• 제목/요약/키워드: Selective Detection

검색결과 574건 처리시간 0.025초

Application of Principal Components Analysis Method to Wireless Sensor Network Based Structural Monitoring Systems

  • Congyi, Zhang;Mission, Jose Leo;Kim, Sung-Ho;Youk, Yui-Su;Kim, Hyeong-Joo
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제8권1호
    • /
    • pp.11-17
    • /
    • 2008
  • Typical wireless sensor networks used in structural monitoring are continuous types wherein data transmission is progressive at all time that may include irrelevant and insignificant data and information. Continuous types of wireless monitoring systems often pose problems of handling large-sized data that may deteriorate the performance of the system. The proposed method is to suggest an event-triggered monitoring system that captures and transmits relevant data only. An error signal generated by the Principal Components Analysis (PCA) is utilized as an index for event detection and selective data transmission. With this new monitoring scheme, the remote server is relieved of unwanted data by receiving only relevant information from the wireless sensor networks. The performance of the proposed scheme was verified with simulation studies.

A Multi-Channel Gas Sensor Using Fabry-Perot Interferometer-Based Infrared Spectrometer

  • Choi, Ju Chan;Lee, June Kyoo;Kong, Seong Ho
    • 센서학회지
    • /
    • 제21권6호
    • /
    • pp.402-407
    • /
    • 2012
  • We report a Fabry-Perot interferometer (FPI)-based multi-channel micro-spectrometer used for multi-gas measurement in the spectral range of $3-5{\mu}m$ and its gas sensing performance. The fabricated infrared (IR) spectrometer consists of two parts: an FPI on the top side for selective IR filtering and a $V_2O_5$-based IR detector array on the bottom side for the detection of the filtered IR. Experimental results show that the FPI-based multi-channel gas sensor has reliability and selectivity for simultaneously detecting environmentally harmful gases such as $CH_4$, $CO_2$, $N_2O$ and CO in the spectral range of $3-5{\mu}m$. The fabricated FPI-based multi-channel gas sensor also demonstrated that a reliable and selective detection of gas concentrations ranging from 0 to 500 ppm is feasible. In addition, the electrical characteristics demonstrate a superior response performance in regards to the selectivity in the multi-target gases.

Selective Trace Analysis of Mercury (II) Ions in Aqueous Media Using SERS-Based Aptamer Sensor

  • Lee, Chank-Il;Choo, Jae-Bum
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.2003-2007
    • /
    • 2011
  • We report a highly sensitive surface-enhanced Raman scattering (SERS) platform for the selective trace analysis of mercury (II) ions in drinkable water using aptamer-conjugated silver nanoparticles. Here, an aptamer designed to specifically bind to $Hg^{2+}$ ions in aqueous solution was labelled with a TAMRA moiety at the 5' end and used as a Raman reporter. Polyamine spermine tetrahydrochloride (spermine) was used to promote surface adsorption of the aptamer probes onto the silver nanoparticles. When $Hg^{2+}$ ions are added to the system, binding of $Hg^{2+}$ with T-T pairs results in a conformational rearrangement of the aptamer to form a hairpin structure. As a result of the reduced of electrostatic repulsion between silver nanoparticles, aggregation of silver nanoparticles occurs, and the SERS signal is significantly increased upon the addition of $Hg^{2+}$ ions. Under optimized assay conditions, the concentration limit of detection was estimated to be 5 nM, and this satisfies a limit of detection below the EPA defined limit of 10 nM in drinkable water.

Development of a Competitive Direct Enzyme-Linked Immunosorbent Assay for Teicoplanin

  • Lee, Hyang-Burm;Kwak, Bo-Yeon;Lee, Jae-Chan;Kim, Chang-Jin;Shon, Dong-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권3호
    • /
    • pp.612-619
    • /
    • 2004
  • A competitive direct enzyme-linked immunosorbent assay (cdELISA) was developed for selective and rapid detection of a glycopeptide antibiotic, teicoplanin (TP). TP was conjugated to bovine serum albumin (BSA) for use as an immunogen. Repeated subcutaneous injections of 0.5 mg of the conjugate was effective in generating specific polyclonal antibody (PAb) toward TP in rabbits, as determined by cdELISA. TP-horseradish peroxidase conjugate (TP-HRP) was used as an enzyme marker. The cdELISA was developed based on a competition reaction between TP-BSA PAb and TP-HRP conjugate. The TP-BSA PAb was highly sensitive (detection limit, 0.3 ng/ml and specific toward teicoplanin, showing no cross-reactivity to other glycopeptide antibiotics including vancomycin. There were good correlations ($r^2$=0.84 and 0.76, respectively) between cdELISA and microbiological assay, and high-performance liquid chromatography. The cdELISA system developed in this work is expected to be useful not only for selective and rapid monitoring of TP but also for study of TP pharmacokinetics.

