• Title/Summary/Keyword: Selected ion monitoring

Search Result 161, Processing Time 0.024 seconds

Combined Isobutoxycarbonylation and tert-Butyldimethylsilylation for the GC/MS-SIM Detection of Alkylphenols, Chlorophenols and Bisphenol A in Mackerel Samples

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Archives of Pharmacal Research
    • /
    • v.26 no.9
    • /
    • pp.697-705
    • /
    • 2003
  • The alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) followed by two work-up methods for comparison: isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. Eleven endocrine disrupting chemicals (EDCs) of phenols in biological samples were extracted with acetonitrile and then the acetonitrile layer underwent freezing filtration 6$0^{\circ}C$ for 2 hours. Solid-phase extraction (SPE) was used with XAD-4 and subsequent conversion to isoBOC or TBDMS derivatives for sensitivity analysis with the GC/MS-SIM mode. For isoBOC derivatization and TBDMS derivatization the recoveries were 92.3∼150.6% and 93.8∼108.3%, the method detection limits (MDLs) of bisphenol A for SIM were 0.062 $\mu$ g/kg and 0.010 $\mu$ g/kg, and the SIM responses were linear with the correlation coefficient varying by 0.9755∼0.9981 and 0.9908∼0.9996, respectively. When these methods were applied to mackerel samples, the concentrations of the 11 phenol EDCs were below the MDL.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

GC-MS Analysis of Organophosphorus Pesticide Residue in Seawater From the Kwangyang Bay, Korea (광양만 해수 중 유기인 잔류 농약성분의 GC-MS 분석)

  • Park, Mi-Ok;Park, Jeom-Sook
    • Journal of Environmental Science International
    • /
    • v.15 no.4
    • /
    • pp.293-304
    • /
    • 2006
  • Sea water samples collected in August, 1994 from 20 stations in the Kwangyang Bay were analyzed by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) to investigate persistence and distribution pattern of four organophosphorus pesticides (DDVP, Diazinon, IBP, EDDP). Except for IBP, the contamination by DDVP, Diazinon, and EDDP in marine aquatic environment in Korea has not been reported previously. In this study, however, all these four pesticides were detected in all stations (except DDVP) and their concentrations were in ng/L level. The concentrations ranged from detection limit to 15.3ng/L for DDVP, 1.8-27.7ng/L for Diazinon, 7.3-63.5ng/L for IBP, and 22.2-1100.1ng/L for EDDP. It is noteworthy that the measured concentrations of IBP and EDDP in this study would be much lower than usual, since the use of IBP and EDDP was less than 50% of average annual consumption due to unusually dry and hot weather condition in the summer of 1994. It was very surprising to find that the highest concentrations of organophosphorus pesticides were observed at stations near Daesa Streamlet instead of Seomjin River, which has more point source of the pesticides. This result suggests that the small river discharge during heavy ram period in summer can give harmful effect on marine biota (both wild and aqua-cultured) with its organophosphorus pesticide residue, despite of their short residence time in aquatic environment. In order to protect the marine life properly from acute toxicity of the organophosphorus pesticides, it needs to be emphasized that monitoring the level of agricultural pesticides in river run-off should be done during active consumption period rather at regular intervals.

Patterns of Plasma Fatty Acids in Rat Models with Adenovirus Infection

  • Paik, Man-Jeong;Park, Ki-Ho;Park, Joong-Jean;Kim, Kyoung-Rae;Ahn, Young-Hwan;Shin, Gyu-Tae;Lee, Gwang
    • BMB Reports
    • /
    • v.40 no.1
    • /
    • pp.119-124
    • /
    • 2007
  • Adenoviral vectors are among the most promising vectors available for human gene therapy. However, the use of recombinant adenoviral vectors, including replicationcompetent adenovirus (RCA), raises a variety of safety concerns in relation to the development of new therapies based on gene therapy. To examine how organic compounds change in rat plasma following the injection of adenovirus, $\beta$-galactosidase expressing recombinant adenovirus (designated rAdLacZ) or RCA, we investigated the content of fatty acids (FAs), which are important biochemical indicators in pathological conditions. Pattern recognition analysis on the level of FAs in rat plasma is described for the visual discrimination of adenovirus infection groups from normal controls. Plasma FAs from four control rats (normal group), and from four rats with rAdLacZ infection and six rats with RCA infection (the two abnormal groups), were examined by gas chromatography-mass spectrometry in selected ion monitoring modes as their tert-butyldimethylsilyl derivatives. In total, 20 FAs were positively detected and quantified. The results of the Student's t-test on the normal mean of two abnormal groups, the levels of three FAs (p<0.05) from rAdLacZ group and eleven FAs (p<0.05) from RCA group were significantly different. When star symbol plotting was applied to the group mean values of 20 FAs after normalization to the corresponding normal mean values, the resulting eicosagonal star patterns of the two infected groups were distorted into similar shapes, but were distinguishable from each other. Thus, these approaches will be useful for screening and monitoring of diagnostic markers for the effects of infection following the use of adenoviral vectors in gene therapy.

