• 제목/요약/키워드: Screw plate

Search Result 185, Processing Time 0.032 seconds

Cement Augmentation of Dynamic Hip Screw to Prevent Screw Cut Out in Osteoporotic Patients with Intertrochanteric Fractures: A Case Series

  • Rai, Avinash Kumar;Goel, Rajesh;Bhatia, Chirag;Singh, Sumer;Thalanki, Srikiran;Gondane, Ashwin
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The purpose of this study is to describe a method of inserting cement in the femoral head before fixation with dynamic hip screw to prevent screw cut out due to osteoporosis and to evaluate its clinical outcome in these patients. Materials and Methods: In this prospective study, 30 patients aged 60 years and older with intertrochanteric fracture were included. Bone mineral density was measured. After reaming of the femoral head and neck with a triple reamer and polymethyl methacrylate, bone cement was introduced into the femoral head using a customized nozzle and a barrel fitted on a cement gun. A Richard screw was inserted and the plate was fixed over the femoral shaft. Patients were mobilized and clinical outcomes were rated using the Salvati and Wilson's scoring system. Results: More patients included in this study were between 66 and 70 years old than any other age group. The most common fracture according to the Orthopaedic Trauma Association classification was type 31A2.2 (46.7%). The T-score was found to be $-2.506{\pm}0.22$ (mean${\pm}$standard deviation); all patients were within the range of -2.0 to -2.8. The duration of radiological union was $13.67{\pm}1.77$ weeks. Salvati and Wilson's scoring at 12 months of follow up was $30.96{\pm}4.97$. The majority of patients were able to perform their normal routine activities; none experienced implant failure or screw cut out. Conclusion: Bone cement augmentation may effectively prevent osteoporosis-related hardware complications like screw cut out in elderly patients experiencing intertrochanteric fractures.

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF

Numerical Stress Analysis of bone plate System using 3-dimensional finite element method (3차원 유한 요소법을 이용한 골절판의 응력 해석)

  • Kim, Hyun-Su;Kwon, Young-Soo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.74-78
    • /
    • 1991
  • Conventional compression bone fracture plates sometimes cause osteoporosis under the plate due to their high rigidity which in turn transfer physiological load mostly through the plates and screws. In order to prevent the osteopenia we have designed a system which have a viscoelastic washer between plate and screw head. The washer is made of a biocompatible ploymer (untra high molecular weight polyethylene, UHMWPE). Three-dimensional finite element meshes of the human femur with the conventional and new concept bone plate ere generated and the comparative stress analyses are performed with static half-stance loading condition. The results of analyses showed that could reduce the stress shielding effect compared with the conventional plate.

  • PDF

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Mechanical Response of Changes in Design of Compression Hip Screws with Biomechanical Analysis (생체 역학적 분석에 의한 Compression Hip Screw의 디자인 요소에 대한 평가)

  • 문수정;이희성;권순영;이성재;안세영;이훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1172-1175
    • /
    • 2004
  • At present, CHS(Compression Hip Screw) is one of the best prosthesis for the intertrochanteric fracture. There is nothing to evaluate the CHS itself with the finite element analysis and mechanical tests. They have same ways of the experimental test of the ASTM standards. The purpose of this study is to evaluate the existing CHS and the new CHS which have transformational design factors with finite element analysis and mechanical tests. The mechanical tests are divided into compression tests and fatigue test for evaluating the failure load, strength and fatigue life. This finite element method is same as the experimental test of the ASTM standards. Under 300N of compression load at the lag screw head. There are less differences between Group (5H, basic type) and Group which has 8 screw holes. However, there are lots of big differences between Group and Group which is reinforced about thickness of the neck range. Moreover, the comparison of Group and Group shows similar tendency of the comparison of Group and Group . The Group is reinforced the neck range from Group. After the experimental tests and the finite element analysis, the most effective design factor of the compression hip screws is the reinforcement of the thickness, even though, there are lots of design factors. Moreover, to unite the lag screw with the plate and to analyze by static analysis, the result of this method can be used with experimental test or instead of it.

  • PDF

TREATMENT OF CONDYLE FRACTURE WITH RESORBABLE SCREW (흡수성 스크류를 이용한 하악과두 골절의 치료)

  • Yeo, In-Bum;Min, Seung-Ki;Oh, Sung-Hwan;Kwan, Kyung-Hwan;Choi, Sang-Moon;Park, Sang-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.559-564
    • /
    • 2006
  • According to the development of operation technique and biologic materials, oromaxillofacial surgery department have used many kinds of metal and biologic materials in ORIF and plastic surgery. In maxillofacial fracture, ORIF with metal plate and screw have short healing period and good prognosis. But ORIF with metal materials have many complications as maxillofacial abnormal growth, screw loosening, bone malunion. And metal materials have not used in infection site. The purpose of this study is to evaluate the clinical value of 10 condylar fracture patients operated with absorbable screw at Wonkwang university. Ten patients(8 males, 2 female, mean aged 28) who had mandibular condyle process fracture treated with PLLA implants(poly-l-lactide) was recalled for follow-up clinical and radiologic examination for 10 years. Mouth opening recorvered to more than 35mm and occlusion was stable in all patients. All fractured mandibular condyles showed anatomic good reduction and long-term stability with the use of resorbable miniplates and screw. Bone healing was satisfactory in all patients, and there was no evidence of abnormal resorption of condylar process.

