• Title/Summary/Keyword: Secondary Accident

Search Result 175, Processing Time 0.023 seconds

Design and Implementation of Sensor-based Secondary Vehicle Accident Prevention System (센서 기반의 차량 2차사고 방지 시스템 설계 및 구현)

  • Lim, Kyung-Gyun;Kim, Gea-Hee;Jeong, Seon-Mi;Mun, Hyung-Jin;Kim, Chang-Geun
    • Journal of Digital Convergence
    • /
    • v.15 no.12
    • /
    • pp.313-321
    • /
    • 2017
  • Traffic accidents in the country have steadily increased. Although IOT technologies have been applied so as to prevent the primary accident, practical solutions to prevent the secondary accident have not been suggested. A general guideline is simply recommended. In this paper, utilizing existing communication technology, we implement a proposed model and its simulation to prevent the secondary accident. When it is possible for a driver to secure visibility, the secondary accident can be prevented; In areas like tunnel, mountain terrain, and curve road with heavy traffic, where the driver has difficulty in securing the visibility, the secondary accident rates after the primary accident have been increasing. Therefore, we implement an accident prevention system that determines the primary accident utilizing sensor technology and prevents the secondary accident communicating through V2V or V2I. After the simulation, we found that the proposed model and the existing model made no difference with regard to the secondary accident rates when the visibility of the driver is secured; With the application of the proposed model, however, the accident rates decreased for 3-7 percent even though the visibility and communication were not secured.

Effect of Prior Information Given by Video type VMS on Reduction of Secondary Accidents in Tunnels (동영상식 VMS로 사전정보제공시 터널 내 2차사고 감소효과에 관한 연구)

  • Shin, So Myoung;Lee, Soo Beom;Kim, Hyung Kyu;Park, Min Jai;Kim, Kyoung Tae
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.2
    • /
    • pp.56-62
    • /
    • 2019
  • Secondary accident is common type of accident which occurs in Korean highway tunnels. Fatality rate of secondary accidents in highway tunnels is six time higher than primary accidents. Video type VMS is a new way of providing information to road users which was recently introduced by Korean government to prevent secondary accidents in highway tunnels. In this study we compared changes in driver's behavior when information is provided by Text type and Video Type VMS. In addition to analyze effects of secondary accident reduction, driving behavior was analyzed based on providing advance information by video type VMS at tunnel entrance. Analysis showed that both text type and video type VMS has similar effect on driver behavior. Video type VMS showed positive effect on driver's behavior to prevent secondary accident when information is provided 1km ahead of accident. Considering there results and the short-term memory characteristics of driver, it was determined that information should be provide at about 650m from the entrance of the tunnel. The results of this study are consistent with the requirement that VMS should be installed at least 500m ahead of tunnel and produce more accurate providing information points. 650m is also appropriate interval for providing information in tunnel to cope with an accident ahead.

ROSA/LSTF test and RELAP5 code analyses on PWR steam generator tube rupture accident with recovery actions

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.981-988
    • /
    • 2018
  • An experiment was performed for the OECD/NEA ROSA-2 Project with the large-scale test facility (LSTF), which simulated a steam generator tube rupture (SGTR) accident due to a double-ended guillotine break of one of steam generator (SG) U-tubes with operator recovery actions in a pressurized water reactor. The relief valve of broken SG opened three times after the start of intact SG secondary-side depressurization as the recovery action. Multi-dimensional phenomena specific to the SGTR accident appeared such as significant thermal stratification in a cold leg in broken loop especially during the operation of high-pressure injection (HPI) system. The RELAP5/MOD3.3 code overpredicted the broken SG secondary-side pressure after the start of the intact SG secondary-side depressurization, and failed to calculate the cold leg fluid temperature in broken loop. The combination of the number of the ruptured SG tubes and the HPI system operation difference was found to significantly affect the primary and SG secondary-side pressures through sensitivity analyses with the RELAP5 code.

Measures for Preventing Pressure Fracture of Fire and Flue Tube Boiler (노통연관식 보일러의 압궤사고 방지대책)

  • Lee Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.4 s.68
    • /
    • pp.14-19
    • /
    • 2004
  • Boiler is a hazardous equipment to have potential explosion ail the time. And not only it has malfunction at explosion. it lead to people death but also secondary accident such as explosion and fire. Therefore, this equipment should not be broken for keeping its own function. And also, high level of safety should be kept in the process of the use not to be malfunctioned. A large scale of accident due to boiler explosion can be preventive in advance. Boiler fracture is occurred by instant expansion (approximately 1700 time) from quick evaporation of rater in boiler, due to pressure decrease in boiler Emitting energy from it is tremendous and it is so dangerous because of its high temperature. Secondary explosion such as fire is also a main hazard occurring at fuel supply place. If any devices with high pressure is broken, then not only boiler vessel but also components of it are spread with high speed, causing secondary accident. This study is to analyze integrally accident cause of fire and flue tube boiler to have occurred pressure fracture actually, to show countermeasures to prevent accident loss from the fire and flue tube boiler.

