• Title/Summary/Keyword: Self cleaning

Search Result 230, Processing Time 0.029 seconds

A Study on Self Care Compliance Related to Infection Management for Continuous Ambulatory Peritoneal Dialysis Patients (복막투석환자의 감염예방과 관련된 자가간호 이행에 관한 연구)

  • Lee Eun-Young;Kim Jung-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 1998
  • This study was a descriptive research on the level of self-care available to continous ambulatory peritoneal dialysis patients (hereinafter referred to as 'CAPD patient') related to the specific area of infection management. The method employed for the collection of data was a modified instrument of the self-care survey essentially based on Young Sook Choi's instrument. The relevant data was collected from september 1, 1996 to september 30, 1996. The subjects were provided with an open-ended question regarding the reasons behind why they did not seek self-care. The answers provided about self-care compliance were analyzed by SPSS for frequency, percentage, mean, t-test, ANOVA. Reasons for non-compliance were analyzed by content analysis. The results of the study were as follows : 1. The percentage of patients engaging in self-care were according to the following self performed tasks : preparation of dialysis : 30.58 points Dialysate exchange procedures : 49.40 points - Two bag type : 50.50 points - Spike type : 48.80 points - Neo type : 48.90 points Catheter exit site care : 25.13 points More specifically, in relation to the preparation of dialysis as referred to above, those patients engaging in self care was relatively high with respect to the cleaning of the dialysis before use and for the preservation of peritosol. However, in dialysate exchange procedures, data revealed that those patients engaging in self-care are relatively low with respect to putting on a mask during the performance of peritosol exchange. Similary in peritosol exchange procedure and catheter exit care, low levels of self-care performance were found in the area of putting on a mask during the peritosol exchange procedures and catheter line testing procedures, respectively. 2. In general characteristics, there appeared to be no distinction in self-care compliance among CAPD patients. 3. The main reasons for non-compliance were based in the following factor : intellectual, attitude, enviromental surrounding and physical. As a result of the foregoing finding, nurses should provide adequate assistance to promote self-care compliance by CAPD patients by checking the preparation of dialysis, dialysate exchange procedure, and catheter exit site care which recieved low point in this research.

  • PDF

Evaluation of Worker's Health and Occupational Exposure to Perchloroethylene in Laundries (Perchlotoethylene을 사용하는 세탁소 작업자들의 직업성 폭로와 건강에 관한 연구)

  • An, Sun-Hee;Lee, Jong-Hwoa;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.224-239
    • /
    • 1994
  • In this study we examined several subjective symptoms in an exposed group and an unexposed group to perchloroethylene. The exposed group consists to 30 workers employed in 23 dry-cleaning establishments located in Chung Cheung Do, whereas the unexposed group consists of 42 officers employed in a certain university. This study was conducted from October, 1993 to March, 1994. Also we investigated personal exposure levels and area concentration of PCE, and performed hematological and biochemical examination in blood and urine samples from the exposed group. The results are : 1. The exposed group highly complains several subjective symptoms, particularly in neuropsychiatry, eye, respiratory system and digestive system, compared with the unexposed group. But complaint rates in the exposed group are not related with PCE exposure levels. 2. PCE exposure levels for all dry-cleaning establishment varied widely, from 0.18 to 37.58ppm. The mean exposure level for centers of chain was 16.85ppm, and for local laundries was 8.83ppm, while for self-service establishment it was 3.07ppm. Eighty three percent of the workers were exposed less than the half-level(25.0ppm) of the Korea 50.0ppm standard for eight-hour PCE exposure. Seventeen percent of them exceeded the half-level of the Korea TLV. 3. Statistical correlation exists between the work load(number of operation cycles of equipment and the mass of processed textiles) and the personal exposure levels to be observed. 4. In hematological examination the values of WBC, RBC, Hgb, Hct, MCV, MCH, MCHC and PLT in the exposed group were within normal ranges. In biochemical examination(GOT, GPT, ALP, U-A and LDH) most of the items were within normal ranges. From this surveys conducted on 23 dry-cleaning establishments, the complaint rates of the exposed group to PCE in several subjective symptoms were higher than those of the unexposed group, and PCE exposure levels in all dry-cleaning establishment were below the Koera standard 50.0ppm. In hematological and biochemical examination the significant abnormalities by occupational exposure to PCE were not observed. However, the workers employed in dry-cleaning establishments are always faced with risk, becauses they are also exposed to several organic solvents used to remove stains. Therefore, various measures to improve occupational environment in dry-cleaning establishment should be considered.

