• 제목/요약/키워드: Secondary wastewater effluent

검색결과 87건 처리시간 0.018초

전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구 (Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

생물학적 고도처리공법에 적용된 두 형태의 장방형 이차침전지 성능 파악 (Evaluating Two Types of Rectangular Secondary Clarifier Performance at Biological Nutrient Removal Facilities)

  • 이병희
    • 상하수도학회지
    • /
    • 제27권5호
    • /
    • pp.561-570
    • /
    • 2013
  • There are two types of rectangular secondary clarifier at biological nutrient removal (BNR) facility to settle MLSS; conventional activated sludge secondary clarifier and Gould Type I clarifier. In this study, the performances of two types at respective biological nutrient removal facility are compared using weekly operational data. Surface Overflow Rate (SOR), Surface Loading Rate (SLR), Sludge Volume Index (SVI), secondary effluent SS concentration are studied. It has found that Gould Type I has 3.5 times less average secondary effluent SS concentration that is 2.4 mg/L than that of conventional activated sludge secondary clarifier. Both SOR and SLR have shown little effect on secondary effluent SS concentrations at Gould Type I clarifier in contrary that SOR affects the secondary effluent SS concentrations at conventional activated sludge rectangular secondary clarifier. From this study, it is recommended that Gould Type I must be considered for secondary clarifier when BNR plant is designed.

CFD와 PIV test를 통한 장방형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of a rectangular secondary clarifier using CFD and PIV test)

  • 최영균;배강형;윤정환
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.41-50
    • /
    • 2010
  • The influent and effluent baffle configurations seriously affect the hydraulic characteristics of the secondary clarifier in wastewater treatment plant. In this study, those baffle configurations were optimized by computational fluid dynamics(CFD) analysis and particle image velocity(PIV) test in order to obtain uniform flow in inlet region and to minimize upflow velocity in outlet region of the secondary clarifier. Theoretical analysis using CFD showed that more uniform flow could be accomplished when the influent baffle was located closely to the inlet opening. Effects of effluent baffle configuration on the upflow velocity in the outlet region of the secondary clarifier were analyzed with four types of effluent baffles which are widely adopted for secondary clarifier design. From the CFD analysis, McKinney baffle(EB-2) was estimated to be the most effective for restraining the upflow velocity in the outlet region and these trends were identified by PIV tests. In addition, the McKinney baffle showed the most uniform overflow velocity distribution around the weir.

DOF(Dissolved Ozone Flotation) 시스템을 이용한 하수처리장 방류수의 고도처리에 대한 연구 (Advanced Secondary Wastewater Treatment Using the DOF (Dissolved Ozone Flotation) System)

  • 이병호;김상희
    • 상하수도학회지
    • /
    • 제19권6호
    • /
    • pp.767-774
    • /
    • 2005
  • The DOF (Dissolved Ozone Flotation) system was used to treat the effluent of the secondary wastewater treatment plant. The DOF system uses ozone instead of air, while DAF (Dissolved Air Flotation) uses air. Moreover, since the solubility of ozone is higher than air, the DOF system produces larger volume of micro-bubbles than the DAF system does. Thus, the DOF system performs better than the DAF system in floating ability. The DOF system could remove 70% of turbidity to an average of 0.59NTU in effluent from 2.31NTU in influent. The removal efficiency of absorbance measured with UV-254 in the effluent of the DOF system was 63%, while only 19% was removed by the DAF system. the DOF system removed 84% of the color from 25~26CU to 4CU, while DAF system removed 42% of the color to 15 CU. The CODMn removal efficiency of the DOF system was 34%, 6.8mg/l of effluent $COD_{Mn}$ concentratin, while it was 20%, 8.3mg/L of effluent $COD_{Mn}$ concentratin, to use the DAF system. Microbial bacteria such as coliform bacteria, and heterotrophic bacteria were removed over 99% by the DOF system, and 42~45% by the DAF system. That is, Microbial bacteria were almost completely destroyed by the DOF system. To sum up with, the DOF system was found to be very effective to treat effluent of the wastewater treatment plant.

하수처리장 2차 처리수의 고효율 인 제거를 위한 응집제 개선 (Improved Coagulant for High Efficiency Phosphorus Removal in Secondary Effluent of Waste Water Treatment Plant)

  • 최정승;이병하;김기팔;백대진
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.683-690
    • /
    • 2016
  • Modified coagulants were investigated for the removal of phosphorus from secondary effluent of wastewater treatment. The modified coagulants were prepared by mixing alkali earth metal ions such as calcium and magnesium. The basicity of a coagulant influenced on the removal of phosphorus, and coagulants with basicity of 5.9% showed a better removal of total phosphorus than that of 38.5%. Also, coagulants with alkali earth metals enhanced the performance of coagulation by 10% and resulted in 67.1% for total phosphorus removal. Moreover, the removal of suspended solids and chemical oxygen demand was improved using coagulants with low basicity and earth metal ions. Results of this study demonstrated that the use of coagulants with low basicity, and calcium and magnesium ions is recommended to improve wastewater effluent quality.

