• Title/Summary/Keyword: Sectional measurement

Search Result 406, Processing Time 0.027 seconds

Inverse Reconstruction of Sectional Area in Nonuniform Ducts by Using the Acoustical Measurement (음파를 이용한 덕트 내 불균일 단면적의 역문제적 재구성)

  • 김회전;이정권
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.9-16
    • /
    • 2001
  • This paper deals with the inverse reconstruction of sectional area in nonuniform ducts by using the acoustical measurement. There have been many theoretical and experimental studies on the duct area reconstruction. In this research, the method using the impulse response function and area reconstruction algorithm was employed because of its mathematical and experimental simplicity. Based on the study results on the drawback of conventional impulse excitation method, a new measurement method is proposed, that uses the random noise source and the discrete inverse Fourier transform. It is found that the reconstruction errors of the present method is smaller than the conventional method. A random error analysis is performed in order to investigate the causes of reconstruction error and to clarify the applicable data range for area reconstruction.

  • PDF

A Study on the Measurement and the Analysis of Radar Cross Section of the Scaled Aircraft Model (축소형 항공기 모델의 레이다 단면적 분석 및 측정에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1055-1060
    • /
    • 2020
  • This study is a study on the analysis and measurement of the radar cross-sectional area of a miniature aircraft. Radar cross-sectional area for miniature aircraft in advance were analyzed using an electromagnetic analysis tool, and an actual miniature aircraft was manufactured and measured in an anechoic chamber. When measuring, the old model was used as reference data for RCS(radar cross section) characteristics and applied to the test result data of the actual reduced model. The measurement method improved the accuracy of the measurement by applying time gating to remove the influence on the components scattered inside the anechoic chamber. The RCS test results of the reduced model showed relatively high RCS characteristics in the microwave band, as the previous analysis results. In the future, we plan to utilize the method of RCS analysis and measurement for the target of the radar in the VHF(Very High Frequency)/UHF(Ultra High Frequency) band with a relatively large wavelength.

A Study on Unsteady Flow measurement using Laser Doppler Velocimeter in Curved Duct (곡관에서 laser유속계를 이용한 비정상유동 계측에 대한 연구)

  • 조병기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.81-89
    • /
    • 1996
  • In the present study, the unsteady in a square-selctional 180.deg. curved duct are experimentally investigated. The experimental study using air in a square-sectional 180.deg. curved duct is carried out to measure axial velocity distributions with data acquisition and processing system. In this system, Rotating Machinery Resolver(RMR) and PHASE Software are used to obtain the results of unsteady flows. In conclusion, the exact measurement of unsteady flow using LDV system depends upon uniformity of metreials, duct thickness, and scattered particles.

  • PDF

A Study on the Precise Measurement of the Performance in the Heating System (발열시스템 열적 성능의 정밀측정에 관한 연구)

  • 최창용;김홍건
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.6
    • /
    • pp.60-67
    • /
    • 2002
  • A precise measurement of field test was performed to estimate the thermal performance of the forced convection electric air heater by experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to estimate the thermal performance of the tested air heater effectively. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency was obtained accurately as an indication of the tested heating system performance.

On the Visualization of Three-Dimensional Vortical Structures in the Wake behind a Road Vehicle by PIV Measurements (PIV 측정을 통한 자동차 후류 3차원 와구조의 정량적 해석)

  • Lee Sukjong;Sung Jaeyong;Kim Jinseok;Kim Sungcho;Kim Jeongsoo;Choi Jongwook
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.58-63
    • /
    • 2005
  • Three-dimensional vortical structures in the wake behind a road vehicle has been visualized with the help of two-dimensional PIV measurement data. A three-dimensional velocity field has been reconstructed from several sectional measurement data in the x-y, y-z and z-x planes. Isovorticity surface observed by stacking only the sectional data in each plane, does not show the vortical structures within the recirculation region but represents only the strong shear flows. Thus, in the present study, the velocity component normal to the x-y plane is obtained by interpolating those velocities in the z-x plane. Then, a $\lambda_{2}$-definition which captures the local pressure minimum or vortex core, is applied to visualize the vortices in the recirculation region. The final results represent a successful configuration for the three-dimensional vortices.

  • PDF

Flow Characteristics of Developing Laminar Steady Flows in a Straight Duct Connected to a Square Curved Duct (곡관덕트에 연결된 정사각단면 직관덕트에서 증류정상유동의 유동장내 유동특성)

  • Sohn Hyun Chul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.545-553
    • /
    • 2005
  • In the present study, The characteristics of developing steady laminar flows of a straight duct connected to a $180^{\circ}$ curved duct were examined In the entrance region through experimental measurement. Flow characteristics such as shear stress distributions, pressure distributions and friction coefficient experimentally in a square cross-sectional straight duct by using the PIV system. For the PIV measurement by particles produced from mosquito coils particles. The experimental data were obtained at 9 points dividing the test sections by 400mm. Experimental results can be summarized as follows. Critical Reynolds number, $Re_{cr}$ which indicates transition from laminar steady flow to transition steady flow was 2,150. Shear stress per unit length on the wall was stronger than that in the fully developed flow region. This was attributed to the fact that shear stress and pressure loss in the curvature of a duct were increased. Pressure distributions were gradually decreased irrespective of Reynolds number In the whole test section. This trends were in a good agreement with the reference results. Pipe friction coefficient in the steady state flow region was calculate from method of least squares. The co-relationship between fiction coefficient and Reynolds number was established as follow; ${\lambda}=56/Re$.

