• Title/Summary/Keyword: Secondary Accident

Search Result 178, Processing Time 0.025 seconds

A Pilot Study on Environmental Factors Contributing to Childhood Home Slip-Down Injuries (가정 내 낙상으로 인한 아동 손상의 유발 환경 인자에 관한 예비연구)

  • Ryu, Jeong-Min;Seo, Min Hoo;Kim, Won-Young;Kim, Won;Lim, Kyoung-Soo
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate environmental factors contributing to childhood home slip-down injuries. Methods: Among a total of 2,812 injured children in our Customer Injury Surveillance System (CISS), we performed a prospective study on 262 children with home slip-down injuries who visited the pediatric emergency department of Asan Medical Center between March 2008 and February 2009. We made a frequency analysis on parameters such as activities just before the accident, the presence of any obstacles or lubricant materials, specific home place in the home where the injuries occurred, flooring materials on which the slip-down happened, additional objects hit after slip down, the site and kind of injury, the duration of therapy, and the disposition. Results: Walking was the most common activity just before the injury. Because rooms and bathrooms were most common places in the home for slip down injuries, laminated papers/ vinyl floor coverings and tiles were the most common flooring materials used in the places where the injuries occured. Most commonly, no obstacles caused the children to slip down, but the furniture, stairs, doorsills, wetness, or soapy fluid followed after that. Over half of the children who slipped (58%) also collided with other than the floor itself after the slip-down, most common objects hit were the edges of the furniture, and doorsills, followed by stairways. The head and neck were the most commonly injured sites, and a laceration was the most common kind of injury. Most children needed less than 1 week of therapy, only 4 children (1.53%) admitted. There were no mortalities. Conclusion: The environmental factors contributing to slip-down injuries were the bathroom, laminated papers/vinyl floors, the furniture, stairs, doorsills, and wetness or soapy fluid. Especially, the furniture, stairs, and doorsills can be both primary obstacles and secondary collision objects. For the safety of our children, we must consider these factors on housing, when decorating or remodeling our house.

A Study on Design Standards of a median strip in City considering Traffic Safety (교통안전을 고려한 도심형 중앙분리대 설치기준 마련에 관한 연구)

  • Kim, Jong-Min;Kim, Jang-Wook;Noh, Kwan-Sub;Kim, Kyung-Tae
    • International Journal of Highway Engineering
    • /
    • v.14 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • The Government is implementing the safety measures for pedestrian in living zone to decrease the traffic accident casualties in half. It is urgently to study the guideline because it contains to make the guideline of a median strip in City to prevent the violation of central line and jaywalking on the main contents. So, this study analyzed the pedestrian accidents and the violation of central line, and studied the type of a median strip, the installation guideline through studying the minimum crossing. Consequently, this study found out that a median strip which revised the attention inducement stick to decrease jaywalking could not have the strong prevention function of a crash barrier, so if it happens separation after the collision between vehicles, it induced the secondary accidents, and could take negative effects on traffic safety. In consideration of driving safety, this study analyzed that if it installs a median stirp, it has to ensure one meter, and such a thing could prevent the separation of lane or damage of facilities. However, if it is hard to ensure the space because of narrow road width, it could install a median strip in case of installing the road surface mark 0.5m. And the installation of the attention inducement stick or a median strip on the central line could be possible to induce the violation of central line, thus it is desirable not to install only anythings but also raised pavement markers.

Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas (수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발)

  • Choi, In Young;Baik, Sung Hoon;Park, Nak Gyu;Kang, Hee Young;Kim, Jin Ho;Lee, Na Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.166-171
    • /
    • 2017
  • Hydrogen gas is a green energy sources because it features no emission of pollutants during combustion. But hydrogen gas is very dangerous, being flammable and very explosive. Hydrogen gas detection is very important for the safety of a nuclear power plant. Hydrogen gas is generated by oxidation of nuclear fuel cladding during a critical accident, and leads to serious secondary damage in the containment building. This paper discusses the development of a Raman lidar system for remote detection and measurement of hydrogen gas. A small, portable Raman lidar system was designed, and a measurement algorithm was developed to quantitatively measure hydrogen gas concentration. To verify the capability of measuring hydrogen gas with the developed Raman lidar system, experiments were carried out under daytime outdoor conditions by using a gas chamber that can adjust the hydrogen gas density. As results, our Raman lidar system is able to measure a minimum density of 0.67 vol. % hydrogen gas at a distance of 20 m.

