• 제목/요약/키워드: Seating Using Statement

검색결과 2건 처리시간 0.013초

대학 강의실 좌석이용형태에 관한 연구 (A Study on Preference of Lecture Room by Seating Layout)

  • 소갑수;박민혁;김승제
    • 교육시설 논문지
    • /
    • 제20권4호
    • /
    • pp.3-10
    • /
    • 2013
  • Basic precondition for effective curriculum on learning activities to take place, the internal and external environment of the school facilities, improve the environment of the classroom space and etc. Specifically, the use of classroom space, hardly learners improve their academic motivation to achievement tend to concentrate within the party regularly scheduled class hours. Physical environment surrounding them is giving considerable impact for behavioral psychological and bodily change of the learners. In this study, we are focused on the form of the learner in the general classroom space and classroom environment that can increase the learning effect will be examined. Consequently, What is appropriate classroom environment for learning increase the concentration of elements are presented.

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF