• Title/Summary/Keyword: Se/metal ratio

Search Result 54, Processing Time 0.026 seconds

Deposition of CuInSe2 Thin Films Using Stable Copper and Indium-selenide Precursors through Two-stage MOCVD Method

  • Park, Jong-Pil;Kim, Sin-Kyu;Park, Jae-Young;Ok, Kang-Min;Shim, Il-Wun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.853-856
    • /
    • 2009
  • Highly polycrystalline copper indium diselenide (CuInSe2, CIS) thin films were deposited on glass or ITO glass substrates by two-stage metal organic chemical vapor deposition (MOCVD) at relatively mild conditions, using Cuand In/Se-containing precursors. First, pure Cu thin film was prepared on glass or ITO glass substrates by using a single-source precursor, bis(ethylbutyrylacetate)copper(II) or bis(ethylisobutyrylacetato)copper(II). Second, on the resulting Cu films, tris(N,N-ethylbutyldiselenocarbamato)indium(III) was treated to produce CuInSe2 films by MOCVD method at 400 ${^{\circ}C}$. These precursors are very stable in ambient conditions. In our process, it was quite easy to obtain high quality CIS thin films with less impurities and uniform thickness. Also, it was found that it is easy to control the stoichiometric ratio of relevant elements on demands, leading to Cu or In rich CIS thin films. These CIS films were analyzed by XRD, SEM, EDX, and Near-IR spectroscopy. The optical band gap of the stoichiometric CIS films was about 1.06 eV, which is within an optimal range for harvesting solar radiation energy.

Drilling Properties of Water-Based Metal Working Fluid Containing Fatty Acid and Polyethylene Glycol (지방산과 폴리에틸렌글리콜의 혼합에 따른 수용성 절삭유제의 절삭특성)

  • Kim, Yeong-Un;Jeong, Geun-U;Yun, Yu-Jeong;Kim, Se-Hun;Gang, Seok-Chun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.161-170
    • /
    • 2001
  • Synthetic water-based metal-cutting fluids are increasingly popular in the metal-working industry because of its environmental friendliness. The propose of this study is to investigate the synergistic effect of combining polyethylene glycol and common fatty acid in formulating a metal-cutting fluid. The tested metals were aluminum, copper and steel, and the test was performed with a modified drilling machine. From the study, it was found that there existed some synergistic effects on the drilling efficiency of the metals to decrease of cutting time, cutting energy, torque as well as the smoothness of surface depended on the formulation ratio of the two fluids.

  • PDF

Mechanical and Durability Characteristics of Amorphous Metallic Fiber Reinforced Self-Healing Mortar (비정질금속섬유 보강 자기치유 모르타르의 역학 및 내구특성)

  • Yoon, Joo-Ho;Lee, Min-Wook;Kim, Chae-Young;Lee, Jae-In;Choi, Se-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.27-28
    • /
    • 2023
  • This study compared and analyzed the fluidity, compressive strength, and carbonation resistacne of amorphous metal fiber reinforced mortar according to the PCC mixing ratio as part of a study to improve the self-healing performance and tensile performance of concrete structures.

  • PDF

Characteristics of Strengthening for Thin Metals by Laser Beam (레이저 빔에 의한 박판금속의 강화특성)

  • Yang, Se-Young;Choi, Seong-Dae;Kim, Gi-Man;Jun, Jea-Mok;Gong, Byeong-Chae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.2
    • /
    • pp.216-223
    • /
    • 2010
  • The general way to process the surface by means of the laser was heat treatment for strengthening the surface hardness. They have used the laser for changing the property of the surface, especially for metal. Generally, it is recent increasing tendency to use the thin plate panel for making things smaller and lightweight. However, thin plate should be strengthened or let the thin plate panel have moment of inertia by means of engraving the groove or wave on them for lightweight and strengthening. Therefore it is expected that the thin plate panel can be harder and more stable through processing the metal surface by laser beam irradiation and the hardness of thin plate possibly can be also changed how many parts of them are harden. Through this research, it can be grasped how the hardness and mechanical characteristic changes according to width and depth of groove by laser affect the max stress by the ratio of $A_H/A_T$ (hardening area/total area) and characteristic of displacement and structural characteristic for making the thin plate harder by the strengthening metal surface of thin plate by laser through the experiment and analysis of FEA can be presented.

A Study of Thermal Sensor Using Chalcogenide Classy Semiconductor (칼코게나이드 유리반도체를 이용한 온도센서에 관한 연구)

  • 임석범;임동준;양준모;김영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.439-442
    • /
    • 2001
  • Chalcogenide glassy semiconductors(CGS) can be obtained by the melt quenching technique. We have investigated the thin film heterostructures : metal-chalcogenide glassy semiconductors, where metal is copper, and chalcogenide glassy semiconductors are glasses of the system As-Se. CU/CGS film heterostructure were produced in the vacuum evaporator by the method of vacuum thermal evaporation. Doped films are very sensitive to external actions, and this property allows developing supersensitive precision sensors of temperature, humidity, illumination, and etc. based on them. Cu/CGS film has shown that resistance strongly depend on the temperature. The ratio of resistance vs. temperature has shown over a 2 k$\Omega$/degree. The slop of temperature and resistance shows linear.

