• 제목/요약/키워드: Screws

검색결과 645건 처리시간 0.033초

자가골 블럭 이식을 이용한 수평골 증강술시 이식골의 치유 (THE HISTOLOGIC STUDY OF BONE HEALING AFTER HORIZONTAL RIDGE AUGMENTATION USING AUTO BLOCK BONE GRAFT)

  • 오재권;최병준;이백수
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권3호
    • /
    • pp.207-215
    • /
    • 2009
  • Purpose: The aim of the present study is to evaluate the long term bone healing after horizontal ridge augmentation using auto block bone graft for implant installation timing. Materials and Methods: Five Beagle dogs(which were 14 months old and weighted approximately 10kg). In surgery 1(extraction & bone defect), premolars(P2, P3,P4) were extracted and the buccal bone plate was removed to create a horizontally defected ridge. After three months healing, in surgery 2(ridge augmentation). Auto block bone grafts from the mandibular ramus were used in filling the bone defects were fixed with stabilizing screws. The following fluorochrome labels were given intravenously to the beagle dogs: oxytetracycline 1week after the surgery, alizarin red 4 weeks after the surgery, calcein blue 8 weeks after the surgery. The tissue samples were obtained from the sacrificed dogs of 1, 4, 8, 12, 16 weeks after the surgery. Non-decalcified sections were prepared by resin embedding and microsection to find thickness of $10{\mu}m$ for the histologic examination and analysis. Results: 1. We could achieve the successful reconstruction of the horizontal bone defect by auto block bone graft. The grafted bone block remained stable morohologically after 16 weeks of the surgery. 2. In the histologic view. We observed osteoid tissue from the sample $4^{th}$ week sample and active capillary reconstruction in the grafted bone from the $12^{th}$ week sample. Healing procedures of auto bone grafts were compared to that of the host bone. 3. Bone mineralization could be detected from the $8^{th}$ week sample. 4. Fluorochrome labeling showed active bony changes and formation at the interface of the host bone and the block graft mainly. Bony activation in the grafted bone could be seen from the $4^{th}$ week samples. Conclusions: Active bone formation and remodeling between the grafted bone and host bone can be seen through the revascularization. After the perfect adhesion to host bone, Timing of successful implant installation can be detected through the ideal ridge formation by horizontal ridge augmentation.

제II급 치조 전돌 환자에서 설측 견인 장치를 이용한 급속 견치 견인술 (Rapid canine retraction in a Class II bialveolar protrusion case using a lingually extended distraction screw)

  • 안광석;주억;박주영;유영규;차인호;이기준
    • 대한치과교정학회지
    • /
    • 제36권4호
    • /
    • pp.308-320
    • /
    • 2006
  • 견인골 신장술의 개념을 치주인대 조직에 적용한 Liou의 급속 치아 이동 술식은 이동할 견치의 원심부 골 삭제에 의한 치조골 저항의 최소화 및 근심부의 치주조직 견인에 의한 골 형성으로 요약된다. 이는 주로 제1소구치 발치 후 견치의 견인을 요하는 환자들에 적용되어 효과적으로 치료 기간을 단축하고 양호한 결과를 얻을 수 있으나 견인 중 견치의 경사 및 정출 등 문제점이 발생하기 쉬우므로 견인이 완료될 때까지 치체이동을 유도하며 경로를 유지하는 것이 중요하다. 본 증례에서는 이러한 급속견인의 예측가능성을 높이기 위해 설측으로 연장된 견인스크류를 순측의 견고한 안내선과 병행 적용하였다. 발치 직후 미리 제작된 견치 치근 모델을 적용하여 발치와의 깊이를 형성하고 또한 교정용 미니스크류 임플란트를 이용하여 고정원을 보강하였다. 이러한 방법을 적용하여 골격성 II급 관계 및 전치 돌출을 보이는 성인 여환에서 효과적인 견치 및 전치부 견인을 통해 치료기간을 13개월로 단축할 수 있었다. 우려했던 치수의 실활 혹은 치주조직의 병소는 발견되지 않았으며 치료 후 10개월 유지 시에도 양호한 교합관계 및 치주조직의 건강상태를 보였다. 본 증례에서 소개된 방법을 통하여 급속 견인을 필요로 하는 경우에 보다 예측 가능한 방법으로 효율적인 치료를 할 수 있을 것으로 사료된다.