  • PDF

Checklist and Design Recommendations for the Interiors of Korean, Eco-healthy Childcare Facilities (우리나라 영유아 보육시설의 친환경 실내를 위한 체크리스트와 디자인안 제안)

  • Chun, Jin Hie
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.105-114
    • /
    • 2010
  • As children are known to touch and chew everything, green cleaning procedures are an important step in preventing children from ingesting harmful toxins. The objectives of this study are to develop a new, self-evaluation checklist and to suggest design recommendations which comply with easy, adaptable, economical ways to improve the eco-friendly indoor environment of Korean childcare facilities. The information compiled during this study was collected through literature review and internet surveys1) from July, 2009 to February, 2010. The results of this study show that the current Korean childcare accreditation system and practices emphasize clean building interiors, policies for sanitation and cleanliness, and control of humidity and lighting. On the other hand, the information provided by green-building rating systems from GBCC, LEED, and GBTool offers additional and comparative details regarding indoor environment quality and standards regarding the IAQ performance and management plan, ventilation and thermal comfort systems, views from windows, acoustics, and lighting. In conclusion, this document provides an appropriate and easy-to-follow, self-evaluation checklist composed of eight criteria and 51 practical items. This study also provides the design recommendations composed of 27 practical ideas focusing on interior elements. Both the checklist and design recommendations I have suggested can be a post-occupancy tool for evaluating eco-healthy facility standards as well as tips for continuing to maintain eco-healthy childcare facilities.

Characterization of a Functional Coating Film Synthesized on the Ceramic Substrate for Electrical Insulator Application according to Coating Method

  • Shan, Bowen;Kang, Hyunil;Choi, Wonseok;Kim, Jung Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.148-150
    • /
    • 2017
  • For the improvement of the anti-fouling features of porcelain electrical insulators, in this study, the surface of an insulator was coated with a functional material to expand the insulator's self-cleanness. The anti-fouling and mechanical features of the functional film coating of ceramic substrates made from components like an electrical insulator were analyzed. The coating methods that were used were spray coating, dip coating, and fabric coating. Following the coating, the contact angle of the coated surface was measured, revealing that the spray coating method offered the lowest angle ($13.7^{\circ}$) and a strong hydrophilic feature. The anti-fouling analysis showed that the anti-fouling features improved as the contact angle decreased. The mechanical properties - hardness and adhesion - were both excellent at 9H and 5B, respectively, regardless of the coating method that was used.

Surface Modification of Functional Titanium Oxide to Improve Corrosion Resistance (내식성 향상을 위한 기능성 타이타늄 표면 개질)

  • Park, Youngju;Jeong, Chanyoung
    • Corrosion Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.256-265
    • /
    • 2021
  • Titanium is applied in various industries due to its valuable properties and abundant reserves. Generally, if a highly uniform oxide structure and a high-density oxide film is formed on the surface through anodization treatment, the utility value such as color appearance and corrosion inhibition efficiency is further increased. The objective of this study was to determine improvement of water-repellent property by controlling titanium oxide parameters such as pore size and inter-pore distance to improve corrosion resistance. Oxide film structures of different shapes were prepared by controlling the anodization processing time and voltage. These oxide structures were then analyzed using a Field Emission Scanning Electron Microscope (FE-SEM). Afterwards, a Self-Assembled Monolayer (SAM) coating was performed for the oxide structure. The contact angle was measured to determine the relationship between the shape of the oxide film and the water-repellency. The smaller the solid fraction of the surface, the higher the water-repellent effect. The surface with excellent hydrophobic properties showed improved corrosion resistance. Such water-repellent surface has various applications. It is not only useful for corrosion prevention, but also useful for self-cleaning. In addition, a hydrophobic titanium may open up a new world of biomaterials to remove bacteria from the surface.

