• 제목/요약/키워드: Secondary System

검색결과 3,328건 처리시간 0.028초

LNGC 2차 방벽에 적용된 Aramid 섬유의 Weibull 통계 분석을 이용한 피로특성 평가 (Estimation of Fatigue Characteristics Using Weibull Statistical Analysis with Aramid Fiber on LNGC Secondary Barrier)

  • 박진형;오동진;김민규;김명현
    • 대한조선학회논문집
    • /
    • 제54권5호
    • /
    • pp.415-420
    • /
    • 2017
  • Insulation systems in Liquefied Natural Gas Carriers (LNGC) are vulnerable to sloshing impact and fatigue loads because of waves. If gas leaks into the primary barrier, the Flexible Secondary Barrier (FSB) prevents the leakage of gas in this system. Fatigue strength of the FSB largely depends on the behavior of composite materials. In this study, a new system is applied to the FSB using aramid fiber to improve the fatigue strength of the secondary barrier, with the intention of replacing conventional E-glass fibers. The manufacturing method involved varying the ratio of the aramid fiber to the E-glass fiber for optimum design of the FSB. The fatigue tests results of the secondary barrier using aramid fiber were superior to that using E-glass fiber. The statistical analysis is performed to obtain the fatigue test results and estimate the probability of failure as well as the design guideline of LNGC secondary barriers.

Characteristics of the magnetic flux-offset type FCL by switching component

  • Jung, Byung-Ik;Choi, Hyo-Sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.18-20
    • /
    • 2016
  • The study of superconducting fault current limiter (SFCL) is continuously being studied as a countermeasure for reducing fault-current in the power system. When the fault occurred in the power system, the fault-current was limited by the generated impedance of SFCLs. The operational characteristics of the flux-offset type SFCL according to turn ratios between the primary and the secondary winding of a reactor were compared in this study. We connected the secondary core to a superconductor and a SCR switch in series in the suggested structure. The fault current in the primary and the secondary winding of the reactor and the voltage of the superconductor on the secondary were measured and compared. The results showed that the fault current in the load line was the lowest and the voltage applied at both ends of the superconductor was also low when the secondary winding of the reactor had lower turn ratio than the primary. It was confirmed based on these results that the turn ratio of the secondary winding of the reactor must be designed to be lower than that of the primary winding to reduce the burden of the superconductor and to lower the fault current. Also, the suggested structure could increase the duration of the limited current by limiting the continuous current after the first half cycle from the fault with the fault current limiter.

Queuing Analysis of Opportunistic in Network Selection for Secondary Users in Cognitive Radio Systems

  • Tuan, Le Ahn;Hong, Choong-Seon
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2012년도 한국컴퓨터종합학술대회논문집 Vol.39 No.1(D)
    • /
    • pp.265-267
    • /
    • 2012
  • This paper analyzes network selection issues of secondary users (SUs) in Cooperative Cognitive Radio Networks (CRNs) by utilizing Queuing Model. Coordinating with Handover Cost-Based Network selection, this paper also addresses an opportunity for the secondary users (SUs) to enhance QoS as well as economics efficiency. In this paper, network selection of SUs is the optimal association between Overall System Time Minimization Problem evaluation of Secondary Connection (SC) and Handover Cost-Based Network selection. This will be illustrated by simulation results.

The secondary excited induction generator in random wave input system

  • Kim, Moon-Hwan
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.209-214
    • /
    • 2009
  • The employment of the induction generator is preferable in the natural energy utilization by the minimum maintenance and the mechanical robustness, Another merit is also expected when it is connected to the power network system, because constant-voltage and constant frequency (CVCF) power generation is easily realized in spite of the variation of the rotor speed. However the induction generator needs much amount of the reactive power that reduces power factor in the primary side. The improvement of power factor in the primary side requires large VAR compensator, this point is solved, the merit of the induction machine as a main generator will become more established. This paper proposes a novel approach where the secondary is controlled by a PWM inverter not only to get CVCF power but also to improve the primary power factor. Basically the inverter is controlled so that the field current is supplied from the secondary side in this approach. The required capacity of the inverter is small, because only the slip power is controlled in the secondary side. In the experimental system where the sea wave torque simulator is used, the power factor is well improved by the microcomputer controlled PWM inverter.

중등학교 환경과 교사 임용고사 제도의 문제점과 개선방안 (Current Status and Ways for Improvement of the Examination System for the Employment of Environmental Education Teachers in Secondary Schools)

  • 최돈형
    • 한국환경교육학회지:환경교육
    • /
    • 제14권1호
    • /
    • pp.66-80
    • /
    • 2001
  • In this study, the current status and the desirable ways for improvement of the examination system for the employment of the environmental education teachers in the secondary school were investigated. For the study, first, problems and reasons, and the counterplan of policy on the teacher connected directly with the examination employing secondary school teachers through exploration of the related literatures were analyzed; second, it was identified that the essential quality which environmental education teachers should have ready; third, the curriculum of environmental education teacher training universities and the seventh environmental curriculum were examined to provide a basis of discussion on the principle of setting questions for the employment of environmental education teachers; fourth, the number of recruitment, the number of examinee, the principle of setting questions, the composition of questions, and the distribution of scores of the examination which were carried out in the school year 2000 and 2001 were compared and analyzed; finally, the basis of the above analyses, recommendations to consider the examination system for the employment of environmental education teachers in the secondary school were presented as follows: first, the team managing the examination for the employment should reflect the aims and special contents of environmental education to discuss and decide the principle of setting questions on the environmental course; second, the proportion of subject matter education in the examination for environmental education teachers should be increased; third, the validity of questions for the examination should be clarified and the difficulty level of the questions should be low.