HPLC-MSD 를 이용한 식육 중 합성항균제의 동시분석 (Simultaneous detection for synthetic antimicrobials in muscle by high performance liquid chromatography-mass selective detector (HPLC-MSD))

  • 홍인석;최윤화;권택부;이정학
    • 한국동물위생학회지
    • /
    • 제29권3호
    • /
    • pp.317-330
    • /
    • 2006
  • This study was conducted to develop the analytical method about simultaneous determination for synthetic antimicrobials in muscle by high performance liquid chromatography - mass selective detector (HPLC- MSD). Solid phase extraction (SPE), matrix solid phase dispersion (MSPD) and liquid-liquid extraction (LLE) have been adapted as pretreatment procedures for HPLC- MSD. Among various solvent tested, methanol was chosen for extraction of synthetic antimicrobials in muscles. For the optimized response, the values of various MS parameters including fragment voltage, drying gas flow, nebulizer pressure, drying gas temperature were verified. The average recovery rates using MSPD and SPE for muscles of bovine and pork were 78.9-127.1% and 78.3-121.7%, respectively. This method was verified the satisfactory performance for fourteen synthetic antimicrobials excepting carbadox in muscle of pork as detection limit of $0.05{\mu}g/g$ on API/ES SIM mode.

폐수중 티오시안산이온을 측정하기 위한 계면활성제를 이용한 고분자 막전극 (The Polymer Membrane Electrode by Surfactants for Measuring Continuously Thiocyanate Ion in Wastewater)

  • 최종석;안형환;강안수;우인성;황명환
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.13-20
    • /
    • 1991
  • Ion-selective electrode responsive to the thiocynate ion prepared by using the quaternary ammonium salts as a active material and PVC as a membrane matrix. The effect of chemical structure and composition of active material, and the membrane thickness on the linear response. the detection limit, and Nernstian slope of the electrode studied. Under the above optimum conditions of membrane, the effect of pH and the selectivity coefficients to various interfering anions were compared and investigated. It was concluded that the functions of thiocynate ion-selective electrode(ISE) were closely related to the chemical structure of the quaternary ammonium salts. The linear response, and the detection limit of the electrode potential increased with the increase of the carbon chain length of the alkyl group in the quaternary ammonium salts in the ascending order of Aliquat 336T, TOAT, TDAT, and TDDAT. The optimum membrane thickness was 0.3mm. The electrode characteristics was better with the decrease of the concentration of active material, and the best concentration was 3 weight percent. The membrane potential was independent of the pH variation in the region from pH 2 to 12. The order of the selectivity coefficients is as follows:Cl $O_4$$^{[-10]}$$I^{[-10]}$ >N $O_3$$^{[-10]}$ >B $r^{[-10]}$$F^{[-10]}$ >C $l^{[-10]}$ >O $A_{c}$ $^{[-10]}$ 〓S $O_4$$^{2-}$.

  • PDF

Highly Simplified and Bandwidth-Efficient Human Body Communications Based on IEEE 802.15.6 WBAN Standard

  • Kang, Tae-Wook;Hwang, Jung-Hwan;Kim, Sung-Eun;Oh, Kwang-Il;Park, Hyung-Il;Lim, In-Gi;Kang, Sung-Weon
    • ETRI Journal
    • /
    • 제38권6호
    • /
    • pp.1074-1084
    • /
    • 2016
  • This paper presents a transmission method for improving human body communications in terms of spectral efficiency, and the performances of bit-error-rate (BER) and frame synchronization, with a highly simplified structure. Compared to the conventional frequency selective digital transmission supporting IEEE standard 802.15.6 for wireless body area networks, the proposed scheme improves the spectral efficiency from 0.25 bps/Hz to 1 bps/Hz based on the 3-dB bandwidth of the transmit spectral mask, and the signal-to-noise-ratio (SNR) by 0.51 dB at a BER of $10^{-6}$ with an 87.5% reduction in the detection complexity of the length of the Hamming distance computation. The proposed preamble structure using its customized detection algorithm achieves perfect frame synchronization at the SNR of a BER of $10^{-6}$ by applying the proposed pre-processing to compensate for the distortions on the preamble signals due to the band-limit effects by transmit and receive filters.