원통형 도파관 캐비티 필터의 마이크로파 방전과 고전력 취급 능력 (Microwave Breakdown and High-Power Handling Capability of Circular Waveguide Cavity Filter)

  • 이선익;김중표;임원규;김상구;장진백
    • 한국위성정보통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.80-85
    • /
    • 2017
  • 본 논문에서는 지상에서 시험 중에 발생한 X-대역 원통형 도파관 캐비티 필터의 방전을 소개하고, 원인 분석을 위하여 수행한 전자장 시뮬레이션 결과와 실제 운용궤도에서의 발생 가능성에 대하여 분석한 내용을 기술하였다. 전자장 시뮬레이션을 위하여 상용 툴(FEST3D)을 이용하여 필터를 모델링하고 대역폭 안팎의 주파수 신호(1 W Continuous Wave)를 입력하면서 필터 내부의 전계를 살펴보았다. 이 결과, 대역폭 중심보다는 가장자리(band edge) 주파수 신호가 입력되었을 때 필터 내부의 튜닝 스크류에서 더 강한 전계가 형성되는 것으로 나타났다. 그리고 방전 임계 전력을 산출하여 필터에 실제 입력된 전력과 비교해 본 바, 방전 임계값을 초과하는 전력이 필터에 입력되었고 이에 따라 강한 전계가 발생하고 온도가 급격히 상승하여 전기적인 단락으로 이어진 것으로 파악되었다. 추가적인 분석 결과 이 방전은 실제 운용궤도에서는 발생할 가능성이 낮고, band edge 주파수가 필터에 입력되더라도 멀티팩터(multipactor) 현상은 일어나지 않을 것으로 예측되었다. 지상에서 일어날 수 있는 마이크로파 방전에 대한 대책으로서 band edge 신호 입력을 피하거나 전력 레벨을 낮게 입력하는 방법을 제안하였다.

교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가 (Influence of immediate loading on the removal torque value of mini-screws)

  • 선승범;강윤구;김성훈;모성서;국윤아
    • 대한치과교정학회지
    • /
    • 제37권6호
    • /
    • pp.400-406
    • /
    • 2007
  • 교정치료에서 고정원의 조절은 교정 장치의 선택과 적용에서 가장 중요한 요소 중 하나이다. 이 연구의 목적은 교정용 미니스크류의 식립 즉시 교정력을 적용한 군과 교정력을 적용하지 않은 군의 제거회전력 측정과 조직학적 분석을 통해 즉시 교정력을 가한 미니스크류의 고정원으로서의 안정성을 확인하여 식립 후 교정력을 적용 수 있는 시기의 선택에 도움을 주고자 하는 것이다. 외경 1.6 mm. 길이 8 mm인 총 40개의 타이타늄 미니스크류를 10마리 가토의 경골에 식립하였다. 20개의 미니스크류 실험군은 식립 직후부터 6주 동안 지속적인 200g의 교정력을 적용하였고 나머지 20개의 미니스크류 대조군은 교정력을 적용하지 않았다. 제거 회전력은 디지털 토크 게이지를 이용하여 측정하였으며 t-test를 이용하여 통계처리 하였고, 조직표본은 미니스크류를 제거한 후 H-E 염색하여 조직 소견을 관찰하였다. 제거회전력은 실험군과 대조군에서 통계학적으로 유의성 있는 차이를 보이지 않았으며, 조직학적으로 두 군간의 차이는 없었다. 본 연구의 결과는 교정용 미니스크류에 즉시 교정력을 가하더라도 안정적인 고정원으로 활용 할 수 있다는 점을 제시한다.

양측 하악지 시상골 절단술 후 발생한 안면 신경 마비의 증례 (Facial Nerve Palsy after Bilateral Sagittal Split Ramus Osteotomy: Case Report)

