• 제목/요약/키워드: Seawater immersion

검색결과 49건 처리시간 0.021초

바다에서 건진 절단된 하지 원위부의 재접합 (Replantation of a Distal Lower Leg in an Elderly Patient After Retrieval of the Limb from Seawater Immersion)

  • 우상현;오경석
    • Archives of Reconstructive Microsurgery
    • /
    • 제9권2호
    • /
    • pp.186-189
    • /
    • 2000
  • A case of distal lower leg replantation, in an elderly patient, was successfully performed after retrieval of the amputated limb from 3 hours of immersion in seawater. Due to the patient's age, bony union was delayed and functional nerve recovery was unsatisfactory. After massive saline irrigation of the amputated part, employing a catheter through the main artery, as well as, prophylactic antibiotics to prevent infection by Aeromonas, there were no postoperative complications. Despite the issue of age, immersion of an amputated part into seawater is not a contraindication of replantation.

  • PDF

광물질혼화재 혼합 모르타르의 해수침식 저항성 (Seawater Attack Resistance of Mortars Containing Mineral Admixtures)

  • 문한영;이승태;최강식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.527-530
    • /
    • 2002
  • In the present study, immersion test using artificial seawater was performed to evaluate the resistance of mortar specimens with or without ground granulated blast-furnace slag (SG) and fly ash (FA). Another variable was the fineness levels of SG (4,450, 6,000 and 8,000 ㎠/g). From the results of the immersion test for 270 days of exposure, the excellent resistance to seawater attack for SG mortar mixtures, especially in a high fineness levels, was confirmed. However, the reductions in compressive strength of FA mortar specimens was similar to those of OPC mortar specimens irrespective of replacement of FA.. In order to understand the deterioration mechanism due to seawater attack, X-ray diffraction (XRD) analysis were also carried out. Some reactants such as ettringite, gypsum, brucite and Friedel's salt were possibly detected through XRD technique.

  • PDF

강섬유보강콘크리트의 내해수성에 관한 실험적 연구 (An Experimental Study on the Seawater Resistance of Steel Fiber Reinforced Concrete)

  • 박승범;오광진;장석호;이봉춘
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.315-322
    • /
    • 1997
  • This paper describes an experimental study on the seawater resistance of steel fiber reinforced concrete. The test method adopted for this study may be devided into long-term immersion test and accelerated test by wetting and drying. Test were carried out to evaluate the procedure in which reduction in dynamic modulus, length change and compressive strength to nine months were measured. Resistance indicators are the water - cement ratio, the content of steel fiber, the immersion water(artificial seawater or freshwater). The conditions of intervals of immersing in artificial seawater and drying, low water-cement ratio, and non-steel fiber became most deteriorated.

  • PDF

플라이애쉬를 혼입한 강섬유보강콘크리트의 내해수성에 관한 실험적 연구 (An Experimental Study on the Seawater Resistance of Steel Fiber Reinforced concrete Using Fly Ash)

  • 박승범;오광진
    • 콘크리트학회지
    • /
    • 제9권3호
    • /
    • pp.189-197
    • /
    • 1997
  • 본 연구에서는 보통의 일반콘크리트와 플라이애쉬를 혼입한 강섬유보강 콘크리트의 해수에 대한 저항성을 고찰하기 위하여 수행되었다. 콘크리트 배합 인자를 물.시멘트비, 강섬유혼입률, 플라이애쉬 혼입률별로 각각 제조하였으며, 표준수(수도물)와 인공으로 제조한 해수에 장기간 침지한 경우와 건조와 습윤의 반복작용에 의한 촉진시험으로 시험을 수행하여 콘크리트의 성능저하에 미치는 영향을 비교.고찰하였다. 시험방법은 소정의 재령에 각각의 배합조건별로 압축강도와 재령 1일을 기준으로 길이변화와 동탄성계수를 측정하여 성능저하정도를 비교분석하였다. 그 결과 강섬유와 플라이애쉬의 적정량의 혼입은 콘크리트의 내해수성을 현저히 개선시키는 효과를 나타내었다.

