• Title/Summary/Keyword: Screws

Search Result 645, Processing Time 0.023 seconds

Effects of grooved abutment on stability of implant abutment screw (Grooved abutment가 임플란트 지대주 연결나사의 안정성에 미치는 영향)

  • Sim, Il-Gwang;Yang, Seung-Won;Shim, June-Sung;Kim, Jee-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.387-392
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the effects of grooved abutments on abutment screw loosening. Materials and methods: This study was conducted to evaluate the abutment screw loosening after 6 months for 50 patients (51 implants) treated at the department of Prosthodontics in Yonsei University Dental Hospital from March, 2015 to July, 2015. A control group with non-grooved abutment consists of 30 implants, and an experimental group with grooved abutment consists of 21 implants. Astra, Straumann, Implantium, Osstem system were used in the study. The abutments with loose screws cases after a period of 6 months has been investigated, with two kinds of measurements: 1) measuring the additional rotational angle on abutment during placement with the same force, 2) measuring the PTV on bucco-cervical area of implant crown. All data collected has been analyzed by normality test followed by Mann-Whitney test using SPSS program. Results: No complications were reported after 6 months for the 51 implants. Abutment screw loose and crown fracture have not been seen in the study groups. The data collected from the two measurements showed no significant differences between the two groups with P-value 0.576 (average= control group: $7.35^{\circ}$, experimental group: $4.75^{\circ}$) for the additional rotational angle measurement and with P-value 0.767 for PTV. Conclusion: There are no significant differences between the grooved and non-grooved abutment in screw stability. However, further studies with long-term followups and larger group of patients is needed in order to investigate the effects of grooved abutment on screw stability.

MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE (교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가)

  • Kweon, Young-Sun;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • The aim of this study was to suggest a design for an orthodontic miniscrew which may work most favorably in the thin cortical bone of the adolescent. In this study, orthodontic miniscrews with different diameters, lengths, and body types were manufactured and implanted in two artificial bone samples with different cortical bone thickness. Maximum insertion torque, maximum removal torque, and lateral alteration torque were measured. As a result, the bone quality, body type, diameter, and the length all had their effects on the maximum insertion torque, maximum removal torque, and lateral alteration torque. Cortical bone thickness was the most important factor. In initial stability, conical types showed better results than cylindrical types. Increase in the diameter had favorable effects in achieving mechanical stability. Increase in the length did not have as much influence as the other factors did on the initial stability, but there was a statistically significant difference between screws of 6 mm and 8 mm lengths(p<0.05). In conclusion, the conical type screw with a diameter of 1.8 mm is most favorable in the thin cortical bone of the adolescent. In terms of length, the 8 mm screw is expected to perform better than the 6 mm screw.

Intercalary Tricortical Iliac Bone Graft in the Surgical Treatment of Nonunion of Midshaft Clavicular Fractures (쇄골 간부 불유합에서의 개재 삼면피질 장골 이식술)

  • Cho, Chul-Hyun;Jang, Hyung-Gyu
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.32-36
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the radiologic and clinical outcomes after intercalary tricortical iliac bone graft with plate fixation for the nonunion of midshaft clavicular fractures. Material and Methods: Between September 2007 and May 2011, 10 patients who were treated by the intercalary tricortical iliac bone graft, with plate fixation for clavicle nonunion, were studied. The mean follow-up period was 30.7 (12~57) months. After the sclerotic bone was excised to the bleeding cortical bone, we interposed the tricortical iliac bone to provide structural support and restore clavicle length, and then fixed the plate and screws. The radiologic outcomes on the serial plain radiographs and clinical outcomes, according to UCLA, ASES and Quick DASH scores, were analyzed. Results: Bony union was obtained in all cases (100%) and the average union time was 18.4 (14~24) weeks. The average respective UCLA and ASES scores improved from 16.7 and 52.1 preoperatively to 27.4 and 83.6 postoperatively (p<0.05). The average Quick DASH score was 40.5, at the final follow-up. Complications were 2 shoulder stiffness, and one case had removal of device and arthroscopic surgery at 11 months, postoperatively. There were no implant failure or infection. Conclusion: Intercalary tricortical iliac bone graft, with plate fixation for the nonunion of midshaft clavicular fractures, is a good option that can provide structural support and restore clavicle length, as well as high union rate.