  • 진수영;김수관;김학균;문성용;오지수;정경인;전우진;윤대웅;양석진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제33권3호
    • /
    • pp.276-280
    • /
    • 2011
  • BSSRO (bilateral sagittal split ramus osteotomy) is an effective surgical method for maxillofacial deformities. Rigid fixation using a plate and screws can stabilize bony segments and induce early mouth opening. Though this procedure has a low complication rate, normal function and esthetic recovery is achieved through proper and early management of the complications. Complications consisting of temporomandibular disorders, sensory disturbances due to inferior alveolar nerve damage, open bite, malunion or nonunion, and facial nerve palsy occur, but these rarely develop. Facial nerve palsy causes the muscles involved in facial expression to depress, which results in ocular dryness or retinal damage. When facial nerve palsy develops, early management involving steroid medication and physical therapy is effective. In the case of severe damage, surgical intervention should be considered. A 20-year-male patient came to the oral and maxillofacial surgery department for orthognathic surgery. The mandible was set back by BSSRO under general anesthesia. Facial nerve palsy was observed on the left side of the face: steroid and vitamins were administered early and physical therapy was performed daily. These forms of management can aid in function and allow for gradual esthetic recovery. Presumed causes were excessive soft tissue retraction or soft tissue injury by the osteotome at the horizontal osteotomy of the ramus. Careful dissection, retraction and a precise osteotomy are needed for protection of the facial nerve. If nerve damage is observed, early management can help in the recovery of facial nerve function and esthetics.

거골하 유합술 시 전방 및 후방 관절면 고정술식과 후방 관절면 단독 고정술식의 비교 (Comparison of Posterior Fixation Technique and Anterior-Posterior Fixation Technique in Subtalar Arthrodesis)

  • 정홍근;조형원;박현우;박종태
    • 대한족부족관절학회지
    • /
    • 제16권2호
    • /
    • pp.116-122
    • /
    • 2012
  • Purpose: Subtalar arthrodesis has been the gold standard for the painful subtalar joint disorders. Successful subtalar arthrodesis requires fusion of the 3 facet joints. The purpose of the study is to compare the clinical outcome of the posterior fixation (P2) and anterior-posterior (A1P1) fixation technique for subtalar arthrodesis which enhance anterior and middle facet fixation. Materials and Methods: The study is based on the 20 feet (19 patients) of the subtalar arthrodesis utilizing cannulated screws from September 2006 to September 2009 with at least 1-year follow-up. Two fixation techniques were utilized for the subtalar arthrodesis: 1) posterior fixation only (P2, 7 feet, 35%) and 2) anterior-posterior (A1P1) fixation method (13 feet, 65%). Visual Analog Scale Pain (VAS) score, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score (maximum: 94 points), the time for returning to daily living and the patient satisfaction were also evaluated. Results: Average follow-up period were 13.2 months (12-3 mo). The AOFAS score improved from preoperative average 45 (0-68) to 81.6 (62-94), while VAS score was decreased from average 8.0 (3-10) to 1.8 (0-5) at final follow-up. Ninety-five percent of the patients were satisfied with surgery. All the patients returned to daily living at average 7.2 months (2-15 mo) post-surgery. Radiographically, 2 techniques both showed 100% fusion of the posterior compartment of the subtalar joint. Postoperative complications were 1 case of low grade infection and 1 case of sural nerve neuralgia. Conclusion: The subtalar arthrodesis using A1P1 fixation technique showed better fusion rate of the anterior compartment of the subtalar joint compared to P2 fixation technique although the 2 techniques both showed similar favorable clinical outcome. Therefore the A1P1 fixation technique is found to be a viable option to address chronic painful subtalar joint disorders to enhance the anterior compartment fixation.

수종 임플랜트 시스템에서의 회전력에 관한 연구 (A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM)

  • 문익훈;정재헌
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력 (Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading)

  • 이주희
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.151-155
    • /
    • 2017
  • 목적: 이 연구의 목적은 새로운 타이타늄 구성요소를 가진 지르코니아 지대주의 나사 제거력의 변화에 대해 알아보는 것이다. 내부연결 임플란트를 위한 새로운 지르코니아 지대주의 동적하중 후 지대주 나사의 제거력을 기존의 타이타늄 지대주와 비교하여 분석하였다. 재료 및 방법: 내측연결 임플란트와 타이타늄 지대주, 타이타늄 구성요소를 가진 지르코니아 지대주를 준비하였다. 12개의 내부연결형 임플란트에 6개의 타이타늄 지대주를 연결하고(대조군), 6개의 타이타늄 구성요소를 가진 지르코니아 지대주(실험군)를 30 Ncm의 토크로 연결한 후 동적하중 전후의 나사 제거력을 측정하였다. 동적 만능재료시험기를 사용하여 연결체의 장축과 30도 각도를 이루도록 하고 300 N 하중크기로 100만번의 하중이 가해졌다. 동적하중 전후의 지대주 나사 제거력을 t검정을 통해 신뢰구간 95%로 통계적 유의성을 검증하였다. 결과: 두 그룹 모두에서 동적하중 후 나사 풀림을 보이지 않았다. 동적 하중 전후의 나사 제거력은 두 그룹 모두에서 통계적으로 유의한 차이가 있게 나타났다(P < .05). 동적 하중 전후의 나사 제거력 차이는 대조군에서 $-7.25{\pm}1.50Ncm$, 실험군에서 $-7.33{\pm}0.93Ncm$ 로 나타났다. 통계분석 결과 두 군간에 나사 제거력 차이에서는 유의한 차이를 보이지 않았다(P > .05). 결론: 이 실험의 결과에 한하여 타이타늄 구성요소를 사용한 지르코니아 지대주의 동적하중 후 지대주 나사 제거력의 변화는 타이타늄 지대주와 통계학적으로 유의한 차이를 보이지 않았다.

