• Title/Summary/Keyword: Selective Detection

Search Result 574, Processing Time 0.027 seconds

Potentimetric Biosensor for Detection of L-Malate and D-Isocitrate Employing ${CO_{3}}^2-$ -Selective Electrode and Enzyme Immobilization in Flow Injection Analysis

  • Kwun, In-Sook;Kim, Meera
    • Preventive Nutrition and Food Science
    • /
    • v.3 no.1
    • /
    • pp.36-42
    • /
    • 1998
  • Ion-selective eleltrodes(ISEs) are simple electrodechemical devices for the direct measurement of ions in the samples. A novel potentiometric biosensor for the determination of L-Malate or D-isocitrate has been developed by using CO2-3 -ISE-FIA system was composed of a pump, an injector, a malic enzyme or isocitric dehydrogenase enzyme reactor, a CO2-3 -ISE, a pH/mV meter, and an integrater. The various factors, such as buffer capacity types of plstericizer and polymer, were optimized for the CO2-3 selectivity. In this novel CO2-3 --ISE-FIA system, the potential difference due to the amount of CO2-3 produced from each enzyme reaction was proportional to the amount of L-malate or D-isocitrate.

  • PDF

Investigation of Isotope Selective Characteristics of the Strontium Magneto-optical Trap by the Fluorescence Detection

  • Ko Kwang-Hoon;Jeong Do-Young;Lim Gwon;Kim Taek-Soo;Cha Yong Ho;Cha Hyung Ki;Lim You-Kyoung
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.87-91
    • /
    • 2005
  • The strontium magneto optical trap followed by a Zeeman slower has been demonstrated. The isotope selective characteristics of the trap have been investigated. The fluorescence spectrum of the MOT was compared with those of other high resolution spectroscopic methods. The red detuned deflection beam is also considered for a more selective spectrum.

Pilymeric Membrane Sodium Ion-Selective Electrodes Based on Calix[4}arene Triesters

  • Kim, Yun Deok;Jeong, Hae Sang;Gang, Seong Ok;Nam, Gye Cheon;Jeon, Seung Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.4
    • /
    • pp.405-408
    • /
    • 2001
  • New lipophilic triesters of calix[4]arene and calix[4]quinone are investigated as sodium ion-selective ionophores in poly(vinyl chloride) membrane electrodes. For an ion selective electrode based on calix[4]arene triester I, the linear response is 1 ${\times}$10-3.5 to 1 ${\times}$ 10-1 M of Na+ concentrations. The selectivity coefficients for sodium ion over alkali metal and ammonium ions are determined. The detection limit (logaNa+ = -4.50) and the selectivity coefficient (logKNa+,K+pot = -1.86) are obtained for polymeric membrane electrode containing calix[4]arene triester I.

Polymeric Membrane Cesium-Selective Electrodes Based on Quadruply-bridged Calix[6]arenes

  • Choe, Eun Mi;O, Hye Jin;Go, Seung Hwa;Choe, Yong Guk;Nam, Gye Chun;Jeon, Seung Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.12
    • /
    • pp.1345-1349
    • /
    • 2001
  • New quadruply-bridged calix[6]arenes (I-V) have been studied as cesium selective ionophores in poly(vinyl chloride) (PVC) membrane electrodes. PVC membranes were prepared with dioctyl sebacate (DOS) or 2-nitrophenyl octyl ether (o-NPOE) as the sol vent mediator and potassium tetrakis(p-chlorophenyl)borate as the lipophilic salt additive. These ionophores produced electrodes with near-Nernstian slope. The selectivity coefficients for cesium ion with respect to alkali, alkaline earth and ammonium ions have been determined. The lowest detection limit (logaCs+ = -6.3) and the higher selectivity coefficient (logkpotCs+,Rb+ = -2.1 by SSM, -2.3 by FIM for calix[6]arene I) for Cs+ have been obtained for membranes containing quadruply-bridged calix[6]arenes (I, Ⅱ, Ⅲ), which have no para t-butyl substituents on the bridging benzene ring.

Lead-selective PVC Membrane Electordes Based on Bis(Crown ether)s

  • 오금철;강은철;정규성;팽기정
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.5
    • /
    • pp.556-558
    • /
    • 1999
  • Lead-selective PVC membrane electrodes based on newly synthesized bis(crown ether)s containing 18-crown-6 moiety was prepared using standard PVC membrane composition. In order to monitor lead in environmental samples by lead sensor, especially good selectivity over alkali and alkaline earth metals has to be obtained. Thus, responses of the PVC membrane prepared with new bis(crown ether)s and Fluka ionophore V (crown ether) base to various cations include lead, alkali and alkaline earth metal ions were investigated for their use as a lead sensor. The polymeric liquid membrane based on trans-1 8-crown-6 ether exhibits the best overall potentiometric performances as a lead-selective electrode in terms of a wide linear dynamic range (between 10-6 and 10-2 M, Pb2+), excellent detection limit (less than 10-6 M) and good durability within limited error. The preferences of lead over other cations, such as Ag+, Hg2+, Na+, Ca2+ and even K+ in the aforementioned electrode are much better than the Fluka ionophore V system.