해수배관 내부 에폭시 코팅재의 캐비테이션 및 침지 열화에 따른 압입인장특성 (Indentation Tensile Properties of Seawater Piping with Cavitation and Immersion Degradation)

  • 정민재;김수현;전종모;김영식;김영천
    • Corrosion Science and Technology
    • /
    • 제22권6호
    • /
    • pp.419-428
    • /
    • 2023
  • Seawater has been used to cool devices in nuclear power plants. However, the pipes used to transport seawater are vulnerable to corrosion; hence, the inner side of pipelines is coated with an epoxy layer as prevention. Upon coating damage, the pipe becomes exposed, and corrosion progresses. The major cause is widely known as cavitation corrosion, causing the degradation of mechanical properties. In this study, corroded specimens were prepared using cavitation and immersion methods to clarify the degradation trend of mechanical properties with corrosion. Three different types of epoxy coatings were used, and accelerated cavitation procedures were composed of amplitudes of 15 ㎛, 50 ㎛, and 85 ㎛ for 2 h, 4 h, and 6 h. The immersion periods were 3 and 6 weeks. We conducted instrumented indentation tests on all degradation samples to measure mechanical properties. The results showed that higher cavitation amplitudes and longer cavitation or immersion times led to more degradation in the samples, which, in turn, decreased the yield strength. Of the three samples, the C coating had the highest resistance to cavitation and immersion degradation.

FRP 어선 보수에 적용되는 겔코트의 해수 침투 방지 효과 (The Prevention Effect of Seawater Penetration of Gel Coat Applied in Repair of FRP Fishing Vessel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.15-21
    • /
    • 2018
  • Ships may collide with reefs or other objects during operation, when arriving or departing ports. The hull plate may be damaged due to the contact with other ships. The total number of domestic powered fishing vessels has decreased, but that of FRP fishing vessels has increased by 0.7% and the ratio of FRP fishing vessels to the total fishing vessels increased to 96%. Recently, fishing vessels has been used as fishing boats for income of non-fishermen as well as fishermen. Therefore, safety management for repair and maintenance is necessary. The penetration of moisture and moisture in the composite material such as FRP may deteriorate the mechanical properties and the salt (NaCl) component of the damaged portion may cause a relatively high deterioration in material strength. The gel coat painting is the final stage of repairs ans maintenance of FRP fishing vessels. The thickness criteria in the domestic and foreign gel coat is 0.3~0.762 mm. The joint specimens, which was immersed in seawater for 120 days, were compared with those without seawater immersion. As a result, the tensile strength was 83 ~ 121.8% and the flexural strength was 83 ~ 113% compared with the specimens without seawater immersion. According to the previous study the tensile strength decreased by more than 29% and the flexural strength decreased by more than 50% when the composite material was immersed in seawater for 1,083 hours without coating. As a result, it was found that the gel coat with 0.5 mm thickness is very effective in preventing the strength decrease of the composite material.

Seawater ballast tank 환경에서 저합금강의 내식성에 미치는 합금원소의 영향 (Effects of Alloying Elements on Corrosion Resistance of Low Alloyed Steels in a Seawater Ballast Tank Environment)

  • 김동우;김희산
    • 대한금속재료학회지
    • /
    • 제48권6호
    • /
    • pp.523-532
    • /
    • 2010
  • Co-application of organic coating and cathodic protection has not provided enough durability to low-alloyed steels inseawater ballast tank (SBT) environments. An attempt has made to study the effect of alloy elements (Al, Cr, Cu, Mo, Ni, Si, W) on general and localized corrosion resistance of steels as basic research to develop new low-allowed steels resistive to corrosion in SBT environments. For this study, we measured the corrosion rate by the weigh loss method after periodic immersion in synthetic seawater at $60^{\circ}C$, evaluated the localized corrosion resistance by an immersion test in concentrated chloride solution with the critical pH depending on the alloy element (Fe, Cr, Al, Ni), determined the permeability of chloride ion across the rust layer by measuring the membrane potential, and finally, we analyzed the rust layer by EPMA mapping and compared the result with the E-pH diagram calculated in the study. The immersion test of up to 55 days in the synthetic seawater showed that chromium, aluminium, and nickel are beneficial but the other elements are detrimental to corrosion resistance. Among the beneficial elements, chromium and aluminium effectively decreased the corrosion rate of the steels during the initial immersion, while nickel effectively decreased the corrosion rate in a longer than 30-day immersion. The low corrosion rate of Cr- or Al-alloyed steel in the initial period was due to the formation of $Cr_2FeO_4$ or $Al_2FeO_4$, respectively -the predicted oxide in the E-pH diagram- which is known as a more protective oxide than $Fe_3O_4$. The increased corrosion rate of Cr-alloyed steels with alonger than 30-day exposure was due to low localized corrosion resistance, which is explained bythe effect of the alloying element on a critical pH. In the meantime, the low corrosion rate of Ni-alloyed steel with a longer than 30-day exposure wasdue to an Ni enriched layer containing $Fe_2NiO_4$, the predicted oxide in the E-pH diagram. Finally, the measurement of the membrane potential depending on the alloying element showed that a lower permeability of chloride ion does not always result in higher corrosion resistance in seawater.

