• Title/Summary/Keyword: Screw stability

Search Result 240, Processing Time 0.027 seconds

Computer Simulation and Control performance evaluation for Feedback System of Ultra Precision Positioning by using Laser Interferometer (Laser Interferometer를 이용한 초정밀위치결정 피드백시스템의 컴퓨터 시뮬레이션 및 제어성능 평가)

  • Kim, Jae-Yeol;Kim, Young-Seok;Yoon, Sung-Un;Kwac, Lee-Ku;Han, Jae-Ho;You, Sin
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.68-74
    • /
    • 2001
  • This system is composed of fine and coarse apparatus, measurement system and control system. Piezoelectric actuator is designed for fine positioning. We make a study of precision apparatus that is used in the various industrial machine. The study was carried out to develope a precision positioning apparatus, consisting of servo motor and piezoelectric actuator. Coarse positioning using lead screw is drived by servo motor. Control system output a signal from laser interferometer to amplifier of servo motor and piezoelectric actuator after digital signal processing(DSP). Resolution of this apparatus measure with laser interferometer. In this study, design method and control system with ultra precision position apparatus are researched. As the first step, we have estimated for control performance and system stability before an actual apparatus is manufactured by MATLAB with SIMULINK including various functions those are composed of pre-design and system modeling.

  • PDF

Anterior and Posterior Stabilization by One Stage Posterolateral Approach in the Unstable Fracture of Thoracolumbar and Lumbar Spine

  • Lee, Young-Min;Cho, Yang-Woon;Kim, Joon-Soo;Kim, Kyu-Hong;Lee, In-Chang;Bae, Sang-Do
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.1
    • /
    • pp.22-27
    • /
    • 2006
  • Objective : The purpose of this study is to investigate the clinical results of anterior and posterior stabilization by one stage posterolateral approach for the unstable fracture of thoracolumbar and lumbar spine. Methods : By posterolateral approach with curved skin incision, unilateral facet and pedicle were removed. Through this route, corpectomy was performed, and then this space was replaced with mesh cage filled up with autologous bone graft. Both side pedicle screw fixation was followed to upper and lower levels. Results : Six of seven patients of this study showed neurological improvement. The other one patient showed no neurological change. One patient had postoperative infection, another patient had postoperative kyphosis. The other patient had epidural hematoma on operation site after surgery. And all patinets on this study made to have spinal stability except one patient happened postoperative kyphosis. Conclusion : In the unstable fracture of thoracolumbar and lumbar spine, one stage anterior and posterior stabilization and fusion by posterolateral approach seems to be an effective procedure, if we have more care and supplementation.

Microstructure, Thermal Properties and Rheological Behavior of PLA/PCL Blends for Melt-blown Nonwovens (멜트블론 부직포 제조를 위한 PLA/PCL 블렌드의 미세구조, 열적특성, 및 유변학적 성질)

  • Sun, Hui;Yu, Bin;Han, Jan;Kong, Jinjin;Meng, Lingrui;Zhu, Feichao
    • Polymer(Korea)
    • /
    • v.38 no.4
    • /
    • pp.477-483
    • /
    • 2014
  • Poly(lactic acid) (PLA) and poly(${\varepsilon}$-caprolactone) (PCL) blends with various components for melt-blown non-wovens were prepared by a twin-screw extruder. Tributyl citrate (TBC) was added in order to improve the miscibility between PLA and PCL. The results showed that small circular particles of PCL were dispersed in PLA matrix uniformly. The addition of PCL had the heterogeneous nucleation effect on the crystallization of PLA and decreased thermal stability of PLA. The flow of pure PLA and blends approached to Newtonian liquid at a low shear rate and expressed more obvious viscoelasticity at a high shear rate.