A Study on safety against a fire of charging cable for mobile phone for vehicle (자동차용 모바일 폰 충전 케이블의 발화 안전성에 관한 연구)

  • Kwon, Jin-Wook;Choi, Kyu-Sik;Hwang, Myung-Whan
    • Journal of the Korea Safety Management & Science
    • /
    • v.20 no.3
    • /
    • pp.21-26
    • /
    • 2018
  • This paper describes result of a study on safety against a fire of charging cable for mobile phone for vehicle. Combustion on the USB cable in the car was happened while driving. Gas coming from the burning USB cable could be a reason which can make a secondary car accident since the driver also can be embarrassed while driving. In order to prevent a secondary car accident connected on the road, to research a reason why USB cable can emit gas and be burned in charging. We did simulation test with abnormal fault condition for the electronic component on the board in the USB cable. So we get the result from abnormal fault condition simulation test, for instance, shorted test for output terminal of 8 pin switch, shorted test for chip resistor after thermal aging in the condition $25^{\circ}C$, 93 % RH during 48 hours. To analysis the result of all test, Combustion on the USB cable was not the 8 pin but other electrical component such as a chip resistor. Therefore we guess that the reason for USB cable combustion in charging in a car was not 8 pin and a LED but another defective component.

Study on the Damage Pattern Analysis of a 3 Phase 22.9/3.3kV Oil Immersed Transformer and Judgment of the Cause of Its Ignition (3상 22.9/3.3kV 유입변압기의 소손패턴 해석 및 발화원인 판정에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1274-1279
    • /
    • 2011
  • The purpose of this paper is to present the manufacturing defect and damage pattern of a 3 phase 22.9/3.3kV oil immersed transformer, as well as to present an objective basis for the prevention of a similar accident and to secure data for the settlement of PL related disputes. It was found that in order to prevent the occurrence of accidents to transformers, insulating oil analysis, thermal image measurement, and corona discharge diagnosis, etc., were performed by establishing relevant regulation. The result of analysis performed on the external appearance of a transformer to which an accident occurred, the internal insulation resistance and protection system, etc., showed that most of the analysis items were judged to be acceptable. However, it was found that the insulation characteristics between the primary winding and the enclosure, those between the ground and the secondary winding, and those between the primary and secondary windings were inappropriate due to an insulating oil leak caused by damage to the pressure relief valve. From the analysis of the acidity values measured over the past 5 years, it is thought that an increase in carbon dioxide (CO2) caused an increase in the temperature inside the transformer and the increase in the ethylene gas increased the possibility of ignition. Even though 17 years have passed since the transformer was installed, it was found that the system's design, manufacture, maintenance and management have been performed well and the insulating paper was in good condition, and that there was no trace of public access or vandalism. However, in the case of transformers to which accidents have occurred, a melted area between the upper and the intermediate bobbins of the W-phase secondary winding as well as between its intermediate and lower bobbins. It can be seen that a V-pattern was formed at the carbonized area of the transformer and that the depth of the carbonization is deeper at the upper side than the lower side. In addition, it was found that physical bending and deformation occurred inside the secondary winding due to non-uniform pressure while performing transformer winding work. Therefore, since it is obvious that the accident occurred due to a manufacturing defect (winding work defect), it is thought that the manufacturer of the transformer is responsible for the accident and that it is lawful for the manufacture to investigate and prove the concrete cause of the accident according to the Product Liability Law (PLL).

A Study on the Area Calculation and Spatial Composition of Medical Rehabilitation Center in the Workplace Accident Rehabilitation Hospitals (산재재활전문병원 재활센터의 규모 및 공간구성에 관한 연구)

  • Lee, Teuk-Koo;Choi, Kwang-Seok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.14 no.2
    • /
    • pp.3-14
    • /
    • 2008
  • The rehabilitation for the workplace accident victims is basically aimed to get them back to their working place through the secondary care processes which have some more special and more professional rehabilitation than any others, after the primary treatments like operation in an acute hospital since the accident. They need more concentrative rehabilitation efforts according to classified injury types during the period of acute, sub-acute and convalescent. This study is for the partial research of rehabilitation hospital for workers' accident victims and presents design data which can be used for the appropriate area calculation and spatial composition. Drawing documents analysis, interviews, observation were used to examine the condition of existing rehabilitation hospitals.

