• Title/Summary/Keyword: Selective Detection

Search Result 576, Processing Time 0.03 seconds

Determination of Hg22+ Ions Using a Modified Glassy Carbon Electrode with 2,2':6':2''-Terpyridine

  • Kong, Young-Tae;Bae, Yun-Jung;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.346-350
    • /
    • 2002
  • A glassy carbon electrode (GCE) modified with 2,2':6':2”-terpyridine (2,2':6':2”-TPR) using a spin coating method was applied for the highly selective and sensitive analysis of a trace amount of $Hg_2^{2+}$ ions. Various experimental parameters, which influenced the response of the 2,2':6':2”-TPR modified electrode to $Hg_2^{2+}$ ions, were optimized. The linear sweep and differential pulse voltammograms for the 2,2':6':2”-TPR modified electrode deposited with Hg show a well-defined anodic peak at +0.65 V (vs. Ag|AgCl). After a 25 min preconcentration time in an $Hg_2^{2+}$ ion solution (0.1 M acetate buffer, pH 5.0), differential pulse voltammetry(DPV) with 2,2':6':2”-TPR modified electrode shows a linear response between $1.0\;{\times}\;10^{-6}M\;and\;2.0\;{\times}\;10^{-7}M$. The least-square treatment of these data produce an equation of I[${\mu}A$] = 0.031 + 0.005C with r = 0.980(n = 5). The detection limit of this electrode with linear sweep voltammetry and differential pulse anodic voltammetry were $2.0\;{\times}\;10^{-6}M\;and\;8.0\;{\times}\;10^{-8}M$, respectively. The presence of Pb, Fe, Cd, Ti, Ni, Co, Mg, Al, Mn, and Zn did not interfere in the analysis of the $Hg_2^{2+}$ ion. The 2,2':6':2”-TPR modified GCE has been successfully applied in determination trace amounts of Hg in a human urine sample.

Recovery and Survival of Listeria monocytogenes in Surface and Sea Water (지표수 및 해수로부터 Listeria monocytogenes의 분리 및 생존성)

  • Yang, Ju;Kim, Toh-Gyong;Kang, Ho-Jo
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.3
    • /
    • pp.327-333
    • /
    • 2002
  • The study was carried out to examine the distribution and survival rate of Listeria monocytogenes (L monocytogenes) from various source of waters using improved isolation method. In comparision of enrichment media for isolation of L monocytogenes from water, the isolation rate and 50% detection limit of the pathogen were higher in UVM modified Listeria enrichment broth (UVM) than Listeria enrichment broth (LEB). On the other hand, when compared the selective media for isolation of the pathogen from water, the isolation rate was highest in culture at Oxford agar followed by Fraser agar, and LEB agar. In order to improve enrichment method, 100 ml of water samples with 0.1 CFU/ml of L monocytogenes was inoculated into 10 ml of UVM concentrated at 10-fold, and incubated for 24 h at $36^{\circ}C$. Isolated frequency of the pathogens in improved enrichment method completely corresponded with common (filter) method. Of a total mumber of 147 water samples from river, lake and sea, the pathogen was isolated from 1 of 39 (2.6%) river water samples and 1 of 75 (1.3%) sea water samples, but no pathogen was isolated from 33 lake water samples. Serotypes of 2 isolates were identified as type 1. L monocytogenes decreased in number from 7.2-7.4 to 4.2-4.7 log CFU/ml for 1 week poststorage (5 and $20^{\circ}C$), but the pathogens were able to be detected in river and sea water until 8 weeks after storage. However, in tap water, L monocytogenes were decreased to undetectable level after 2 weeks of storage.

Determination of Verapamil with ISE based on Ion Exchanger (이온교환체 전극을 이용한 베라파밀 정량)

  • Lee, Eun-Yup;Kim, Dong-O;Chang, Seung-Hyun;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.40 no.2
    • /
    • pp.135-140
    • /
    • 1996
  • Ion-selective poly(vinyl chloride)(PVC) membrane electrodes for the determination of the calcium antagonist verapamil and its pharmaceutical preparations were described. Verapam il-superchrome garnet Y(SGY), lumogallion(LG), acid red 97(AR97), Dragendorff(DD) and Meyer reagent ion pairs were inverstigated as an electroactive compound for membrane electrode. Stable potentiometric response was obtained with azo dye at pH 6.5-4.0 and with DD, and Meyer reagent at pH 6.5-3.0. The best plasticizer was 49w/w% 2-nitrophenyl octyl ether for azo dye, and 65.3w/w% tri(n-butyl) citrate for DD and Meyer reagent. Potentiometric response slopes of optimized membrane electrodes based on SGY, LG, AR97, DD, and Meyer complex for verapamil were 52.49, 54.88, 50.81, 54.13 and 49.31 mV/dec., respectively. Lower limits of linear range were $1.0{\times}10^6M$ for SGY, LG, and AR97, while those for DD and Meyer reagent were $4{\times}10^{-6}M$. Detection limits for all these electrodes were $1{\times}10^{-5}M,\;4{\times}10^{-6}M,\;1.8{\times}10^{-6}M,\;8{\times}10^{-7}M,\;and\;1{\times}10^{-6}M$ with relative standard deviation of 2.56, 3.6, 3.96, 2.56, 3.20%, respectively.

