary fistulas during endoscopic retrograde cholangiopancreatography have been described. Herein, we present a case of portal cavernography and recurrent hemobilia after endoscopic retrograde cholangiopancreatography in which a portobiliary fistula was detected in a patient with portal biliopathy. This likely indicates a change in clinical presentation (from bilhemia to hemobilia) after biliary drainage that was successfully treated by placement of a fully covered, self-expandable metallic stent.

Covered self-expandable metallic stents versus plastic stents for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction

  • Taro Shibuki;Kei Okumura;Masanari Sekine;Ikuhiro Kobori;Aki Miyagaki;Yoshihiro Sasaki;Yuichi Takano;Yusuke Hashimoto
    • Clinical Endoscopy
    • /
    • 제56권6호
    • /
    • pp.802-811
    • /
    • 2023
  • Background/Aims: Covered self-expandable metallic stents (cSEMS) have become popular for endoscopic ultrasound-guided hepaticogastrostomy with transmural stenting (EUS-HGS). We compared the time to recurrent biliary obstruction (TRBO), complications, and reintervention rates between EUS-HGS using plastic stent (PS) and cSEMS in patients with unresectable malignancies at multicenter institutions in Japan. Methods: Patients with unresectable malignant biliary obstruction who underwent EUS-HGS between April 2015 and July 2020 at any of the six participating facilities were enrolled. Primary endpoint: TRBO; secondary endpoints: rate of complications other than recurrent biliary obstruction and technical success rate of reintervention were evaluated. Results: PS and cSEMS were used for EUS-HGS in 109 and 43 patients, respectively. The TRBO was significantly longer in the cSEMS group than in the PS group (646 vs. 202 days). Multivariate analysis identified two independent factors associated with a favorable TRBO: combined EUS-guided antegrade stenting with EUS-HGS and the use of cSEMS. No significant difference was observed in the rate of complications other than recurrent biliary obstruction between the two groups. The technical success rate of reintervention was 85.7% for PS and 100% for cSEMS (p=0.309). Conclusions: cSEMS might be a better option for EUS-HGS in patients with unresectable malignancies, given the longer TRBO.

Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review

  • Yuki Tanisaka;Masafumi Mizuide;Akashi Fujita;Rie Shiomi;Takahiro Shin;Kei Sugimoto;Shomei Ryozawa
    • Clinical Endoscopy
    • /
    • 제56권6호
    • /
    • pp.716-725
    • /
    • 2023
  • Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is technically challenging. For example, scope insertion, selective cannulation, and intended procedures, such as stone extraction or stent placement, can be difficult. Single-balloon enteroscopy (SBE)-assisted ERCP has been used to effectively and safely address these technical issues in clinical practice. However, the small working channel limits its therapeutic potential. To address this shortcoming, a short-type SBE (short SBE) with a working length of 152 cm and a channel of 3.2 mm diameter has recently been introduced. Short SBE facilitates the use of larger accessories to complete certain procedures, such as stone extraction or self-expandable metallic stent placement. Despite the development in the SBE endoscope, various steps have to be overcome to successfully perform such procedure. To improve success, the challenging factors of each procedure must be identified. At the same time, endoscopists need to be mindful of adverse events, such as perforation, which can arise due to adhesions specific to the surgically altered anatomy. This review discussed technical tips regarding SBE-assisted ERCP in patients with surgically altered anatomy to increase success and reduce the risk of adverse events associated with ERCP.

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • 제12권6호
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study

  • Takeshi Okamoto;Takashi Sasaki;Tsuyoshi Takeda;Tatsuki Hirai;Takahiro Ishitsuka;Manabu Yamada;Hiroki Nakagawa;Takafumi Mie;Takaaki Furukawa;Akiyoshi Kasuga;Masato Ozaka;Naoki Sasahira
    • Clinical Endoscopy
    • /
    • 제57권4호
    • /
    • pp.515-526
    • /
    • 2024
  • Background/Aims: The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO). Methods: Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared. Results: Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7% vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS. Conclusions: No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.

외상 후 단독 상장간막동맥박리 후에 국소적으로 진행된 박리성 동맥류와 심한 진강의 압박이 있는 환자에서 혈관내 스텐트설치술 1례 (Endovascular Stent Placement in a Patient with a Posttraumatic Isolated Superior Mesenteric Artery Dissection with Focally Progressing Dissecting Aneurysms and a Severely Compressed True Lumen)

  • 김영규;허규희;김승형;김광식
    • Journal of Trauma and Injury
    • /
    • 제28권4호
    • /
    • pp.266-271
    • /
    • 2015
  • Reports on a posttraumatic isolated superior mesenteric artery (SMA) dissection are rare. Recently, endovascular stent placement via percutaneous access, instead of vascular surgery, has been widely accepted as the initial treatment for a patient with an isolated SMA dissection or its complications. A 60-year-old female patient was transferred to our hospital due to an isolated SMA dissection after a car accident. The SMA dissection was 8.5 cm in length, and it involved the true lumen, which was severely compressed by the thrombosed false lumen. The patient was closely observed because she did not complain of any specific visceral pain. On the seventh hospital day, she underwent computed tomography (CT) to decide on a further treatment plan, irrespective of the presence of the abdominal symptom. The findings of the follow-up CT showed no difference compared to those of the previous CT. She was discharged with anti-coagulants. One month later, the follow-up CT revealed focally progressing dissecting aneurysms in the false lumen of the dissected SMA and a more severely compressed true lumen. Two self-expandable metallic stents were successfully placed in the true lumen of the dissected SMA, covering two aneurysmal lesions. Herein, we report a successful endovascular treatment with stent placement for treating focally progressing dissecting aneurysms and a severely compressed true lumen in a patient with a posttraumatic isolated SMA dissection.