내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구 (The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study)

  • 경규영;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.114-118
    • /
    • 2017
  • 목적: 이 연구의 목적은 타이타늄 구성요소를 가진 지르코니아 지대주가 내부연결 임플란트에 사용되었을 때 나사 풀림에 대해 알아보는 것이다. 열순환 후 타이타늄 소켓을 가진 지르코니아 지대주와 타이타늄 지대주의 나사 풀림과 제거력을 비교 분석하였다. 연구 재료 및 방법: 내측연결 임플란트와 내측연결 타이타늄 지대주, 타이타늄 소켓을 가진 외측연결 지르코니아 지대주를 준비하였다. 내부연결형 임플란트에 5개의 타이타늄 지대주를(대조군), 타이타늄 소켓을 가진 5개의 지르코니아 지대주(실험군)를 각각 연결하고 30 Ncm의 토크로 조인 후 열순환 처리 전후의 지대주 나사 제거력을 측정하였다. 각 시편들은 열순환 장치의 수조에서 $5^{\circ}C$$55^{\circ}C$의 물에 60초씩 교대로 2,000회의 열순환을 시행하였다. 각 시편의 나사 풀림을 조사하고 열순환 전후에 나사 제거력을 통계학적으로 분석하였다. 결과: 두 그룹 모두에서 열순환 후 지대주 나사 풀림을 보이지 않았다. 열순환 전후의 나사 제거력 차이는 대조군에서 $-1.34{\pm}2.53Ncm$, 실험군에서 $-1.26{\pm}2.06Ncm$ 로 나타났다. 독립표본 T 통계분석 결과 두 군간에 유의한 차이를 보이지 않았다(P > 0.05). 결론: 이 실험의 결과 내에서 내부연결 임플란트를 위한 지르코니아 지대주 내 타이타늄 소켓이 열순환 후 지대주 나사풀림에 타이타늄 지대주와 비교하여 유의한 영향을 나타내지 않았다.

Subbrow Approach as a Minimally Invasive Reduction Technique in the Management of Frontal Sinus Fractures

  • Lee, Yewon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.679-685
    • /
    • 2014
  • Background Frontal sinus fractures, particularly anterior sinus fractures, are relatively common facial fractures. Many agree on the general principles of frontal fracture management; however, the optimal methods of reduction are still controversial. In this article, we suggest a simple reduction method using a subbrow incision as a treatment for isolated anterior sinus fractures. Methods Between March 2011 and March 2014, 13 patients with isolated frontal sinus fractures were treated by open reduction and internal fixation through a subbrow incision. The subbrow incision line was designed to be precisely at the lower margin of the brow in order to obtain an inconspicuous scar. A periosteal incision was made at 3 mm above the superior orbital rim. The fracture site of the frontal bone was reduced, and bone fixation was performed using an absorbable plate and screws. Results Contour deformities were completely restored in all patients, and all patients were satisfied with the results. Scars were barely visible in the long-term follow-up. No complications related to the procedure, such as infection, uncontrolled sinus bleeding, hematoma, paresthesia, mucocele, or posterior wall and brain injury were observed. Conclusions The subbrow approach allowed for an accurate reduction and internal fixation of the fractures in the anterior table of the frontal sinus by providing a direct visualization of the fracture. Considering the surgical success of the reduction and the rigid fixation, patient satisfaction, and aesthetic problems, this transcutaneous approach through a subbrow incision is concluded to be superior to the other reduction techniques used in the case of an anterior table frontal sinus fracture.