• 제목/요약/키워드: See reference

검색결과 161건 처리시간 0.026초

Electrical Properties of Organic Light-emitting Diodes Using TCNQ Molecules (TCNQ 분자를 이용한 유기 발광 소자의 전기적 특성)

  • Na, Su-Hwan;Kim, Tae-Wan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제23권11호
    • /
    • pp.896-900
    • /
    • 2010
  • Electrical properties of organic light-emitting diodes were studied in a device with 7,7,8,8-tetracyano-quinodimethane (TCNQ) to see how the TCNQ affects on the device performance. Since the TCNQ has a high electron affinity, it is used for a charge-transport and injection layer. We have made a reference device in a structure of ITO(170 nm)/TPD(40 nm)/$Alq_3$(60 nm)/LiF(0.5 nm)/Al(100 nm). And two types of devices were manufactured. One type of device is the one made by doping 5 and 10 vol% of TCNQ to N,N'-diphenyl-N,N'-di(m-tolyl)-benzidine (TPD) layer. And the other type is the one made with TCNQ layer inserted in between the ITO anode and TPD organic layer. Organic layers were formed by thermal evaporation at a pressure of $10^{-6}$ torr. It was found that for the TCNQ doped devices, turn-on voltage of the device was reduced by about 20 % and the current efficiency was improved by about three times near 6 V. And for devices with TCNQ layer inserted in between the ITO anode and TPD layer, it was found that the current efficiency was improved by more than three times even though there was not much change in turn-on voltage.

ALGORITHM OF REVISED-OTFTOOL

  • Chung Eun-Jung;Kim Hyor-Young;Rhee Myung-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • 제23권3호
    • /
    • pp.269-288
    • /
    • 2006
  • We revised the OTFTOOL which was developed in Five College Radio Astronomy Observatory (FCRAO) for the On-The-Fly (OTF) observation. Besides the improvement of data resampling function of conventional OTFTOOL, we added a new SELF referencing mode and data pre-reduction function. Since OTF observation data have a large redundancy, we can choose and use only good quality samples excluding bad samples. Sorting out the bad samples is based on the floating level, rms level, antenna trajectory, elevation, $T_{sys}$, and number of samples. And, spikes are also removed. Referencing method can be chosen between CLASSICAL mode in which the references are taken from the OFFs observation and ELLIPSOIDAL mode in which the references are taken from the inner source free region (this is named as SELF reference). Baseline is subtracted with the source free channel windows and the baseline order chosen by the user. Passing through these procedures, the raw OTF data will be an FITS datacube. The revised-OTFTOOL maximizes the advantages of OTF observation by sorting out the bad samples in the earliest stage. And the new self-referencing method, the ELLIPSOIDAL mode, is very powerful to reduce the data. Moreover since it is possible to see the datacube at once without moving them into other data reduction programs, it is very useful and convenient to check whether the data resampling works well or not. We expect that the revised-OTFTOOL can be applied to the facilities of the OTF observation like SRAO, NRAO, and FCRAO.

Current-Voltage-Luminance Characteristics of Organic Light-Emitting Diodes with a Variation of PVK Concentration Used as a Buffer Layer (버퍼층으로 사용한 PVK의 농도 변화에 따른 유기 발광 소자의 전압-전류-휘도 특성)

  • Kim, Sang-Keol;Hong, Jin-Woong;Kim, Tae-Wan
    • Journal of the Korean Applied Science and Technology
    • /
    • 제19권1호
    • /
    • pp.68-72
    • /
    • 2002
  • We have seen the effects of buffer layer in organic light-emitting diodes(OLEDs) using poly(N-vinylcarbazole)(PVK) depending on a concentration of PVK. Polymer PVK buffer layer was made using spin casting technique. Two device structures were fabricated; one is ITO/TPD/$Alq_{3}$/Al as a reference, and the other is ITO/PVK/TPD/$Alq_{3}$/Al to see the effects of buffer layer in organic light-emitting diodes. Current-voltage-luminance characteristics and an external quantum efficiency were measured with a variation of spin-casting rpm speeds and PVK concentration. We have obtained an improvement of external quantum efficiency by a factor of four when the PVK concentration is 0.1wt% is used. The improvement of efficiency is expected due to a function of hole-blocking of PVK in OLEDs.

