• Title/Summary/Keyword: Sectional measurement

Search Result 406, Processing Time 0.027 seconds

주요 수간곡선식 비교에 따른 남부지역 곰솔 수간재적표 개발 (Developing Stem Volume Table of Pinus thunbergii Parl. in Southern Region Based on Comparison of Major Taper Equations)

  • 김현수;정수영;이광수
    • 한국환경과학회지
    • /
    • 제33권7호
    • /
    • pp.453-462
    • /
    • 2024
  • This study was carried out for the purpose of selecting the most appropriate taper equation for the actual stands of Pinus thunbergii in the southern coastal region of Korea and then developing a stem volume table to provide basic data for rational management. To develop a volume table of Pinus thunbergii in this region of Korea, 59 sample trees with various diameter distributions were selected and stem analysis was performed. As a result of stem analysis, two trees with abnormal diameter and height growth as the age increased were rejected, and 57 trees were analyzed. To develop the taper equation, seven major variable exponential equations were used, including Kozak 1988, 1994, 2001, 2002, Bi 2000, Muhairwe 1999, and Sharma and Parton 2009. As a result of parameter estimation and statistical verification, the Kozak 1988 model showed the highest goodness of fit with Fit I (Fit Index), RMSE 1.5620, Bias 0.0031, and MAD 1.0784. The diameter of each 10cm stem ridge for the selected model was estimated, and a stem volume table was produced using the mensuration of division (end area formula) using the Smalian equation. As a result of two-sample T-test for volume table of this study and current yield table, the volume for this study was found to be significantly larger at all observation points (p < 0.001). Even for the same tree species, it is judged that differentiated volume tables are needed for each growth environment characteristic.

섬진강상류 유량측정지점의 유수단면적과 유량변화에 따른 상관관계 분석 (Analysis of Correlation with Cross Sectional Area of Flow and Flow Rate Variation of Discharge Measurement Point in the Upper Stream of Seomjin River)

  • 송광덕;김갑순;이동진;함상인;김대영;오태윤;이재춘;임병진
    • 생태와환경
    • /
    • 제46권1호
    • /
    • pp.94-102
    • /
    • 2013
  • 본 연구는 단면변화를 고려한 수위-단면적 변화 및 평균 유속-단면적 간의 상관관계를 분석하여 유량 산정 및 하천관리에 활용하고자 하였다. 수위에 따른 단면적 변화는 SB-A 지점은 1.0 m, 1.9 m, SB-C 지점은 0.6 m, 1.8 m, CL-A 지점은 1.0 m, 1.8 m, OS-A 지점은 0.6 m, 2.0m에서 발생되었다. 이 중 첫 번째 변화는 평 저수기에 해당되고, 두 번째 변화는 홍수기 및 하천 좌 우 안에 인위적 자연적으로 형성된 둔치 등으로 판단된다. 수위-단면적 변화에 따른 관계식의 기울기는 지수형 0.5539~1.9013, 선형 9.040~52.544의 범위를 가진다. 기울기는 두 곡선 모두 고수위로 갈수록 증가하는 경향을 보인다. 평균유속-단면적 변화의 관계는 지수와 직선의 방정식으로 지수형 기울기와 상관계수는 각각 0.1182~0.8734, 0.22~0.86이며, 선형의 기울기와 상관계수는 0.0028~0.1032, 0.20~0.87로 분석되었다. SB-A, SB-C 지점의 저수위는 다른 수위보다 상관관계가 높게 산정되었는데, 이는 수위구간이 좁고, 하천 단면적의 변화가 크지 않기 때문으로 판단된다. CL-A, OS-A 지점은 월류보의 영향으로 저수위일 경우에 상관관계가 낮았다. 수위-단면적, 평균유속-단면적의 상관관계 및 곡선식 등을 이용하여 하천 정비계획 등의 수립에 활용할 수 있으며, 제외지의 단면적이 변하는 지점의 유량 변화 등의 예측에 활용할 수 있을 것이다.

