• Title/Summary/Keyword: Seawater fluid

Search Result 114, Processing Time 0.026 seconds

Performance Analysis of Ocean Thermal Energy Conversion on Working Fluid Classification (작동유체에 따른 온도차발전사이클의 성능 해석)

  • Lee, Ho-Saeng;Moon, Jung-Hyun;Kim, Hyeon-Ju
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.79-84
    • /
    • 2016
  • The thermodynamic performance of ocean thermal energy conversion with 1 kg/s geothermal water flow rate as a heat source was evaluated to obtain the basic data for the optimal design of cycle with respect to the classification of the working fluid. The basic thermodynamic model for cycle is rankine cycle and the geothermal water and deep seawater were adapted for the heat source of evaporator and condenser, respectively. R245fa, R134a are better to use as a working fluid than others in view of the use of geothermal water. It is important to select the proper working fluid to operate the ocean thermal energy conversion. So, this paper can be used as the basic data for the design of ocean thermal energy conversion with geothermal water and deep seawater.

Comparison Study of the Impact Response Characteristics of Fixed Cylindrical Offshore Structures Considering Seawater Fluid Region (해수유체영역을 고려한 고정식 실린더형 해양구조물의 충격응답특성 비교연구)

  • Lee, Kangsu;Hong, Keyyong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.489-494
    • /
    • 2015
  • This research focused on minimizing the response of fixed cylindrical offshore structures to a ship impact considering the seawater fluid part. A collision between a ship and offshore structure is generally a complex problem and it is often impractical to perform rigorous finite element analyses to include all the effects and sequences during the collision. The structural behavior of a fixed cylindrical type offshore substructure with a seawater fluid part has a simpler response and small deformation due to the dissipation of impact energy. Upon applying the impact force of a ship to the cylindrical structure, the maximum acceleration, internal energy, and plastic strain are calculated for each load cases using Ls-dyna finite element software. In the maximum cases 2.0 m/s velocity, the response result for the structure was carried out to compare between having a fluid region and no fluid region. Fluid-structure interaction analysis was performed using the ALE method, which make it possible to apply a fluid region on the impact problem. The case of a fixed cylindrical type offshore structure without a seawater fluid part can be a more conservative design.

The Numerical Analysis of Fluid Flow in the Tube Cleaning System (튜브 클리닝 시스템 내부의 유동 특성에 관한 수치해석적 연구)

  • Jung, Kyung-Chul;Lee, Chi-Woo
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • The numerical analysis of fluid flow in the tube cleaning system is examined. The working flow used in this study is seawater, and the temperature change is not considered as the temperature change of seawater in the tube cleaning system is negligible. Also, the analysis is performed under the assumption of steady state. The screens of complicated morphologies are simplified for the analysis, and only one fourth of the tube cleaning system is modeled as the system has a symmetrical shape. The velocity inlet boundary condition is employed for the seawater inlet, whereas the outflow boundary condition is employed for two seawater outlets. In applying the outflow boundary condition for the system with more than two outlets, the flow rate can be arbitrarily assigned. In the analysis, the finite-volume method based numerical analysis tool, the pressure based solver, the standard k-$\varepsilon$ model are utilized, and the under relaxation factor is modified appropriately. From the analysis, the distribution of velocity vectors, pressure and path lines are obtained, and the physical characteristics of fluid flow in the tube cleaning system is well-examined.

Design and Analysis of Heat Exchanger Using Sea Water Heat Source for Cooling

  • Kim, MyungRae;Lee, JuHee;Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.25-34
    • /
    • 2016
  • Purpose: The temperature in Seoul has risen 3 times more than the average global temperature increase for the past 100 years. Today, summer starts 15 days earlier than the early 20th century and is 32 days longer. This tendency causes rapid increase of cooling energy demand. Following this effect, seawater heat resources are to be used as an countermeasure for global warming. Incheon Port near the Western Sea has the lowest water temperature in the winter in South Korea in which it is suitable to use seawater cold heat resources. Method: The cold heat resource is gained from seawater when the water temperature is the lowest in the winter time and saved in a seasonal thermal storage. This can be used as cold heat resource in the summer time. A heat exchanger is essential to gain seawater cold energy. Due to this necessity, sea water heat resource heat exchangers are modeled by heat transfer equations and the fluid characteristics are analyzed. Also, a CFD (computational fluid dynamics) program is used to conduct simulation on the fluid characteristics of heat exchangers. The analyzed data of deducted from this process are comprehensively analyzed and discussed. Result: Regarding the performance of the heat exchanger, the heat exchanger was operated following the prediction within the range of heat transfer rate of minimum 3.3KW to maximum 33.6KW per device. In the temperature change analysis of the heat exchanger, fluid analysis by heat transfer equations almost corresponded to the temperature change by CFD simulation. Therefore, it is considered that the results of this study can be used as design data of heat exchangers.

