• 제목/요약/키워드: Screws

Search Result 651, Processing Time 0.026 seconds

Holding Strength of Screws in Domestic Particleboard and Medium Density Fiberboard (I) - Optimum Pilot Hole Diameter - (국산 파티클보오드와 중밀도 섬유판의 나사못 유지력(I) - 최적 예비구멍 직경 -)

  • Lee, Phil-Woo;Park, Hee-Jun;Han, Yu-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 1991
  • Screw withdrawal test was carried out on the face and edge of domestic particleboard and medium density fiberboard in order to evaluate optimum pilot hole diameter. The obtained results were as follows: 1. Maximum withdrawal strengths on the face and edge of particleboard were obtained with pilot hole diameters at about 50% of root diameters of screw. 2. Maximum withdrawal strength on the face and edge of medium density fiberboard were obtained with pilot hole diameters that were about 60% and 50% of root diameters of screw, respectively. 3. Withdrawal strength showed about 91% of maximum withdrawal strength when pilot holes were not pre bored at particleboard. but when pilot holes at 90% of root diameter of screw withdrawal strength showed about as 51.3% of maximum withdrawal strength. 4. Withdrawal strength showed about 88% of maximum strength when pilot holes were not used, but withdrawal strength indicated 55.4% of maximum strength in case of 90% of root diameters of screw. 5. Maximum withdrawal strength on the face of particleboard was about 70.5% higher than that of the edge, and however medium density fiberboard was about 19.6% higher than that of the edge.

  • PDF

CT-Guided Percutanous Nidus Excision of Osteoid Osteoma - Burr Down Technique - (유골 골종에서 전산화 단층 촬영 유도하 경피적 핵 절제술 - 천공기 이용법 -)

  • Kim, Byoung-Suck;Cho, Jae-Hyun;Lee, Kyi-Beom;Yu, Chung-Su;Ahn, Jae-In
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.1
    • /
    • pp.51-55
    • /
    • 1999
  • Aspirin has usually been taken for pain relief originating in the nidus of osteoid osteoma, however it takes too long to become effective. Because of the protracted painful course and the unpredictability of regression, osteoid osteoma is usually removed. And then, the defective host bone is internally fixed by plate and screws and augumented by autogenous bone graft. However, the common intracortical location and exuberant periosteal reaction hinders the exact intraoperative localization of the nidus. The authors managed 6 patients by computerized tomography-guided percutaneous nidus excision with a relatively small skin incision, small cortical window, short operation time and no bone graft. It may be one of the best options for removal of the nidus of osteoid osteoma with certainty.

  • PDF

Transmasseteric Approach for Open Reduction and Internal Fixation of Mandible Subcondylar Fracture (깨물근을 통한 하악골 관절돌기하부골절의 관혈적 정복 및 내고정술)

  • Kim, Hak-Soo;Kim, Seong-Eun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.161-168
    • /
    • 2010
  • Purpose: Surgical approaches to the condylar neck and subcondyle area can cause some morbidity such as, facial nerve injury, time-consuming nature and external scar etc. So many surgeons hesitate using open reduction and internal fixation for the treatment of subcondylar fractures. We report open reduction and internal fixation of subcondylar fractures in 13 adult patients via transmasseteric approach. Methods: From 2007 to 2009, 13 adults with subcondylar fracture of mandible were treated with open reduction and internal fixation via transmasseteric approach. A preauricular incision was extended downwards in a curvilinear fashion in the cervicomastoid skin crease. Skin flap was elevated above the SMAS layer. Masseter muscle was splitted at the anteroinferior edge of the parotid gland. After the fracture was reduced, fixed with appropriate plates and screws. All operation were performed under general anesthesia. Results: Mean follow-up period was 13.3 months. There were no signs and symptoms of facial nerve injury, difficulty in mouth opening, or malocclusion. Dissection time was roughly within 30 minutes. Conclusion: Transmasseteric open reduction and internal fixation of mandible subcondylar fracture can be performed with excellent visualization, and inconspicuous scar. It also offers swift access to the subcondylar area while substatially reducing the risk to the facial nerve and eliminating the complications associated with transparotid approaches.