수중글라이더를 활용한 동해 최초 연속 물성 단면 관측 보고 (Report about First Repeated Sectional Measurements of Water Property in the East Sea using Underwater Glider)

  • 임규창;박종진
    • 한국해양학회지:바다
    • /
    • 제29권1호
    • /
    • pp.56-76
    • /
    • 2024
  • 동해에서 수행된 국내 최장기 수중글라이더 운용 및 연속 단면 관측 결과를 보고한다. 본 연구팀은 수중글라이더를 활용하여 2020년 9월 18일부터 12월 21일까지 총 95일 동안 국립수산과학원(NIFS) 정선 관측 106 라인에 거의 일치하는 37.9 °N 위도선을 따라 동경 129.1 °E ~ 131.5 °E 사이를 6회 왕복하는 국내 최초의 연속 물성 단면 관측을 성공리에 수행하였다. 본 수중글라이더는 2020년 9월 18일 129.1 °E 위치에서 투하되어 9월 19일부터 88일간의 비행 관측을 수행하였고, 2020년 12월 15일부터 6일간 129.2 °E 위치에서 위치 제어 유지(Virtual Mooring)후 회수되며 전체 운용을 마무리하였다. 표층부터 800 dbar 수심까지 톱니형태의 궤적을 그리면서 총 수평거리 2550 km를 비행하는 동안 글라이더의 경로 이탈은 RMS 거리 262 m를 벗어나지 않을 정도의 매우 안정적인 경로 추종 모드를 보여줬다. 비행 관측을 통해 획득한 총 12개의 고해상도 물성 횡단면 자료로부터 수온과 염분의 연속적인 변동이 보이는 아중규모 특성을 확인하였고, 국립수산과학원(NIFS)의 격월 선박 관측 자료와 비교함으로써 시공간 해상도 차이에 따른 뚜렷한 특성을 발견하였다. 첫째는 공간 해상도 차이에 따른 결과로 표층 전선역의 세기 및 이동, 수온약층 강화현상 등 아중규모 현상들이 글라이더 횡단면 자료에서만 뚜렷하게 관찰되었다. 이러한 아중규모 구조는 현행 선박 관측 자료의 정점 간격(25 km) 보다 작다는 특징이 있었는데, 동해 내 아중규모 구조의 이해를 위해서는 고해상도 관측이 필요함을 의미한다. 둘째는 시간 해상도 차이에 따른 결과로 글라이더 자료에서 추출한 평균 7일 간격의 수온과 염분 시계열이 대략 6주 주기를 갖는 월중변동(Intramonthly variation) 특성을 보인다는 것과 대략 1주 동안 급격한 관측치의 변동이 나타난다는 것을 확인하였다. 이는 격월 정선 관측 자료에는 확인되지 않는 특징이다. 따라서, 정선 관측해역의 물성 변동을 이해하기 위해서는 선박 관측과 비교하여 상대적으로 비용이 저렴하고 효율적인 글라이더 관측을 통한 보완이 필요하다고 여겨진다. 마지막으로 두 플랫폼 간 관측치의 편차를 확인하였는데, 이러한 편차의 요인을 공간 규모에 기초한 정점의 정의 및 시간 규모에 따른 변동성, 그리고 각 플랫폼의 CTD 측정 장비의 교정 관점에서 논하였다.

침치료 직 후 자가 설문지를 이용한 침반응(針感)과 부작용에 대한 단면적 연구 (Short Tenn Reactions to Acupuncture Treatment and Adverse Events Following Acupuncture in Korea a Cross-sectional Survey of Patient Reports)