Treatment of Open Proximal Humerus Fracture by Gunshot (총격에 의한 개방성 근위 상완골 골절의 치료 - 증례 보고 -)

  • Kim, Sung-Jae;Lee, Jae-Hoo;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Purpose: To consider the proper management of proximal humerus fracture on gunshot wounds. Materials and Methods: A 28-year-old male patient, who sustained a gunshot injury on the left arm 5 days ago, was admitted through the emergency department. Although he underwent an emergency surgery (bullet fragment removal and debridement), there remained bullet fragments around the proximal humerus fracture site. The wound seemed to be infected and a partial dehiscence occurred. No neurologic deficit was noted. Immediate exploration and debridement were performed, and an external fixator was applied to restore the anatomical alignment and manage the wounds. Intravenous antibiotics were administered. On the 9th postoperative day, wound debridement was done again, and cement beads mixed with antibiotics were inserted. After two weeks, the external fixator was removed, and the pin sites were closed after debridement. One week later, the open reduction and internal fixation with locking compression plate and screws were done. Result: At 3 months after the internal fixation, the bone union was obtained with satisfactory alignment of the humerus. Conclusion: The severity of the soft tissue injury influences the fracture management plan. Further, the risk on lead toxicity should be considered.

Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants (임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향)

  • Yun, Bo-Hyeok;Shin, Hyon-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Kang, Eun-Sook
    • The Journal of the Korean dental association
    • /
    • v.53 no.9
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

Long-term clinical and experimental/surface analytical studies of carbon/carbon maxillofacial implants

  • Szabo, Gyorgy;Barabas, Jozsef;Bogdan, Sandor;Nemeth, Zsolt;Sebok, Bela;Kiss, Gabor
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.34.1-34.14
    • /
    • 2015
  • Background: Over the past 30-40 years, various carbon implant materials have become more interesting, because they are well accepted by the biological environment. The traditional carbon-based polymers give rise to many complications. The polymer complication may be eliminated through carbon fibres bound by pyrocarbon (carbon/carbon). The aim of this study is to present the long-term clinical results of carbon/carbon implants, and the results of the scanning electron microscope and energy dispersive spectrometer investigation of an implant retrieved from the human body after 8 years. Methods: Mandibular reconstruction (8-10 years ago) was performed with pure (99.99 %) carbon implants in 16 patients (10 malignant tumours, 4 large cystic lesions and 2 augmentative processes). The long-term effect of the human body on the carbon/carbon implant was investigated by comparing the structure, the surface morphology and the composition of an implant retrieved after 8 years to a sterilized, but not implanted one. Results: Of the 16 patients, the implants had to be removed earlier in 5 patients because of the defect that arose on the oral mucosa above the carbon plates. During the long-term follow-up, plate fracture, loosening of the screws, infection or inflammations around the carbon/carbon implants were not observed. The thickness of the carbon fibres constituting the implants did not change during the 8-year period, the surface of the implant retrieved was covered with a thin surface layer not present on the unimplanted implant. The composition of this layer is identical to the composition of the underlying carbon fibres. Residual soft tissue penetrating the bulk material between the carbon fibre bunches was found on the retrieved implant indicating the importance of the surface morphology in tissue growth and adhering implants. Conclusions: The surface morphology and the structure were not changed after 8 years. The two main components of the implant retrieved from the human body are still carbon and oxygen, but the amount of oxygen is 3-4 times higher than on the surface of the reference implant, which can be attributed to the oxidative effect of the human body, consequently in the integration and biocompatibility of the implant. The clinical conclusion is that if the soft part cover is appropriate, the carbon implants are cosmetically and functionally more suitable than titanium plates.

Feasibility of Bilateral Crossing C7 Intralaminar Screws : A Cadaveric Study

  • Baek, Tae-Hyun;Kim, Ilsup;Hong, Jae-Taek;Kim, Daniel H.;Shin, Dongsuk;Lee, Sang-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.1
    • /
    • pp.5-10
    • /
    • 2014
  • Objective : When the pedicle screw insertion technique is failed or not applicable, C7 intralaminar screw insertion method has been used as an alternative or salvage fixation method recently. However, profound understanding of anatomy is required for safe application of the bilaterally crossing laminar screw at C7 in clinic. In this cadaveric study, we evaluated the anatomic feasibility of the bilateral crossing intralaminar screw insertion and especially focused on determination of proper screw entry point. Methods : The C7 vertebrae from 18 adult specimens were studied. Morphometric measurements of the mid-laminar height, the minimum laminar thickness, the maximal screw length, and spino-laminar angle were performed and cross-sectioned vertically at the screw entry point (spino-laminar junction). The sectioned surface was equally divided into 3 parts and maximal thickness and surface area of the parts were measured. All measurements were obtained bilaterally. Results : The mean mid-laminar height was 13.7 mm, mean minimal laminar thickness was 6.6 mm, mean maximal screw length was 24.6 mm, and mean spinolaminar angle was $50.8{\pm}4.7^{\circ}$. Based on the measured laminar thickness, the feasibility of 3.5 mm diameter intralaminar screw application was 83.3% (30 sides laminae out of total 36) when assuming a tolerance of 1 mm on each side. Cross-sectional measurement results showed that the mean maximal thickness of upper, middle, and lower thirds was 5.0 mm, 7.5 mm, and 7.3 mm, respectively, and mean surface area for each part was $21.2mm^2$, $46.8mm^2$, and $34.7mm^2$, respectively. Fourteen (38.9%) sides of laminae would be feasible for 3.5 mm intralaminar screw insertion when upper thirds of C7 spino-laminar junction is the screw entry point. In case of middle and lower thirds of C7 spino-laminar junction, 32 (88.9%) and 28 (77.8%) sides of laminae were feasible for 3.5 mm screw insertion, respectively. Conclusion : The vertical cross-sectioned area of middle thirds at C7 spinolaminar junction was the largest area and 3.5 mm screw can be accommodated with 77.8 % of feasibility when lower thirds were the screw entry point. Thus, selection of middle and lower thirds for each side of screw entry point in spino-laminar junction would be the safest way to place bilateral crossing laminar screw within the entire lamina. This anatomic study result will help surgeons to place the screw safely and accurately.