RESONANCE FREQUENCY ANALYSIS OF IMPLANTS WITH ANODIZED SURFACE OXIDES

  • Choi Jeong-Won;Heo Seong-Joo;Chang Ik-Tae;Koak Jai-Young;Han Jong-Hyun;Kim Yong-Sik;Lee Seok-Hyung;Yim Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.3
    • /
    • pp.294-300
    • /
    • 2004
  • The present experimental study was designed to address two issues. The first was to investigate whether oxidation voltage of titanium implants influenced bone tissue responses after an in vivo implantation. The second aim was to investigate secondary stability change after 1 to 3months period. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of $3-15{\mu}m$. The micro structure revealed pore sizes of $1-3{\mu}m$, the crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. Bone tissue responses were evaluated by resonance frequency measurements that were undertaken 1 to 3months after insertion in the rabbit tibia. It was concluded that no statistical difference of RFA values was found between the groups, RFA gains after Imonth and 3months were calculated.

Computer Simulation and Control Performance Evaluation for Feedback System of Ultra Positioning by using Laser Interferometer (Laser Interferometer를 이용한 초정밀위치결정 피드백시스템의 컴퓨터 시뮬레이션 및 제어성능 평가)

  • 김재열;이규태;곽이구;한재호;김창현
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.17-25
    • /
    • 2002
  • This system is composed of fine and coarse apparatus, measurement system and control system. Piezoelectric actuator is designed far fee positioning. We make a study of precision apparatus that is used in the various industrial machine. The study was carried out to develope a precision positioning apparatus, consisting of servo motor and piezoelectric actuator Coarse positioning using lead screw is thrived by servo motor. Control system output a signal from laser interferometer to amplifier of servo motor and piezoelectric actuator after digital signal processing (DSP). Resolution of this apparatus measure with laser interferometer. In this study, design method and control system with ultra precision position apparatus are researched. As the first step, we have estimated for control performance and system stability before an actual apparatus is manufactured by MATLAB with SIMUUNK including various frictions those are composed of pre-design and system modeling.

Initial Lengthening Behavior of Cadaveric Achilles Tendon Graft After Posterior Cruciate Ligament Reconstruction (후방십자인대 재건술 후 사체 아킬레스 이식건의 초기연신거동)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Lee, Ho-Sang;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1461-1466
    • /
    • 2008
  • In the case of Posterior Cruciate Ligament (PCL), the most frequent mechanism is the dashboard injury, which is directly pressurized to the anterior of the proximal tibia in the state of the knee hyperflexion. The PCL associated ligament damage happens when the posterior injury, the varus, the valgus, the hyperextension and the severe vagus torque are out of the critical value of PCL. After the successful operation cases of Anterior Cruciate Ligament (ACL) reconstruction using the allograft were informed from 1986, a number of results kept over the maximum 10 years were reported. Unfortunately, PCL reconstruction are crowded the surgery techniques such as the graft, the tibia fixing method, the fixation device, the location of the femoral tunnel, the number of the graft bundles and PCL reconstruction to access to the stability of the normal joint is being developed. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The initial extension of the Achilles tendon by the fixing device and its location under the cyclic loading, were observed.

  • PDF

Comparative Study of Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Versus Four-Stranded Semitendinosus-Gracilis Tendon (관절경적 전방십자인대 재건술시에 골-슬개건-골과 네가닥 반건양건-박건을 이용한 방법의 비교연구)

  • Kim, Jin Goo;Lim, Young;Kim, Byung Jik;Ko, Han Suk;Moon, Hyung Tae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 1998
  • This study is retrospective analysis of 31 patients treated by arthroscopically assisted ACL reconstruction, from September 1995 to September 1996. ACL reconstructions using autogenous bone patellar tendon bone (B-PT-B) were done in 18 patients, and using hamstring tendon were done in 13 patients. We used four-stranded hamstring tendon grafts and fixed the grafts using Endobutton and screw. The mean postoperative Lysholm knee score was 87.2 points in B-PT-B. group, and 89.0 points in hamstring tendon group. There were no clinically significant results between two groups in Telos test, quadriceps atrophy, Lachman test, anterior drawer test and pivot shift test, but the incidences of anterior knee pain were lower in hamstring group. Four-stranded hamstring tendon graft showed enough stability and good functional outcome similar to that of patellar tendon graft, and had an advantage of quicker return of quadriceps function and less donor site morbidity.