  • 박성욱;정우상;문상관;고창남;조기호;김영석;배형섭;박정미
    • 대한한의학회지
    • /
    • 제28권2호통권70호
    • /
    • pp.66-79
    • /
    • 2007
  • Objectives : To explore the type and frequency of short term reactions, de Qi associated with acupuncture treatment and to determine the incidence of adverse events following acupuncture in Korea. Subjects and methods : This study is a retrospective and cross-sectional survey of patient reports. 1095 subjects, 585 of out-patients of the Oriental Medicine of Stroke & Neurological Disorders Center, East-West NEO Medical Center of Kyunghee University and 510 of out-patients of the Department of Cardiovascular & Neurologic Diseases (Stoke Center), Hospital of Oriental Medicine, Kyunghee Medical Center, from June through November of 2006, who had acupuncture, gave informed consent and completed one survey form. On this form, patients were asked to report short term acupuncture reactions, de Qi, patient satisfaction measurement (using VAS), and adverse events relating to acupuncture treatment. The acupuncturists of this study are Korean Medicine Doctors (KMD) who had worked as practitioners for 3-30 years or more. Results : The average age of the 1095 subjects was 58 years old. Positive short term acupuncture reactions after treatment were reported by 878 (80.2%), negative short term acupuncture reactions by 75 (6.8%) and no reactions were reported by 142 (13.0%). The most common positive short term acupuncture reactions were feeling 'relaxed', 472 (43.1%), followed by feeling 'less pain' 90 (8.2%), 'energized' 16 ( 1.5%), 'tingling' 16 (1.5%), 'heat feeling or Cold feeling' 10 (0.9%), and others 274 (25.0%), respectively. Negative short term acupuncture reactions were feeling 'pain' 37 (3.4%), tiredness 24 (2.2%), dizziness 9 (0.8%), and others 5 (0.2%), respectively. Traditionally described needling sensations of de Qi refer to a patient's response to distention, pulling, soreness, heaviness, numbness. 39.7% of subjects reported de Qi during needling, experiencing 'distention' 333 (30.4%), 'soreness' 52 (4.7%), 'pulling' 22 (2.0%), 'heaviness' 18 (1.6%), and 'numbness' 10 (0.9%) respectively. Positive short term acupuncture reactions and de Qi rate were the highest in the less than 40 years group (83/96 86.5%, 50/96 52.1%). No acupuncture reactions were highly seen in the over 70 years old group (31/187, 16.6%). Patient satisfaction level using VAS was a comparatively high $72.9{\pm}19.9$. Adverse events were only bleeding in 92 (8.4%) of the total subjects. High sensitive acupoints were 95 points as GV26 (54 times), LI4 (54 times), ST36 (53 times), GB20 (37 times), HT8(34 times), LV3 (29 times), SI3 (29 times), and LI11 (27 times) in order. Main impressions were stroke patients 430 (16.9%), headache 185 (16.9%), hypertension 97 (8.9%), and dizziness 85 (7.8%). Conclusions : Although 8 different Korean Medicine Doctors participated in this research, we obtained similar results from each. There were no significantly different results between the two hospitals. Short term acupuncture reactions and de Qi were most related to age. Except for bleeding there were no adverse events relating to acupuncture treatment in this study. We consider acupuncture treatment as very safe depending on practitioners. Positive short term acupuncture reactions after treatment were 12 times higher than negative short term acupuncture reactions. Subjects were comparatively satisfied with acupuncture treatment.

  • PDF

드론기반 시공간 초분광영상을 활용한 식생유무에 따른 하천 수심산정 기법 적용성 검토 (Evaluation for applicability of river depth measurement method depending on vegetation effect using drone-based spatial-temporal hyperspectral image)

