• Title/Summary/Keyword: Screw stability

Search Result 239, Processing Time 0.022 seconds

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.

A Study on the Analysis and Design for a Ball Screw Whirling Machine (볼스크류 선회형 가공장비의 설계 및 해석에 관한 연구)

  • Lee, Choon-Man;Moon, Sung-Ho;Kim, Eun-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.3
    • /
    • pp.173-178
    • /
    • 2017
  • Recently, a high-precision ball screw is an essential part of high-speed machines. However, producing high-precision ball screws has been costly and time-consuming. Nowadays, a whirling machine is used to produce high-precision ball screws efficiently. Rotating multi-tips are used to turn the ball screw in the whirling machine. In this study, a structural analysis was performed by a finite-element method to develop a whirling machine. An improved model of the whirling machine was proposed by the analysis. In addition, a thermal analysis was performed to confirm the thermal stability. The results of the analysis can be applied in order to further develop the whirling machine.

The Vibration Analysis of Cylinder and Screw for Industrial Centrifuge (산업용 원심분리기의 실린더와 스크류 진동해석)

  • 권용수;홍도관;김동영;안찬우;한근조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.803-806
    • /
    • 2002
  • This paper estimated the stability of centrifuge as its rotating speed compared with the natural frequency of cylinder and screw by finite element analysis. It shows that the one of exciting causes is the tooth passing frequency of input and output parts by the periodic characteristics of transmission error due to an planetary gear having three stages. Also, it proposed the critical speed of cylinder and screw by the Campbell diagram.

  • PDF

Analysis of the Bone-remodeling Process Considering Stimuli Delivery Cell Model (자극전달세포 모델을 고려한 골 재형성 해석)

  • Moon Hee-Wook;Kim Young-Eun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.6 s.183
    • /
    • pp.180-186
    • /
    • 2006
  • To investigate the bone remodeling phenomenon around implant device, 3-D mathematical simulation model was developed. Strain energy density from the finite element method was chosen for the indicator for remodeling process. Recursive calculations continued until converged results between FEM and mathematical model. For a osteo-integration example, bone-remodeling process in a implanted tibia of beagle was adapted. Calculated results indicated that the bone densities around screw pitch were increased which indicates firm fixations between the bone and implant. Screw design parameters have an influence on initial stability of the implant rather than remodeling process.

Treatment of Secondary Soft Tissue Compromised Calcaneus Fractures Using a Cannulated Screw and Simple Cerclage Wiring: A Report of Two Cases (이차적인 연부조직 손상을 동반한 종골 골절에 대한 유관 나사 및 단순 환상 강선 고정술을 이용한 치료: 2예 보고)

  • Kim, Junkyom;Suh, Jae Wan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.165-169
    • /
    • 2017
  • Secondary soft tissue injuries can occur from the pressure of the displaced fragment of posterior calcaneal tuberosity in calcaneal tongue-type fractures and calcaneal tuberosity avulsion fractures. The soft tissue injury can be prevented by immediate reduction of the displaced fragments. Various techniques can be used to fix the fracture fragments, but the stability of fixation and minimal invasiveness to soft tissue should be considered. This paper reports the successful outcomes of patients with soft tissue compromises in calcaneal tongue-type fractures and calcaneal tuberosity avulsion fractures. The fixation technique of a large cannulated screw and simple cerclage wiring is believed to be a useful surgical option for the treatment of secondary soft tissue compromised calcaneal fractures.

The Characteristics of High Speed Feed Drive System using High Lean Screw (High Lead Ball Screw를 사용한 고속이송계의 특성)

  • 고해주;박성호;정윤교
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.4
    • /
    • pp.97-103
    • /
    • 2001
  • The study on the high-speed machine tool is very important for the improvement of productivity since it can shortens cutting and non-cutting time. Especially, high speed of feed drive system is the major research field. In the industries of the advanced countries, the feed drive systems at the speed of 60 m/min have been already developed based on the high lead ball screws. In this study, a high speed feed drive system at the speed of 60 m/ min has been developed, and its movements characteris-tics are investigated. As the movement characteristics, positioning accuracy, angular accuracy, straightness and micro step-response are measured. Thermal characteristics of the system is also discussed. For measuring the movement characteris-tics, a laser interferometer, a memory-based Hi-coder and a cooling device are used. The experimental results confirm that the movement characteristics and the thermal behavior of the system are satisfactory in the aspect of accuracy and stability.

  • PDF

The Result of Mandible Fracture Fixations with Biodegradable Materials (생체흡수성 재료를 이용한 하악골절 치료의 결과)

  • Wang, Jae Kwon;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Craniofacial Surgery
    • /
    • v.9 no.2
    • /
    • pp.45-50
    • /
    • 2008
  • Purpose: Traditionally, titanium miniplate has been used for rigid fixation of mandible fractures. However, the limitations of metal plate have been reported such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy, and so forth. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite of its lower strength. This study evaluated the usefulness and stability of biodegradable plate and screw for treatment of mandible fractures. Methods: In this study, 61 patients(92 areas) diagnosed as mandible fracture in the last 2 years have been reviewed. We used titanium plate and screw in 32 patients, and biodegradable plate and screw($INION^{(R)}$) in 29 patients. Stability of plates and screws, bony healing process and its side effects were observed by clinical and radiographic assessment. Results: In the titanium material group, one of malocclusion, two of mouth opening limitation, three of pain, three of palpation were shown. The plate of six patients involved in these complications were removed. In the biodegradable group, two of mouth opening limitation, two of pain, one of localized wound infection were shown and one plate was removed secondarily. Conclusion: There was no statistical difference between two groups in bony healing and complication rates. Biodegradable implants show efficient stability during initial bone healing and low side effects in long-term follow up periods.

