• 제목/요약/키워드: Selective Detection

검색결과 574건 처리시간 0.024초

Retina-Motivated CMOS Vision Chip Based on Column Parallel Architecture and Switch-Selective Resistive Network

  • Kong, Jae-Sung;Hyun, Hyo-Young;Seo, Sang-Ho;Shin, Jang-Kyoo
    • ETRI Journal
    • /
    • 제30권6호
    • /
    • pp.783-789
    • /
    • 2008
  • A bio-inspired vision chip for edge detection was fabricated using 0.35 ${\mu}m$ double-poly four-metal complementary metal-oxide-semiconductor technology. It mimics the edge detection mechanism of a biological retina. This type of vision chip offer several advantages including compact size, high speed, and dense system integration. Low resolution and relatively high power consumption are common limitations of these chips because of their complex circuit structure. We have tried to overcome these problems by rearranging and simplifying their circuits. A vision chip of $160{\times}120$ pixels has been fabricated in $5{\times}5\;mm^2$ silicon die. It shows less than 10 mW of power consumption.

  • PDF

Fuzzy Based Shadow Removal and Integrated Boundary Detection for Video Surveillance

  • Niranjil, Kumar A.;Sureshkumar, C.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2126-2133
    • /
    • 2014
  • We present a scalable object tracking framework, which is capable of removing shadows and tracking the people. The framework consists of background subtraction, fuzzy based shadow removal and boundary tracking algorithm. This work proposes a general-purpose method that combines statistical assumptions with the object-level knowledge of moving objects, apparent objects, and shadows acquired in the processing of the previous frames. Pixels belonging to moving objects and shadows are processed differently in order to supply an object-based selective update. Experimental results demonstrate that the proposed method is able to track the object boundaries under significant shadows with noise and background clutter.

초음파 서모그라피를 이용한 용접 결함 검사 (A Welding Defect Inspection using an Ultrasound Excited Thermography)

  • 조재완;정진만;최영수;정승호;정현규
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2006년도 춘계 학술대회 개요집
    • /
    • pp.148-150
    • /
    • 2006
  • In this paper, the applicability of an UET(ultrasound excited thermography) for a defect detection of the welded receptacle is described. An UET(ultrasound excited thermography) is a defect-selective and fast imaging tool for damage detection. A high power ultrasound-excited vibration energy with pulse durations of 280ms is injected into the outer surface of the welded receptacle made of Al material. An ultrasound vibration energy sent into the welded receptacle propagate inside the sample until they are converted into the heat in the vicinity of the defect. The injection of the ultrasound excited vibration energy results in heat generation so that the defect is turned into a local thermal wave transmitter. Its local heat emission is monitored by the thermal infrared camera. And they are processed by the image recording system. Measurement was performed on aluminum receptacle welded by using Nd:YAG laser. The observed thermal image revealed two area of defects along the welded seam.

  • PDF

Nanowell Array based Sensor and Its Packaging

  • Lee, JuKyung;Akira, Tsuda;Jeong, Myung Yung;Lee, Hea Yeon
    • 마이크로전자및패키징학회지
    • /
    • 제21권3호
    • /
    • pp.19-24
    • /
    • 2014
  • This article reviews the recent progress in nanowell array biosensors that use the label-free detection protocol, and are detected in their natural forms. These nanowell array biosensors are fabricated by nanofabrication technologies that should be useful for developing highly sensitive and selective also reproducible biosensors. Moreover, electrochemical method was selected as analysis method that has high sensitivity compared with other analysis. Finally, highly sensitive nanobiosensor was achieved by combining nanofabrication technologies and classical electrochemical method. Many examples are mentioned about the sensing performance of nanowell array biosensors will be evaluated in terms of sensitivity and detection limit compared with other micro-sized electrode without nanowell array.

붕소가 도핑된 다이아몬드 전극을 이용한 생체화학물질의 검출 (Detection of Bio-chemical by Boron-doped Diamond Electrode)

  • 김규식;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.569-572
    • /
    • 2001
  • Selective. highly stable determination of epinephrine(adrenalin) was achieved in cyclic voltammetric measurement carried out at electrochemically treated conductive boron-doped diamond electrode. Boron-doped diamond electrodes were prepared on single crystal Si wafers by microwave plasma chemical vapor deposition and $B_{2}O_{3}$ was dissolved in acetone/methanol(9:1) mixture solution so that the B/C weight ratio ca. $10^{4}ppm$. Epinephrine is a kind of catecholamines, which secreted from adrenal marrow cells. The serious problem to detection of epinephrine is the interference phenomena of electroactive constituent. including AA. In this study. electrochemical treatment of BDD was carried out to discriminate between epinephrine and AA responses. Experimental results showed that the peak potential of AA oxidation shift to the positive direction and the oxidation peak of epinephrine was unchanged. The effect of electrochemical treatment was maintained up to 40hrs.

