• 제목/요약/키워드: Selective Detection

검색결과 576건 처리시간 0.032초

Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry

  • Attar, Tarik;Harek, Yahia;Larabi, Lahcen
    • 대한화학회지
    • /
    • 제57권5호
    • /
    • pp.568-573
    • /
    • 2013
  • A selective and sensitive method for simultaneous determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The procedure involves an adsorptive accumulation of Cu(II)-ETSC (4- ethyl-3-thiosemicarbazide) on a hanging mercury drop electrode, followed by a stripping voltammetry measurement of reduction current of adsorbed complex at about -715 mV. The optimum conditions for the analysis of copper (II) ion are : pH 10.3, concentration of 4-ethyl-3-thiosemicarbazide $3.25{\times}10^{-6}$ M and an accumulation potential of -100 mV. The peak current is proportional to the concentration of copper over the range 0.003-125 ng/mL with a detection limit of 0.001 ng/mL and an accumulation time of 60 s. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods of adsorptive stripping voltammetry for the determination of copper. The developed method was validated by analysis of whole blood certified reference materials.

Methylumbelliferyl 형광기질을 이용한 평판배지상의 미생물 체외 세포효소측정방법 (Microbial Extracellular Enzyme Detection on Agar Plates by Means of Fluorogenic Methylumbelliferyl-Substrates)

  • 김상진
    • 미생물학회지
    • /
    • 제28권3호
    • /
    • pp.229-235
    • /
    • 1990
  • 평판배지상 세균 colony의 체외 세포 효소활성을 직접 측정할 수 있는 신속하고 정확한 방법에 대하여 기술하였다. 일반적으로 세균의 효소 특성을 살피기 위해서는 단백질, 전분, chitin, tween-80 등과 같은 고분자 물질을 첨가한 선택배지를 사용하고 있으나 그 방법상 여러 가지 문제점이 있다 그러므로 본 연구에서는 형광물질의 일종인 Methvlumbell liferyl(MUF) 기질이 일반적으보 사용되고 있는 천연 고분자 물질고 유사한가를 순수분리세균 균주를 이용하여 실험으로 검증하였다. MUF 기질 분해원리에 기초를 둔 기술한 새로운 방법은 순수 분리 균주는 물론 colony 계수에 사용되는 평판배지상에서도 세균의 체외세포 효소 특성을 정량적으로 측정 가능하게 한다. 본 새로운 방법을 이용하여 담수 생태계와 해양 퇴적토내 종속영양세균의 체외 효소 활성을 측정하여 고찰하였다.

  • PDF

분자 비컨을 이용한 살아 있는 세포에서 단일클론항체 경쇄와 중쇄 mRNA 검출에 의한 세포주 선별방법 (Live Cell Detection of Monoclonal Antibody Light and Heavy Chain mRNAs using Molecular Beacons)

  • 정승아;이원종
    • KSBB Journal
    • /
    • 제31권1호
    • /
    • pp.33-39
    • /
    • 2016
  • Developing the method for the selection of animal cell line producing therapeutic monoclonal antibody (mAb) is invaluable as its market is rapidly growing. Although the quality of produced mAb is as important as quantity, however there is no method developed for the selective screening of cell lines on the basis of both quantity and quality. From recent reports, the ratio of light and heavy chain mRNAs of mAb in the cell is a key parameter for the indication of product quality. Therefore, it is obvious that developing the novel method that can detect both light and heavy chain mRNAs in single live cell will provide unprecedented opportunities in bio-industry. Here, we have constructed oligonucleotide probes, molecular beacons for the detection of light or heavy chain mRNAs, respectively, in the live cells producing mAbs. Both beacons showed increased fluorescent intensity after transient transfection of plasmid expressing mAbs analyzed by fluorometer. Flow cytometric analysis clearly demonstrated that both molecular beacons can simultaneously detect the expression of light and heavy chain mRNAs of mAb in the same cell. The technique described in the thesis provides the new direction and concept for developing the method for the smart selection of cell lines producing recombinant proteins including therapeutic mAbs.

Detection of QTLs Influencing Panicle Length, Panicle Grain Number and Panicle Grain Sterility in Rice(Oryza sativa L.)

  • Ahamadi, Jafar;Fotokian, M.H.;Fabriki-Orang, S.
    • Journal of Crop Science and Biotechnology
    • /
    • 제11권3호
    • /
    • pp.163-170
    • /
    • 2008
  • The detection, characterization and use of quantitative traits loci, QTL, have significant potential to improve the efficiency of selective breeding of species. Therefore, a population with 59 advanced backcross lines($BC_2F_5$), derived from a cross between IR64 and Tarome molaei, were studied in Tonekabon Rice Research Station of Iran in order to map QTLs for panicle length, number of grain per panicle, and panicle grain sterility in rice. The parental screening wtih 235 SSR markers in agarose and polyacrylamide gels revealed 114 markers with clear polymorphic bands. To search for QTLs associated with panicle length, number of grain per panicle, and panicle grain sterility, we constructed a genetic linkage map using 114 microsatellite markers. Positive and negative transgressive segregations were observed in $BC_2F_5$ lines for all traits. Using multiple interval mapping(MIM), a total of 20 putative QTLs were detected, of which eight were for panicle length, three for number of grains, and nine for panicle grain sterility. The maximum number of QTLs were mapped on chromosomes 1 and 2 with eight QTLs. These QTL markers could possible be utilized for marker-assisted selection.