The Development of the Shunt Guiding Kit for the Proper Positioning of the Proximal Shunt Catheter to the Lateral Ventricle in the Ventriculo-Peritoneal Shunt Operation (뇌실-복강간 단락술에서 Proximal Catheter의 정확한 측뇌실내로의 위치를 위한 Shunt Guiding Kit의 개발)

  • Shin, Yong Sam;kim, Se-Hyuk;Zhang, Ho Yeol;Bae, Ju Yong
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.8
    • /
    • pp.981-984
    • /
    • 2001
  • Object : To treat hydrocephalus by ventriculo-peritoneal shunt operation, the correct positioning of the proximal catheter in the ventricle is very important. The purpose of this study was to develop the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle in the ventriculo-peritoneal shunt operation. Materials and Methods: The "shunt guiding kit" is made of tungsten alloy and it consists of one frame, two screws and one guider. Through the guider, the proximal shunt catheter operates by mechanically coupling the posterior burr hole to the anterior target point. Results: We have treated three hydrocephalus patients with use of the "shunt guiding kit", and achieved good location of proximal shunt catheters. Conclusion: We developed the "shunt guiding kit" for the proper positioning of the proximal shunt catheter to the ventricle, and this would be very useful for preventing ventriculo-peritoneal shunt malfunction and preventing possible brain injury during the procedures.

  • PDF

Intraoperative Vertebral Artery Angiography to Guide C1-2 Transarticular Screw Fixation in a Patient with Athetoid Cerebral Palsy

  • Chung, Jong-Chul;Jung, Sung-Sam;Park, Ki-Seok;Ha, Ho-Gyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.3
    • /
    • pp.177-181
    • /
    • 2012
  • We present a case of an athetoid cerebral palsy with quadriparesis caused by kyphotic deformity of the cervical spine, severe spinal stenosis at the cervicomedullary junction, and atlantoaxial instability. The patient improved after the first surgery, which included a C1 total laminectomy and C-arm guided righ side unilateral C1-2 transarticular screw fixation. C1-2 fixation was not performed on the other side because of an aberrant and dominant vertebral artery (VA). Eight months after the first operation, the patient required revision surgery for persistent neck pain and screw malposition. We used intraoperative VA angiography with simultaneous fluoroscopy for precise image guidance during bilateral C1-2 transarticular screw fixation. Intraoperative VA angiography allowed the accurate insertion of screws, and can therefore be used to avoid VA injury during C1-2 transarticular screw fixation in comorbid patients with atlantoaxial deformities.

Vertical Reduction Using Atlantoaxial Facet Spacer in Basilar Invagination with Atlantoaxial Instability

  • Kim, Il-Sup;Hong, Jae-Taek;Sung, Jae-Hoon;Byun, Jae-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.6
    • /
    • pp.528-531
    • /
    • 2011
  • Although posterior segmental fixation technique is becoming increasingly popular, surgical treatment of craniovertebral junctional disorders is still challenging because of its complex anatomy and surrounding critical neurovascular structures. Basilar invagination is major pathology of craniovertebral junction that has been a subject of clinical interest because of its various clinical presentations and difficulty of treatment. Most authors recommend a posterior occipitocervical fixation following transoral decompression or posterior decompression and occipitocervical fixation. However, both surgical modalities inadvertently sacrifice C0-1 and C1-2 joint motion. We report two cases of basilar invagination reduced by the vertical distraction between C1-2 facet joint. We reduced the C1-2 joint in an anatomical position and fused the joint with iliac bone graft and C1-2 segmental fixation using the polyaxial screws and rods C-1 lateral mass and the C-2 pedicle.