  • PDF

COMPARISON OF POSITIONAL STABILITY BETWEEN RIGID FIXATION AND NONRIGID FIXATION IN ORTHOGNATHIC SURGERY (악교정 수술시 견고 및 비견고 고정에 따른 위치적 안정성에 대하 비교 연구)

  • Chu, Seong-Chai;Min, Byung-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.412-420
    • /
    • 1991
  • Seventeen rigid screw fixation and sixteen nonrigid wire fixation cases of mandibular sagittal slit ramus osteotomy were selected to compare postoperative dental and skeletal changes. A constructed horizontal plane was drawn seven degrees under sella-nasion plane and detailed cephalometirc assessment was applied to serial radiographic films taken before surgery($T_0$), immediately after surgery($T_1$), and at least six months after surgery($T_2$). Linear and angular positional changes were measured and analyzed statistically using paired t-test method and percent of positional changes(amount of post-op change/amount of intra-op change)${\times}100$. The results were as follows; 1. It was 29.4% in rigid fixation cases and 37.5% in nonrigid fixation cases comparing the postoperative positional change of more than 2mm at point B. So rigid fixation method was slightly more stable. 2. In nonrigid fixation cases, the positional change might be caused by incomplete bony union at the osteotomy site and soft tissue tension acting on this site. 3. In rigid fixation cases, the positional change might be caused by interaction between relapse tendency of protracted condyle-proximal segment and neighboring soft tissue tension.

  • PDF

Ankle Syndesmotic Injury (족근 관절 경비 인대 결합 손상)

  • Gwak, Heui-Chul;Kwon, Young-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.4
    • /
    • pp.187-194
    • /
    • 2011
  • Ankle injuries may involve the distal tibiofibular syndesmosis and can be associated with a variable degree of trauma to the soft tissue and osseous structures that play an important role in ankle joint stability. Ankle syndesmotic injury may occur solely as a soft tissue injury or in association with variable ankle fractures. Ankle syndesmotic injury does not necessarily lead to ankle instability; however, the coexistence of deltoid ligament injury critically destabilizes the ankle joint. The prevalence of these injuries may be higher than previously reported. The diagnosis of syndesmotic injury as not always easy because isolated ankle sprains may be missed in the absence of a frank diastasis and syndesmotic instability may be unnoticed in the presence of bimalleolar ankle fractures. Controversies arise at almost every phase of treatment includings : type of fixation(screw size, type of implant), number of cortices required for fixation and of need for hardware removal. Regardless of controversies, the most important goal should be restore and maintain the normal tibiofibular relationship to allow for healing of the ligamentous structures of the syndesmosis.

Poly(lactic acid)/Wood Flour/Montmorillonite Nanocomposites (II) : Thermal properties

  • Kim, Jin-Sung;Lee, Sun-Young;Doh, Geum-Hyun;Kang, In-Aeh;Yoon, Ho-Gyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.434-439
    • /
    • 2009
  • This study investigates the thermal properties of nanocomposites prepared from poly(lactic acid) (PLA), wood flour (WF) and montmorillonite (MMT) by melt compounding with a twin screw extruder. In order to enhance the mechanical properties of PLA/WF composites, maleic anhydride grafted PLA (MAPLA) is synthesized as a compatibilizer. MAPLA prepared in the laboratory is characterized using FR-IR. From SEM microphotographs, the presence of MAPLA has a positive effect on the mechanical properties of WF-reinforced PLA composites. The addition of WF/MAPLA into neat PLA increased the glass transition temperature ($T_g$). The addition of 1 to 5 wt% MMT into PLA/WF/MAPLA composite decreases the $T_g$. The cold crystallization temperature ($T_{cc}$) was decreased by the addition of MMT. The MMT could act as effective nucleating sites of PLA crystallization. The thermal stability evaluated by thermogravimetric analysis (TGA) is improved with the contents of MMT up to 3 wt%.