Cause Analysis for a Lining Damage in Sea Water System Piping Installed in a Korean Industrial Plant

  • Hwang, K.M.;Park, S.K.
    • Corrosion Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Many Korean industrial plants including nuclear and fossil power plants use seawater as the ultimate heat sink to cool the heat generated by various facilities. Owing to the high corrosivity of seawater, facilities and piping made of metal material in contact with seawater are coated or lined with polymeric materials to avoid direct contact with seawater. However, polymeric materials used as coating and lining have some level of permeability to water and are degraded over time. Korean industrial plants have also experienced a gradual increase in the frequency of damage to pipes in seawater systems due to prolonged operating periods. In the event of a cavitation-like phenomenon, coating or lining inside the piping is likely to be damaged faster than expected. In this paper, the cause of water leakage due to base metal damage caused by the failure of the polyester lining in seawater system piping was assessed and the experience with establishing countermeasures to prevent such damage was described.

Detection of Inflow Permeable Zones Using Fluid Replacement Conductivity Logging in Coastal Aquifer (공내수 치환 전기전도도검층을 이용한 연안지역 대수층의 탐지)

  • Hwang, Se-Ho;Park, Yun-Seong;Shin, Je-Hyun;Park, Kwon-Gyu
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • Fluid replacement and conductivity logging have been applied to three boreholes in coastal aquifer in order to identify permeable fractures and to estimate the origin of saline groundwater. Fluid replacement technique measures and monitors the change of borehole fluid conductivity with depth under ambient or pumping condition after replacing the original borehole fluid with different one (by pumping out original one and injecting simultaneously new one at the hole bottom). After the replacement of borehole fluid, the change of fluid conductivity can be the direct indicator of the intake flow of formation water through aquifer such as permeable fractures or porous formations. The conductivity profiles measured with times therefore indicate the locations of permeable zone or fractures within the open hole or the fully slotted casing hole. As a result of fluid conductivity logging for three boreholes at coastal area in Yeonggwang, Jeonam Province, it is interpreted that the seawater intrusion in this area is not by remnant saline groundwater after land reclamation but mainly by intrusion of saline water through fractured rock. This approach might be useful for assessing the characteristics of seawater intrusion, the design of optimal pumping, the mitigation of seawater intrusion using freshwater injection, and estimating the hydraulic characteristics in coastal aquifer.

Adaptive digital control system of flow rates for an OTEC plant

  • Nakamura, Masatoshi;Uehara, Haruo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10a
    • /
    • pp.753-758
    • /
    • 1987
  • The purpose of ocean thermal energy conversion (OTEC) plant control is to provide stable power efficiently by appropriately regulating the seawater flow rates and the working fluid flow rate under conditions of continually changing seawater temperatures. This paper describes digital control of working fluid flow rate based on an adaptive control theory for the "Imari 2" OTEC plant at Saga University. Provisions have been made for linkage between the software of the adaptive control theory and the hardware of the OTEC plant. In implementing the working fluid flow rate control, if persistency of excitation conditions are lost, the algorithm of identification often exhibits bursting phenomena. To avoid this difficulty, the stopping-and-starting rule for identification was derived and was used for the working fluid flow rate control. Satisfactory control performance was then obtained by using this digital control system.ol system.