A Study of Korean Costume in the Collection of Overseas Museums (해외 박물관 소장 한국 복식문화재에 관한 연구)

  • 윤은재;임영자
    • Journal of the Korean Society of Costume
    • /
    • v.36
    • /
    • pp.219-238
    • /
    • 1998
  • For the purpose of this Study, the situation of Korean costume properties in the collection of overseas museums was investigated through correspondence, interviews with their curators and persons in charge and survey. As results were made about the situation of museum science (conservation) and practical utilization of costume properties. So, the study result were drawn as follows : Krean costume properties unexplaind of 'Korean cultural Properties' could be found in the Metropolitan Museum of Art of New York(135 pieces), the Brooklyn Museum of New York(20 pieces), the Newark Museum of New Jersey(15 pieces), and the Victoria Albert Museum of London(100 pieces). Korean costume properties in the collection of over-seas museums mostly fall under the rang of period between the 19th century and the early 20th century and are classified into everyday clothing, wedding costume and armors for the most part. In 1900s, museum in several countries began to collected Korean cultural properties through foreign missionaries or diplomats as well as merchants or travellers in who bought Korean objects. Recently, scholars, traditional Korean costume designerss and diplomatic and consular offices in overseas have donated our Korean costume to many foreign museums. Korean costume properties were largely on display in the dependent display of folklore museums or in a part of exhibition gallery for Asian culture and there were the separate exhibition rooms in museums in the United Kingdom, Germany, Denmark, Austria, Japan and the United States America. But the size and level of display room for Korean cultural properties is one third as large as that for chinese or Japanese cultual properties. It was found in this study that the traditional Korean costume in the collection of overseas museums was largely recorded only as general items rather than given their proper names. The typical example of misnaming included bridal's Kimono for Wonsam(원삼) in the Metropolitan Museum of Art, Yeonroksaek-bumunsajeokori for Dangeui(당의) and Jissan-gryongwonmunsadurumagi for Kongdali(동달이) in the Okura collection of the Tokyo National Museum, and so on. And the Victoria Albert Museum modified the way of wearing Daenim(대님) and the National Museum of Ethnology in Osaka seemed to misplace the ornament of Keanggi(댕기) on Mubok(무복) and Josunjuk(조선족: Chinese-Korean) Museum also misplace hansam(한삼). On the one hand, the Newark museum of New Jersey mixed Chinese armor with the Korean one and the Photohraph of King Kojong(고종) with Chinese one. It is corrected to publish and disseminate the book concering Korean costume in order to inform foreign museums of thed proper names and wearing method of our traditional costumed. The repair of costume before cleaning in the process of conservation treatment can prevent damage likely to occur as the properties of fiber itself are weakened in liquid. It is recommended that western 8-figure stitch and tacking stitch is added to Korean traditional stitching method. Museums in the U.S.A and the U.K are concerned about the aftermath of cleaning it-self, specially conservation treatment may exert on remains and predominantly use the vacuuming method to remove dust or bits of straw before the exhibition beings. But in case of Korea, the dry cleaning and wet cleaning method are used according to the nature and state of a sample costume. This comprehensive cleaning method is gradually developing scientifically but it is expected that those concerned will make a chemical analysis of the solvent to be used and also the more precise test of costume properties will be conducted before cleaning them. A partial study was made here because the scope of study was too broad and vast. It is expected that more studies will be conducted concerning our costume culture under the long-term plan and active support at the government level.