  • PDF

나노 양자점 결합을 이용한 살모넬라 식중독균 검출 (Detection of Pathogenic Salmonella with a Composite Quantum Dot)

  • 김기영;양길모;김용훈;모창연;박샛별
    • Journal of Biosystems Engineering
    • /
    • 제35권6호
    • /
    • pp.458-463
    • /
    • 2010
  • It is required to develop rapid methods to identify pathogenic Salmonella in food products for protecting and maintaining safety of the public health from Salmonellosis. The objective of the present study was to explore feasibility of the nanotechnology to detect pathogenic Salmonella rapidly in various samples. Sensitivity of the a composite quantum dot to detect Salmonella typhimurium in samples were evaluated. For selective detection of Salmonella, anti-Salmonella polycolonal antibody was utilized to capture and stain Salmonella. Quantum dots were attached onto Salmonella in the samples and produced fluorescent light. Fluorescence response of the composite quantum dot was measured with a commercial fluorescence meter. The fluorescence signal starts to increase with the samples in which higher concentration of the cells were contained. The sensitivity of the sensor was $10^6\;CFU/mL$ Salmonella spiked in PBS.

STI-CMP 공정 적용을 위한 연마 정지점 고찰 (A Study of End Point Detection Measurement for STI-CMP Applications)

  • 이경태;김상용;김창일;서용진;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.90-93
    • /
    • 2000
  • In this study, the rise throughput and the stability in fabrication of device can be obtained by applying of CMP process to STI structure in 0.18um semiconductor device. To employ in STI CMP, the reverse moat process has been added thus the process became complex and the defects were seriously increased. Removal rates of each thin films in STI CMP was not equal hence the devices must to be effected, that is, the damage was occured in the device dimension in the case of excessive CMP process and the nitride film was remained on the device dimension in the case of insufficient CMP process than these defects affect the device characteristics. To resolve these problems, the development of slurry for CMP with high removal rate and high selectivity between each thin films was studied then it can be prevent the reasons of many defects by reasons of many defects by simplification of process that directly apply CMP process to STI structure without the reverse moat pattern process.

  • PDF

페이딩 채널에서 직렬 결합 CPM (SCCPM)에 대한 RS-A-SISO 알고리즘과 확률 밀도 진화 분석 (Density Evolution Analysis of RS-A-SISO Algorithms for Serially Concatenated CPM over Fading Channels)

  • 정규혁;허준
    • 대한전자공학회논문지TC
    • /
    • 제42권7호
    • /
    • pp.27-34
    • /
    • 2005
  • Iterative detection은 additive white Gaussian noise(AWGN) channel의 경우 interleaver들을 포함한 조합유한상태머신(concatenated Finite State Machine)들에 대해 근사적으로 optimal solution에 가깝다는 것이 입증되었습니다. 수신단에서 정확한 채널 상태 정보(perfect channel state information)가 얻어질 수 없는 경우 adaptive Iterative detection이 시간적으로 변하거나 또는 부정확한 채널 변수를 다루기위해 필요합니다. Iterative detection과 adaptive iterative detection대한 기본 building block은 각각 Soft-Input Soft-Output (SISO)와adaptive SISO (A-SISO)입니다. SISO와 A-SISO의 complexity은 state memory나 channel memory에 비례해서 지수적으로 증가합니다. 본 논문에서는 Reduced State SISO (RS-SISO) 알고리즘이 A-SISO의 complexity 감소를 위해 적용되어 fading ISI channel을 통한 serially concatenated CPM의 성능이 adaptive iterative detection을 이용하면 터보 코드 같은 성능을 나타내는 것과 또한 RS-A-SISO system이 큰 iterative detection gain을 가지는 것을 보였습니다. RS-A-SISO 알고리즘에 대한 다양한 design option들의 성능을 평가하였으며 성능과 complexity를 비교하였습니다. 또한 보통 AWGN 채널에서 사용되어지는 density evolution 분석기법이 주파수 선택적인 페이딩 채널에서 RS-A-SISO 시스템에서도 좋은 분석기법임을 보였습니다

Non-O157 장출혈성대장균 검출을 위한 증균배지 및 선택배지 성능 평가 (Evaluation of enrichment broth and selective media for the detection of non-O157 enterohemorrhagic Escherichia coli)