  • PDF

Dielectric Characteristics of Carbon Nitride Films on Quartz Substrate (석영기판에 증착된 질화탄소막의 유전특성)

  • Ha, Se-Geun;Lee, Ji-Gong;Lee, Sung-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.872-875
    • /
    • 2003
  • Carbon nitride($CN_x$) thin films were deposited on quartz substrates using reactive RF magnetron sputtering system at uarious deposition conditions and investigated dielectric characteristics. Samples for capacitance measurements were of the MIM(Metal-Insulator-Metal) type devices. Aluminum film electrodes were prepared by a vacuum thermal evaporation method before and after the deposition of carbon nitride films. Capacitances were measured by a FLUKE PM6306 RCL Meter at room temperature. Current-voltage(I-V) characteristics and resistivity were measured by a CATS CA-EDA semiconductor test and analyzer. The carbon nitride films showed ${\alpha}-C_3N_4$ and ${\beta}-C_3N_4$ etc. peaks through Raman and FTIR. Observed surface of film and side structure using SEM(Scanning Electron Microscope), and measured thickness of film by ${\alpha}-step$. We can find that the dielectric constant was the lowest value in 50% nitrogen ratio and the resistivity was the highest value in 70% nitrogen ratio.

  • PDF

Characteristics of CIGS film fabricated by non-vacuum process (비 진공으로 제작한 CIGS 박막 특성)

  • Park, Myoung-Guk;Ahn, Se-Jin;Yoon, Jea-Ho;Gwak, Ji-Hye;Kim, Dong-Hwan;Yoon, Kyung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.19-22
    • /
    • 2009
  • A non-vacuum process for fabrication of $CuIn_xGa_{1-x}Se_2$ (CIGS) absorber layer from the corresponing Cu, In, Ga solution precursors was described. Cu, In, Ga precursor solution was prepared by a room temperature colloidal route by reacting the starting materials $Cu(NO_3)_2$, $InCl_3$, $Ga(NO_3)$ and methanol. The Cu, In, Ga precursor solution was mixed with ethylcellulose as organic binder material for the rheology of the mixture to be adjusted for the doctor blade method. After depositing the mixture of Cu, In, Ga solution with binder on Mo/glass substrate, the samples were preheated on the hot plate in air to evaporate remaining solvents and to burn the organic binder material. Subsequently, the resultant CIG/Mo/glass sample was selenized in Se evaporation in order to get a solar cell applicable dense CIGS absorber layer. The CIGS absorber layer selenized at $530^{\circ}C$ substrate temperature for 1h with various metal organic ratio.

  • PDF

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

AN EXPLORATORY STUDY COMPARING BLOOD METAL CONCENTRATIONS BETWEEN STROKE AND NON-STROKE PATIENTS IN KOREANS

  • Lee, Sun-Dong;Ko, Seong-Gyu;Kim, Rok-Ho;Hu, Howard;Amarasiriwardena, Chitra J.;Park, Hae-Mo
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.12a
    • /
    • pp.87-94
    • /
    • 2005
  • Results from previous studies revealed that metal level in the body is related to certain types of diseases. For example. serum copper level with chronic heart failure, iron and transferrin in the blood serum with acute cerebral vascular diseases, Zn in the CNS, lead with neurotoxicity, hypertension, genetic damage, arsenic with cancer skin lesion, Al with neurobehavioral function (cognitive impairment and memory disorder), and etc. The rate of stroke has increased in recent years and several metals were found to be responsible for causing stroke. This study compared several blood metal concentrations between stroke and non-stroke patients. Patients with stroke (116 samples) and non-stroke (111 samples including lowback pain and others) participated in this study. Total of 227 blood samples were collected and participants completed questionnaires regarding age, gender, occupation, residence, alcohol, smoking, and etc. To be qualified into the stroke group, patients have never experienced stroke previously. Subjects only included ischemic stroke and intracerebral hemorrhage patients diagnosed by brain CT and brain MRI. Patients with high risk of metal exposure such as herbal intake and job related exposure were excluded. 10ml of blood samples were analyzed by ICP-MS method at the Center of Nature and Science at Sangji University. Metal geometric mean (SD) concentrations in blood of study subjects showed higher values, 2.64-36.12%, than WHO reference values in Mn, Ni, Hg, Se, and As. Metal concentration in blood of stroke patients non-adjusted for potential confounders was higher except for Hg and also higher except for Ni in adjusted for potential confounders. Co was significantly higher in stroke patients (p=0.002) than non-stroke patients adjusted for potential confounders. Regression coefficient values of stroke patients was 0.17-8.25 in each metals. Odd ratio of stroke patients had 0.96 (Ni)-2.68 (Co) compared to non-stroke cases. This result means that Co increase of 1 raises the risk ratio of stroke by 2.86 times. Based on the results, metal concentration in blood seems to affect incidence of stroke.

  • PDF

Assessment of Soil Pollutant Distribution Characteristics and Heavy Metal Pollution in Korea (국내 토양오염물질 분포 특성 및 중금속 오염도 평가)

  • Lee, Jong Cheol;Kang, Min Woo;Choi, Gyu Hyuk;Oh, Se Jin;Kim, Dong Jin;Lee, Sang Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • BACKGROUND: Heavy metals discharged from various sources contaminate the soil and water and the residuals can persistently be accumulated. In this study, the concentration of soil heavy metals was assessed over the whole regions of Korea based on the contamination factor and the geoaccumulation index. METHODS AND RESULTS: The data of averaged concentrations of heavy metals and fluorine were collected from the Korean Statistical Information Service (KOSIS) and the research papers published. In order to classify the levels of heavy metal concentration, the contamination index, including the contamination factor and the geoaccumulation index, based on the relative ratio of the actual concentration of heavy metals in the soil to the background concentration was calculated. In addition, the distribution of heavy metals in soils was visualized by using the geographic information system (GIS). As a result, the Cd contamination in the soils was the most concerned. CONCLUSION(S): This study very roughly indicated the outline of heavy metal concentration over the whole regions of Korea. The change in heavy metals' concentration over the time should further be monitored and the larger data of heavy metal contamination are needed for better understanding in the future.