• Title/Summary/Keyword: Secondary barrier

Search Result 110, Processing Time 0.022 seconds

Evaluation of Mechanical Performance Considering Prolonged Length of Glass Fiber-Reinforced Composite on Structure Weakness by Thermal Stress at Secondary Barrier in Cryogenic Liquified Gas Storage (극저온 액화가스 화물창 2차방벽 구조 열 응력 취약 부 Prolonged 길이 고려 유리섬유 강화 복합재 기계적 물성 평가)

  • Yeon-Jae Jeong;Hee-Tae Kim;Jeong-Dae Kim;Jeong-Hyun Kim;Seul-Kee Kim;Jae-Myung Lee
    • Composites Research
    • /
    • v.36 no.4
    • /
    • pp.246-252
    • /
    • 2023
  • A secondary barrier made of glass fiber reinforced composites has been installed infinitely using automatic bonding machine(ABM) in membrane type LNG cargo containment system (CCS). At the same time, significant thermal stress due to cryogenic heat shrinkage has occurred in the composite on the non-bonding area between the adhesive fixation at both ends. There have been studies from the perspective of structural safety evaluation taking this into account, but none that have analyzed mechanical property taking an prolonged length into account. In this study, 2-parameter Weibull distribution statistical analysis was used to standardize reliable mechanical property for actual length, taking into account the composite's brittle fracture of ceramic material with wide fracture strength dispersion. Related experimental data were obtained by performing uniaxial tensile tests at specific temperatures below cryogenic condition considering LNG environment. As a result, the mechanical strength increased about 1.5 times compared to -20℃ at -70℃ and initial non-linear behavior of fiber stretched was suppressed. As the temperature decreased until the cryogenic, the mechanical strength continued to increase due to cold brittleness. The suggested mechanical property in this study would be employed to secure reliable analysis support material property when assessing the safety of secondary barrier's structures.

Current status of interprofessional education learning activities in wards provided by tertiary hospitals and secondary general hospitals and barriers

  • Kang, Joonsung;Sin, Hye Yeon
    • Korean Journal of Clinical Pharmacy
    • /
    • v.32 no.2
    • /
    • pp.106-115
    • /
    • 2022
  • Background: The World Health Organization (WHO) has focused on the need for interprofessional education (IPE) to improve interprofessional collaboration competency and patient health outcomes. Accordingly, most European and North American medical colleges have established IPE for students. However, IPE learning activity in medical wards for the clinical experience of pharmacy students has not been fully reviewed in Korea. Therefore, this study aims to examine the current status of IPE learning activities in wards at tertiary and secondary hospitals in order to identify ways to improve the program. Methods: The official document of cooperation consists of six self-administered questions regarding IPE learning activities in wards. The preceptor's response in each hospital was evaluated. Results: Of the 22 hospitals, 9 tertiary hospitals and 12 secondary general hospitals responded. For the introductory pharmacy practice experience (IPPE), participating in intensive care (IC) was provided at one secondary general hospital (8.3%) and no tertiary hospital. Ward rounds with medical staff members were provided at two tertiary hospitals (22.2%) and one (8.3%) secondary general hospital. A major barrier to executing IPE was lack of rewards and incentives for the faculty and preceptors who participated in the program. Conclusion: In both tertiary hospitals and secondary general hospitals, pharmacy students have limited exposure to IPE learning activities in wards at hospital, and IPPE at most hospitals was carried out in pharmacy settings only. This study suggests that it is necessary for the hospitals to improve and support IPE learning activities in wards in order to improve learners' competency.

Actively Controlled Sound Field of Upper Sections Attached to Noise Barriers (방음벽 상단의 음장에 관한 능동제어)

  • Koh, Hyo-In;Lee, Chan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.8 s.101
    • /
    • pp.891-896
    • /
    • 2005
  • On the basis of theoretical studies on the effect of the cylinders attached to semi-infinite screens, the tangential sound power-transport parallel to the surface of the attached cylinder is minimized by means of a secondary sound field, which is generated from a part of the attached cylinder. The numerical study shows the possibility of deflecting the incident sound by minimizing the sound field of the upper sections. The acoustical shadow region was more pronounced in both near- and far-field compared to the passive case with rigid surface, i.e. without active control. For a relatively wide frequency range it was possible to enhance shielding effects only with few secondary sources and error microphones. In this paper effects of control parameters on the actively controlled sound field near the top edge of noise barriers are studied. Results of numerical study and model measurements are shown and discussed.