CFD와 PIV test를 통한 원형 2차침전지 유입 및 유출배플 형상 최적화 (Optimization of influent and effluent baffle configuration of circular secondary clarifier using CFD and PIV test)

  • 최영균;배강형
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.73-81
    • /
    • 2014
  • One-dimensional flux theory (1DFT) is conventionally used for design of secondary clarifier of wastewater treatment plant. However, the 1DFT cannot describe turbulence, density current, shape parameters of the clarifier. In this study, we optimized the configurations of influent guide baffle and effluent baffle through the simulation using computational fluid dynamics (CFD) and its verification by particle image velocity (PIV) test. The energy dissipating inlet (EDI) without influent guide baffle ($0^{\circ}$) showed the best efficiency for minimizing downward velocity under the center well of the clarifier. The lowest velocity distribution around the effluent weir region could be obtained with the McKinney baffle (EB-2). The performances of the influent and effluent baffles were clearly verified by PIV test results.

Genotoxic and Neurotoxic Potential in Marine Fishes Exposed to Sewage Effluent from a Wastewater Treatment Plant

  • Park, So-Yun;Kim, So-Jung;Rhee, Yong;Yum, Seung-Shic;Kwon, Tae-Dong;Lee, Taek-Kyun
    • Molecular & Cellular Toxicology
    • /
    • 제5권3호
    • /
    • pp.265-271
    • /
    • 2009
  • Concentrations of industrial, agricultural and natural chemicals have been increasing in secondary effluents without their combined sub-lethal effects having been elucidated. In this study, two assays (the comet and acetylcholinesterase assays) were combined to evaluate the genotoxic and neurotoxic effects of effluent from the Noksan wastewater treatment plant (WWTP) on two local marine fish species (flounder and sea eel). The fish were exposed to WWTP secondary effluent that had been diluted with filtered seawater to final concentrations of 1%, 10% and 50%. Analysis of fish samples collected 3 and 5 days after exposure showed that DNA damage occurred in flounder exposed to 50% effluent and in sea eels exposed to 10% or 50% effluent. Furthermore, it was found that acetylcholinesterase (EC:3.1.1.7, AChE) activity decreased in both species when exposed to 10% effluent, indicating the presence of large amounts of genotoxic and neurotoxic chemicals in the effluent. Our results indicate that the comet and AChE assays are promising tools for biomonitoring of secondary effluents.

DOF(Dissolved Ozone Flotation)를 이용한 부유물질과 총인의 제거와 소득의 동시효과에 관한 연구 (Disinfection and Removal of SS and T-P Using DOF (Dissolved Ozone Flotation))

  • 이병호;김성혁;이상배;김미정
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.215-221
    • /
    • 2004
  • Effluent of wastewater treatment plant is to be disinfected to protect drinking water sources. DOF (Dissolved Ozone Flotation) was developed to meet this purpose. DOF was developed by combining DAF system with ozone. DAF system has good floating power with numerous microbubbles, and ozone has strong oxidation capability. And DOF system has good floating power and strong oxidation capability simultaneously. When DOF was applied to secondary wastewater effluent, color of 11CU in raw water which was secondary effluent was reduced to 1CU by the DOF system. Removal rate of other water quality parameters treated by DOF were also higher than that by DAF, which were proved the strength of oxidation capability of ozone. When ozone concentration of 3.3mg/l were applied in DOF system, general aerobic bacteria were reduced to 5CFU/ml from TNTC (Too many Numbers To Count). With the same ozone concentration, total coliform were not detected at all. These figures are under the numbers of drinking water regulation. These microbes were the target parameters of DOF. It was proved that DOF was very effective in disinfection of wastewater treatment plant effluent as well as in removal of color, turbidity, and T-P.

정밀여과법 하수재이용 공정에서 오존의 전처리 효과에 관한 연구 (Effect of Ozonation in Microfiltration Membrane for Wastewater Reuse)

  • 문성용;안세혁;이상협;박종훈;홍석원;최용수
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.535-543
    • /
    • 2006
  • The Ozone oxidation process was applied to increase the efficiency of reuse process when treating the secondary effluent by the membrane system. This paper focus on decreasing efficiency of membrane fouling, because of membrane fouling reduction by ozone and evaluation of application of the ozone oxidation. The feed water was secondary effluent from BNR process. The result shows that the ozone pretreatment can reduce membrane fouling effectively. Also, the improvement of treated water quality was obvious. The reduction of the membrane fouling led decrease of following pollutant and increase of lnner adsorptive ability of hydrophilic organic matter and decrease of molecular weight. MF membrane process alone can meet the domestic reuse water standards. And ozone pretreatment process also can increase the removal rates of turbidity, COD, nitrogen, and color.

우리나라 하수처리장 방류수 수질현황 및 특성 (Survey of the Secondary Effluents from Municipal Wastewater Treatment Plants in Korea)

  • 김영철;안익성;강민기
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.158-168
    • /
    • 2005
  • In this study, the discharging effluents from have been 9 municipal wastewater treatment plants surveyed for 1 year-period. Statistics including probability distribution, cumulative occurrence concentration and other statistical parameters were presented. In addition, treatment performance and its stability were also discussed. Most of the plants, have an operational problem of high soluble organic content in the secondary effluent which may be associated with the integrated treatment of human and livestock manures. Nitrogen concentration in the effluents were usually higher during the period of summer and winter. It was found that this is mainly due to lack of the proper C/N ratio during the summer, or/and the effects of low temperature and less dilution by dry weather during the winter. Phosphorus concentration is sharply increased in June. Discussion with plant operators told that it is due to the dissolution of phosphate from the sludge accumulated in the primary settling tanks from the early spring to june. During this period, usually, sludge treatment line is highly overloaded with flush-outs of the sediments also stored in the bottom of combined sewer due to the low flow during winter season. Most of the plants can meet new effluent discharge limits of the nitrogen and phosphorus, and total coliform without further treatment.