  • 이다연;김희언;서동원;조용선
    • 한국식품과학회지
    • /
    • 제48권4호
    • /
    • pp.323-328
    • /
    • 2016
  • 본 연구는 non-O157 EHEC의 혈청형별 증균 및 선택배지에서의 분리 조건 및 비교 시험을 하여 최적의 검출 방법을 제시하고자 하였다. EC medium with MUG broth, BRILA broth, mTSB broth with novobiocin 3종의 증균배지 성능 및 배양 조건의 비교 결과 EC-MUG 증균배지를 $42^{\circ}C$에서 24시간 배양하면 EHEC의 효율적인 증균이 이루어질 수 있을 것이라 생각된다. ENDO agar, Chromocult agar, TBX agar, CHROMagar$^{TM}$ STEC medium 4종의 선택배지에 가장 효과적인 배지를 확인결과 TBX agar가 검출율이 가장 높았으나 1종의 배지를 사용했을 경우 다양한 EHEC 혈청형 균를 검출 하기는 어렵다고 생각된다. 그러므로 EHEC를 효과적으로 검출하고자 할 경우 TBX agar와 보완이 가능한 그 외의 배지를 사용하여야 효과적인 검출이 가능할 것으로 생각된다. 또한, 각 배지가 혈청형에 따른 분리효율이 다르므로 본 연구 결과를 참조하여 가장 적합한 배지를 선택 해야 할 것으로 보인다. 향후 non-O157 EHEC의 적절한 기질을 사용하여 다양한 혈청형을 모두 검출 할 수 있는 효율적인 배지의 개발이 필요하다고 생각된다.

단일 조성 실온 경화형 실리콘러버를 지지체로 사용한 고체상 탄산이온선택성 전극의 개발 (One-component Room Temperature Vulcanizing-Type Silicone Rubber-Based Solid-State Carbonate Ion Selective Electrode)

  • 김미경;윤인준;조성호;신혜라;한종호;하정한;남학현;차근식
    • 대한화학회지
    • /
    • 제48권3호
    • /
    • pp.266-272
    • /
    • 2004
  • 소형 고체상 전극에 단일 조성 실온 경화형(one-component room temperature vulcanizing type) 실리콘러버 730(730 RTV)을 지지체로 도입하여 가소제가 필요 없는 탄산이온선택성 전극막을 개발하였다. 본 연구에서 최적화된 탄산이온선택성 전극막의 조성은 85.75 wt%의 730 RTV, 11.08 wt%의 trifluoroacetyl-p-decylbenzene(TFADB), 3.17 wt%의 tridodecyl-methylammonium chloride(TDMACl)로 제조 되었고, 우수한 전기화학적 특성(감응기울기 (26.3 mV/dec.), 선택성($logKT^{pot}_{CO_{2},Cl^-}$= -4.00, $logKT^{pot}_{TCO_{2},Sal^-}$=1.69), 검출한계(4.0${\times}10^{-4}M$))을 보였으며, 이와 같은 조성의 막을 도입한 평면형 고체상 센서는 60일 이상 초기특성을 유지하였다.

수송체로서 아민페놀을 이용한 은(I)이온-선택 전극의 제조와 실제 샘플에서 은의 선택적 측정 (Construction of a Silver(I) Ion-Selective Electrode Using Amine Phenol Ligand as Carrier and the Selective Determination of Silver in Actual Samples)

  • Xu, Wen-Ju;Chai, Ya-Qin;Yuan, Ruo
    • 대한화학회지
    • /
    • 제55권1호
    • /
    • pp.63-69
    • /
    • 2011
  • 이 작업은 수송체로서 N,N'-bis(2-hydroxybenzyl)-1,3-diaminopropane (L1)과 N,N'-bis(2-hydroxybenzyl)-2,2-dimethyl-1,3-diaminopropane (L2)에 기초한 $Ag^+$ 이온-선택 전극의 제조, 개발 그리고 전압반응에 대해 토의한다. $Ag^+$에 대하여 L1에 기초한 전극은 58.7 mV/dec에 도달하는 안정한 Nernst에 가까운 기울기와 $1.0{\times}10^{-6}M$의 검출한계를 갖는 등급의 최소 다섯가지 순서의 선형범위에서 최적의 전압 반응 특징을 보이는 것을 나타낸다. 제안된 전극은 다른 테스트한 양이온과 비교하여 $Ag^+$에 우위의 선택성을 보였다. 훌륭한 전압 분석적 특징은 중요한 진짜 샘플에서 은의 순도분석의 성공적인 응용을 이끌 것이다. 그리고 그것은 제안된 $Ag^+$-ISE가 측정 능력의 중요한 진보를 보여준다는 것을 나타내고 있다. 그러나 L2에 기초한 전극에 대해서는, 약한 전압 반응 특징들이 전체 실험 과정에서 관측되었다.