Triple-Mode Characteristics of Cylindrical Cavity Loading a Cylindrical Dielectric Resonator

  • Lee, Seung-Mo;Kim, Cha-Man;Park, Jong-Chul;Kim, In-Ryeol;Oh, Soon-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.630-636
    • /
    • 2016
  • In this paper, a novel triple-mode cavity structure, designed for compactness and operating at 850 MHz, is analyzed. A cylindrical dielectric resonator is loaded into a metallic cylindrical cavity. Previous study has been focused on the analysis of the cylindrical dielectric resonator, but in this paper, the effect of the cylindrical metallic cavity has been analyzed. Enclosing the dielectric resonator inside the metallic cavity increases the resonant frequency of the dielectric resonator; however, this increases the quality factor and introduces the possibility of installing coupling screws. The principle of generation of triple-mode was investigated by parametric analysis. The generated triple-mode is TE011 mode and two orthogonally generated HEM121 modes. By adjusting the radius of the dielectric resonator, the height of the dielectric resonator, or the radius of the cylindrical metallic cavity, three modes could be coincided. However, the height of the metallic cavity keeps three modes separated. The mode characteristics of the proposed cavity are analyzed using a full-wave electromagnetic (EM) simulation. The proposed triple-mode cavity could be developed to triple-mode filter using a coupling screw, and the commercial application for the miniaturized filter below 1 GHz could be expected.

Optimal Swimming Motion for Underwater Robot, Crabster (수중유영로봇 Crabster의 최적 유영 구현)

  • Kim, Daehyun;Lee, Jihong
    • The Journal of Korea Robotics Society
    • /
    • v.7 no.4
    • /
    • pp.284-291
    • /
    • 2012
  • Recently, development of underwater robot has actively been in progress in the world as ROV(Remotely Operator Vehicle) and AUV(Autonomous Unmmanded Vehicle) style. But KIOST(Korea Institute of Ocean Science and Technology), beginning in 2010, launched the R&D project to develop the robot, dubbed CRABSTER(Crab + (Lob)ster) in a bid to enhance the safety and efficiency of resource exploration. CRABSTER has been designed to be able to walk and swim with its own legs without screws. Among many research subjects regarding CRABSTER, optimal swimming patterns are handled in this paper. In previous studies, drag forces during one period with different values for angle of each joint were derived. However kinematics of real-robot and fluid-dynamics are not considered. We conducted simulations with an optimization algorithm for swimming by considering simplified fluid dynamics in this paper. Drag-coefficients applied to the simulation were approximated values calculated by CFD(Computational Fluid Dynamics : Tecplot 360, ANSYS). In addition, optimized swimming patterns were applied to a real robot. The experiments with the real robot were conducted in circumstances in the water. As a result, when the experiments were carried out in the water, a regular pattern of drag force output came out depending on the movement of the robot. We confirmed the fact that the drag forces from the simulation and the experiment has a high similarity.

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF

Studies on the Shape Optimization of Connecting Element for Hydro-Embedding (하이드로 임베딩시 체결용 연결요소의 형상 최적화 연구)

  • Kim B. J.;Kim D. K.;Kim D. J.;Moon Y. H.
    • Transactions of Materials Processing
    • /
    • v.14 no.9 s.81
    • /
    • pp.756-763
    • /
    • 2005
  • The applicability and productivity of hydroforming process can be increased by combining pre- and post-forming processes such as the bending, piercing and embedding process. For the fabrication of automotive parts, the hollow bodies with connecting nuts are widely used to connect parts together. Hollow body with connecting nuts has been conventionally fabricated by welding nuts or screwing in autobody screws. It requires multiple steps and devices fur the welding and/or screwing Therefore in this study, hydro-embedding process that combines the hydraulic embedding of connecting element(nut) with hydroforming process is investigated. Studies on the hydro-embedding technology have been performed to optimize the shape of the connecting element by analyzing the deformed mode of the embedded tube The effects of the shape of the screw tip, screw thread and shape of thread on the connection force between the tube and the connecting element have been investigated to optimize the shape of connecting element. Finite element analysis has also been performed to provide deformation behaviors of the tube surrounding a hole produced by hydro-embedding.