  • PDF

악성대장협착의 근치적 절제술을 위한 수술 전 투시장치 하 스텐트 설치술: 단기 및 장기 결과 (Fluoroscopic Stent Placement as a Bridge to Surgery for Malignant Colorectal Obstruction: Short- and Long-Term Outcomes)

  • 윤종혁;정규식
    • 대한영상의학회지
    • /
    • 제84권3호
    • /
    • pp.615-626
    • /
    • 2023
  • 목적 악성대장협착에서 스텐트 설치 후 시행한 단단계 수술의 결과를 평가하고자 하였다. 대상과 방법 2009년 1월부터 2018년 1월까지, 악성대장협착으로 투시장치 하 스텐트를 설치하여 장세척을 한 후 수술을 시행한 46명의 환자(남:여 = 28:18, 평균 67.2세)를 대상으로 하였다. 그중 31명은 복강경수술, 15명은 개복수술을 시행하였으며, 수술 결과를 후향적으로 분석하였다. 평균 38.9개월의 추적관찰 기간 동안, 무재발생존율과 전체생존율을 구하였고, 예후인자를 알아보았다. 결과 스텐트 설치 후 평균 10.2일 후에 수술을 시행하였으며, 전례에서 성공적으로 스텐트를 포함한 종양 절제 후 문합이 가능하였다. 수술 후 평균 입원기간은 11일이었다. 6명의 환자(13%)에서 수술 중 혹은 수술 후 병리 소견에서 장천공이 관찰되었다. 추적 기간 동안 10명의 환자(21.7%)에서 종양이 재발하였으며, 장천공이 관찰되었던 6명의 환자 중 5명에서 재발이 발생하였다. 장천공은 무재발생존율에 유의미한 영향을 미쳤다(p = 0.010). 결론 악성대장협착에서 스텐트 설치 후 시행한 단단계 수술은 효과적인 치료 방법으로 생각된다. 스텐트와 연관된 장천공이 재발의 위험인자였다.

소화기 종양에 대한 내시경적 완화치료 (The Role of Endoscopic Interventions in Palliative Care for the Gastrointestinal Tumors)

  • 김혜강;정대영
    • Journal of Digestive Cancer Research
    • /
    • 제2권1호
    • /
    • pp.1-4
    • /
    • 2014
  • Palliative care for cancer aims to relieve the discomfort and pain from the cancer itself and associated conditions. Gastrointestinal cancers originate from the tube like structure of gastrointestinal tract and cause complications such as obstruction, bleeding, adhesion, invasion, and perforation to adjacent organ. Recent advances in interventional endoscopy enables endoscopy physicians to do safe and effective care for gastrointestinal cancer patients. Endoscopic palliation includes stent, hemostasis, nutritional support and targeted drug delivery. Self expandable metallic stent is one of the most important modalities in gastrointestinal palliation. Through the endoscopy or over the wire pre-placed by endoscopy, stents restore the gastrointestinal luminal patency and relieve the obstructive condition. Endoscopic hemostasis is another important palliation in gastrointestinal cancer patients. Epinephrine injection, argon plasma coagulation and thermal cauterization are usual modalities for hemostasis. Histoacryl glue and fibrin glue are also available. Hemostatic nanopowder spray is newly reported effective in benign disease and is supposed to be effective also in cancer bleeding. Enteral feeding tubes including gastro- or jejunostomy and nosoduodenal tubes are placed by using endoscopic guidance. Enteral feeding tubes role as the route of easily absorbable or semi-digested nutrients and effectively maintain both patients calorie requirements and gut microenvironment. Photodynamic therapy is the one of the outstanding medical employments of photo-physics. Especially for superficial cancers in esophagus, photodynamic therapy is very useful in cancer removal and maintaining organ structure. In biliary neoplasm, photodynamic therapy is well known to be effective in cancer ablation and biliary ductal patency restoration. Targeted drug delivery is the lastest issue in palliative endoscopy. Debates and questions are still on the table. In this article, the role of endoscopic interventions in palliative care for the gastrointestinal tumors will be thoroughly reviewed.

  • PDF

Percutaneous Placement of Self-expandable Metallic Biliary Stents in Malignant Extrahepatic Strictures: Indications of Transpapillary and Suprapapillary Methods

  • Deok Hee Lee;Jeong-Sik Yu;Jae Cheol Hwang;Ki Hwang Kim
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.65-72
    • /
    • 2000
  • Objective: To compare the efficacy of suprapapillary and transpapillary methods of transhepatic biliary metallic stent placement in malignant biliary strictures and to specify the indications of each method applied. Materials and Methods: Stents were placed in 59 patients. Strictures were categorized as type A (within 3 cm of the ampulla, n = 27), type B (over 3 cm from ampulla, n = 7), type C (within 3 cm of the bending portion, n = 9), or type D (over 3 cm above the bending portion, n=16). The stenting method was suprapapillary in 34 cases and transpapillary in 25. The rates of initial and long-term patency and of early recurrence were compared. Results: Initial patency rates for the suprapapillary and transpapillary methods were 1/7 (14.3%) and 20/20 (100%) respectively for type A (p < 0.0001), 4/5 (80.0%) and 2/2 for type B, 3/7 (42.9%) and 2/2 for type C, and 15/16 (93.8%) and 0/0 for type D. Early recurrence rates were 7/30 (23.3%) using the suprapapillary method and 4/29 (13.8%) using the transpapillary method (p = 0.51). The long-term patency rate did not differ significantly according to either type (p = 0.37) or method (p = 0.62). Conclusion: For good initial patency, the transpapillary method is recommended for strictures of the distal extrahepatic duct near the ampulla and just above the bending portion. Long-term patency is not influenced by the stenting method employed.

  • PDF