A Study on a Compact Coupler between an Optical Fiber and a Grating-assisted Graphene-embedded Silicon Waveguide for a Wavelength-selective Photodetector

  • Heo, Hyungjun;Kim, Sangin
    • Current Optics and Photonics
    • /
    • 제1권5호
    • /
    • pp.514-524
    • /
    • 2017
  • We proposed an integrated wavelength-selective photodetector based on a grating-assisted contradirectional coupler and a graphene absorption layer for a coarse wavelength division multiplexing (CWDM) communication system. The center wavelength of the absorption spectrum of the proposed device can be tuned simply by changing the period of the grating, and the proposed device structure is suitable to forming a cascaded structure. Therefore, an array of the proposed device of different grating periods can be used for simultaneous wavelength demultiplexing and signal detection in a CWDM communication system. Our theoretical study showed that the designed device with a grating length of $500{\mu}m$ could have an absorption of 95.1%, an insertion loss of 0.2 dB, and a 3 dB bandwidth of 7.5 nm, resulting in a -14 dB crosstalk to adjacent CWDM channels. We believe that the proposed device array can provide a compact and economic solution to receiver implementation in the CWDM system by combining functions of wavelength demultiplexing and signal detection.

A Quinoline carboxamide based Fluorescent Probe's Efficient Recognition of Aluminium Ion and its Application for Real Time Monitoring

  • Manivannan, Ramalingam;Ryu, Jiwon;Son, Young-A
    • 한국염색가공학회지
    • /
    • 제32권4호
    • /
    • pp.185-192
    • /
    • 2020
  • A novel binding site for metal ion made by designing molecule with tetrazolo quinoline with hydrazine carboxamide (TQC) and the designed molecule successfully synthesized. The probe works by selectively detecting Al3+ ion via both fluorimetric and colorimetric approach. The probe's effectiveness towards aluminium ion detection is highly sensitive and selective with no substantial interference with other competing ions. The added Al3+ ion to TQC fetched a rapid change of visual color to yellow from colorless, also the response of fluorescence turn-on. The fluorescence turn-on and color change visibly by the probe TQC with Al3+ ion credited to the ICT phenomenon (intramolecular charge-transfer transition). The likely interaction of the probe with aluminium ion has also been there predicted from ESI-MS spectral analysis results. The usefulness of the probe confirmed by practical utility by making a test kit to monitor Al3+ ion in water which showed a naked eye detection by notable color change.

Selective acetate detection using functional carbon nanotube fiber

  • Choi Seung-Ho;Lee, Joon-Seok;Choi, Won-Jun;Lee, Sungju;Jeong, Hyeon Su;Choi, Seon-Jin
    • 센서학회지
    • /
    • 제30권6호
    • /
    • pp.357-363
    • /
    • 2021
  • We developed a chemiresistive anion sensor using highly conductive carbon nanotube fibers (CNTFs) functionalized with anion receptors. Mechanically robust CNTFs were prepared via wet-spinning utilizing the nematic liquid crystal properties of CNTs in chlorosulfonic acid (CSA). For anion detection, polymeric receptors composed of dual-hydrogen bond donors, including thiourea 1, squaramide 2, and croconamide 3, were prepared and bonded non-covalently on the surface of the CNTFs. The binding affinities of the anion receptors were studied using UV-vis titrations. The results revealed that squaramide 2 exhibited the highest binding affinity toward AcO-, followed by thiourea 1 and croconamide 3. This trend was consistent with the chemiresistive sensing responses toward AcO- using functional CNTFs. Selective anion sensing properties were observed that CNTFs functionalized with squaramide 2 exhibited a response of 1.08% toward 33.33 mM AcO-, while negligible responses (<0.1%) were observed for other anions such as Cl-, Br-, and NO3-. The improved response was attributed to the internal charge transfer of dual-hydrogen bond donors owing to the deprotonation of the receptor upon the addition of AcO-.