The Design of an Auto Tuning PI Controller using a Parameter Estimation Method for the Linear BLDC Motor (선형 추진 BLDC 모터에 대한 파라미터 추정 기법을 이용하는 오토 튜닝(Auto Tuning) PI 제어기 설계)

  • Cha Young-Bum;Song Do-Ho;Koo Bon-Min;Park Moo-Yurl;Kim Jin-Ae;Choi Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.4
    • /
    • pp.659-666
    • /
    • 2006
  • Servo-motors are used as key components of automated system by performing precise motion control as accurate positioning and accurate speed regulation in response to the commands from computers and sensors. Especially, the linear brushless servo-motors have numerous advantages over the rotary servo motors which have connection with the friction induced transfer mechanism such as ball screws, timing belts, rack/pinion. This paper proposes an estimation method of unknown motor system parameters using the informations from the sinusoidal driving type linear brushless DC motor dynamics and outputs. The estimated parameters can be used to tune the controller gain and a disturbance observer. In order to meet this purpose high performance Digital Signal Processor, TMS320F240, designed originally for implementation of a Field Oriented Control(FOC) technology is adopted as a controller of the liner BLDC servo motor. Having A/D converters, PWM generators, rich I/O port internally, this servo motor application specific DSP play an important role in servo motor controller. This linear BLDC servo motor system also contains IPM(Intelligent Power Module) driver and hail sensor type current sensor module, photocoupler module for isolation of gate signals and fault signals.

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Augmentation of Pyriform Margin Using Porous High-Density Polyethylene Sheet In Unilateral Cleft Lip Nasal Deformity (일측성 구순열비변형에서 다공성 폴리에틸렌 판을 이용한 상악골이상구증대술)

  • Han, Ki Hwan;Kim, Jin Han;Choi, Tae Hyun;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.431-438
    • /
    • 2008
  • Purpose: The common deformity after the correction of unilateral cleft lip nasal deformity is nasal asymmetry, and it is caused by the hypoplasia of the pyriform aperture. To correct this, many procedures have been applied, but still many problems are present. Authors performed the inlay and onlay insertion of porous high density polyethylene sheet(1 mm thickness $Medpor{(R)}$ sheet) in the hypoplastic pyriform margin of cleft side and obtained satisfactory results. Methods: 11 cases were performed and the mean follow up period was 15.1 months. Their mean age was 23.6 years. Under general anesthesia, bilateral pyriform margin was exposed. $Medpor{(R)}$ sheets in "match stick" like shaped were inlay inserted, and kidney shaped were onlay inserted fixating with two 6 mm titanium screws. After the surgery, the results was evaluated by photogrammetric analysis. On the basal view, the distance from the subalare and labiale superius' to the transverse baseline connecting the both cheilions was measured from the cleft side and the non-cleft side. Then, the postoperative symmetry was assessed by obtaining the cleft side against the non-cleft side as proportion index, defined as lateral and medial upper lip contour index. Results: There were 2 infections. The cause was because the inserted implant was too long and thus protruded to the base of nasal cavity. The lateral upper lip contour index was from 95.49 to 103.27, and medial upper lip contour index was from 90.92 to 100.49, it was statistically increased, and thus the symmetry was improved. However clinically mild depression remained at nostril floor. Conclusion: Authors performed porous high density polyethylene sheet inlay and onlay insertion for the hypoplasia of the pyriform margin in unilateral cleft lip nasal deformity. It was found that depressed pyriform margin and upper lip were corrected effectively except for the nostril floor, for which an additional soft tissue augmentation would be necessary. The inlay insertion has risk of protrusion, thus the guideline of the use of artificial prosthesis should be observed strictly.