Development of an improved selective media for differentiation of emetic and diarrheal type Bacillus cereus

  • Hong, Yong-Gun;Lee, Jin-Joo;Kim, Sang-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.815-818
    • /
    • 2021
  • The objective of this study was to develop a differential medium with improved selectivity for the isolation of Bacillus cereus. Mannitol egg yolk polymyxin medium supplemented with D-galactose allowed the differentiation of diarrheal- and emetic-type B. cereus through pH monitoring. The pH of the medium decreased significantly when incubating the emetic-type B. cereus, whereas the pH change was not significant when incubating the diarrheal-type. The addition of pH indicators, such as methyl red and phenol red, to the medium allowed visual differentiation between diarrheal- and emetic-type B. cereus. A solid agar medium was also developed by optimizing the concentrations of medium components such as monosaccharides, agar, egg yolk enrichment, pH indicators, and antibiotics. This study indicates the possibility of applying selective media for the differentiation of diarrheal- and emetic-type B. cereus.

Determination of Nitrate in Chromium Plating Solution with Nitrate-Selective Electrodes

  • 강유라;이원;허황;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.221-226
    • /
    • 1995
  • A method for determining nitrate in post treatment chromium plating solutions with PVC-based nitrate-selective electrodes is described. PVC-based nitrate-selective membranes which contain TDMANO3 ion-exchanger in PVC/NPOE, PVC/DOA or PVC/DBP matrices, and a commercially available Corning electrode (No. 476134) have been compared in respect of their detection limits, response slopes, selectivities at various pHs, and dynamic response to the hydrochromate ion in basic condition. The PVC/DBP/TDMANO3 membrane electrode was chosen as the ISE detector for the determination of nitrate in the presence of hydrochromate interference. The amount of nitrate in real post treatment chromium plating solution could be determined successfully with this electrode in both static and flow-injection measurements when the sample was properly diluted with an alkaline buffer.

Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry

  • Younah Kim;Hyoje Jo;Yelim Lee;Soo Yeon Kang;Sangkyu Lee
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.141-146
    • /
    • 2023
  • Liraglutide is a medication prescribed for the management of type 2 diabetes and chronic obesity. A simple, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of liraglutide in rat plasma. After a simple protein precipitation step, liraglutide was chromatographically separated using the ACQUITY Premier Peptide BEH C18 Column with mobile phases comprising 50% acetonitrile and 50% methanol, and water with 0.3% FA. Positive ion electrospray ionization in multiple reaction monitoring mode was used to achieve detection. Good linearity was observed in the 5-600 ng/mL concentration range (R2 > 0.99). Liraglutide had intra- and inter-day precision values of 2.13%-9.86% and 4.14%-8.36%, respectively. The accuracy ranged from -2.36% to 2.58%. The recovery and matrix effect were within acceptable limits. This selective LC-MS/MS method was used to study the pharmacokinetic properties of liraglutide after subcutaneous administration in rats.

Selective Detection of Campylobacter sp. and Campylobacter jejuni in Meat Food by Polymerase Chain Reaction (PCR을 이용한 육류 내 Campylobacter sp. 및 Campylobacter jejuni의 분리 검출)

  • Joo, Jong-Won;Hong, Kyung-Pyo;Kim, Yong-Hui;Cho, Sang-Buem
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.5
    • /
    • pp.753-759
    • /
    • 2008
  • The principal objective of this study was to develop the optimum oligonucleotide primers for the simple detection of Campylobacter in food samples. In order to achieve this goal, a variety of oligonucleotide primers were designed via the modification of 16S rDNA, ceuE and mapA sequences of Campylobacter. Through the subsequent analysis of the specificity and sensitivity of primers, two types of oligonucleotide primers, CB4 and CJ1, were selected for Campylobacter genus-specific and C. jejuni species-specific primers, respectively. The detection limit was found to be $10^0{\sim}10^1$ cells per reaction with the prepared cell suspension, however, the sensitivity in the meat samples was less, at $10^1{\sim}10^2$. We suggested that PCR inhibitors such as hemoglobin or immunoglobulin in pork or beef influenced.

  • PDF

The Study of Hierarchical Intrusion Detection Based on Rules for MANET (MANET에서 규칙을 기반으로 한 계층형 침입 탐지에 관한 연구)

  • Jung, Hye Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.4
    • /
    • pp.153-160
    • /
    • 2010
  • MANET composed mobile nodes without central concentration control like base station communicate through multi-hop route among nodes. Accordingly, it is hard to maintain stability of network because topology of network change at any time owing to movement of mobile nodes. MANET has security problems because of node mobility and needs intrusion detection system that can detect attack of malicious nodes. Therefore, system is protected from malicious attack of intruder in this environment and it has to correspond to attack immediately. In this paper, we propose intrusion detection system based on rules in order to more accurate intrusion detection. Cluster head perform role of monitor node to raise monitor efficiency of packet. In order to evaluate performance of proposed method, we used jamming attack, selective forwarding attack, repetition attack.