Experimental Study on Moisture Content According to Addition of Surfactants (계면활성제 첨가에 따른 함수율에 관한 실험적 연구)

  • Kim, Nam-Kyun;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.79-83
    • /
    • 2015
  • The fire accident is a representative type of disaster that can largely impact on business. Therefore, precautionary measures and rapid initial response is very important when a disaster occurs. The storage of porous combustibles is inevitable in coal yard, plywood processing industry, and others that are currently operating. Initial fire fighting of fire and identifying the ignition point in such a porous combustible storage space are so difficult that if the initial response is failed, being led to deep-seated fire, surface fire is likely to result in secondary damage. In addition, deep-seated fire can cause personal injuries and property damage due to a large amount of toxic gases and reignition. Therefore damage reduction measures is required around the storage space to handle a porous flammable. Improving the penetration performance of the concentration of the surfactant is carried out as underlying study, which is about an deep-seated fire extinguishing efficiency augmentation when using wetting agents. The porous materials used in the experiments is radiata pine wood flour, which occupies more than 75% of the domestic wood market. Fire fighting water is selected as Butyl Di Glycol (BDG), which is being used for infiltration extinguishing agent, and the experiment was carried out by producing a standard solution. The experiment was carried out on the basis of the Deep-Seated Fire Test of NFPA 18. The amount of watering, porous material to the internal amount of penetration, and runoff measurement out of the porous material was conducted. According to experimental results, as the surface tension is reduced, the surfactant concentration macroscopic penetration rate decreases, but infiltration to a porous material is shown to have growth characteristics.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

Analysis on Visibility of Delineators by Survey (시선유도시설 시인성 분석에 관한 연구)

  • Kwon, Sung-Dae;Park, Je-Jin;Nam, Chang-Kyu;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5D
    • /
    • pp.445-451
    • /
    • 2012
  • Visual changes and speed changes in curved sections of highways are more dangerous than straight sections According to the enquetes conducted by Coalition for Transportation Culture in 1999, about 78% of drivers are dissatisfied with traffic guide and safety signs, with lack of visibility being the largest reason with about 27.9% of respondents indicating it as reason for dissatisfaction. In particular, the lack of visibility during nighttime or bad weather not only threatens driver safety due to poor delivery of information, but also affects the service level of highways. Because of this a new delineation must be installed and managed to enhance driver visibility. In this research, an optimal delineation system to enhance traffic safety is presented. In this research drivers effectively obtained information on highway alignment on the curved sections using a retro-reflection type delineation system and a newly-developed internal lighting delineation system to improve safety on the highways. A statistical comparison was conducted and analysis was done for the delineation systems that enhanced visibility through primary and secondary enquaetes. As a result, inside-lighting delineator will be selected in terms of safety at the curve sections. The inside-lighting delineator was more effective than the retro-reflection delineator on visibility, the necessity of reduction of speed and will reduce the hazard at curve sections. It is anticipated that when a delineation system based on this research is installed, a reduction in the number the number and severity of traffic accidents on curved sections will be reduced. In addition this system will more effectively provide drivers with information about highway alignment.

Development of an Underwater Rope-cutter Device and Controller for Removal of Propeller and Shaft Foreign Material for Small Vessel (소형선박용 프로펠러 및 샤프트 이물질 제거를 위한 수중절단기 기구 설계 및 제어기 개발)

  • Lee, Hunseok;Oh, Jin-Seok;Choi, Sun-Hong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.927-935
    • /
    • 2019
  • Screw-failure accidents in small ships frequently occur in coastal waters. In particular, vessels' propulsion systems are frequently coiled due to objects such as fish-nets and ropes that float on the sea. The failure of the ship's propulsion system can cause primary accidents such as ship operation delays and drifting due to loss of power; furthermore, the possibility of secondary accidents such as those involving operators in the underwater removal of rope stuck in a propeller. Ships that do not have the proper tools to solve these problems must be either lifted onto land to be repaired or divers must dive directly under the ship to solve the problem. Accordingly, some small vessels have been equipped with rope-cutter devices on the propeller shaft to prevent ship propeller system accidents in recent years; however, they are not being applied efficiently due to the cost and time of installation. To solve these problems, this study develops an underwater rope-cutter device and controller for the removal of propeller and shaft foreign material in small vessels. This device has simple structures that use the principle of a saw. Meteor gears and crank pins were used for the straight-line rotation of saw blades of the underwater rope-cutters to allow for long strokes. Furthermore, the underwater rope-cutting machines can be operated by being connected to the ship battery. The user, a non-professional, can ensure convenience and stability by applying reverse current prevention and a speed control circuit so that it can be used more conveniently and safely.

