Isotope-Dilution Mass Spectrometry for Quantification of Urinary Active Androgens Separated by Gas Chromatography

  • Lee, Su-Hyeon;Choi, Man-Ho;Lee, Won-Yong;Chung, Bong-Chul
    • Mass Spectrometry Letters
    • /
    • 제1권1호
    • /
    • pp.29-32
    • /
    • 2010
  • Cross reacting antibodies can cause an overestimation of the results of immunoassays. Therefore, alternative methods are needed for the accurate quantification of steroids. Gas chromatography combined with isotope-dilution mass spectrometry (GC-IDMS) is developed to quantify urinary active androgens, testosterone, epitestosterone and dihydrotestosterone, which are clinically relevant androgens to both hair-loss and prostate diseases. The method devised involves enzymatic hydrolysis with $\beta$-glucuronidase, solid-phase extraction, liquid-liquid extraction using methyl tert-butyl ether and subsequent conversion to pentafluorophenyldimethylsilyl-trimethylsilyl (flophemesyl-TMS) derivatives for sensitive and selective analysis in selected-ion monitoring mode. Flophemesyl-TMS derivatization not only eliminates matrix interference but also has a good peak resolution within a 6 min-run. A selective and sensitive GC technique with flophemesyl-TMS derivatives also allows accurate quantitative analysis of three active androgens when combined with IDMS. The limit of quantification of the three analytes was <50 pg/mL, and extraction recoveries ranged from 91.9 to 102.1%. The precision and accuracy were 1.2~6.5% and 89.0~106.7%, respectively. This GC-IDMS method can be useful for evaluating the drug efficacy and monitoring the biological processes responsible for male-pattern baldness and prostate diseases.

Accurate Determination of Malachite Green and Leucomalachite Green in Fish using Isotope Dilution Liquid Chromatography/Mass Spectrometry (ID-LC/MS)

  • Ahn, Seong-Hee;Kim, Byung-Joo;Lee, Yun-Jung;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3228-3232
    • /
    • 2010
  • Malachite green (MG) has been used world-widely in aquaculture as a parasiticide or fungicide. Although MG performed successfully, it has not been permitted for use in aquaculture from European Union, USA, and Canada because of its carcinogenicity and mutagenicity. We developed a sensitive and specific method to determine MG and its principal metabolite, leucomalachite green (LMG), respectively by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS). To enhance the extraction recovery of MG and LMG from fish tissue, an additional step, saponification, was introduced in sample preparation process to remove fat in sample extract, which hampered the performance of SPE columns. The residue of MG and LMG in fish was analyzed using liquid chromatography mass spectrometry in the selected ion monitoring (SIM) mode by monitoring at m/z 329 and 334 for MG and $d_5$-MG and at m/z 331 and 337 for LMG and $^{13}C_6$-LMG, respectively. This method was validated by comparing with the value of the reference material provided by Laboratory Government Chemistry (LGC). The results agreed within the measurement uncertainty and the accuracy was much improved than the provided reference value by LGC.

Selective 3,4-Dihydroxyphenylalanine Analysis in Human Urine as Ethoxycarbonyltert-butyldimethylsilyl Derivatives by Gas Chromatography-Mass Spectrometry

  • Paik, Man-Jeong;Nguyen, Duc-Toan;Yoon, Jae-Hwan;Cho, In-Seon;Shim, Woo-Young;Kim, Kyoung-Rae;Cho, Ki-Hong;Choi, Sang-Dun;Lee, Gwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.977-980
    • /
    • 2011
  • A new analytical method for measurement of 3,4-dihydroxyphenylalanine (DOPA) in human urine was developed. DOPA from an aqueous solution was converted into an ethoxycarbonyl (EOC) derivative. A tertbutyldimethylsilyl (TBDMS) reaction under anhydrous conditions was then attempted for analysis by gas chromatography-mass spectrometry in selected ion monitoring mode. A new mass spectral data on DOPA as a tri-EOC/mono-TBDMS derivative was built. This method showed good linearity (r ${\geq}$ 0.999), precision (% relative standard deviation = 3.1-9.2), and accuracy (% relative error = -7.2-8.8), with a detection limit of 0.05 ng/mL. This selective and accurate method of DOPA analysis will be useful for biochemical monitoring of various neurological disorders including Parkinson's disease in biological fluids.

