• Title/Summary/Keyword: Self-Conditioning

Search Result 96, Processing Time 0.028 seconds

Static Characteristics of Electro-Hydraulic Spring Return Actuator (전기유압식 스프링복귀 액추에이터 정특성)

  • Jung, G.H.
    • Journal of Drive and Control
    • /
    • v.9 no.2
    • /
    • pp.8-14
    • /
    • 2012
  • Electro-hydraulic spring return actuator(ESRA) is utilized for air conditioning facilities in a nuclear power plant. It features self-contained, hydraulic power that is integrally coupled to a single acting hydraulic cylinder and provides efficient and precise linear control of valves as well as return of the actuator to the de-energized position upon loss of power. In this paper, the algebraic equations of ESRA at steady-state have been developed for the analysis of static characteristics that includes control pressure and valve displacement of pressure reducing valve, flow force on flapper as well as its displacement over the entire operating range. Also, the effect of external load on piston deviation is investigated in terms of linear system analysis. The results of static characteristics show the unique feature of force balance mechanism and can be applied to the stable self-controlled mechanical system design of ESAR.

Investigation on the Self-Pressurization in Cryogenic Liquid Storage System (극저온 유체 저장 시스템의 압력 증가에 대한 연구)

  • Seo, Man-Su;Kim, Young-Kwon;In, Se-Hwan;Jeong, Sang-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.142-147
    • /
    • 2008
  • This paper reports an analysis of self-pressurization in a closed cryogenic liquid storage system and its comparison with experimental data using liquid nitrogen. Partial equilibrium model(PEM), revised thermodynamic analysis of homogeneous model, has been applied for the pressurization in a closed tank. The vapor and liquid bulk temperature and the liquid-vapor interface temperature are separately calculated as their own representative values in this analysis. The analysis results of the partial equilibrium model are compared with the experimental data and other preceding homogeneous temperature models for validation.

  • PDF

Development of Smart PCS(Power Conditioning System) Integrating PV/ESS for Home (가정용 태양광/ESS 통합 스마트 PCS 개발)

  • Lee, Sang-Hak
    • Journal of Digital Convergence
    • /
    • v.14 no.7
    • /
    • pp.193-200
    • /
    • 2016
  • Research and development of energy self-consumption introducing photovoltaic and energy storage system at home is very active. This system can manage the home energy in which it charges the electricity generated during the day and uses it during high electricity bills. However, it not yet made up the residential real-time pricing in Korea but it can reduce electricity usage to a certain target on the progressive. In order to introduce the home photovoltaic, it requires PCS(Power Conditioning System). This converts the direct current into alternating current by the electricity generated and used to perform charging and discharging of the energy storage system. The market for self-consumption smart home system is currently increasing because the interests of the general public about solar power, energy storage systems increased. The result of this study is installed on the room environment and the effect was analyzed on the assumption of real-time pricing.

Association Between Air Conditioning Use and Self-reported Symptoms During the 2018 Heat Wave in Korea

  • Lee, Yong-Han;Bae, Sanghyuk;Hwang, Seung-sik;Kim, Jong-Hun;Kim, Kyoung-Nam;Lim, Youn-Hee;Kim, Miji;Jung, Sohwa;Kwon, Ho-Jang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.53 no.1
    • /
    • pp.15-25
    • /
    • 2020
  • Objectives: The purpose of this study was to investigate the health effects of air conditioning use during the 2018 heat wave in Korea, included the highest temperature ever recorded in the nation. Methods: The participants in this study were 1000 adults aged 19 years and older recruited from across Korea. The participants were asked about their experience of symptoms of various diseases, disruptions of their daily lives, and use of air conditioning during the heat wave. The associations between air conditioning use during the heat wave and health outcomes were analyzed using the chisquare test and multiple logistic regression models. Results: Among participants who lacked air conditioning in the main space where they spent time outside the home, 33.9%, 8.1%, 43.5%, and 19.4% experienced symptoms of heat-related, cardiovascular, nervous system diseases, and air-conditioningitis, respectively. In comparison, participants who did have air conditioning outside the home experienced the same symptoms at proportions of 21.0%, 1.9%, 26.8%, and 34.2%, respectively (p=0.027, 0.007, 0.007, and 0.023, respectively). Among participants who had no air conditioner at home, 10.0% were absent from school or work due to the heat wave. In contrast, among participants who had an air conditioner at home, only 3.7% were absent as a result of the heat wave (p=0.007). Conclusions: When air conditioning was not used at home or in the main space where participants spent time outside the home during the 2018 heat wave, adverse health effects were more prevalent, but the risk of air-conditioningitis was reduced.

A Study on Heat Transfer of an Underground Power Transmission Cable-Joint (지중송전케이블 접속부에서의 열전달에 관한 연구)

  • Park, M.H.;Kim, J.K.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.265-277
    • /
    • 1993
  • Recently, underground transmission system is growing continuously according to the electric power demand increase in the downtown area. Even if domestic cable makers are manufacturing 154kV oil filled cable and joint, the design technology of cable-joint has not been fully self-reliance. This study is aimed at the detail heat transfer analysis of 154kV cable-joint. So, that is cut into the five sections in order to analyze a conjugate natural convection in two dimensional $r-{\theta}$ coordinate. The streamline and temperature distributions are obtained for each sections. Also the changes of those are analyzed with respect to the variation of transmission currents and cable-joint surface heat transfer coefficients. The same analyses are also shown in view point of the maximum temperature of conductor and local equivalent conductivity.

