Stepwise Inertial Control of a Doubly-Fed Induction Generator to Prevent a Second Frequency Dip

  • Kang, Mose;Lee, Jinsik;Hur, Kyeon;Park, Sang Ho;Choy, Youngdo;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2221-2227
    • /
    • 2015
  • To arrest a frequency nadir, a stepwise inertial control (SIC) scheme generates a constant active power reference signal of a wind turbine generator (WTG) immediately after a disturbance and maintains it for the predetermined time. From that point, however, the reference of a WTG abruptly decreases to restore the rotor speed for the predefined period. The abrupt decrease of WTG output power will inevitably cause a second frequency dip. In this paper, we propose a modified SIC scheme of a doubly-fed induction generator (DFIG) that can prevent a second frequency dip. A reference value of the modified SIC scheme consists of a reference for the maximum power point tracking control and a constant value. The former is set to be proportional to the cube of the rotor speed; the latter is determined so that the rotor speed does not reach the minimum operating limit by considering the mechanical power curve of a DFIG. The performance of the modified SIC was investigated for a 100 MW aggregated DFIG-based wind power plant under various wind conditions using an EMTP-RV simulator. The results show that the proposed SIC scheme significantly increases the frequency nadir without causing a second frequency dip.

회전자 속도와 주파수 편차에 따라 변하는 가변게인을 이용한 플라이휠 에너지 저장장치의 주파수 제어 (Frequency control of flywheel energy storage system based on a variable gain depending on the rotor speed and frequency deviation)

  • 이혜원;나운기;김종훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.354-355
    • /
    • 2018
  • Flywheel energy storage system (FESS) operates motor or generator by utilizing the stored kinetic energy in the rotating mass. Thus, the FESS can support the frequency control of the power system. However, the FESS is disabled when the rotor speed reaches to its minium value. Thus, the second frequency dip occurs in the power system. This paper proposes the frequency control scheme of FESS based on a variable gain depending on the rotor speed and frequency deviation. The proposed scheme prevents the second frequency dip because the variable gain decreases depending on the stored in the FESS. The performance of the proposed scheme is investigated for the IEEE 14-bus system.

  • PDF

Hybrid Reference Function for Stable Stepwise Inertial Control of a Doubly-Fed Induction Generator

  • Yang, Dejian;Lee, Jinsik;Hur, Kyeon;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.86-92
    • /
    • 2016
  • Upon detecting a frequency event in a power system, the stepwise inertial control (SIC) of a wind turbine generator (WTG) instantly increases the power output for a preset period so as to arrest the frequency drop. Afterwards, SIC rapidly reduces the WTG output to avert over-deceleration (OD). However, such a rapid output reduction may act as a power deficit in the power system, and thereby cause a second frequency dip. In this paper, a hybrid reference function for the stable SIC of a doubly-fed induction generator is proposed to prevent OD while improving the frequency nadir (FN). To achieve this objective, a reference function is separately defined prior to and after the FN. In order to improve the FN when an event is detected, the reference is instantly increased by a constant and then maintained until the FN. This constant is determined by considering the power margin and available kinetic energy. To prevent OD, the reference decays with the rotor speed after the FN. The performance of the proposed scheme was validated under various wind speed conditions and wind power penetration levels using an EMTP-RV simulator. The results clearly demonstrate that the scheme successfully prevents OD while improving the FN at different wind conditions and wind power penetration levels. Furthermore, the scheme is adaptive to the size of a frequency event.