Change of Groundwater-Streamflow Interaction according to Groundwater ion in a Green House Land (비닐하우스 지역의 지하수 양수에 따른 지하수-하천수 상호 유동 변화 분석)

  • Kim, Nam Won;Lee, Jeong Woo;Chung, Il Moon;Kim, Chang Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.10
    • /
    • pp.1051-1067
    • /
    • 2012
  • Increased use of water curtain facilities to keep green house warm during winter cultivation has been known to cause excessive groundwater ion which might lead to decline of groundwater level, resulting in streamflow depletion. Therefore it is required to quantitatively assess the effects of groundwater ion on the streamflow depletion such as magnitude and extent. The objective of this study is to assess the change of stream-aquifer interaction according to groundwater ion near stream. To this end, a green house cultivation land in Sooha-ri, Sindun-myun, Icheon-si, Gyonggi-do was selected as a field experimental site, and monitoring wells were established near and within stream to observe the water level and temperature changes over a long period of time. From the observed water level and temperature data, it was found that the river reach of interest changed to a losing stream pattern during the winter cultivation season due to groundwater level decline around pumping wells near the stream. The continuous exchange rates between stream and aquifer were estimated by plugging the observed water level data series into the experimental relation between head difference and exchange rate, showing the streamflow depletion by 16% of the groundwater pumping rate in Feb, 2011.

Development of Gas Chromatography/Mass Spectrometry for the Determination of Essential Fatty Acids in Food Supplemental Oil Products

  • Ahn, Seonghee;Yim, Yoon-Hyung;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.75-78
    • /
    • 2013
  • A gas chromatography/mass spectrometric (GC/MS) method was developed as a candidate reference method for the accurate determination of essential fatty acids (linoleic acid, ${\alpha}$- and ${\gamma}$-linolenic acids) in food supplemental oil products. Samples were spiked with three internal standards (stearic acid-$d_{35}$, $^{13}C_{18}$-linoleic acid, and $^{13}C_{18}$-${\alpha}$-linolenic acid). Samples were then subject to saponification, derivatization for methylation, and extraction by organic solvent. For GC/MS measurement, an Agilent HP-88 column, designed for the separation of fatty acid methyl esters, was selected after comparing with other columns as it provided better separation for target analytes. Target analytes and internal standards were detected by selected ion monitoring of molecular ions of their methyl ester forms. The GC/MS method was applied for the measurement of three botanical oils in NIST SRM 3274 (borage oil, evening primrose oil, and flax oil), and measurement results agreed with the certified values. Measurement results for target analytes which have corresponding isotope-labeled analogues as internal standard were calculated based on isotope dilution mass spectrometry (IDMS) approach, and compared with results calculated by using the other two internal standards. Results from the IDMS approach and the typical internal standard approach were in good agreement within their measurement uncertainties. It proves that the developed GC/MS method can provide similar metrological quality with IDMS methods for the measurement of fatty acids in natural oil samples if a proper fatty acid is used as an internal standard.

Geochemical characteristics of a LILW repository I. Groundwater (중.저준위 방사성 폐기물 처분부지의 지구화학 특성 I. 지하수)