Development of an Isotope-Dilution Flow-Injection Electrospray/ Mass Spectrometric Method for the Accurate Determination of Glucosamine in Pharmaceutical Formulation

  • Kim, Gui-Nam;Kim, Byung-Joo;Ahn, Seong-Hee;Hwang, Eui-Jin;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권2호
    • /
    • pp.363-367
    • /
    • 2009
  • An isotope-dilution flow-injection electrospray/mass spectrometric method was developed for the accurate determination of glucosamine contents in pharmaceutical formulations. Samples were extracted by methanol. After spiking glucosamine-1-$^{13}C_1$ as an internal standard, the extracts were then analyzed by flow-injection ESI/MS in a selected ion monitoring (SIM) mode to detect [M+H]$^+$ ions of the analyte and its isotope analogue at m/z 180 and m/z 181, respectively. Confirmatory measurements were made by selectively monitoring the collisionally induced dissociation channels of m/z 180 $\rightarrow$ m/z 72 and m/z 181 $\rightarrow$73, respectively, to test the possibility of bias in the SIM method due to matrix interferences, but any significant bias in the SIM mode was not observed. Repeatability and reproducibility studies showed that the flow-injection ESI/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0 %. Other results for the method validation are reported.

Determination of Acaricides in Honey by Solid-Phase Extraction and Gas Chromatography / Mass Spectrometry

  • Hong, Joo-Yeon;Jung, Ok-Sang;Ryoo, Jae-Jeong;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.61-66
    • /
    • 2009
  • An analytical method based on solid-phase extraction and gas chromatography / mass spectrometry has been developed for measurement of acaricides (amitraz, bromopropylate, coumaphos, cymiazole, and tetradifon) in honey sample. In the stability test of acaricides in honey, amitraz underwent a rapid degradation into 2,4-dimethylaniline (DMA), 2,4-dimethylphenylformamide (DMPF), and N-(2,4-dimethylphenyl)-N'-methylformamidine (DMPMF), whileas other acaricides were found to be stable even for over three months. Extraction of five acaricides from 5g of honey sample was carried out by liquid-liquid extraction using 20mL of ethylacetate. For purification, Florisil-SPE cartridge with elution of 5mL of n-hexane/ acetone (55:45, v/v) was found to remove interferences effectively. Quantification was performed using gas chromatography / mass spectrometry in the selected ion monitoring mode. Spiking experiments were carried out to determine the recovery, precision, and limits of detection (LODs) of the method. The overall recovery values from honey spiked at 0.02 and 0.20 ${\mu}g/g$ levels, respectively, were found to be greater than 75% for all acaricides. The method detection limits for acaricides were ranged from 0.1 to 3 ppb. The developed method in this study was applied for the monitoring of acaricides in honey products collected from urban markets in Korea.

Liquid Chromatographic Determination of Etofenprox Residues in Foods with Mass-Spectrometric Confirmation

  • Lee, Young-Deuk;Kwon, Chan-Hyeok;Kwon, Ki-Sung
    • 한국환경농학회지
    • /
    • 제30권4호
    • /
    • pp.432-439
    • /
    • 2011
  • BACKGROUND: An official analytical method was developed to determine etofenprox residues in agricultural commodities using high-performance liquid chromatography (HPLC). METHODS AND RESULTS: The etofenprox residue was extracted with acetone from representative samples of five raw products which comprised rice grain, apple, mandarin, cabbage, and soybean. The extract was then serially purified by liquid-liquid partition and Florisil column chromatography. For rice and soybean samples, acetonitrile/n-hexane partition was additionally coupled to remove nonpolar lipids. Reversed phase HPLC using an octadecylsilyl column was successfully applied to separate etofenprox from co-extractives. Intact etofenprox was sensitively detected by ultraviolet absorption at 225 nm. Recovery experiment at the quantitation limit validated that the proposed method could apparently determine the etofenprox residue at 0.02 mg/kg. Mean recoveries from five crop samples fortified at three levels in triplicate were in the range of 93.6~106.4%. Relative standard deviations of the analytical method were all less than 10%, irrespective of crop types. A selected-ion monitoring LC/mass spectrometry with positive atmospheric-pressure chemical ionization was also provided to confirm the suspected residue. CONCLUSION(s): The proposed method is simple, rapid and sensitive enough to be employed in routine inspection or monitoring of agricultural products for the etofenprox residue.