  • PDF

Evaluation of measurement uncertainty for quantitative determination of chlorite and chlorate in fresh-cut vegetables using ion chromatography

  • Jung, Sungjin;Kim, Dasom;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Jung, Young Rim;Kim, Hekap
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.6
    • /
    • pp.591-598
    • /
    • 2017
  • This study aimed to evaluate the measurement uncertainty for the quantitative determination of chlorite and chlorate in ready-to-eat fresh-cut vegetables using ion chromatography with a hydroxide-selective column. One gram of the homogenized sample in deionized water was sonicated and centrifuged at 8,500 rpm. The supernatant was purified by passing it through a Sep-Pak tC18 cartridge, followed by chromatographic determination using a Dionex IonPac AS27 column. The linearity of the calibration curves, recovery, repeatability, and reproducibility of the method were satisfactory. The method detection limit was estimated to be approximately 0.5 mg/kg. Each uncertainty component was evaluated separately, and the combined and expanded uncertainty values were calculated at the 95% confidence level. The measured concentrations for 3 mg/kg of chlorite and chlorate standard materials were $3.18{\pm}0.32$ and $3.10{\pm}0.42mg/kg$, respectively. These results confirmed the reliability of the developed method for measuring the two chlorine-based oxyanions in fresh-cut vegetables.

Nasal Administration of Granisetron to Rats (흰쥐를 이용한 Granisetron함유 경비 투여제제의 평가 및 그 적용)

  • Woo, Jong-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.6
    • /
    • pp.363-369
    • /
    • 2006
  • Granisetron is a selective 5-HT3 receptor antagonist that is used therapeutically for the prevention of vomiting and nausea associated with emetogenic cancer chemotherapy. Although this drug is commercially available for intravenous and oral dosage, there is a need for intranasal delivery formulations in specific patient populations in which the use of these dosage forms may be unfeasible and/or inconvenient. A rapid and specific high-performance liquid chromatography method with mass spectrometric detection(LC-MS) was developed and validated for the analysis of granisetron in plasma after nasal administration in rats. This method has been validated for concentrations ranging from 5 to 1000 ng/ml with simple treatment. This technique has high level reproducibility, accuracy, and sensitivity. The method described was found to be suitable for the analysis of all samples collected during preclinical pharmacokinetic investigations of granisetron in rats after nasal administration. This study was aimed to investigate the feasibility of nasal delivery of granisetron for the elimination of vomiting. The effects of osmolarity, dosage volume at the same dose and applied dose on the nasal absorption of granisetron in rats were observed. No significant difference in the effect of osmolarity and dosage volume at the same dose was observed. As the applied dose of granisetron in nasal formulation increased, the absorption increased linearly. Based on these results it appears that only the applied dose(drug mass) determines the nasal absorption of granisetron. The bioavailability of granisetron on nasal administration of 4 mg/kg appeared to be comparable to that of intravenous administration of the same dose. These results suggest that granisetron can be efficiently delivered nasally and the development of nasal formulation will be feasible.

Study on Characterization of Galvanic Oxygen Sensor (갈바니식 산소센서의 특성에 관한 연구)

  • Cho, Dong-Hoe;Park, Myon-Yong;Lee, Byoung-Cho;Chung, Koo-Chun;Park, Jongman;Lee, Kyeong-Jae;Chung, Sung-Sook;Park, Sun-Young;Lee, Kwang-Woo
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.371-378
    • /
    • 1994
  • The detection range of this galvanic oxygen sensor for oxygen concentration was 0.0% to 20.0%. By using gold or silver as cathode, reproducible response time and sensitivity to change of oxygen concentration were observed. The anode was Pb-Sn-Ca alloy. Oxygen selective permeable membrane was hydrophobic and porous Teflon film. The effect of the membranes varying in thickness have been studied on the temperature($10{\sim}50^{\circ}C$) and relative humidity(R. H 0~99%). Lead acetate buffer solution as the electrolyte has shown a high output voltage and longer life.