수중불분리성 콘크리트의 해수침식에 대한저항성 평가 (Assessment on the Seawater Attack Resistance of Antiwashout Underwater Concrete)

  • 문한영;김성수;안태송;이승태;김종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.683-688
    • /
    • 2001
  • In case of constructing the concrete structures under seawater environment, the concrete suffers from deterioration due to penetration of various ions such as chloride, sulfate and magnesium in seawater. Tn the present study, Immersion tests with artificial seawater were carried out to investigate the resistance to seawater attack of antiwashout underwater concrete. From the results of compressive strength, it was found that blended cement concrete due to mineral admixtures such as fly ash(FA) and ground granulated blast-furnace slag(SGC), were superior to ordinary portland cement concrete with respect to the resistance to seawater attack. Moreover, XRD analysis indicated that the formed reactants of ordinary portland cement paste by sulfate and magnesium ions led to the deterioration of concrete. As expected, however, the blended cements with FA or SGC have a good resistance to seawater attack. This paper would discuss the mechanism of seawater deterioration and benefical effects of antiwashout underwater concretes with mineral admixtures.

  • PDF

시멘트 클린커광물의 수화에 미치는 해수성분의 영향 (II) 인공해수에서의 촉진시험 (The Effect of Seawater on the Hydration of Clinker Minerals (II) Acceleration Experiment in the Artificial Seawater)

  • 신도철;송태웅;최상흘;한기성
    • 한국세라믹학회지
    • /
    • 제25권1호
    • /
    • pp.15-20
    • /
    • 1988
  • In this study, the specimens of cement clinker minerals such as 80C3-S-15C4AF-5C3A added various blending materials were immersed in artificial seawater. In order to ascertain the effect of SO3 and blending materials on seawater resistance of the specimens, the acceleration experiment in the artificial seawater was carried out by repeating of immersion and drying operation periodically. As inner part of the specimen immersed in artificial seawater, Friedel's salt was produced by reaction with Cl ion. In outer part of the specimen, gypsum and ettringite were mainly formed. With the increase of SO3 content in the specimen the formation of ettringite was increased and Frieldel's salt in inner part was decreased. Total pore volume of the specimens was increased according to the amount of Cl ion penetrated and Mg(OH)2 leached in the solution.

  • PDF

시멘트 경화체의 해수침식에 의한 성능저하 및 저항성 평가 (Evaluation on the Deterioration and Resistance of Cement Matric due to Seawater Attack)

  • 문한영;이승태;김홍삼
    • 콘크리트학회논문집
    • /
    • 제13권2호
    • /
    • pp.175-183
    • /
    • 2001
  • 국내에서 생산되는 5종류 시멘트로 제조한 시멘트 경화체의 해수침식에 대한 저항성을 알아보기 위한 목적으로 2배농도 인공 해수에 각각 400일 및 800일동안 침지시켜 모르타르의 압축강도 및 길이변화를 측정한 결과, 혼합시멘트계 모르타르가 광물질혼 화재의 영향으로 포틀랜드시멘트계 모르타르와 비교하여 좋은 결과를 나타내었다. 또한 시멘트 페이스트의 XRD분석에 의한 수 화 및 반응생성물의 피크강도비를 살펴보면, 포틀랜드시멘트계 페이스트 중 저열포틀랜드시멘트의 피크강도비가 가장 작았으며, 혼합시멘트계 페이스트의 경우 portlandite 및 brucite의 피크강도비가 포틀랜드시멘트계 페이스트보다 작았다. 인공해수 침식으 로 인한 시멘트 페이스트의 공극량을 수은압입법으로 측정한 결과에 의하면 보통포틀랜드시멘트 페이스트의 총공극량이 가장 크게 나타났으나, 포틀랜드시멘트에 고로슬래그미분말 및 플라이애시를 혼합한 혼합시멘트계 페이스트의 경우 총공극량이 각각 약 56% 및 약 32 % 정도 저감되는 효과가 있었다.