시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법 (Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review)

  • 김찬식;류홍덕;정유진;김용석;류덕희
    • 한국물환경학회지
    • /
    • 제32권6호
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

GC/MS에 의한 뇨 중 내인성 에스트로겐의 Profiling (Urinary Profiling of Endogeneous Estrogens Using GC/MS)

  • 이선화;양윤정;김태욱;팽기정;정봉철
    • 대한화학회지
    • /
    • 제41권4호
    • /
    • pp.186-197
    • /
    • 1997
  • 성 호르몬으로서의 역할과 암 성장의 잠재적 저해 효과를 지니고 있는 에스트로겐의 대사체들을 동시에 분석하기 위하여 Serdolit AD-2 수지와 효소 가수분해, 액체-액체 추출방법을 이용한 전처리 과정을 확립하였으며, MSTFA/TMSCl 혼합액에 의해 trimethylsilylether 형태로 유도체화된 에스트로겐들을 GC/MS의 SIM(selected ion monitorning) 방법으로 동시에 분석, 정량할 수 있는 조건을 설정하였다. 그 결과 회수율은 80.97~97.81%이었고, within-a-day 및 day-to-day 분석에서의 RSD값은 각각 0.24~25.35%, 1.05~23.94%이었으며, 이 방법으로는 소변 내에 존재하는 19종의 에스트로겐 대사체들을 정량하여 한국인 정상인 참고치(여자:22~35세, 남자: 39~57세)를 설정하였다.

  • PDF

GC/MS-SIM for the Determination of Alkylphenols, Chlorophenols and Bisphenol A in Paper Materials

  • Kim, Hyub
    • 한국환경독성학회:학술대회논문집
    • /
    • 한국환경독성학회 2003년도 춘계학술대회
    • /
    • pp.145-145
    • /
    • 2003
  • A method for the determination of alkylphenols, chlorophenols and bisphenol A in paper materials using GC/MS-SIM has been developed. Eleven endocrine disrupting chemicals (EDCs) of phenols in paper samples were extracted with acetonitrile. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 82.4∼108.8 % by area ratio of pheranthrene-d$\sub$10/ vs bisphenol A d$\sub$l6/. (isoBOC derivatization and TBDMS derivatization) The SIM responses were linear with the correlation coefficient varying 0.9717∼0.9995 (isoBOC derivatization), and 0.9842∼0.9980 (TBDMS derivatization). The range of concentrations was respectively, 0.95∼l.44 ng/g in 2,4-dichlorophenol, 1.01∼1.17 ng/g in t-butylphenol, 2.17∼5.84 ng/g in pentachlorophenol, 12.68∼14.88 ng/g in nonylphenol and 30.84∼153.72 ng/g in bisphenol A.

  • PDF

기체크로마토그래피/질량분석기에 의한 수질시료 중 4-니트로톨루엔의 분석법 연구 (Analysis of 4-Nitrotoluene in Water by Gas Chromatography/Mass Spectrometry)

  • 이희경;권오승;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • 제15권1_2호
    • /
    • pp.45-51
    • /
    • 2000
  • Analytical method of 4-nitrotoluene (4-NT) in water was developed by 9as chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). 4-NT was extracted with diethyl ether. Organic layer was washed with 5 % sodium chloride solution. The influence of solvent and evaporation condition on extraction of 4-NT were examined. The retention time of 4-NT peak was 7.72 min. Coefficient of variation (CV) of 4-NT (ng) within day and day-to-day was ranged from 7.0 to 14.6% and from 7.7 to 20.8%, respectively. Recovery of 4-NT was ranged from 84 to 109%, and detection limit of 4-H was lese than 1 ng/㎖.

  • PDF