  • 권영화;김동수;유호준
    • 한국수자원학회논문집
    • /
    • 제56권4호
    • /
    • pp.235-243
    • /
    • 2023
  • 하천법 개정 및 수자원의 조사·계획 및 관리에 관한 법률 제정으로 하상변동조사를 정기적으로 실시하는 것이 의무화되었고, 지자체가 계획적으로 수자원을 관리할 수 있도록 제도가 마련되고 있다. 하상 지형은 직접 측량할 수 없기 때문에 수심 측량을 통해 간접적으로 이루어지고 있으며, 레벨측량이나 음향측심기를 활용한 접촉식 방법으로 이루어지고 있다. 접촉식 수심측량법은 자료수집이 제한적이기 때문에 공간해상도가 낮고 연속적인 측량이 불가능하다는 한계가 있어 최근에는 LiDAR나 초분광영상을 이용한 원격탐사를 이용한 수심측정 기술이 개발되고 있다. 개발된 초분광영상을 이용한 수심측정 기술은 접촉식 조사보다 넓은 지역을 조사할 수 있고, 잦은 빈도로 자료취득이 용이한 드론에 경량 초분광센서를 탑재하여 초분광영상을 취득하고, 최적 밴드비 탐색 알고리즘을 적용해 수심분포 산정이 가능하다. 기존의 초분광 원격탐사 기법은 드론의 경로비행으로 획득한 초분광영상을 면단위의 영상으로 정합한 후 특정 물리량에 대한 분석이 수행되었으며, 수심측정의 경우 모래하천을 대상으로 한 연구가 주를 이루었으며, 하상재료에 대한 평가는 이루어지지 않았었다. 본 연구에서는 기존의 초분광영상을 활용한 수심산정 기법을 식생이 있는 하천에 적용하고, 동일지역에서 식생을 제거한 후의 2가지 케이스에 대해서 시공간 초분광영상과 단면초분광영상에 모두 적용하였다. 연구결과, 식생이 없는 경우의 수심산정이 더 높은 정확도를 보였으며, 식생이 있는 경우에는 식생의 높이를 바닥으로 인식한 수심이 산정되었다. 또한, 기존의 단면초분광영상을 이용한 수심산정뿐만 아니라 시공간 초분광영상에서도 수심산정의 높은 정확도를 보여 시공간 초분광영상을 활용한 하상변동(수심변동) 추적의 가능성을 확인하였다.

디지털 임피던스 영상 시스템의 설계 및 구현 (Design and Implementation of Digital Electrical Impedance Tomography System)

  • 오동인;백상민;이재상;우응제
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권4호
    • /
    • pp.269-275
    • /
    • 2004
  • 인체내부의 각 조직은 서로 다른 저항률(resistivity)분포를 가지며, 조직의 생리학적, 기능적 변화에 따라 임피던스가 변화한다. 본 논문에서는 주로 기능적 영상을 위한 임피던스 단층촬영 (EIT, electrical impedance tomography) 시스템의 설계와 구현 결과를 기술한다. EIT 시스템은 인체의 표면에 부착한 전극을 통해 전류를 주입하고 이로 인해 유기되는 전압을 측정하여, 내부 임피던스의 단층영상을 복원하는 기술이다. EIT 시스템의 개발에 있어서는 영상복원의 난해함과 아울러 측정시스템의 낮은 정확도가 기술적인 문제가 되고 있다. 본 논문은 기존 EIT 시스템의 문제점을 파악하고 디지털 기술을 이용하여 보다 정확도가 높고 안정된 시스템을 설계 및 제작하였다. 크기와 주파수 및 파형의 변화 가능한 50KHz의 정현파 전류를 인체에 주입하기 위해 필요한 정밀 정전류원을 설계하여 제작한 결과, 출력 파형의 고조파 왜곡(THD, total harmonic distortion)이 0.0029%이고 진폭 안정도가 0.022%인 전류를 출력 할 수 있었다. 또한, 여러개의 정전류원을 사용함으로써 채 널간 오차를 유발하던 기존의 시스템을 변경하여, 하나의 전류원에서 만들어진 전류를 각 채널로 스위칭하여 공급함으로써 이로 인한 오차를 줄였다. 주입전류에 의해 유기된 전압의 정밀한 측정을 위해 높은 정밀도를 갖는 전압측정기가 필요하므로 차동증폭기, 고속 ADC및 FPGA(field programmable gate array)를 사용한 디지털 위상감응복조기 (phase-sensitive demodulator )를 제작하였다. 이때 병렬 처리를 가능하게 하여 모든 전극 채널에서 동시에 측정을 수행 할 수 있도록 하였으며, 제작된 전압측정기의 SNR(signal-to-noise ratio)은 90dB 이다. 이러한 EIT 시스템을 사용하여 배경의 전해질 용액에 비해 두 배의 저항률을 가지는 물체(바나나)에 대한 기초적인 영상복원 실험을 수행하였다. 본 시스템은 16채널로 제작되었으나 전체를 모듈형으로 설계하여 쉽게 채널의 수를 늘릴 수 있는 장점을 가지고 있어서 향후 64채널 이상의 디지털 EIT시스템을 제작할 계획이며, 인체 내부의 임피던스 분포를 3차원적 으로 영상화하는 연구를 수행 할 예정이다.

