• Title/Summary/Keyword: Sectional model

Search Result 1,215, Processing Time 0.028 seconds

Artificial Injection to Control Saltwater Intrusion in Groundwater-Numerical Study on a Vertical Cross Section (지하수 해수쐐기 제어를 위한 인공주입-연직 2차원 단면 수치실험)

  • Hong, Sung-Hoon;Shi, Lei;Cui, Lei;Park, Nam-Sik
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 2009
  • A simulation-optimization model is developed for development of groundwater and control of a saltwater wedge for protecting over-exploiting freshwater pumping wells. To achieve the goal an objective function is developed for three types of wells: freshwater pumping, freshwater injection and saltwater pumping. Integrity of groundwater environment is accounted for by including three indices. Illustrative cross-sectional examples show that both types of barriers can protect freshwater pumping wells from saltwater intrusion. A barrier well operating at the same rate located anywhere within a certain reach can protect a pumping well. However, the location of the reach appears to contradict the common practice of barrier placements. Consideration of the groundwater environment yields a unique optimal location for barrier wells.

Fatigue Safe Life Analysis of Helicopter Bearingless Rotor Hub Composite Flexbeam (헬리콥터 무베어링 로터 허브 복합재 유연보 피로 안전수명 해석)

  • Kim, Taejoo;Kee, Youngjoong;Kim, Deog-Kwan;Kim, Seung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.7
    • /
    • pp.561-568
    • /
    • 2013
  • After we designed Bearingless rotor hub system for 7,000lb class helicopter, flexbeam fatigue analysis was conducted for validation of requirement life time 8,000 hours. sectional structural analysis method applying elastic beam model was used. Fatigue analysis for two sections of flexbeam which were expected to weak to fatigue damage from result of static analysis was conducted. Extension, bending and torsion stiffness of flexbeam section shape was calculated using VABS for structure analysis. S-N curve of two composite material which composed flexbeam was generated using wohler equation. Load analysis of bearingless rotor system was conducted using CAMRAD II and load analysis result was applied HELIX/FELIX standard load spectrum to generate bearingless rotor system load spectrum which was used flexbeam fatigue safe life analysis.

Interaction Between Persistent Organic Pollutants and C-reactive Protein in Estimating Insulin Resistance Among Non-diabetic Adults

  • Kim, Ki-Su;Hong, Nam-Soo;Jacobs, David R. Jr.;Lee, Duk-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.2
    • /
    • pp.62-69
    • /
    • 2012
  • Objectives: Chronic inflammation is now thought to play a key pathogenetic role in the associations of obesity with insulin resistance and diabetes. Based on our recent findings on persistent organic pollutants (POPs) including the lack of an association between obesity and either insulin resistance or diabetes prevalence among subjects with very low concentrations of POPs, we hypothesized that POP concentrations may be associated with inflammation and modify the associations between inflammation and insulin resistance in non-diabetic subjects. Methods: Cross-sectional associations among serum POPs, C-reactive protein (CRP), and homeostasis model assessment of insulin resistance (HOMA-IR) were investigated in 748 non-diabetic participants aged ${\geq}20$ years. Nineteen types of POPs in 5 subclasses were selected because the POPs were detectable in ${\geq}60%$ of the participants. Results: Among the five subclasses of POPs, only organochlorine (OC) pesticides showed positive associations with CRP concentrations, while polychlorinated biphenyls (PCBs) showed inverse associations with CRP concentrations. There were statistically significant interactions between CRP and OC pesticides and between CRP and PCBs, in estimating HOMA-IR (P for interaction <0.01 and <0.01, respectively). CRP was not associated with HOMA-IR among subjects with low concentrations of OC pesticides or PCBs, while CRP was strongly associated with HOMA-IR among subjects with high concentrations of these POPs. Conclusions: In the current study, OC pesticides were associated with increased levels of CRP, a marker of inflammation, and both OC pesticides and PCBs may also modify the associations between CRP and insulin resistance.

