• Title/Summary/Keyword: Selective extraction

Search Result 246, Processing Time 0.052 seconds

The Anti-inflammatory Effect of Angelica gigas Nakai Supercritical Carbon Dioxide Selective Extracts (참당귀 초임계 이산화탄소 선택 추출물의 항염 효능)

  • Park, So Hyeon;Lee, Kwang Won;Park, Shinsung;Shin, Moon Sam;Park, Su In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.6
    • /
    • pp.849-854
    • /
    • 2022
  • In this study, the anti-inflammatory effect of supercritical carbon dioxide selective extracts, which extract decursin and decursinol angelate, the vital active ingredients of Angelica gigas Nakai, in high yield, was measured compared to that of ethanol extracts. To measure the anti-inflammatory effect, the production of nitric oxide(NO), an inflammatory mediator, and interleukin(IL)-6 and IL-8, inflammatory cytokines, was measured. NO production was measured by Griess assay on Raw 264.7 cells induced inflammatory response by lipopolysaccharide(LPS), and IL-6 and IL-8 production was measured by enzyme-linked immunoadsorbent assay(ELISA) on human keratinocyte cell line(HaCaT) cells induced inflammatory response by tumor necrosis factor(TNF)-α. The amount of NO production was suppressed outstandingly by the supercritical carbon dioxide extracts compared to the ethanol extracts. The amount of IL-6 and IL-8 production was increased by the ethanol extracts, whereas statistically significantly inhibited by supercritical carbon dioxide extracts at the concentration of 6.25 ㎍/mL(P<0.01). Through these results, we confirmed that the supercritical carbon dioxide selective extracts of Angelica gigas Nakai could be used as an anti-inflammatory cosmeceutical material to alleviate atopic dermatitis.

Removal of Na+ from Ionic Liquids by Zeolite for High Quality Electrolyte Manufacture

  • Cho, Won-Je;Seo, Yongseong;Jung, Soon Jae;Lee, Won Gil;Kim, Byung Chul;Mathieson, Grant;Yu, Kook-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1693-1697
    • /
    • 2013
  • This study develops a novel method to remove the free cations created during the synthesis of ionic liquid. The cations are removed from the ionic liquid by size-selective adsorption onto chemically surface-modified Zeolite. The porous crystal nano-structure of Zeolite has several electron-rich Al sites to attract cations. While large cations of an ionic liquid cannot access the Zeolite nano-structure, small cations like $Na^+$ have ready access and are adsorbed. This study confirms that: $Na^+$ can be removed from ionic liquid effectively using Zeolite; and, in contrast to the conventional and extensively applied ion exchange resin method or solvent extraction methods, this can be done without changing the nature of the ionic liquid.

Formation of Hydroxyapatite in Portland Cement Paste

  • Chung, Chul-Woo;Lee, Jae-Yong;Kim, Ji-Hyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.1
    • /
    • pp.68-75
    • /
    • 2014
  • In order to increase the integrity of the wellbore which is used to prevent the leakage of supercritical $CO_2$, it is necessary to develop a concrete that is strongly resistant to carbonation. In an environment where the concentration of $CO_2$ is exceptionally high, $Ca^{2+}$ ion concentration in pore solution of Portland cement concrete will drop significantly due to the rapid consumption of calcium hydroxide, which decreases the stability of the calcium silicate hydrate. In this research, calcium phosphates were used to modify Portland cement system in order to produce hydroxyapatite, a hydration product that is strongly resistant to carbonation under such an environment. According to the experimental results, calcium phosphates reacted with Portland cement to form hydroxyapatite. The formation of hydroxyapatite was verified using X-ray diffraction analyses with selective extraction techniques. When using dicalcium phosphate dihydrate and tricalcium phosphate, the 28-day compressive strength was lower than that of plain cement paste. However, the specimen with monocalcium phosphate monohydrate showed equivalent strength to that of plain cement paste.

Optimization of Headspace Sampling Using Solid Phase Microextraction For Volatile Organic Acids in Different Tobacco Types

  • Lee, Jang-Mi;Lee, Jeong-Min;Son, Seong-Ae;Kwon, Young-Ju;Jang, Gi-Chui;Kim, Young-Ho
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.35 no.1
    • /
    • pp.7-12
    • /
    • 2013
  • A Solid-phase micro extraction(SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (sampling temperature, pH, and type of SPME fibers) were optimized to improve sampling efficiency in two aspects ; maximum adsorption and selective adsorption of volatile organic acids onto SPME fibers. Among four types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate), Car/PDMS (Carboxen/Polydimethylsiioxane) and PDMS/DVB(Polydimethylsiioxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency. A variety of tobacco samples such as flue cured, burley and oriental were used in this study. The effect of these parameters was often dominated by the physical and chemical nature (volatility, polarity) of target compounds. This method allowed us to make important improvements in selectivity and sensitivity. The Car/PDMS fiber was shown to be the most efficient at extracting the 10 selected volatile organic acids. The parameters were optimized: $80^{\circ}C$ adsorption temperature, 30 min of adsorption time, $240^{\circ}C$ desorption temperature, 1 min of adsorption time.

Background Segmentation in Color Image Using Self-Organizing Feature Selection (자기 조직화 기법을 활용한 컬러 영상 배경 영역 추출)

  • Shin, Hyun-Kyung
    • The KIPS Transactions:PartB
    • /
    • v.15B no.5
    • /
    • pp.407-412
    • /
    • 2008
  • Color segmentation is one of the most challenging problems in image processing especially in case of handling the images with cluttered background. Great amount of color segmentation methods have been developed and applied to real problems. In this paper, we suggest a new methodology. Our approach is focused on background extraction, as a complimentary operation to standard foreground object segmentation, using self-organizing feature selective property of unsupervised self-learning paradigm based on the competitive algorithm. The results of our studies show that background segmentation can be achievable in efficient manner.