  • PDF

초소수 실리카 코팅층 제조와 표면 특성

  • Kim, Ji-Yeong;Kim, Sang-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.123-123
    • /
    • 2012
  • 초소수성 표면은 150도 이상의 높은 물 접촉각과 10도 이하의 낮은 sliding angle을 가지며 self-cleaning, anti-contamination 기능을 갖고 있는 것이 특징이다. 재료표면의 친수성과 소수성을 제어하기 위해서는 화학적 인자인 물질의 표면에너지나 물리적 인자인 표면 거칠기를 조절하는 방법이 있다. 초소수성 표면을 구현하기 위해서는 표면의 거칠기를 증가시키거나 표면 에너지를 낮춰야 하는데 고체 표면의 거칠기를 증가시키기 위해서는 일반적으로 표면에 microscale과 nanoscale의 계층구조를 형성시키는 방법이 사용된다. 자연계에 매우 풍부하게 존재하는 실리카는 내구성과 내마모성, 화학적 안정성, 고온 안정성 등을 지니고 있으며 인체에 무해하기 때문에 다양한 종류의 전자기기 및 부품의 내외장 코팅에 적용이 검토되고 있다. 이러한 관점에서 본 연구에서는 초소수성 코팅층을 구현하는 하나의 방법으로서 졸-겔방법으로 실리카 졸을 합성하여 전기분무법을 사용하여 microscale의 실리카 입자 코팅층을 형성하였으며, 표면 미세구조 조절 및 계층구조 형성과 불소화처리 공정을 통하여 초소수성 실리카 코팅층을 제조하였다. 이러한 초소수성 실리카 코팅층의 표면거칠기, 자외선 영향향, 내구성 등을 초소수성 관점에서 평가하였다.

  • PDF

Effect on Customer Satisfaction of the Emotional Intelligence of Members at Service Providing Department in the Hotel; A Case of Five Star Hotels in Daejeon

  • Kim, Jung-Soo
    • Culinary science and hospitality research
    • /
    • v.22 no.1
    • /
    • pp.126-134
    • /
    • 2016
  • This study examines effect in customer satisfaction of the emotional intelligence of members at service providing department in the hotel; A case of five star hotels in Dajeon Research hypotheses were developed based on previous literature, and data were collected from 350 employees working at the hotel restaurant service business located in Daejeon, ROK, were investigated herein The collected data were then analysed using frequence reliability For this research analysis, a self-recording method was used where and examiner explains the survey and respondents writhen down their answers to survey questions Statistical processing in this study was done through data cidubg and data cleaning then with the SPSS(Statistical Package for Social Science)v. 18.0. This result the emotional intelligence of service-providing employees at food service department of hotel was found to have a positive effect on customer satisfaction via understanding of others and emotional control. And the understanding of oneself, understanding of others and emotional control in emotional intelligence had a positive effect on job satisfaction. Emotional control, and emotioal use were found to affect organizational commitment positively.

New Field in Photoelectrochemistry: Photocatalytic, Super-hydrophilic and Super-hydrophobic Functions of $TiO_2$ Coatings

  • Fujishima Akira;Hashimoto Kazuhito
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.81-84
    • /
    • 2000
  • This article deals with various photochemical processes occurring at $TiO_2$ surface and its applications in practical living conditions. In the first part, we present an overview of $TiO_2$ photocatalysis under weak W illumination with a special emphasis on bactericidal and detoxification properties of $TiO_2$ films. The second part deals with the photoinduced super hydrophilic TiCt surftce which has a wide commercial applications. In the last part, we present our recent work on boehmite-based super hydrophobic surfaces containing small amount of $TiO_2$ to obtain self-cleaning effect.

The Preparation of Rosewood Microcapsules by Interfacial Polymerization and Aromatic, Antimicrobial Finishing of Wool Fabric (계면중합에 의한 로즈우드 마이크로캡슐 제조 및 방향.항균가공)

  • 김현진;송화순
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.200-208
    • /
    • 2003
  • The purpose of this study is to propose scientific data and to develop complex\ulcornermultifunctional fibers by applying microcapsules containing rosewood oil on wool fabric. Polyurea was used as wall material of microcapsules. The parameters for adoptable condition are 20min of agitation time, 5000rpm of agitation speed, 4% of emulsifier concentration according to the observation with SEM and particle analyzer. The melting peak of microcapsules was shown to be 280$^{\circ}C$ The amount of released rosewood from microcapsules at 25$^{\circ}C$ was below 1 % and at 40% was below 3%. Therefore, polyurea microcapsules is capable of preserving rosewood oil for long self-life at normal temperature. Antimicrobial activity to dry cleaning and ironing cycle of wool fabric treated with microcapsules were maintained.