Effects of Buffer layer in Organic Light-Emitting Diodes (유기 전기발광 소자에서 버퍼층이 미치는 영향)

  • 김상걸;정동회;이호식;정택균;김태완;민항기;박종욱;송미종;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.174-177
    • /
    • 2001
  • We have seen the effects of buffer layer in organic light-emitting diodes using poly(N-vinylcarbazole)(PVK). Polymer PVK buffer layer was made using spin casting techniques. Two different types of spin casting have been applied; static coating and dynamic coating. Two device structures were fabricated; one is ITO/TPD/Alq$_3$/Al as a reference, and the other is ITO/PVK/TPD/Alq$_3$/Al to see the effects of buffer layer in organic light-emitting diodes. Current-voltage characteristics and luminous efficiency were measured with a variation of spin-casting methods and rpm speeds. We have obtained an improvement of luminous efficiency by a factor of two and half when the PVK buffer layer is used.

  • PDF

A Study on the Interface Properties of Metal/Organic Films/Metal (Metal/Organic Films/Metal에서 계면특성에 관한 연구)

  • Song, Jin-Won;Cho, Su-Young;Choi, Young-Il;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.723-726
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-$\gamma$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

INTRAFAMILIAL TRANSMISSION OF ACTINOBACILLUS ACTINOMYCETEMCOMITANS IN KOREAN POPULATIONS (한국인에 있어서 Actinobacillus actinomycetemcomitans의 가족내 전이양상에 관한 연구)

  • Jeong, Young-In;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.679-693
    • /
    • 1995
  • The present study has been performed to see the intrafamilial transmission of periodontopathic organism Actinobacillus actinomycetemcomitans in Koreans having various froms of periodontal diseases. 17 clinical isolates from 8 periodontal patients and 20m clinical isolates from their 8 family members were grown anaerobically for the serotyping and the extraction of genomic DNA. The DNA was digested with restriction endonucleases (EcoRI+HindIII) and plasmid pAA 2097(kindly provided by Dr. DiRienzo, Univ. of Pennsylvania) including 4.7kb-size randlomly clone probe for restriction length pleomorphism analysis(RFLP). RFLP patterns of reference serotypes a, b, c, d, and e were used as the genotypes A, B, C, D, and E, respectively for comparison of genotypes of clinical isolates. 28 out of total 37 clinical isoltes belonged to either one of 5 basic gentotypes and 9 remaining isolats did not fall into any types, and hence were designate as non-type(NT). Genotype C were the most frequently found one(35.1%) and genotype B has not isolated. Intrafamilial transmission of bacteria between spouses, brothers and sisters, and parents and their offsprings, resepctively could well be demonstrated by comparing RFLP patterns. There were not any specific genotypes which showed predominance over others in terms of transmission.

  • PDF

A Study on the Research Methods in History of Costume (복식사 연구방법에 관한 소고(I))

  • 신상옥
    • Journal of the Korean Home Economics Association
    • /
    • 제18권4호
    • /
    • pp.41-45
    • /
    • 1980
  • We must identify the forms of dress devised throughout ages, when we wtudy, interpret and analyze the numerous resource material of costume. The study which depends on reference to actual artifacts is necessarily limited. Whereas items of contemporary dress are readily available, much from earlier eras has been destroyed or has deteriorated through time. Such as cottons, linens, silks, wools, leathers and furs are perishable organic materials. Few garments dated earlier than seventeenth century has survived except armor, jewelry. We have many sources of the information are available to study on costume of earlier eras. These sources are wall paintings, sculptures, painting, monumental brasses, manuscript illustration ceramics, coins, medals, mosaics, archives, literature. Wall painting and frescoes provided an useful source for costume study. Many wall paintings and frescoes were destroyed, were changed in color. It si advisable to interpret the dress detail, form color carefully. Sculpture would be useful to see the back and side views of dress. One of the most important points which should be made abut the use of sculpture as a source for costume study in early periods is that the sculptor's style will often change the character of a costume. As the painting si two-dimensional evidence for a three-dimensional costume, paintings must be accurately studied. What we must do, as far as we can, is to look at all visual representations in the light of other contemporary evidence in order to interpret the information correctly.

