• Title/Summary/Keyword: Screws

Search Result 645, Processing Time 0.023 seconds

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

Fatigue fracture of different dental implant system under cyclic loading (반복하중에 따른 수종 임플란트의 피로파절에 관한 연구)

  • Park, Won-Ju;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.424-434
    • /
    • 2009
  • Statement of problem: Problems such as loosening and fractures of retained screws and fracture of implant fixture have been frequently reported in implant prosthesis. Purpose: Implant has weak mechanical properties against lateral loading compared to vertical occlusal loading, and therefore, stress analysis of implant fixture depending on its material and geometric features is needed. Material and methods: Total 28 of external hexed implants were divided into 7 of 4 groups; Group A (3i, FULL $OSSEOTITE^{(R)}$Implant), Group B (Nobelbiocare, $Br{\aa}nemark$ $System^{(R)}$Mk III Groovy RP), Group C (Neobiotec, $SinusQuick^{TM}$ EB), Group D (Osstem, US-II). The type III gold alloy prostheses were fabricated using adequate UCLA gold abutments. Fixture, abutment screw, and abutment were connected and cross-sectioned vertically. Hardness test was conducted using MXT-$\alpha$. For fatigue fracture test, with MTS 810, the specimens were loaded to the extent of 60-600 N until fracture occurred. The fracture pattern of abutment screw and fixture was observed under scanning electron microscope. A comparative study of stress distribution and fracture area of abutment screw and fixture was carried out through finite element analysis Results: 1. In Vicker's hardness test of abutment screw, the highest value was measured in group A and lowest value was measured in group D. 2. In all implant groups, implant fixture fractures occurred mainly at the 3-4th fixture thread valley where tensile stress was concentrated. When the fatigue life was compared, significant difference was found between the group A, B, C and D (P<.05). 3. The fracture patterns of group B and group D showed complex failure type, a fracture behavior including transverse and longitudinal failure patterns in both fixture and abutment screw. In Group A and C, however, the transverse failure of fixture was only observed. 4. The finite element analysis infers that a fatigue crack started at the fixture surface. Conclusion: The maximum tensile stress was found in the implant fixture at the level of cortical bone. The fatigue fracture occurred when the dead space of implant fixture coincides with jig surface where the maximum tensile stress was generated. To increase implant durability, prevention of surrounding bone resorption is important. However, if the bone resorption progresses to the level of dead space, the frequency of implant fracture would increase. Thus, proper management is needed.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Clinical and Radiological Outcomes of 'Blocking Kirschner Wire Technique' in Displaced Intra-Articular Calcaneal Fractures via the Extended Sinus Tarsi Approach (전위된 관절 내 종골 골절에서 확장된 족근동 접근법을 통한 Kirschner Wire 강선 지지대 고정술의 임상 및 영상학적 결과)

  • Lee, Jeong-Kil;Kang, Chan;Kim, Sang-Bum;Lee, Gi-Soo;Hwang, Jung-Mo;An, Byung-Kuk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.224-233
    • /
    • 2021
  • Purpose: The purpose of this study was to retrospectively evaluate the effect of 'Blocking Kirschner Wire (K-Wire) Technique', which has been developed to reduce protrusion of the lateral wall, in maintaining the level of reduction through clinical and radiological outcomes. Materials and Methods: Twenty-two patients with displaced intra-articular calcaneal fractures who used the blocking K-wire to maintain reduction (group A) and 44 patients that did not use blocking K-wire and were paired in 1:2 ratio with those Group A patients (group B), between January 2015 and December 2017 were enrolled in the study. All surgical procedures were performed via the extended sinus tarsi approach, and internal fixation using cannulated screws, Steinmann pins and K-wires was performed. American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot scale and postoperative recovery of exercise ability were compared for postoperative clinical outcomes. The radiological results were compared the Böhler angle, Gissane angle, calcaneal height and width, step off of posterior calcaneal joint, and the degree of protrusion of the lateral wall. Moreover, postoperative complications in both groups were compared. Results: There were no significant differences in the clinical outcomes of the two groups (p=0.924, p=0.961). The amount of Böhler angle, Gissane angle, calcaneal height and width, and step off of posterior calcaneal joint from the radiological results was not significantly different between the two groups (p=0.170, p=0.441, p=0.230, p=0.266, and p=0.400). However, the degree of protrusion of the lateral wall was 1.78 mm and 4.95 mm in group A and group B, respectively, and the difference between the two groups was significant (p=0.017). Although sural nerve entrapment and painful exostosis were more frequent in group B, they were occurred in a non-significant manner (p=0.293, p=0.655). Conclusion: Most of the clinical and radiological results as well as the complications were not significantly different between the two groups. However, the degree of protrusion of the calcaneus lateral wall in group A was promising. The 'Blocking K-Wires Technique' established by the authors may be an effective surgical option for maintaining the reduction of the lateral wall protrusion in displaced intraarticular calcaneal fractures.

Arthroscopically-Assisted Reduction and Internal Fixation of Intra-Articular Fractures of the Lateral Tibial Plateau (관절면을 침범한 경골 외측 고평부 골절에 대한 관절경을 이용한 정복 및 내고정술)

  • Kim, Juhan;Kim, Dong Hwi;Lim, Jae-Hwan;Jang, Hyunwoong;Kim, Young Wook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.227-236
    • /
    • 2019
  • Purpose: To evaluate the results of tibial lateral plateau fractures using arthroscopic-assisted reduction and internal fixation without cortical window or bone grafts. Materials and Methods: From March 2009 to March 2017, 27 patients with Schatzker type II tibial plateau fractures with articular depression and displacement over 5 mm on a computed tomography (CT) scan, who were treated with arthroscopic reduction and internal fixation and followed-up for at least 18 months, were enrolled in this study. Under arthroscopic guidance, the depressed fracture fragment was reduced using a freer and fixed with 5.0 or 6.5 mm cannulated screws through the inframeniscal portal without a cortical window or bone graft. The clinical and radiological results were evaluated using a Rasmussen system. Second look arthroscopy was performed in thirteen patients during the implant removal operation. Results: All fractures healed completely with a mean union time of 8.7 weeks (range from 8 to 12 weeks). Twenty four patients had good to excellent clinical results and 25 patients had good to excellent radiological results according to the Rasmussen classification. A well-healed articular surface with fibrocartilage was also found in 13 cases with second look arthroscopy. The 8 cases on CT scan at outpatient department follow-up showed bone union without bone grafting. Conclusion: Arthroscopic-assisted fixation of tibial lateral plateau fractures is a useful method without a cortical window or bone graft that produces good clinical results.