Comparative studies of adaptive filters for active noise barriers (능동방음벽을 위한 적응필터 비교연구)

  • Choi, Jeong-Il;Park, Kyung-Won;Cho, Hyun-Gi;Nam, Hyun-Do;Shin, Eun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.301-306
    • /
    • 2011
  • In this paper, active noise barriers for attenuation of road noise are proposed. multi-channel audio systems, DAQ part and high performance DSP H/W were designed. Active noise control firmware programs were implemented for multi-channel off-line/on-line estimation methods for secondary path transfer functions and FIR/IIR filter structure are used main noise control algorithms. To evaluate performance of proposed systems, the experiments were performed in an active noise barrier test bed for various noise cases.

  • PDF

Actively controlled sound field of upper sections attached to noise harriers (방음벽 상단 소음의 회절에 관한 능동제어)

  • Koh, Hyo-In;Moser, Michael
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.482-485
    • /
    • 2004
  • On the basis of theoretical studies on the effect of the cylinders attached to semi-infinite screens, the tangential sound power-transport parallel to the surface of the attached cylinder is minimized by means of a secondary sound field, which is generated from a part of the attached cylinder. The numerical study shows the possibility of deflecting the incident sound by minimizing the acoustic surface impedance of the upper sections. The acoustical shadow region was more pronounced in both near- and far-field compared to the passive case with rigid surface, i.e. without active control. For a relatively wide frequency range it was possible to enhance shielding effects only with few secondary sources and error microphones. In this paper effects of some control parameters on the actively controlled sound field near the top edge of noise barriers are studied. Results of numerical study and model measurements are shown and discussed.

  • PDF

Dependence of Drain Induced Barrier Lowering for Ratio of Channel Length vs. Thickness of Asymmetric Double Gate MOSFET (비대칭 DGMOSFET에서 채널길이와 두께 비에 따른 DIBL 의존성 분석)

  • Jung, Hakkee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.6
    • /
    • pp.1399-1404
    • /
    • 2015
  • This paper analyzed the phenomenon of drain induced barrier lowering(DIBL) for the ratio of channel length vs. thickness of asymmetric double gate(DG) MOSFET. DIBL, the important secondary effect, is occurred for short channel MOSFET in which drain voltage influences on potential barrier height of source, and significantly affects on transistor characteristics such as threshold voltage movement. The series potential distribution is derived from Poisson's equation to analyze DIBL, and threshold voltage is defined by top gate voltage of asymmetric DGMOSFET in case the off current is 10-7 A/m. Since asymmetric DGMOSFET has the advantage that channel length and channel thickness can significantly minimize, and short channel effects reduce, DIBL is investigated for the ratio of channel length vs. thickness in this study. As a results, DIBL is greatly influenced by the ratio of channel length vs. thickness. We also know DIBL is greatly changed for bottom gate voltage, top/bottom gate oxide thickness and channel doping concentration.

Development of Plasma Assisted ALD equipment and electrical characteristic of TaN thin film deposited PAALD method (Plasma Assisted ALD 장비 계발과 PAALD법으로 증착 된 TaN 박막의 전기적 특성)

  • Do Kwan-Woo;kim Kyoung-Min;Yang Chung-Mo;Park Seong-Guen;Na Kyoung-Il;Lee Jung-Hee;Lee Jong-Hyun
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.139-145
    • /
    • 2005
  • In the study, in order to deposit TaN thin film using diffusion barrier and bottom electrode we made the Plasma Assisted ALD equipment and confirmed the electrical characteristic of TaN thin films deposited PAALD method, PAALD equipment depositing TaN thin film using PEMAT(pentakis(ethylmethlyamlno) tantalum) Precursor and $NH_3$ reaction gas is aware that TaN thin film deposited of high density and amorphous phase with XRD measurement The degree of diffusion and react ion taking place in Cu/TaN(deposited using 150 W PAALD)/$SiO_2$/Si systems with increasing annealing temperature was estimated from MOS capacitor property and the $SiO_2(600\;\AA)$/Si system surface analysis by C-V measurement and secondary ion material spectrometer(SIMS) after Cu/TaN/$SiO_2(400\;\AA)$ system etching. TaN thin film deposited PAALD method diffusion barrier have a good diffusion barrier property up to $500^{\circ}C$.