  • PDF

A Study on Seawater Flow Characteristics inside the Shrouds used in Tidal Current Generation Systems for Various Geometric Angles under Constant Tidal Current Velocity (조류발전 시스템용 쉬라우드의 형상각도별 일정 조류속도장 내 해수유동 특성연구)

  • Kim, Jong-Won;Lee, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.24 no.2
    • /
    • pp.77-83
    • /
    • 2012
  • Numerical analyses through Computational Fluid Dynamics have been performed to investigate the seawater flow field characteristics for various shrouds used in horizontal axis tidal current turbine systems. Seawater flow characteristics are largely influenced under constant tidal current velocity by the shroud geometry and there is considerable difference in fluid velocity distributions around the shrouds. Especially the location and magnitude of maximum seawater flow velocity directly affect turbine performance for power generation. For the cylinder-diffuser type shroud system whose cylinder and diffuser parts have the same length accelerated flow region is formed in the overall cylinder part while maximum velocity in the nozzle-diffuser type whose nozzle and diffuser parts have the same length with symmetry, locally appears near the minimum sectional area. In case of cylinder-diffuser type shroud fluid velocity increases rather high compared with current velocity. And fluid velocity at the centerline gradually increases from the entrance, and then decreases rapidly after reaching a peak close to the middle of the cylinder part unlike the nozzle-diffuser while there is not much variation near the rear of the shroud. These results of the seawater flow characteristics with various shroud geometries can be applied to optimal design for the development of efficient tidal current power generation systems.

Studies on the Seedling Production of the Freshwater Crab, Eriocheir japonicus (De Haan) 3. Physiological Study of Osmolarity of the Body Fluid and Oxygen Consumption of the Larvae (동남참게, Eriocheir japonicus(De Haan)의 종묘생산에 관한 생물학적 기초연구 3. 유생의 체액 삼투질 농도 및 산소 소비에 관한 생리학적 연구)

  • LEE Bok-Kyu;KWON Chin-Soo
    • Journal of Aquaculture
    • /
    • v.6 no.4
    • /
    • pp.273-284
    • /
    • 1993
  • Ion concentrations and osmolarities of the body fluid and oxygen consumption of the larvae of the freshwater crab, Eriocheir japonicus under the influence of various salinities and water temperatures were studied. The levels of $Na^+\;and\;Cl^-$ ions in the body fluid of the crab placed in the low salinities (freshwater and $30\%$ seawater) were higher at the low temperature $(16^{\circ}C)$ than high temperature $(30^{\circ}C)$. However, the crab in the high salinity $(90\%\; seawater)$, those ions in the body fluid were higher at the high temperature $(30^{\circ}C)$ than the low temperature $(10^{\circ}C)$ When the zoea larvae were young (first and second stages), the ion concentrations of the body fluid were more affected by salinities and temperatures of the media. The salinity levels of the media more influenced the levels of $K^+$ ions of the body fluid of the larvae than the temperature. The osmolarities of the body fluid of the larvae were almost isotonic when they were placed at $70\%$ seawater $(24.5\%o)$. Oxygen consumption of individual larva was lower in zoea 1 and 2 stages than the other stage larvae. The high oxygen consumption of the larvae was observed at $70\%$ seawater compared to the other salinity levels.

  • PDF

An Experimental Study on the Dispersion Characteristics of Seawater Injection Nozzle for Hull Cooling (선체냉각을 위한 해수분사노즐의 산포특성에 관한 실험 연구)

  • Yoon, Seoktae;Jung, Hoseok;Cho, Yongjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.767-773
    • /
    • 2017
  • Infrared stealth is an important technology for naval ships. This technology helps improve the anti-detection performance and survivability of naval ships. In general, the infrared signature of naval ships are categorized into internal and external heat source. External signature are generated by ship surface heating by solar flux as well as the complicated heat transfer process with the surrounding weather condition. Modern naval ships are equipped with seawater injection nozzles on the outside for nuclear, biological and, chemical, and these nozzles are used to control external signature. Wide nozzle placement intervals and insufficient injection pressure, however, have reduced seawater dispersion area. To address this problem, nozzle installation standards must be established. In this study, an actual-scale experimental system was implemented to provide the evidence for nozzle installation standards in order to reduce the infrared signature of naval ships. In addition, the environmental conditions of the experiment were set up through computational fluid dynamics considering the ocean climate data and naval ship management conditions of South Korea. The dispersion distance was measured using a high-resolution thermography system. The flow rate, pipe pressure, and dispersion distance were analyzed, and the evidence for the installation of seawater injection nozzles and operation performance standards was suggested.