A Study on the Mechanical Mechanism According to the Groove Shape of T-welded Joint (T-joint 용접부의 형상에 따른 역학적 메카니즘에 관한 연구)

  • 방한서;김종명
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.53-61
    • /
    • 1999
  • The use of thick plate in increasing in recent years due to the rapid expansion of chemical plants, nuclear plants, ships and other industrial plants. Welding is the most popular joining techniques employed in manufacturing industrial machineries and structures. Normally, Groove shapes are prepared according to appropriate rules and regulations such as KS, JIS, AWS, LR, DNV and etc. for various thicknesses of plate. However those groove angles tend to be too large. As a result of large groove angle, residual stress, deformation of material and strength reduction is obtained. Therefore, the reliability and safety of structures and machinery tend to be decreasing. Therefore, in this paper, theoretical as well as experimental study are carried out to find optimum groove shapes for T-welded joint of mild steel. The test specimen are made in same condition with simulation model. Welding residual stresses measurement by sectional cutting method. ⅰ) The mechanical difference for change the thickness of plate and groove angle are not appeared. ⅱ) In a mechanical point of view minimum preparation angle(40°) is more suitable than maximum groove angle(60℃). ⅲ) The measurement value and distribution of welding residual stresses are not effected largely by groove angle. It is mechanical restraint that mainly affect welding residual stresses distribution. In mechanical point of view minimum groove angle is more suitable than maximum groove angle. Therefore, it is appropriate to minimize the size of groove shape in strength and safety.

  • PDF

The effect of mandibular position on measurement in spiral tomography (나선형 단층방사선사진촬영에서 하악골 위치가 측정치에 미치는 영향)

  • Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.83-86
    • /
    • 2005
  • Purpose : To evaluate the effect of deviation of mandibular positioning, by changing the mandibular plane inclination, on the measured height and width of mandible in spiral conventional tomography. Materials and Methods : By means of the Scanora multifunctional unit, cross-sectional tomograms were taken from two human dried mandibles at the mandibular angulations: -15 degree, -10 degree, -5 degree, and 0 degree. Twenty-eight sites in two dried mandibles were imaged. One examiner measured the bone heights and widths at selected sites on the images and the actual bone heights were recorded. Results : The bone heights at the four mandibular inclinations overestimated real bone heights and the mean difference between actual heights and image heights on 0 degrees was the smallest (P<0.01). The bone widths on -15 degrees were narrowest and there were significant differences between bone widths measured at the four mandibular inclinations (P<0.001). We found statistically significant differences between both bone heights and widths as measured according to the mandibular plane angle for the posterior region (P<0.01). Conclusion : The use of different mandibular positioning may result in discrepancies in heights and widths when measured from the cross-sectional tomographic images. It is suggested that the mandibular positioning may play a significant role in the measurement of mandibular heights and widths.

  • PDF

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

Enhancement Technique of Discharge Measurement Accuracy Using Kalesto Based on Index Velocity Method in Mountain Stream, Jeju Island (지표유속법 기반 제주 산지형 하천 Kalesto 유량 정확도 향상 기법)

  • Kim, Dong-Su;Yang, Sung-Kee;Kim, Soo-Jeong;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.371-381
    • /
    • 2015
  • In the mountain streams in Jeju Island, strong turbulence and roughness usually made it nearly impossible to utilize most of intrusive instrumentation for streamflow discharge measurements. Instead, a non-intrusive fixed electro-magnetic wave surface velocimetry (fixed EWSV: Kalesto) became alternatively popular in many representative streams to measure stream discharge seamlessly. Currently, Kalesto has shown noteworthy performance with little loss in flood discharge measurements and also has successfully provided discharge for every minute. However, Kalesto has been operated to regard its measured one-point velocity as the representative mean velocity for the given cross-section. Therefore, it could be highly possible to potentially encompass discharge measurements errors. In this study, we analyzed the difference between such Kalesto discharge measurements and other alternative concurrent discharge measurements such as Acoustic Doppler Current Profiler (ADCP) and mobile EWSV which were able to measure velocity in multi-points in the cross-section. Consequently, Kalesto discharge deviated from ADCP discharge in amount of 48% for relatively low flow, and more than 20% difference for high flow compared with mobile EWSV discharge measurements. These results indicated that the one-point velocity measured by Kalesto should be used as a cross-sectional mean velocity, rather it should be accounted for as an index-velocity in conjunction with directly measured cross-sectional mean velocity by using more reliable instrumentations. After inducing Kalesto Discharge Correction Coefficient (KDCC) that actually means relationship between index velocity and cross-sectional mean velocity, the corrected discharge from Kalesto was significantly improved. Therefore, we found that index velocity method should be applied to obtain better accuracy of discharge measurement in case of Kalesto operation.