$8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발 (Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권2호
    • /
    • pp.184-190
    • /
    • 2008
  • 원전 증기발생기 전열관의 건전성을 평가하기 위해서 여러 가지 와전류검사 기법이 적용되고 있다. 이와 같은 와전류검사 기법중에서 보빈탐촉자 기법은 전열관에 발생할 수 있는 축방향균열, 마모 검사에 적용하고 있으며, MRPC 기법은 튜브시트 상단 및 곡관부위 균열의 정밀검사에 적용된다. 원전 증기발생기 전열관의 설치공정 혹은 운전중에 전열관에 덴트(dent, 혹은 ding) 및 벌지(bulge)가 형성될 수 있으며, 와전류검사에서 이러한 지시는 결함으로 간주하지 않기 때문에 일정 크기 이상의 지시만 검사보고서에 기록하여 관리하고 있다. 이러한 지시는 보빈탐촉자 기법으로 용이하게 검출이 가능하고 보빈단면형상검사에 의해 대략적인 크기의 측정이 가능하지만, 정확한 크기 및 형상은 알 수는 없으므로 본 연구에서는 단면형상검사의 정확도를 증가시키기 위해 $8{\times}1$ 다중코일 탐촉자를 설계 개발하여 그 정확도를 평가하였다. 한편, OPR-1000형 증기발생기 전열관의 튜브시트 확관 천이영역에 형성된 덴트부위에 균열성 결함이 발생할 가능성이 높기 때문에 일부 발전소에서는 예방차원의 슬리빙을 수행하고 있다 이와 같은 슬리빙 대상 전열관 선정시 본 검사기법을 활용하면 유용할 것으로 판단된다.

넓은 덕트 단면내의 음원 분포 규명 (Identification of the Sectional Distribution of Sound Source in a Wide Duct)

  • 허용호;이정권
    • 한국음향학회지
    • /
    • 제33권2호
    • /
    • pp.87-93
    • /
    • 2014
  • 덕트 내 음원 면에서의 음압과 입자 속도분포를 상세히 알 수 있다면, 주된 소음원들의 위치와 강도를 분석하여 전파특성을 잘 이해할 수 있고, 이에 따라 저소음화 설계에 유용한 정보로 활용가능하다. 이를 위한 기존의 방법들은 대개 단면상 위치와 무관한 일정 변수로 나타내는 제한점이 있다. 본 논문에서는 음원의 단면 분포를 높은 공간분해능으로 관찰할 수 있는 방법에 대해 연구하였다. 모드 합성법을 기반으로 감쇠파의 영향과 근접장 측정을 포함하는 행렬식을 유도하였으며, 컴프레션 드라이버에 의해 일부 단면이 가진된 유동이 없는 덕트 시스템에서 검증하였다. 감쇠파모드 개수의 증가에 따라 음압 스펙트럼을 더욱 정확하게 근사화 할 수 있었으며, 26개의 감쇠파 모드를 포함한 수렴 결과로부터 관심 헬름홀쯔 수 영역에서 -25 dB 이하의 오차로 예측할 수 있었다. 수렴된 모드 진폭들을 이용하여 kR = 1에서 음원 면에서의 음원변수 분포를 관찰한 결과, 실제 음원이 설치된 국소 위치에서 높은 음압과 입자 속도 값을 분명히 나타내는 것을 보였다. 또한, 감쇠 모드의 역추산시에 정규화기법을 도입하여, 과결정된 반경방향 모드에 의해 발생된 무의미한 피크들을 효과적으로 제거할 수 있었다.