  • Choi, Byoung-Young;Kim, Geon-Young;Koh, Yong-Kwon;Shin, Seon-Ho;Yoo, Si-Won;Kim, Doo-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.297-306
    • /
    • 2008
  • This study was carried out to identify the characteristics of hydrochemistry controlling groundwater chemical condition in a repository site of Gyeongju. For this study, 12 bore holes of all monitoring bore holes in the study area were selected and total 46 groundwater samples were collected with depth. In addition, 3 surfacewater samples and 1 seawater sample were collected. For water samples, cations and anions were analyzed. The environmental isotopes(${\delta}^{18}O-{\delta}D$, Tritium, ${\delta}^{13}C,\;{\cdot}{\delta}^{34}S$) were also analyzed to trace the origin of water and solutes. The result of ${\delta}^{18}O\;and\;{\delta}D$ analysis showed that surface water and groundwater were originated from precipitation. Tritium concentrations of groundwater decreased with depth but high concentrations of tritium indicated that groundwater was recharged recently. The results of ion and correlation analysis showed that groundwater types of the study area were represented by Ca-Na-$HCO_3$ and Na-Cl-$SO_4$, which was caused by sea spray and water-rock interaction. Especially, high ratio of Na content in groundwater resulted from ion exchange. For redox condition of groundwater, the values of DO and Eh decreased with depth, which indicated that reducing condition was formed in deeper groundwater. In addtion, high concentration of Fe and Mn showed that redox condition of groundwater was controlled by the reduction of Fe and Mn oxides.

  • PDF

Determination of 10${\alpha}$-Methoxy-9,10-dihydrolysergol (MDL), Main Metabolite of Nicergoline, in Human Plasma by HPLC-MS and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC-MS를 이용한 생체시료 중 니세르골린의 주대사체인 10${\alpha}$-Methoxy-9,10-dihydrolysergol(MDL)의 분석 및 이를 이용한 한국인 성인 남성에 대한 생체이용률 응용)

  • Lim, Hyon-Kyun;Yoo, Sun-Dong;Kim, Kyeong-Ho;Han, Sang-Beom;Youm, Jeong-Rok
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.133-139
    • /
    • 2007
  • A simple and sensitive HPLC-MS method for quantitation of 10${\alpha}$-methoxy-9,10-dihydrolysergol (MDL), the main metabolite of nicergoline, in human plasma was developed and the bioavailability parameters of MDL was assessed in Korean healthy male volunteers. Clomipramine was used as an internal standard. MDL and internal standard in plasma sample were extracted using ethyl acetate. A centrifuged upper layer was then evaporated and reconstituted with mobile phase of 10 mM ammonium acetate-acetonitrile (10 : 90, v/v). The reconstituted samples were injected into a Zorbax SB-C8 column (2.1${\times}$150 mm,5 ${\mu}$m) at a flow-rate of 0.3 ml/min. Using MS with selected ion monitoring (SIM) mode, MDL and clomipramine were detected without severe interference from human plasma matrix. MDL produced a protonated molecular ion ([M+H]$^+$) at m/z 287. Internal standard produced a protonated molecular ion ([M+H]$^+$) at m/z 315. A linear relationship for MDL was found in the range of 2.5${\sim}$100 ng/ml. The lower limit of quantitation (LLOQ) was 2.5 ng/ml with acceptable precision and accuracy. The intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 30 mg of nicergoline were revealed as follows: AUC$_t$ 321.1${\pm}$64.5 ng${\cdot}$hr/ml, C$_{max}$, 51.2${\pm}$25.3 ng/ml, T$_{max}$ 3.6${\pm}$1.5 hr, K$_{el}$ 0.12${\pm}$0.07 hr$^{-1}$ and t$_{1/2}$ 7.6${\pm}$3.4 hr. Inter subject variations and race differences were shown in comparison with the published data in the literature.

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

Analysis of some pesticides in urine by GC/MS (GC/MS를 이용한 뇨중 몇가지 농약의 분석)

  • Park, Seong-Soo;Park, Song-Ja;Pyo, Hee-Soo;Cho, Jung-Hee;Kim, Hye-Soo;Park, Taek-Kyu
    • The Korean Journal of Pesticide Science
    • /
    • v.4 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • The purpose of this study is to establish the assessment techniques of hazardous chemicals by the development of analytical method of biological samples. In this study, we have developed an extraction method of nine pesticides used for rice paddy that resulted in high recovery from the spiked human urine by the liquid-liquid extraction with diethyl ether at pH 7.0. Calibration curve obtained from each pesticide standard using by gas chromatography/mass spectrometry/selected ion monitoring has shown good linearity and detection limits were the range of $0.4{\sim}2.0$ ng/mL in urine. As a biological monitoring, urine samples of local farmers exposed directly to nine pesticides in the field were collected and analyzed by GC/MS. Of the tested pesticides, metabolites of phenthoate assumed were identified by GC/MS analysis. No parent compound was detected.

  • PDF