• Title/Summary/Keyword: Screws

Search Result 651, Processing Time 0.027 seconds

Esophageal Injury Following Anterior Cervical Plate Fixation

  • Park, Jae-Sung;Kim, Young-Baeg;Hong, Hyun-Jong;Hwang, Sung-Nam
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.141-145
    • /
    • 2005
  • We report five patients of esophageal injuries confirmed by clinical signs and radiological evidences. They include a partial tear and a perforation which were not noticed during the operation, a perforation which was primarily repaired during the operation, and two perforations which occurred during the reoperations for the removal of mal-positioned screws or plate. The partial tear was not repaired. The perforation which occurred during the operation was primarily sutured and didn't receive further treatment. Two perforations which occurred during the reoperations were treated by irrigation, debridement with surgical drainage, and systemic antiobiotics. One who was diagnosed later after the operation showed the poorest outcome and required longest hospital days among our series. Early detection and appropriate treatment of esophageal injury following anterior spinal surgery can only improve the prognosis by preventing secondary complications.

Development and Performance Evaluation of Single screw Polymer Extruder System (단축스크류 고분자압출기 시스템의 개발 및 성능평가)

  • Kim, Jae-Yeol;Jung, Hyo-Hee;Choi, Jin-Ho
    • Tribology and Lubricants
    • /
    • v.25 no.3
    • /
    • pp.182-186
    • /
    • 2009
  • Extruders can be basically divided into bisk and screw type of extruders. Though plastic extruders are often used for its simplicity for water and oil transportation pumps, these days screw extruders are mostly used. Screws are used in many extrusion processes to manufacture complex and complicated shaped parts made of plastics, medicine materials, food, polymer composites, iron and ceramic powders, etc. Also, material correction of deformities is caused by flow and physicochemical reaction phenomenonand material extrusion is processed according to heat transfer. various material comes to hopper because extruder has function by blender and mixing of materials can go well before come out through dice. These change process is so complicated that process condition is decided by trial and error that process condition is underground mainly at extrusion molding process.

Acceleration analysis by using line geometry and its application to dynamics (선 기하를 이용한 가속도 해석과 동역학에의 적용)

  • 홍만복;최용제
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.912-915
    • /
    • 2002
  • It has been known that general velocity and force of a rigid body in space can be described in forms of a twist and a wrench by use of screws. However, the geometrical meaning of acceleration has not been clearly disclosed. It has been a normal practice to analyze or synthesize the acceleration effect of manipulator using some complex mathematical equations, which do not represent any geometrical meanings. In other words, such a technique doesn't clearly provide information about the overall acceleration state of manipulator at that instant. In this study, the geometrical meaning of acceleration of a rigid body has been investigated and thereby a geometrical procedure which can be applied to inverse acceleration analysis of a general non-redundant manipulator is presented as an application.

  • PDF

Arthroscopy Assisted 2 Cannulated Screw Fixation for Transverse Glenoid Fracture: A Case Report

  • Park, Sam-Guk
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.105-109
    • /
    • 2016
  • Arthroscopy is recognized as an important adjunct in treatment of intra-articular fractures. The author reports on successful treatment of a displaced transverse glenoid cavity fracture, reduced and fixed with arthroscopic assist, using two cannulated screws perpendicular to the fracture surface, in a patient with frail chest. One screw passed through the Neviaser portal, and the other screw passed through the base of the coracoid process. Arthroscopy assisted reduction and 2 cannulated screw fixation through the Neviaser portal and coracoid base appears to be a good method for treatment of transverse glenoid fractures.

문형식 표지판 지지대의 모멘트 분포와 변형에 대한 해석 및 안정성 분석

  • Im, Hyeong-Tae;Kim, So-Hyeong;Park, Seong-Hyeon
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.251-256
    • /
    • 2015
  • In this paper, an systematic approach is presented, in which the bridge-type traffic sign structure is body out by CSDDA PrePost Processor. There is dead load and wind load that is working on the structure which will make force and moment. Analyzied the stress distribution of the standard form and by changing the shape, compared the safety in terms of deflection and stress (with the standard form) to know the effect of each component in the bridge-type traffic sign structure. The safety of deflection and stress is evaluated by maximum distance/100) and ASIC code respectively. The standard form of bridge-type traffic sign structure is established by two pairs of pillar and two pairs of floor beam. Replaced the links which is consist of flange and screws as the torsion spring and nm our analysis program. By adjusting variable of rigidity modulus of torsion spring, moment between column and beam is controled depending on value of rigidity modulus.