  • PDF

Simultaneous determination of fluorometholone and tetrahydrozoline hydrochloride in ophthalmic suspension by HPLC

  • Pham, Thuy-Vy;Mai, Xuan-Lan;Song, Ha-Ram;Ahn, Soo-Bin;Cha, Min-Jeong;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.88-95
    • /
    • 2018
  • A simple, sensitive, and selective high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous quantification of fluorometholone (FLU) and tetrahydrozoline hydrochloride (THZ) in combined ophthalmic formulations. The effects of several factors, including detection wavelength, buffer pH, buffer concentration, and organic solvent concentration, on the performance of the method were investigated. The performance of the developed method was validated in accordance with the requirements of the International Conference on Harmonization. The linearity of the calibration curves in the desired concentration range was high for both FLU and THZ ($r^2=0.9999$). The accuracy and precision of the method were determined by a recovery study at analyte concentrations of 80 %, 100 %, and 120 %. The recovery was 99.60-100.17 % for both analytes, with a relative standard deviation less than 1.0 % at any concentration level. The validated results indicate that the new HPLC method could be successfully applied for the simultaneous determination of FLU and THZ in ophthalmic suspensions.

An Efficient symbol Synchronization Scheme with an Interpolator for Receiving in OFDM (OFDM 전송방식의 수신기를 위한 보간기의 효율적인 심볼 동기방법의 성능분석)

  • 김동옥;윤종호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.4
    • /
    • pp.567-573
    • /
    • 2002
  • In this paper, we propose a new symbol time synchronization scheme suitable for the OFDM system with an interpolator. The proposed scheme performs the following three steps. In the first step, the coarse symbol time synchronization is achieved by continuously measuring the average power of the received envelope signal. Based on this average power, the detection possibility for the symbol time synchronization is determined. It the signal is sufficient for synchronization, we next perform a relatively accurate symbol time synchronization by measuring the correlation between a short training signal and the received envelope signal. Finally, an additional frequency synchronization is performed with a long training signal to correct symbol synchronization errors caused by the phase rotation. From the simulation results, one can see that the proposed synchronization scheme provides a good synchronization performance over frequency selective channels.

Preparation of ZnO nanorods by hydrothermal method and their $NO_2$ sensing characteristics (수열합성법을 이용한 ZnO 나노로드의 제조 및 이산화질소 감응 특성)

  • Cho, Pyeong-Seok;Kim, Ki-Won;Lee, Jong-Heun
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.506-511
    • /
    • 2006
  • ZnO nanorods were prepared by the hydrothermal reaction of a solution containing $Zn(NO_3)_2{\cdot}6H_2O$, NaOH, cyclohexylamine, ethanol and water, and their $NO_2$ and CO sensing behaviors were investigated. By the control of water concentration in solution, the morphology and agglomeration of ZnO nanorods could be manipulated, which is associated with the variation of $[OH^-]$ resulted from an interaction between water and cyclohexylamine. Sea-urchin-like and well-dispersed ZnO nanorods were prepared at low and high water content, respectively. Well-dispersed ZnO nanorods showed 1.8 fold change in resistance at 1 ppm $NO_2$ while there was no significant change in resistance at 50 ppm CO. This selective detection of $NO_2$ in the presence of CO can be used in automated car ventilation systems.

Changes in oncogenic protein levels in peri-implant oral malignancy: a case report

  • Seo, Mi Hyun;Myoung, Hoon;Lee, Jong Ho;Kim, Soung Min;Lee, Suk Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.46.1-46.9
    • /
    • 2019
  • Background: Oral squamous cell carcinoma (OSCC) constitutes a group of tumors that exhibit heterogeneous biology, histopathology, and clinical behaviors. Case presentation: A 73-year-old male had a whitish leukoplakia-like lesion around inflamed peri-implant area (#42, #43, and #44), and this lesion had transformed to OSCC within 3 years. He underwent mass resection, selective neck dissection, and reconstructive surgery. To detect any carcinogenesis progression, we examined the removed tumor tissue as well as the patient's preoperative and postoperative sera to identify causative oncogenic proteins using immunoprecipitation high-performance liquid chromatography (IP-HPLC). Conclusions: The protein expression levels of p53, E-cadherin, β-catenin, MMP-10, HER2, NRAS, Met, HER2, and ERb were significantly lower in the serum collected on postoperative day 10 than in the preoperative serum, and if these proteins are consistently not elevated in the serum 3 months after surgery compared with the preoperative serum, these proteins can be potential oncogenic proteins. However, we also found that the serum extracted 3 months after the operation had elevated levels of oncogenic proteins compared with that of the preoperative and 10-day postoperative serum indicating the possibility of tumor recurrence. At postoperative follow-up period, ipsilateral neck metastasis and second primary lesion were found and additional surgery was performed to the patient. IP-HPLC using the patient's serum shows the possibility of oncogenic protein detection. However, follow-up IP-HPLC data is needed to find out patient-specific prognostic factors.