  • PDF

Analysis of MSGTR-PAFS Accident of the ATLAS using the MARS-KS Code (MARS-KS 코드를 사용한 ATLAS 실험장치의 MSGTR-PAFS 사고 분석)

  • Jeong, Hyunjoon;Kim, Taewan
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.74-80
    • /
    • 2021
  • Korea Atomic Energy Research Institute (KAERI) has been operating an integral effects test facility, the Advanced Thermal-Hydraulic Test Loop for Accident Simulation (ATLAS), according to APR1400 for transient experimental and design basis accident simulation. Moreover, based on the experimental data, the domestic standard problem (DSP) program has been conducted in Korea to validate system codes. Recently, through DSP-05, the performance of the passive auxiliary feedwater system (PAFS) in the event of multiple steam generator tube rupture (MSGTR) has been analyzed. However, some errors exist in the reference input model distributed for DSP-05. Furthermore, the calculation results of the heat loss correlation for the secondary system presented in the technical report of the reference indicate that a large difference is present in heat loss from the target value. Thus, in this study, the reference model is corrected using the geometric information from the design report and drawings of ATLAS. Additionally, a new heat loss correlation is suggested by fitting the results of the heat loss tests. Herein, MSGTR-PAFS accident analysis is performed using MARS-KS 1.5 with the improved model. The steady-state calculation results do not significantly differ from the experimental values, and the overall physical behavior of the transient state is properly predicted. Particularly, the predicted operating time of PAFS is similar to the experimental results obtained by the modified model. Furthermore, the operating time of PAFS varies according to the heat loss of the secondary system, and the sensitivity analysis results for the heat loss of the secondary system are presented.

The Accident at Tokyo Electric Power Company Incorporated's Fukushima Daiichi Nuclear Power Station: A Review of Radiation-Exposed Medical Care and Waste (Secondary Publication)

  • Toshioh Fujibuchi;Kazuki Iwaoka;Yoko Shimada;Kuniaki Nabatame
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.2
    • /
    • pp.65-67
    • /
    • 2024
  • This review is based on articles published in Japanese Journal of Health Physics on "Radiation-exposed medical care and waste" related to Tokyo Electric Power Company Incorporated (TEPCO)'s Fukushima Daiichi Nuclear Power Station accident. Here, we have considered three original articles; one technical data, one special article, one 50th anniversary article, one preface, three topics, and two cases of From Japan to the World (J to W). These articles have reported the system and standards that were established after the accident. Moreover, they have summarized rare experiences such as the fumbling response at the time and the evaluation of samples in that disaster. These articles constitute valuable records of the situation.

Modeling and analysis of selected organization for economic cooperation and development PKL-3 station blackout experiments using TRACE

  • Mukin, Roman;Clifford, Ivor;Zerkak, Omar;Ferroukhi, Hakim
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.356-367
    • /
    • 2018
  • A series of tests dedicated to station blackout (SBO) accident scenarios have been recently performed at the $Prim{\ddot{a}}rkreislauf-Versuchsanlage$ (primary coolant loop test facility; PKL) facility in the framework of the OECD/NEA PKL-3 project. These investigations address current safety issues related to beyond design basis accident transients with significant core heat up. This work presents a detailed analysis using the best estimate thermal-hydraulic code TRACE (v5.0 Patch4) of different SBO scenarios conducted at the PKL facility; failures of high- and low-pressure safety injection systems together with steam generator (SG) feedwater supply are considered, thus calling for adequate accident management actions and timely implementation of alternative emergency cooling procedures to prevent core meltdown. The presented analysis evaluates the capability of the applied TRACE model of the PKL facility to correctly capture the sequences of events in the different SBO scenarios, namely the SBO tests H2.1, H2.2 run 1 and H2.2 run 2, including symmetric or asymmetric secondary side depressurization, primary side depressurization, accumulator (ACC) injection in the cold legs and secondary side feeding with mobile pump and/or primary side emergency core coolant injection from the fuel pool cooling pump. This study is focused specifically on the prediction of the core exit temperature, which drives the execution of the most relevant accident management actions. This work presents, in particular, the key improvements made to the TRACE model that helped to improve the code predictions, including the modeling of dynamical heat losses, the nodalization of SGs' heat exchanger tubes and the ACCs. Another relevant aspect of this work is to evaluate how well the model simulations of the three different scenarios qualitatively and quantitatively capture the trends and results exhibited by the actual experiments. For instance, how the number of SGs considered for secondary side depressurization affects the heat transfer from primary side; how the discharge capacity of the pressurizer relief valve affects the dynamics of the transient; how ACC initial pressure and nitrogen release affect the grace time between ACC injection and subsequent core heat up; and how well the alternative feeding modes of the secondary and/or primary side with mobile injection pumps affect core quenching and ensure stable long-term core cooling under controlled boiling conditions.