  • PDF

APPLICATION OF RECONSTRUCTION PLATE USING SIMPLE CONDYLAR REPOSITIONING MINIPLATE AFTER SEGMENTAL RESECTION OF MANDIBLE (하악골 절제술후 간단한 과두재위치 소형금속판을 이용한 재건 금속판의 적용: 증례보고)

  • Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.3
    • /
    • pp.231-233
    • /
    • 2002
  • Temporary reconstruction of the mandibular continuity defect resulting from the ablative tumor surgery with a reconstruction plate can be used for the preservation of normal facial contour and oral function and for periodic follow up of recurrence. Reconstruction plates are adapted to the bone before the resection and provisionally fixated with some screws. Accurate contouring and adaptation are very important for the prevention of displacement of bony stumps and decubituous skin ulcer. However, if there is large expanding buccal tumor mass in mandible, it is very difficult or even impossible to contour the plate before resection. I, therefore, introduce the reconstruction plate application technique using a simple condylar repositioning miniplate after segmental mandibular resection.

A STUDY ON FITNESS OF SEVERAL DOMESTIC IMPLANT FIXTURE AND ABUTMENT SCREWS (국내제작 임프란트 고정체와 지대주 유지나사의 적합도에 대한 주사전자현미경적 비교연구)

  • Park Young-Sun;Vang Mong-Sook;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.94-109
    • /
    • 2004
  • Statement of problem : Several domestic dental implants have been developed since dental treatment being implants are increasing and popularized. However, they have not been used in domestic market like imported goods. Material and methods : This study was carried out to compare domestic and imported implants in aspect of fitness, dental implant fixture and abutment screw using scanning electron microscope. All experiments were performed under dry condition. Results : 1. Only in aspect of relation of dental implant fkxture and abutment screw, except only one group with point contact, good fitness was existed. 2. Home products must presevere in their efforts, so as excellent to fit.

An Analysis of a Thermo-plastic Melt Flow in the Metering Zone of a Polymer Extruder (고분자 압출기에 있어서 계량부 용융수지의 유동해석)

  • Choi, Man Sung;Kim, Kwang Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.7-12
    • /
    • 2012
  • Extrusion is one of the most important operations in the polymer-processing industry. Development of models for extrusion and computer tools offer a route to developing reliable and optimized process designs. The models are based on the analysis of physical phenomena encountered during the process. Balance equations for mass, momentum and energy are fundamental to the problem. A predictive computer model has been developed for the single screw extruders with conventional screws of different geometry. The model takes into account melting zones of the extruder and describes an operation of the extruder system, making it possible to predict mass flow rate of the polymer, pressure and velocity profiles along the extruder screw channel. The simulation parameters are the material and rheological properties of the polymer; the screw pitch, and screw speed.

An Analysis of Vibration Attenuation Effect of the different type of Gloves and Drilling Mode (진동모드에 따른 각종 장갑의 방진효과 분석)

  • 황성환;이형일;이동충
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.69
    • /
    • pp.65-73
    • /
    • 2001
  • The objective of this study is to evaluate the vibration attenuation effects of the different type of gloves and drilling mode while operating a light-weighted powered hand drill. For the experimental design, five different kinds of glove(barehanded cotton partly coated anti-vibration, and open-finger vibration glove) two types of push force level(100N and 200N) and two types of drilling mode(impact and non-impulsive) were considered. Six healthy male subjects were employed to drive screws into a vertically mounted marble plate with a powered hand drill in a randomly ordered experimental conditions. The findings of this study are summarized as follows; (1) It was found that the best combination of overall BMS transmissibility was using impact drilling mode with anti-vibration glove among evaluated experimental conditions (2) The wearing open finger vibration glove in mid-frequency level and anti-vibration glove with impact drill in high-frequency were the best in the result from mean corrected transmissibility equation of ISO 10819.

  • PDF

RETROSPECTIVE MULTICENTER STUDY OF CSM ENDOSSEOUS DENTAL IMPLANT

  • Park, Eun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.321-328
    • /
    • 2007
  • Statement of problem. To work the economic limitation of dental implant usage, some types of domestic implant have been developing. But, there have been seldom reported about the clinical success rate of them as yet. Purpose. The aim of this retrospective multicenter study was to evaluate the performance of CSM implants(CSM company, Daegu, Korea). Material and methods. Thirty-five patients were rehabilitated with 150 CSM implants in this multicenter study. Results. The success rate was 96.2%. CSM Titanium fixtures can obtain slightly higher success rate when a cover screw was not used for implant installation than when used. However it doesn't show significant difference(p=.7615, Fisher's Exact test). Conclusion. This multicenter retrospective study demonstrated the efficacy of the CSM implant in the treatment of variety of clinical manifestation of tooth loss. And it can be assumed that whether a cover screw is used or not should no influence on the osseointegration.