Acute Health Effects of the Hebei Oil Spill on the Residents of Taean, Korea (허베이 스피리트호 유류유출사고 지역주민의 급성건강영향)

  • Lee, Cheol-Heon;Kang, Young-A;Chang, Kyu-Jin;Kim, Chang-Hoon;Hur, Jong-Il;Kim, Jae-Youn;Lee, Jong-Koo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.2
    • /
    • pp.166-173
    • /
    • 2010
  • Objectives: On December 7, 2007, the Hebei Spirit oil tanker spilled out 12,547 kl of crude oil on the Yellow Sea 10 km away from the cost of Taean Province, Korea. As the coastline has been contaminated, local residents have been exposed to crude oil. Because the residents were showing many symptoms, we investigated the acute health effects of this oil spill on them. Methods: We conducted a cross-sectional study consisting of the heavy and moderately oil soaked area in Taean and the lightly oil soaked area in Seocheon. Ten seashore villages were selected from each area, and 10 male and female adults were selected from each village. We interviewed the subjects using a structured questionnaire on the characteristics of residents, the cleanup activities, the perception of oil hazard, depression and anxiety, and the physical symptoms. The odds ratios and 95% confidence intervals were analyzed using logistic regression analysis. The logistic regression model was adjusted for age, gender, education, smoking, the perception of oil hazard and anxiousness. Results: The more highly contaminated the area, the more likely it was for residents to be engaged in cleanup activities and have a greater chance of exposure to oil. The indexes of anxiety and depression were higher in the heavy and moderately oil soaked areas. The increased risks of headache, nausea, dizziness, fatigue, tingling of limb, hot flushing, sore throat, cough, runny nose, shortness of breath, itchy skin, rash, and sore eyes were significant. Conclusions: The results suggest that exposure to crude oil is associated with various acute physical symptoms. Long-term investigation is required to monitor the residents' health.

A Model-Analysis for Removal of Fire Fumes in a Road Tunnel during a Fire Disaster (도로터널내 화재 발생시 매연 제거를 위한 모델 해석)

  • 윤성욱;이희근
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 1997
  • In case of a fire outbreak in a uni-directional road tunnel, the flow of traffic immediately behind the fire disaster will be stalled all the way back to the entrance of the tunnel. Furthermore, when the vehicle passengers try to flee away from the fire toward the entrance of the tunnel, the extremely hot fume that propagates in the same direction will be fatal to the multitudes evacuating, but may also cause damage to the ventilation equipments and the vehicles, compounding the evacuation process. This paper will present the 3-dimensional modelling analysis of the preventive measures of such a fume propagation in the same direction as the evacuating passengers. For the analysis, the fire hazard was assumed to be a perfect combustion of methane gas injected through the 1 m X 2 m nozzle in the middle of the tunnel, and the product of $CO_2$ as the indicator of the fume propagation. From the research results, when the fire hazard occurred in middle of the 400 m road tunnel, the air density decreased around the fire point, and the maximum temperatures were 996 K and 499 K at 210 m and 350 m locations, respectively, 60 seconds after fire disaster occurred, when the fumes were driven out only towards the exit-direction of the tunnel. By tracing the increase of $CO_2$ level over 1% mole fraction, the minimum longitudinal ventilation velocity was found to be 2.40 m/sec. Furthermore, through Analysis of the temperature distribution graphs, and observation of the cross-sectional distribution of $CO_2$ over 1% mole fraction, it was found that the fume did not mix with the air, but rather moved far in a laminar flow towards exit of the tunnel.

  • PDF

Cutaneous Leishmaniasis Situation and Predicting the Distribution of Phlebotomus papatasi and P. sergenti as Vectors of Leishmaniasis in Ardabil Province, Iran

  • Khamesipour, Ali;Molaei, Soheila;Babaei-Pouya, Navid;Moradi-Asl, Eslam
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.3
    • /
    • pp.229-236
    • /
    • 2020
  • Cutaneous leishmaniosis (CL) is the most common form of leishmaniasis.CL caused by L. major and L. tropica is endemic in 17 provinces of Iran. This study was carried out to elucidate situation of CL in Ardabil province and to predict distribution of Phlebotomus papatasi and Phlebotomus sergenti (Diptera: Psychodidae) as vectors of CL in the region. In this cross-sectional study, data on CL patients were collected from local health centers of Ardabil province, Iran during 2006-2018 to establish a geodatabase using ArcGIS10.3. A total of 20 CL cases were selected randomly and skin samples were collected and analyzed by PCR method. MaxEnt 3.3.3 model was used to determine ecologically suitable niches for the main vectors. A total, 309 CL human cases were reported and the highest incidence rate of disease was occurred in Bilasavar (37/100,000) and Germi (35/100,000). A total of 2,794 sand flies were collected during May to October 2018. The environmentally suitable habitats for P. papatasi and P. sergenti were predicted to be present in northern and central areas of Ardabil province. The most variable that contributed ratio in the modeling were Isothermality and slope factors. Ardabil province is possibly an endemic are for CL. The presence of P. papatasi and P. sergenti justifies local transmission while the vectors of CL are existing in the northern and central areas of the province.