  • PDF

Survey of Electro-Optical Infrared Sensor for UAV

  • Jang, Seung-Won;Kim, Joong-Wook
    • Current Industrial and Technological Trends in Aerospace
    • /
    • 제6권1호
    • /
    • pp.124-134
    • /
    • 2008
  • The rising demand for the high efficiency and high covertness in UAV motivates the miniature design of the high performing mission sensors, or payloads. One of the promising payload sensors, EO/IR sensor has evolved satisfying its demands and became the main stand-alone mission sensor for 200kg-range UAV. One aspect in development of EO/IR sensor concerns lack of specification criterions to represent its performance. Even though the high demand and competition among each manufacturer caused EO/IR features subject to rapid change collateral to new technology, the datasheets maintained the conventional outdated formats which leave some of the major components in ambiguity. Making comparisons or predicting actual performance with such datasheets is hardly worthwhile; yet, they could be important reference guide for the potential customers what to expect for the upcoming EO/IR. According to UAS Roadmap 2007-2032 published by DoD, one of the main potential customers as well as a main investor of EO/IR technology, EO/IR is expected to play key roll in solving urgent problems, such as see and avoid system. This paper will examine the recent representative EO/IR specialized in UAS missions through datasheets to find out current trend and eventually extrapolate the possible future trend.

  • PDF

Detection and Identification of $\beta$-lactamase, Enterotoxin and Other Exotoxins Genes of Staphylococcus aureus by PCR

  • Yoon, Y.H.;Kim, K.I.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권3호
    • /
    • pp.425-429
    • /
    • 2003
  • Staphylococcus aureus is a major pathogen for cattle, causing various forms of subclinical and clinical mastitis and could be a causative agent of food poisoning, it produces various superantigenic exotoxins which have a great public health significance. A total of 72 S. aureus clinical isolates from dairy farms located in Kyunggi Province Korea were examined for the species identification by biochemical method, and for the detection of $\beta$-lactamase, enterotoxin and other exotoxins genes by PCR. The results of species identification by biochemical method agreed with those of PCR done with species specific primer STA-AU. $\beta$-lactamase is an enzyme closely associated with the resistance to antibiotic penicillin, which is an important means of treatment of mastitis, all the isolates were positive for the presence of genes encoding $\beta$-lactamase, which were reproduced in penicillin susceptibility disc assay. Six types of toxin genes, Staphylococcal enterotoxin (SE)A, SEB, SEC, SEE, toxic shock syndrome toxin (TSST-1) and exfoliative toxin A (ET A) were detected in 72 isolates by PCR associated genotypic method in this study, none of the isolates carried the genes for enterotoxin D (SED) and exfoliative toxin B (ETB). The occurrence rate of exotoxin genes rated as 12.5%, and the precision of the PCR identification results has been confirmed using the reference strains.

Robotic Guidance of Distal Screwing for Intramedullary Nailing Using Optical Tracking System (광학식측정장치를 이용한 금속정 내고정 수술의 원위부 나사체결을 위한 로보틱 유도 시스템)

  • An, Liming;Kim, Woo Young;Ko, Seong Young
    • The Journal of Korea Robotics Society
    • /
    • 제12권4호
    • /
    • pp.411-418
    • /
    • 2017
  • During the intramedullary nailing procedure, surgeons feel difficulty in manipulation of the X-ray device to align it to axes of nailing holes and suffer from the large radiation exposure from the X-ray device. These problems are caused by the fact the surgeon cannot see the hole's location directly and should use the X-ray device to find the hole's location and direction. In this paper, we proposed the robotic guidance of the distal screwing using an optical tracking system. To track the location of the hole for the distal screwing, the reference marker is attached to the proximal end of an intramedullary nail. To guide the drill's direction robustly, the 6-degree-of-freedom robotic arm is used. The robotic arm is controlled so as to align the drill guiding tool attached the robotic arm with the obtained the hole's location. For the safety, the robot's linear and angular velocities are restricted to the predefined values. The experimental results using the artificial bones showed that the position error and the orientation error were 0.91 mm and $1.64^{\circ}$, respectively. The proposed method is simple and easy to implement, thus it is expected to be adopted easily while reducing the radiation exposure significantly.