  • PDF

Direct Determination of Total Arsenic and Arsenic Species by Ion Chromatography Coupled with Inductively Coupled Plasma Mass Spectrometry

  • Nam, Sang-Ho;Kim, Jae-Jin;Han, Soung-Sim
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권12호
    • /
    • pp.1805-1808
    • /
    • 2003
  • The simultaneous determination of As(III), As(V), and DMA has been performed by ion chromatography (IC) coupled with inductively coupled plasma-mass spectrometry (ICP-MS). The separation of the three arsenic species was achieved by an anionic separator column (AS 7) with an isocratic elution system. The separated species were directly detected by ICP-MS as an element-selective detection method. The IC-ICP-MS technique was applied for the determination of arsenic species in a NIST SRM 1643d water sample. An As(III) only was detected in the sample. The detection limits of As(III), As(V) and DMA were 0.31, 0.45, and 2.09 ng/mL, respectively. It was also applied for the determination of arsenic species in a human urine obtained by a volunteer, and three arsenic species were identified. The determination of total As in human urines that were obtained from 25 volunteers at the different age was also carried out by ICP-MS.

혈장중 Ofloxacin의 HPLG분석 (High Performance Liquid Chromatographic Assay of Ofloxacin in Plasma)

  • 백채선;김영수
    • 한국임상약학회지
    • /
    • 제10권1호
    • /
    • pp.38-41
    • /
    • 2000
  • A high-performance liquid chromatographic method with fluorometric detection was evaluated for analysis of ofloxacin in plasma. Biological fluids (plasma, $200\;{\mu}L$) were prepared for assay by protein precipitation with chlorofurm. The detection of ofloxacin and triamterene as an internal standard were performed at 358 nm for excitation and 495 nm for emission. The HPLC separation was carried out on Ultrasphere ODS column (4.6 mm${\times}25\;cm,\;5\;{\mu} m$) with acetonitrile $(45\%)$-phosphoric acid $(1.5\%)\;containing\;0.3\%$ sodium laurylsulfate as the mobile phase. The flow-rate was 1.0 mL/min. The calibration graphs were linear from 3.0 to 80 ng/mL with r=0.998. The minimal detectable concentration in plasma was 1.5 ng/mL. The proposed technique is reproducible, selective, reliable and sensitive.

  • PDF

부정합된 최대 상관값을 이용한 초기 동기 임계치 결정 기법 (Threshold detection technique for code acquisition using maximum mismatched correlation value)

  • 유영환;김종헌;강성철;강창언
    • 한국통신학회논문지
    • /
    • 제21권7호
    • /
    • pp.1803-1813
    • /
    • 1996
  • This paper describes an automatic threshold decision using a maximum mismatched correlation value in the direct sequence spread spectrum (DS-SS) system. For received PN codes with different single-to-noise ratio (SNR), this scheme is able to detect a desired threshold value in the search mode, i.e. a maximum mismstched correlation value, so that value is utilized as a threshold for the verification mode. Performance of the proposed scheme in both the additive white gaussian noise (AWGN) and frequency-selective Rayleigh fading channels is analyzed through the Monte Carlo simulation. And hardware implementation of this scheme using a DSP processor is demonstrated. The proposed acquisition shceme is compared to the conventional constant threshold (CT) scheme, and significant improvement of performance is shown. Analysis of system performance in the verification mode is presented, and key quantities such as the false alarm probability and the detection probability are derived in a AWGN channel.

  • PDF

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.

붕소가 도핑된 다이아몬드 전극을 이용한 생계화학물질의 검출 (Detection of Bio-chemical by Boron-doped Diamond Electrode)

  • 김규식;;;박수길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2001
  • Selective, highly stable determination of epinephrine(adrenalin) was achieved in cyclic voltammetric measurement carried out at electrochemically treated conductive boron-doped diamond electrode. Boron-doped diamond electrodes were prepared on single crystal Si wafers by microwave plasma chemical vapor deposition and B$_2$O$_3$ was dissolved in acetone/methanol(1:1) mixture solution so that the B/C weight ratio ca. 10$^3$ppm.. Epinephrine is a kind of catecholamines, which secreted from adrenal marrow cells. The serious problem to detection of epinephrine is the interference phenomena of electroactive constituent, including AA. In this study, electrochemical treatment of BDD was carried out to discriminate between epinephrine and AA responses. Experimental results showed that the peak potential of AA oxidation shift to the positive direction and the oxidation peak of epinephrine was unchanged. The effect of electrochemical treatment was maintained up to 40hrs.

  • PDF