  • PDF

Development of Plasma Assisted ALD equipment and Electrical Characteristic of TaN thin film deposited PAALD method (Plasma Assisted ALD 장비 계발과 PAALD법으로 증착 된 TaN 박막의 전기적 특성)

  • Do Kwan Woo;Kim Kyoung Min;Yang Chung Mo;Park Seong Guen;Na Kyoung Il;Lee Jung Hee;Lee Jong Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.39-43
    • /
    • 2005
  • In the study, in order to deposit TaN thin film for diffusion barrier and bottom electrode we made the Plasma Assisted ALD equipment and confirmed the electrical characteristics of TaN thin films grown PAALD method. Plasma Assisted ALD equipment depositing TaN thin film using PEMAT(pentakis(ethylmethlyamino) tantalum) precursor and NH3 reaction gas is shown that TaN thin film deposited high density and amorphous phase with XRD measurement. The degree of diffusion and reaction taking place in Cu/TaN (deposited using 150W PAALD)/$SiO_{2}$/Si systems with increasing annealing temperature was estimated for MOS capacitor property and the $SiO_{2}$, (600${\AA}$)/Si system surface analysis by C-V measurement and secondary ion material spectrometer (SIMS) after Cu/TaN/$SiO_{2}$ (400 ${\AA}$) layer etching. TaN thin film deposited PAALD method diffusion barrier have a good diffusion barrier property up to 500$^{\circ}C$.

  • PDF

Li:Al cathode layer and its influence on interfacial energy level and efficiency in polymer-based photovoltaics

  • Park, Sun-Mi;Jeon, Ji-Hye;Park, O-Ok;Kim, Jeong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.72-72
    • /
    • 2010
  • Recent development of organic solar cell approaches the level of 8% power conversion efficiency by the introduction of new materials, improved material engineering, and more sophisticated device structures. As for interface engineering, various interlayer materials such as LiF, CaO, NaF, and KF have been utilized between Al electrode and active layer. Those materials lower the work function of cathode and interface barrier, protect the active layer, enhance charge collection efficiency, and induce active layer doping. However, the addition of another step of thin layer deposition could be a little complicated. Thus, on a typical solar cell structure of Al/P3HT:PCBM/PEDOT:PSS/ITO glass, we used Li:Al alloy electrode instead of Al to render a simple process. J-V measurement under dark and light illumination on the polymer solar cell using Li:Al cathode shows the improvement in electric properties such as decrease in leakage current and series resistance, and increase in circuit current density. This effective charge collection and electron transport correspond to lowered energy barrier for electron transport at the interface, which is measured by ultraviolet photoelectron spectroscopy. Indeed, through the measurement of secondary ion mass spectroscopy, the Li atoms turn out to be located mainly at the interface between polymer and Al metal. In addition, the chemical reaction between polymer and metal electrodes are measured by X-ray photoelectron spectroscopy.

  • PDF

Evaluation of Reduction in Reflection Sound bound from a Shaped Noise Barrier Panel (형상 방음벽 패널의 반사음 저감효과 평가)

  • Lee, Jaiyeop;Kim, Ilho
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.19-24
    • /
    • 2015
  • PURPOSES : The noise, which is typically generated by fast moving vehicles, can be intercepted by installing a noise barrier with a soundproof panel. However, reflections from the panels cause secondary noise, and hence lower the effectiveness of the panels. In this study, the reduction of reflection noise by considering the shape, especially zigzag one, of the soundproof panel have been evaluated. METHODS : The simulation model used in this study was Nord2000, which simulates real-road situations effectively. Based on the simulation results, the joining angle of $133^{\circ}$ with the pattern width (a) equal to 2 m and the projection height (b) equal to 0.5 m was adapted in the zigzag shape as the best profit designing factors. RESULTS: The measuring results at middle height, 15 m showed reduction at all points except the point with average -1.6 dB. At a greater height of 30 m, 2 points showed reduction. A real-sized facility was constructed to investigate the reflected sound from a zigzag shaped panel up to the height of 5 m. CONCLUSIONS: The reduction effects were detected in all the receive points in the range of 2-6 m distances and 1-5 m heights comparing the plane panel. Compared to plane panel, the noises are reduced at an average of 2.4 dBA.