Influence of Tightening Torque on Implant-Abutment Screw Joint Stability (조임회전력이 임플랜트-지대주 나사 연결부의 안정성에 미치는 영향)

  • Shin, Hyon-Mo;Jeong, Chang-Mo;Jeon, Yonung-Chan;Yun, Mi-Jeong;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.396-408
    • /
    • 2008
  • Statement of problem: Within the elastic limit of the screw, the greater the preload, the tighter and more secure the screw joint. However, additional tensile forces can incur plastic deformation of the abutment screw when functional loads are superimposed on preload stresses, and they can elicit the loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum preload that will maximize fatigue life and simultaneously offer a reasonable degree of protection against loosening. Another critical factor in addition to the applied torque which can affect the amount of preload is the joint connection type between implant and abutment. Purpose: The purpose of this study was to evaluate the influence of tightening torque on the implant-abutment screw joint stability. Material and methods: Respectively, three different amount of tightening torque (20, 30, and 40 Ncm) were applied to implant systems with three different joint connections, one external butt joint and two internal cones. The initial removal torque value and the postload (cyclic loading up to 100,000 cycles) removal torque value of the abutment screw were measured with digital torque gauge. Then rate of the initial and the postload removal torque loss were calculated for the comparison of the effect of tightening torques and joint connection types between implant and abutment on the joint stability. Results and conclusion: 1. Increase in tightening torque value resulted in significant increase in initial and postload removal torque value in all implant systems (P < .05). 2. Initial removal torque loss rates in SS II system were not significantly different when three different tightening torque values were applied (P > .05), however GS II and US II systems exhibited significantly lower loss rates with 40 Ncm torque value than with 20 Ncm (P < .05). 3. In all implant systems, postload removal torque loss rates were lowest when the torque value of 30 Ncm was applied (P < .05). 4. Postload removal torque loss rates tended to increase in order of SS II, GS II and US II system. 5. There was no correlation between initial removal torque value and postload removal torque loss rate (P > .05).

Comparative study of abutment screw loosening with or without adhesive material

  • Arshad, Mahnaz;Shirani, Gholamreza;Refoua, Sina;Yeganeh, Mohammadreza Rahimi
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.99-103
    • /
    • 2017
  • PURPOSE. The purpose of this study was to achieve more retention and stability and to delay or prevent screw loosening. MATERIALS AND METHODS. Twenty implants (Implantium 3.4 mm, Dentium, Seoul, Korea) were divided into 2 groups (n = 20). In the first group, an adhesive material was applied around the screw of the abutments (test group). In the second group, the screws are soaked in saliva (control group). All the screws were torqued under 30 N/cm, Then, the samples were gone through a cyclic fatigue loading process. After cyclic loading, we detorqued screws and calculated detorque value. RESULTS. In comparison with the control group, all the implant screws in the test group were smeared with the adhesive material, showing significant higher detorque value. CONCLUSION. There are significantly higher detorque values in the group with adhesive. It is recommended to make biocompatible adhesive to reduce screw loosening.

Development of polypropylene-clay nanocomposite with supercritical $CO_2$ assisted twin screw extrusion

  • Hwang, Tae-Yong;Lee, Sang-Myung;Ahn, Young-Joon;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2008
  • The aim of this study is to explore the possibility of incorporating supercritical carbon dioxide ($scCO_2$) into twin screw extrusion process for the production of polypropylene-clay nanocomposite (PPCN). The $CO_2$ is used as a reversible plasticizer which is expected to rapidly transport polymeric chains into the galleries of clay layers in its supercritical condition inside the extruder barrel and to expand the gallery spacings in its sub-critical state upon emerging from die. The structure and properties of the resulting PPCNs are characterized using wide-angle X-ray diffraction (WAXD), transmission electron microscopy (TEM), rheometry, thermogravimetry and mechanical testing. In the processing of the PPCNs with $scCO_2$, optimum $scCO_2$ concentration and screw speed which maximized the degree of intercalation of clay layers were observed. The WAXD result reveals that the PP/PP-g-MA/clay system treated with $scCO_2$ has more exfoliated structure than that without $scCO_2$ treatment, which is supported by TEM result. $scCO_2$ processing enhanced the thermal stability of PPCN hybrids. From the measurement of linear viscoelastic property, a solid-like behavior at low frequency was observed for the PPCNs with high concentration of PP-g-MA. The use of $scCO_2$ generally increased Young's modulus and tensile strength of PPCN hybrids.