  • PDF

광섬유 대량생산시스템 이중 액상코팅공정의 점성소산 및 공정인자 영향성 해석연구 (Parametric Investigation on Double Layer Liquid Coating Process with Viscous Dissipation in Optical Fiber Mass Manufacturing System)

  • 김경진;박중윤
    • 반도체디스플레이기술학회지
    • /
    • 제17권4호
    • /
    • pp.80-85
    • /
    • 2018
  • The present investigation on optical fiber mass manufacturing features the computational modeling and simulation on a double layer liquid coating process on glass fiber surface. The computational model employs a simplified geometry of typical fiber coating system which consists of primary and secondary coating dies along with secondary coating cup. The viscous dissipation in coating flow is incorporated into the double layer coating process simulations. Heavy temperature dependence of coating liquid viscosity is also considered in the model. The computational results found that the effects of viscous dissipation on both primary and secondary coating layer thicknesses are highly significant at higher drawing speed. Several important coating process parameters such as supply temperature and pressure of primary and secondary coating liquids are investigated and discussed in order to appreciate how those parameters affect the double layer coating layer thickness on fast moving glass fiber.

하나로 2 차 냉각탑의 공장분해수리 (Cooling Tower Overhaul of Secondary Cooling System in HANARO)

  • 박용철;이용섭;김양곤;정환성;임인철
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2714-2719
    • /
    • 2007
  • HANARO, an open-tank-in-pool type research reactor of 30 MWth power in Korea, has been operating normally since its initial criticality in February, 1995. For the last about ten years, A cooling tower of a secondary cooling system has been operated normally in HANARO. Last year, the cooling tower has been overhauled for preservative maintenance including fills, eliminators, wood support, water distribution system, motors, driving shafts, gear reducers, basements, blades and etc. This paper describes the results of the overhaul. As results, it is confirmed that the cooling tower maintains a good operability through a filed test. And a cooling capability will be tested when a wet bulb temperature is maintained about 28 $^{\circ}C$ in summer and the reactor is operated with the full power.

  • PDF

Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant

  • Heo, Taehoon;Cho, Seung Hyun
    • Nuclear Engineering and Technology
    • /
    • 제48권6호
    • /
    • pp.1404-1411
    • /
    • 2016
  • Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.

제한된 반응시간에서 과도한 정신부하작업의 수행도에 관한 연구 (Performance of Excessive Mental-workload under Limited Reaction Time)

  • 오영진;김제숭
    • 한국산업정보학회논문지
    • /
    • 제10권2호
    • /
    • pp.21-25
    • /
    • 2005
  • 본 연구는 인간의 정신부하작업중 반응시간이 제한된 긴급상황에서 시스템이 비정상적인 상태로 변화할 경우 인간의 수행도 특성을 살펴보고 이를 보조할 수 있는 보조장치의 설계에 도움을 주는 기준 안을 제시하고자 한다. 긴급상황에서 최우선시 되는 수행도는 반응시간보다는 시스템을 성공적으로 제어하여 비극적인 재해를 방지하는 일이다. 그러므로 여러 작업 수행도들 중에서 제어에 실패하게 되는 요인의 영향도를 알아내는 것이 중요하다. 실험결과 인간의 반응은 극히 제한된 짧은 반응시간내의 단일작업에서의 수행도는 시스템의 전체 영향도를 제대로 반영하지 못함을 알 수 있었다. 이럴 경우 부수작업을 부여했을 때 시스템의 변화 요인의 영향도를 더욱 잘 나타내는 것임을 유도하였다. 그러므로 시스템의 상황이 비 정상적인 상태로 진행될 경우, 특히 이러한 상황에서 반응해야 할 시간이 제한적일 경우 수행도 측정에는 다양한 형태의 부수작업을 개발하고 이를 이용한 측정이 더욱 효율이 있다는 점을 제시한다. 이러한 실험의 결과를 유추해보면 안전장치 기기의 설계를 위해서는 운용되는 상황에 맞는 측정방법이 개발되어야 긴급 상황의 수행도를 측정할 수 있다.

  • PDF

상업용 소각로 연소실 성능예측을 위한 수치해석 연구 (Numerical Analysis for the Performance Prediction of Combustion Chamber of Commercial Incinerator)

  • 이진욱;박병수;윤용승;서정대;허일상
    • 한국연소학회지
    • /
    • 제4권1호
    • /
    • pp.141-153
    • /
    • 1999
  • Numerical analysis for the combustion flow in the combustion chamber of incineration system has been carried out in order to acquire the basic design capability of incineration system. Established mathematical model was applied to the performance prediction of the pre-designed combustion chamber of commercial plant. Especially, combustion characteristics and the variation of flow pattern have been deeply discussed in accordance with secondary air injection. Secondary air injection was effective for the turbulent mixing between air and carbon monoxide/volatile matter resulting in considerably reduced CO content at the exit. Secondary air injection was found to be one of the key design parameters because the size of recirculation zone could be changed with the variation of injection characteristics.

  • PDF