Factor and Character of Transportation Route Change: The Case Study of Woong-Chi Region in Jeonbuk (교통로 변화의 주요 요인과 특성 -전북 웅치(熊峙, 곰티재) 지역을 중심으로 -)

  • Cho, Sung-Wook
    • Journal of the Korean association of regional geographers
    • /
    • v.14 no.5
    • /
    • pp.587-603
    • /
    • 2008
  • The Woong-Chi region is located between Wan-ju and Jin-an had experienced transportation route change from past continuously. The difference of relative height especially steep slope of western side is given to the most difficulty for transportation route open in Woong-Chi region. For the overcome this restraint geomorphological condition, multi-route were developed according to available purpose in walking period. They effort to decrease of slope and curve in route continual1y, and only used the conditioned route for automobile from 1910s in automobile period. The social aspect in transportation route change on this region is, firstly, the transportation route has trend from variety to simplicity. Secondary, new transportation route is opened by social needs such as traffic accident and social big event. Thirdly, the regional range was extended for overcome restraint condition. Fourthly, the rise and fall of route related settlement is influenced by transportation route change. The used technical method for the overcome the geomorphological condition is make a tunnel, alleviate the curve radius, alleviate the slop and consider the direction of the sunny than shady side.

  • PDF

Reconstruction of the Lower Extremities with the Gracilis Muscle Flap (박근 유리조직을 이용한 하지 재건술)

  • Lee, Jun-Mo;Lee, Ju-Hong
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.62-67
    • /
    • 1998
  • The gracilis muscle is well suited to small and medium-sized soft tissue defects that cannot be adequately handled by simple rotational flaps and it will conform well to irregular contours, can be split longitudinally at both ends to allow cavities and awkwardly shaped spaces and can be transferred in part or in whole. The gracilis muscle used as a free muscle or musculocutaneous flap is small with a long, narrow contour and its vascular pedicle is a terminal branch of the medial femoral circumflex artery and vein. The aims of soft tissue reconstruction are to cover soft tissue defects, to clear up infection and to prepare for further surgical procedures. Authors have performed 12 gracilis muscle flaps in the lower extremities at Chonbuk National University Hospital from June 1994 through March 1998. The results were as follows. 1. 11 cases of 12(91.7%) were sustained from the crushing injury and secondary complications from the traffic accident. 2. The microsurgical anastomosis of one artery and two veins have performed in 6 cases(50%) of 12 and 11(91.7%) cases of 12 were successful at the third postoperative week and in the final result. 3. Gracilis muscle flap is the infetion-resistant and aesthetically acceptable performed in the lower leg 1/3 and the foot.

  • PDF

Oil Fence Durability Enhancement for Marine Environmental Protection : Improvement of Inspection Process (해양환경 보호를 위한 오일펜스의 내구성 향상 : 검정제도 개선 방향)

  • Jang, Pankil;Seo, Jeong Mog;Lee, Heejin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.731-736
    • /
    • 2021
  • Oil fences effectively prevent the spread of oil spilled in the sea, thereby reducing the damage to the marine environment. However, the fence is damaged by oil and structures at the accident site and is discarded. When incinerated disposal method for discarded fences, fine dust, and harmful materials are generated. Moreover, as a part of the damaged fence is dumped into the sea, it may cause secondary environmental pollution, such as microplastics. Therefore, in this study, durability was measured using the most common solid foam type oil fences. As a result, the reduction rate of after five days of contact was 13 % in seawater and 3 % in oil, affected by temperature changes. Thus, the durability of the fence should be improved because it is exposed to seawater and oil and affected by wind, light, and waves depending on the weather conditions. Therefore, we suggest a method to improve the oil fence inspection to strengthen the durability of the fence's fabric part.