Ex vivo High-resolution Optical Coherence Tomography (OCT) Imaging of Pleural Reaction after Pleurodesis Using Talc

  • Ahn, Yeh-Chan;Oak, Chulho;Park, Jung-Eun;Jung, Min-Jung;Kim, Jae-Hun;Lee, Hae-Young;Kim, Sung Won;Park, Eun-Kee;Jung, Maan Hong
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.607-613
    • /
    • 2016
  • The pleura is known as an end target organ of exposure to toxic environmental materials such as fine particulate matter and asbestos. Moreover, long-term exposure to hazardous materials can eventually lead to fatal lung disease such as diffuse pleural fibrosis or mesothelioma. Chest computed tomography (CT) and ultrasound are gold standard imaging modalities for detection of advanced pleural disease. However, a diagnostic tool for early detection of pleural reaction has not been developed yet due to difficulties in imaging ultra-fine structure of the pleura. Optical coherence tomography (OCT), which provides cross-sectional images of micro tissue structures at a resolution of 2-10 μm, can image the mesothelium with a thickness of ~100 μm and therefore enables investigation of the early pleural reaction. In this study, we induced the early pleural reaction according to a time sequence after pleurodesis using talc, which has been widely used in the clinical field. The pleural reaction in talc grouped according to the time sequence (1st, 2nd, 4th weeks) showed a significant thickening (average thickness: 45 ± 7.5 μm, 80 ± 10.7 μm, 90 ± 12.5 μm), while the pleural reaction in sham and normal groups showed pleural change from normal to minimal thickening (average thickness: 16 ± 5.5 μm, 17 ± 4.5 μm, 15 ± 6.5 μm, and 12 ± 7.5 μm, 13 ± 2.5 μm, 12 ± 3.5 μm). The measurement of pleural reaction by pathologic examinations was well-matched with the measurement by OCT images. This is the first study for measuring the thickness of pleural reactions using a biophotonic modality such as OCT. Our results showed that OCT can be useful for evaluating the early pleural reaction.

유연 기판 위 적층 필름의 굽힘 탄성계수 측정 (Measurement of Flexural Modulus of Lamination Layers on Flexible Substrates)

  • 이태익;김철규;김민성;김택수
    • 마이크로전자및패키징학회지
    • /
    • 제23권3호
    • /
    • pp.63-67
    • /
    • 2016
  • 본 논문에서는 폴리머 기반의 유연 기판 위 적층 된 다양한 필름의 굽힘 탄성계수의 간접 측정법을 소개한다. 패키징 기판의 다양한 적층 재료들의 탄성계수는 기계적으로 신뢰성 있는 전자기기 개발에 결정적이지만, 기판과 매우 견고히 접합하고 있는 적층 필름을 온전히 떼어 내어 자유지지형(free-standing) 시편을 만들기 어렵기 때문에 그 측정이 쉽지 않다. 이를 해결하기 위해 본 연구에서는 필름-기판의 복합체 시편에 대한 3점 굽힘을 진행하였고 시편 단면에 면적 변환법(area transformation rule)을 적용한 응력 해석을 수행하였다. 탄성계수를 알고 있는 기판에 대하여, 굽힘 시험으로 얻은 다층 시편의 강성으로부터 필름과 기판의 탄성계수 비를 계산하였으며, 전기 도금 구리 시편을 이용하여 양면 적층, 단면 적층의 두 가지 해석 모델이 실험 평가되었다. 또한 주요 절연체 적층 재료인 prepreg (PPG)와 dry film solder resist (DF SR)의 굽힘 탄성계수가 양면 적층 시편 형태로 측정 되었다. 결과로써 구리 110.3 GPa, PPG 22.3 GPa, DF SR 5.0 GPa이 낮은 측정 편차로 측정 됨으로써 본 측정법의 정밀도와 범용성을 검증하였다.