  • PDF

Mechanism of Fouling Reduction and Heat Transfer Enhancement in a Circulating Fluidized Bed Heat Exchanger (순환유동층 열교환기 내의 화울링 저감 및 열전달 향상 기구)

  • Lee, Y.P.;Yoon, S.Y.;Jurng, J.S.;Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.450-460
    • /
    • 1995
  • A modified circulating fluidized bed heat exchanger under severe fouling condition is developed. The effects of fouling deposits on the performance of a heat exchanger are investigated. The principle and operating characteristics of a circulating fluidized bed heat exchanger are dicussed. A modified circulating fluidized bed heat exchanger shows more stable operating than the other circulating fluidized bed heat exchanger. The characteristics of self cleaning and heat transfer enhancement of a circulating fluidized bed heat exchanger are studied. The movement of spherical particles in a tube is visualized and heat transfer enhancement and scale reduction mechanism by particles are investigated.

  • PDF

A Study on the Major Building Material and Construction Method Influencing to IAQ through Full-Scale House Construction (실물 주거 시공을 통한 실내공기질에 영향을 미치는 주요 건축자재 및 시공방법에 관한 연구)

  • Yu Hyung-Ku;Park Jin-Chul;Rhee Eon-Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.262-269
    • /
    • 2006
  • Formaldehyde and total volatile organic compounds (TVOC) from building materials have been known as main causes of IAQ problem in Newly-Constructed Multi-Family Houses. Because Multi-Family Houses are built in large quantities in a similar manner, inappropriate selection of building materials and method will detrimental affect IAQ. This research aims to identify major causes of Indoor Air Pollutants in Multi-Family Houses, by constructing Mock-Up & One-Room House. As a result, self leveling concrete, door, and furniture construction is a major cause of indoor formaldehyde increase, and tile bond is TVOC, and urethane water proof is Etylbenzene, and Xylene.

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

The Effect of Aerobic Rhythmical Exercise Program on Physical Fitness, Self-efficacy and Quality of Life in Elderly (유산소 리듬 운동프로그램이 노인의 체력, 자기효능감 및 삶의 질에 미치는 효과)

  • Kim Jong Hwa;Park Young Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.14 no.1
    • /
    • pp.12-25
    • /
    • 2000
  • The purpose of this study was to determine the effects of aerobic rhythmical exercise program on $VO_2$ max, leg strength, grip strength, flexibility, exercise self-efficacy and quality of life in elderly. This quai-experimental study was designed as a non-equivalent control group pretest-posttest study. 36 subjects, aged between 65 and 73 years who have normal cognition. sensory function and cerebellum function participated in this study. 19 experimental group subjects participated aerobic rhythmical exercise program. Aerobic rhythmical exercise program was developed on the basis of calisthenics, stretching, aerobic exercise, Korean traditional dance and music by the author. The program consisted of approximately 1 hours of exercise, 3 times a week for 9 weeks. During 1 hours workout, there were 15 minutes of warm-up dancing, 35 minutes of conditioning dance and 10 minutes of cool-down dancing. The intensity for the conditioning phase was between $40\%\;and\;60\%$ of age adiusted maximum heart rates. The $VO_2$ max, grip strength, leg strength, flexibility, exercise self-efficacy and quality of life were measured prior to and following the experimental treatment. Data were analyzed with $x^2-test$, t-test, mean, standard deviation. percentage of change and ANCOVA test using SAS program. Results were obtained as follows. 1. The $VO_2$ max of the experimental group were significantly lower than those of the control group following the aerobic rhythmical exercise program(F=7.76, p=0.008). 2. The grip strength of the experimental group were significantly lower than those of the control group following the aerobic rhythmical exercise program(F=4.61, p=0.039). 3. The leg strength of the experimental group were significantly lower than those of the control group following the aerobic rhythmical exercise program(F=9.29, p=0.000). 4. The was no significantly difference of flexibility between experimental and control group 5. The self-efficacy of the experimental group were significantly lower than those of the control group following the aerobic rhythmical exercise program(F=43.40, p=0.000). 6. The quality of life of the experimental group were significantly lower than those of the control group following the aerobic rhythmical exercise program(F=8.91. p=0.005). The results suggest that aerobic rhythmical exercise program can improve $VO_2$ max, grip strength. leg strength. exercise self-efficacy and quality of life elderly. Thus. aerobic rhythmical exercise program was a useful nursing intervention for elderly.

  • PDF

A study on the control of HVAC system (HVAC시스템의 제어에 관한 연구)

  • 홍규장;박성기;송언빈;정찬수
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.57-62
    • /
    • 1990
  • This paper describes the development and testing of a degitial controller for heat-ing ventilating and air-conditioning system. The controller uses properational-integral control action and self tunes to provide the Zigeler-Nichols when given a step input. The algorithm has been simulated fas static pressure.

  • PDF