Performance Prediction of Heat Regenerators with using Spheres: Relation between Heat Transfer and Pressure Drop (구형 축열체를 사용한 축열기의 성능예측: 압력손실과 열전달의 관계)

  • 조한창;조길원;이용국
    • Journal of Energy Engineering
    • /
    • v.12 no.1
    • /
    • pp.35-41
    • /
    • 2003
  • Heat regenerator occupied by regenerative materials improves thermal efficiency of regenerative combustion system through the recovery of heat of exhaust gaset. By using one-dimensional two-phase fluid dynamics model, the unsteady thermal flow of heat regenerator with spherical particles, was numerically simulated to evaluate the heat transfer and pressure drop and thereby to suggest the parameter for designing heat regenerator. It takes about 7 hours for the steady state of the flow field in regenerator, in which heat absorption of regenerative particle is concurrent with the same magnitude of heat desorption. The regenerative particle experiences small temperature fluctuation below 10 K during the reversing process. The performance of thermal flow in heat regenerator varies with inlet velocity of exhaust gas and air, configuration of regenerator (cross-sectional area and length) and diameter of regenerative particle. As the gas velocity increases, the heat transfer between gas and particle enhances and with the increase the pressure losses. As particle diameter decreases, the air is preheated higher and the exhaust gases are cooled more with the increase of pressure losses.

Design and Performance Test of Savonius Tidal Current Turbine with CWC (사보니우스형 조류발전 터빈의 설계 및 회류수조 실험을 통한 성능평가)

  • Jo, Chul-Hee;Lee, Jun-Ho;Rho, Yu-Ho;Ko, Kwang-Oh;Lee, Kang-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.37-41
    • /
    • 2012
  • Due to global warming, the need to secure alternative resources has become more important nationally. Because of the very strong current on the west coast, with a tidal range of up to 10 m, there are many suitable sites for the application of TCP (tidal current power) in Korea. In the southwest region, a strong current is created in the narrow channels between the numerous islands. A rotor is an essential component that can convert tidal current energy into rotational energy to generate electricity. The design optimization of a rotor is very important to maximize the power production. The performance of a rotor can be determined using various parameters, including the number of blades, shape, sectional size, diameter, etc. There are many offshore jetties and piers with high current velocities. Thus, a VAT (vertical axis turbine) system, which can generate power regardless of flow direction changes, could be effectively applied to cylindrical structures. A VAT system could give an advantage to a caisson-type breakwater because it allows water to circulate well. This paper introduces a multi-layer vertical axis tidal current power system. A Savonius turbine was designed, and a performance analysis was carried out using CFD. A physical model was also demonstrated in CWC, and the results are compared with CFD.

A Study on the Thermal Environment Evaluation of 'Hanok' considering Solid Model of Building Elements (한옥의 건축요소 솔리드 모델링을 통한 열환경 평가에 관한 연구)

  • Park, Tong-So;Sheen, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.955-961
    • /
    • 2013
  • This study aimed for the scientific approach of Korean traditional house, so called Hanok, by analyses of structural elements and thermal environmental performance. Hanok is a very unique vernacular architectural style of the Middle East Asia that fits with climate conditions of the Korean Peninsular, designed to withstand high temperature and humidity in summer and cold and dry in winter seasons. In order to evaluate thermal environment of Hanok, its sectional structure such as floor, wall, roof structure and Ondol which is Korean traditional floor heating system, was built in 3D, as well as heat transfer mechanism of its composing elements was analyzed through 3 dimensional steady state analysis. The results of the thermal environmental performance of Hanok will be used as a basic datum of design guidelines for accomplishing ecologic housing fitted with local climate.

The impact of liquidity constraints on investment expenditures: Evidences from family and non-family firms (유동성 제약이 투자지출에 미치는 영향: 가족기업과 비가족기업의 실증 비교)

  • Kim, Choong-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.674-680
    • /
    • 2013
  • This paper investigates the impact of liquidity constraints on investment expenditures of family and non-family firms. We analyze the ownership structure of family firms to determine whether family control alleviates or exacerbates investment-cash flow sensitivity in domestic firms. To examine the impact of liquidity constraints on investment expenditures of family and non-family firms, we used a financial data of 644 Korea Exchange traded companies over the 2000 - 2010 period. We estimated a time-series and cross-sectional regression model, using samples of family firms and non-family firms. The results show that cash flow is not associated with investment expenditure in family firms, whereas cash flow has a positive impact on investment in non-family firms. Our results show that lower or no investment-cash flow sensitivities in family-controlled firms are mainly attributable to lower agency costs through strong monitoring activities of family members. Higher investment-cash flow sensitivities are observed in non-family firms with more agency problems. This suggests that investment-cash flow sensitivities would be useful measures of liquidity constraints.