Virtual Flux and Positive-Sequence Power Based Control of Grid-Interfaced Converters Against Unbalanced and Distorted Grid Conditions

  • Tao, Yukun;Tang, Wenhu
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1265-1274
    • /
    • 2018
  • This paper proposes a virtual flux (VF) and positive-sequence power based control strategy to improve the performance of grid-interfaced three-phase voltage source converters against unbalanced and distorted grid conditions. By using a second-order generalized integrator (SOGI) based VF observer, the proposed strategy achieves an AC voltage sensorless and grid frequency adaptive control. Aiming to realize a balanced sinusoidal line current operation, the fundamental positive-sequence component based instantaneous power is utilized as the control variable. Moreover, the fundamental negative-sequence VF feedforward and the harmonic attenuation ability of a sequence component generator are employed to further enhance the unbalance regulation ability and the harmonic tolerance of line currents, respectively. Finally, the proposed scheme is completed by combining the foregoing two elements with a predictive direct power control (PDPC). In order to verify the feasibility and validity of the proposed SOGI-VFPDPC, the scenarios of unbalanced voltage dip, higher harmonic distortion and grid frequency deviation are investigated in simulation and experimental studies. The corresponding results demonstrate that the proposed strategy ensures a balanced sinusoidal line current operation with excellent steady-state and transient behaviors under general grid conditions.

SO2 제거를 위한 유전체 장벽 방전 - 광촉매 복합 공정에서의 입자 형성과 성장 (Particle Formation and Growth in Dielectric Barrier Discharge - Photocatalysts Hybrid Process for SO2 Removal)

  • 나소노바 안나;김동주;김교선
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.127-132
    • /
    • 2010
  • We analyzed the effects of several process variables on the $SO_2$ removal and particle growth by the dielectric barrier discharge - photocatalysts hybrid process. In this process, $SO_2$ was converted into the ammonium sulfate ($(NH_4)_2SO_4$) particles. The size and crystallinity of ammonium sulfate particles were examined by using TEM and XRD analysis. The dielectric barrier discharge reactor consisted of two zones: the first is for plasma generation and the second is for ammonium sulfate particles formation and growth. The first zone of reactor was filled with glass beads as a dielectric material. To enhance $SO_2$ removal process, the $TiO_2$ photocatalysts were coated on glass beads by dip-coating method. As the voltage applied to the plasma reactor or the pulse frequency of applied voltage increases, the $SO_2$ removal efficiency increases. Also as the initial concentration of $SO_2$ decreases or as the residence time increases, the $SO_2$ removal efficiency increases. $(NH_4)_2SO_4$ particles continue to grow by particle coagulation and surface reaction, moving inside the reactor. Larger particles in site are produced according to the increase of residence time or $SO_2$ concentrations.

  • PDF

원위지 골절에 K-강선을 이용한 비관혈적 정복술 후 생긴 아급성 골수염 1례 (Subacute Osteomyelitis on Phalangeal Bone Resulting from Multiple Kirschner Pin Fixation: Case Report)

  • 김재우;최환준;김미선;김준혁
    • Archives of Plastic Surgery
    • /
    • 제34권3호
    • /
    • pp.409-412
    • /
    • 2007
  • Purpose: Percutaneous Kirschner wire fixation is common method for hand fracture. It is simple but has risk of ascending infection through the pin and bony injury by multiple drilling. Ascending infection through pin tract is mostly superficial and can be treated with antibiotics and aseptic dressing. This is a case review of subacute osteomyelitis on phalangeal bones after Kirschner wire fixation with literature review. Methods: A 40-years-old man with distal phalangeal fracture on right second finger is presented. He went to a local clinic and had percutaneous Kirschner wire fixation under local anesthesia. He was transferred to our hospital for ulcerative wound on DIP joint at 4 weeks after operation. Radiography showed osteolytic change around medulla of middle and distal phalanges, leading to diagnosis of a subacute osteomyelitis. We treated it with amputation at the level of shaft of middle phalanx. Results: The postoperative course was uneventful. We thought several possible reasons for osteomyelitis in our case. First, it could resulted from ascending infection through the wire. Second, it could be resulted from a bony burn by repeated drilling. And bony necrosis could be a consequence of arterial insufficiency caused by 2 pin insertion. Conclusion: We suggest that a precise pinning based on accurate anatomical understanding is required for a percutaneous Kirschner wire fixation. The frequency of drilling should be minimized. Careful observation and patient education for pin site care are essential.