Quantitative Analysis of Ethyl Carbamate in Korean Alcoholic Beverages by Chromatography with Mass Selective Detection (GC/MS 를 이용한 한국 주류 중의 Ethyl Carbamate 정량)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.26-30
    • /
    • 2002
  • In order to determine the contents of ethyl carbamate in Korean traditional alcoholic beverages and general beverages, GC/MS-SIM method was used after extraction of beverages with dichloromethane. The contents of ethyl carbamate in Korean traditional alcoholic beverages, non-distilled alcohol, and whisky were detected in the range of $4.6-50.2{\mu}g/L$, $27.8-45.4{\mu}g/L$, and $24.8-55.1{\mu}g/L$, respectively. The recoveries were ranged from 83.3 to 104.8 %. The values of relative standard deviation were ranged from 1.8 to 14.8 % and the detection limit was $0.3{\mu}g/L$.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • v.4 no.1
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

Simultaneous Determination of Urinary Nicotine and Cotinine Using Gas Chromatography/Nitrogen-Selective Detection (기체 크로마토그래피/질소-선택적 검출을 이용한 소변 중 니코틴과 코티닌의 동시 분석)

  • 김희갑;박미진
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.181-188
    • /
    • 2001
  • A gas chromatographic method was established for the simultaneous determination of urinary nicotine and cotinine. The analytes in basified urine containing a sufficient amount of Na$_2$S0$_4$were extracted into dichloromethane by vigorous shaking. Into the transferred organic phase was added a small amount of acidified methanol (0.5 N HCI in methanol), followed by concentrating the mixture to dryness using a mild stream of nitrogen gas. The concentrate was reconstituted with methanol and the final solution analyzed using the gas chromatograph equipped with the nitrogen-phosphorus detector. The reproducibility tests showed coefficients of variation less than 11% for both compounds. The percent recovery for both analytes ranged from 88 to 103%. The estimated method detection limits for nicotine and cotinine were 0.60 and 5.1 ng/mL, respectively. Extraction efficiencies for both nicotine and cotinine apparently declined without the addition of Na$_2$S0$_4$into the urine. Moreover, the absence of methanolic HCI in the extract resulted in almost complete evaporation of nicotine and partial loss of cotinine during the concentration process, indicating that the formation of nicotine-HCI and cotinine-HCI species is prerequisite to the suppression of the loss of both compounds.

  • PDF

SENSITIVE DETERMINATION OF ELEVEN PHENOLIC ENDOCRINE-DISRUPTING CHEMICALS IN HUMAN URINE USING GAS CHROMATOGRAPHY/MASS SPECTROMETRY -SELECTED ION MONITORING

  • Kim, Hyub;Jang, Cheol-Hyeon
    • Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.93-100
    • /
    • 2007
  • I improved an analytical method for determining trace amounts of eleven phenolic endocrine-disrupting chemicals (11 phenolic EOCs) in human urine. The 11 phenolic EOCs were subjected to hydrolysis and then to solid phase extraction with a XAD-4 column. Alkylphenols, chlorophenols, and bisphenol A in XAD-4 column were eluted with acetonitrile, and the eluate was concentrated under a nitrogen stream, and then tert-butyldimethylsilylation. Separation and determination were done by gas chromatography, using mass spectrometry operating in the selective ion monitoring mode for quantitation. For tert-butyldimethylsily (TBDMS) derivatization the recoveries were $91.2{\sim}125.9%$, the limits of quantitation (LOQ) for the 11 phenolic EOCs in the nanogram-per-milliliter range ($0.025{\sim}1.000\;ng/mL$) were thus achieved by using 1 mL of urine, and the SIM responses were linear with the correlation coefficient varying by $0.9300{\sim}0.9943$. Based on the results for urine samples from unexposed individuals, 4-tert-octylphenol and pentachlorophenol were detected in hydrolysed urine sample. Other alkylphenols, chlorophenols and bisphenol A were not detected.

Graft Copolymerization of Acrylonitrile and 4-Chlorostyrene onto EPDM Rubber. (EPDM 고무에 Acrylonitrile과 4-Chlorostyrene의 그라프트 공중합)

  • Park, Duck-Jei;Ha, Chang-Sik;Lee, Jin-Kook;Cho, Won-Jei
    • Elastomers and Composites
    • /
    • v.24 no.2
    • /
    • pp.110-121
    • /
    • 1989
  • The radical initiated graft copolymerization of acrylonitrile(AN) and 4-chlorostyrene(4-Clst) onto ethylene-propylene-diene terpolymer(EPDM) rubber was investigated under various conditions. Graft copolymer(AU-EPDM-4-Clst) was isolated b: selective solvent extraction and identified by using IR spectroscopy. The percent grafting is determined as a function of solvent, reaction time, and monomer mole ratio. Percent grafting decreased in the order of tetrahydrofuran(THF)>THF/ethyl acetate(EA)(1 : 1)>cyclohexane/EA(1 : 1)>n-hexane/EA(1 : 1). Grafting increased continuously with increasing the reaction time up to 40 hr, beyond which the grafting levelled off. It was observed that percent grafting increased as increasing [4-Clst]/[AN] mole ratio, but decreased when [4-Clst]/[AN] mole ratio was higher than 1.60. The light resistance of graft copolymer(AN-EPDM-4-Clst) was better than that of ABS.

  • PDF