Comparison of Radiologic and Clinical Results between Locking Compression Plate and Unlocked Plate in Proximal Humerus Fractures (근위 상완골 골절에서 잠김 압박 금속판과 비잠김 금속판 고정의 방사선학적 임상적 추시 결과 비교)

  • Kim, Jae-Hwa;Lee, Yun-Seok;Ahn, Tae-Keun;Choi, Jung-Pil
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • Purpose: The purpose of this study is to compare the results of using a locking compression plate and an unlocked plate for treating proximal humeral fractures. Materials and Methods: This study was based on 20 patients who underwent plate fixation for proximal humeral fractures out of the 87 patients with proximal humeral fractures and who were admitted from 2003 to 2007 in our hospital. Of the 20 patients, 10 were treated with a locking compression plate and the other 10 were treated with an unlocked plate. Each group was evaluated according to the humeral neck shaft angle, the period until bony union, the complications and the Constant score. The humeral neck shaft angle was based on plain x-rays taken immediately after the operation and at 6 months postoperatively. The Constant score was evaluated on the last visit to our clinic. Results: There was no significant statistical difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. Yet, there were three cases of screw migration in the unlocked plate group. Conclusion: There was no significant difference between the two groups in terms of the neck shaft angle, the period until bony union and the Constant score. The locking compression plate is considered to achieve more effective fixation for proximal humerus fractures because there were less complications such as screw migration.

Three-dimensional finite element analysis of the stress distribution and displacement in different fixation methods of bilateral sagittal split ramus osteotomy

  • Yun, Kyoung In;Cho, Young-Gyu;Lee, Jong-Min;Park, Yoon-Hee;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.271-275
    • /
    • 2012
  • Objectives: This study evaluated a range of fixation methods to determine which is best for the postoperative stabilization of a mandibular osteotomy using three-dimensional finite element analysis of the stress distribution on the plate, screw and surrounding bone and displacement of the lower incisors. Materials and Methods: The model was generated using the synthetic skull scan data, and the surface model was changed to a solid model using software. Bilateral sagittal split ramus osteotomy was performed using the program, and 8 different types of fixation methods were evaluated. A vertical load of 10 N was applied to the occlusal surface of the first molar. Results: In the case of bicortical screws, von-Mises stress on the screws and screw hole and deflection of the lower central incisor were minimal in type 2 (inverted L pattern with 3 bicortical repositioning screws). In the case of plates, von-Mises stress was minimal in type 8 (fixation 5 mm above the inferior border of the mandible with 1 metal plate and 4 monocortical screws), and deflection of the lower central incisor was minimal in types 6 (fixation 5 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws) and 7 (fixation 12 mm below the superior border of the mandible with 1 metal plate and 4 monocortical screws). Conclusion: Types 2 and 6 fixation methods provide better stability than the others.

CLINICAL EVALUATION OF TREATMENT OUTCOME OF PLATING TECHNIQUE OF FIXATION FOR MANDIBULAR CONDYLAR FRACTURE (하악 과두 골절의 관혈적 정복시 고정 방법에 따른 임상적 평가)

  • Son, Jung-Hee;Park, Ji-Hwa;Kim, Chin-Soo;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.2
    • /
    • pp.164-170
    • /
    • 2005
  • The purpose of this study was to compare a sample of patients who had condylar fractures treated with open reduction using different plating techniques, to evaluate which plating technique is useful for stable fixation for fractures of the mandibular condyle and to evaluate effectiveness of resorbable miniplate. There were 60 patients (41 males, 19 females) whose condylar fractures were treated with open reduction. Rigid fixation was performed with a single miniplate, double miniplate ot one miniplate & one microplate and single resorbable plate. All patients remained intermaxillary fixation for 1 week postoperatively. Active physiotherapy was started after 2 weeks postoperatively. Radiographic evaluation (plate fracture, plate bending, screw loosening, displacement of condyle etc.) was performed at pre-operative, immediate, 2 weeks, 1 month, 3 months, 6 months after surgery. Clinical evaluation included degree of mouth opening, occlusion, mandibular lateral excursion, infection and facial nerve paralysis. In radiographic evaluation, displacement of fractured condylar segment associated with plate bending or screw loosening were showed 6 cases and 3 cases for single miniplate system and resorbable miniplate system. There was no patients who have this problem on double miniplate system. The results revealed that the application of two miniplates were more recommendable than single miniplates. When we select resorbable miniplate system, we should consider the type of fractures, post-operative treatment protocol and surgical technique.