• Title/Summary/Keyword: Screw plate

Search Result 185, Processing Time 0.03 seconds

RIGID FIXATION BY MINIPLATE IN THE MANDIBULAR SAGITTAL SPLITRAMUS OSTEOTOMY. (하악골 시상골 골절단술시 MINIPLATE에 의한 RIGID FIXATION)

  • Cho, Byoung-Ouck;Lee, Youg-Chan;Yang, Yong-Seog;You, Ha-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.2
    • /
    • pp.48-54
    • /
    • 1990
  • This is a report of 4 cases of the surgical correction of mandibular prognathism with chief complaint of mastication difficulty, facial asymmetry and protrusive chin. We performed sagittal spit ramus osteotomy for the prognathism, we used the repositioning plate for conserving the condylar segment into its original position and fixed the osteotomized bone segments rigidly with adjustable monocortical plate. Intermaxillary fixation was performed during 2 weeks. As a results, we found the following advantage. 1. Rigid fixation effect like the fixation by the tandem screw. 2. Decreased postoprative swelling. 3. It is needless to do the stab incision for the transbuccal set instrument. 4. It is more convenient to perform the rigid fixation in the monocortical plate method than screw technique.

  • PDF

The Use of Special Washers in Bone Plates for Improved Impact-Absorbing Characteristics (충격흡수 특성의 향상을 위하 내고정용 특수 와셔에 관한 연구)

  • 김윤영;김장수
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.457-462
    • /
    • 1995
  • Unlike the usual bone plate and screw fracture fixation, an improved plate fixation method, which can transfer gradually physiological load to bones, is described. The key feature of the present method is to use washers between the plate and the screw. Bio-absorbable materials or non-ferrous materials with good damping characteristics are used to manufacture the washers. The purpose of this paper is to discuss potential advantages of the proposed method, and to show experimentally its improved impact-absorbing characteristics. Vibration experiments are carried out for pig femurs and cow tibias with and without the proposed washers. This experiments show that the washers can drop the first peak value suite substantially in the FRF plots. Although in-vivo experiments have not been conducted, the present fixation method appears to be a simple and effective alternative to the presently used method.

  • PDF

Ultrasonographic Diagnosis of Extensor Tenosynovitis Caused by Dorsal Screw Prominence after Volar Plate Fixation of Distal Radius Fracture: Case Report (원위 요골 골절의 수장측 금속판 고정술 후 발생한 신전건 활막염에 대한 초음파를 이용한 진단: 증례 보고)

  • Lim, Tae Kang;Kim, Sang Yeol;Kang, Hong Je;Hah, Dae Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.60-64
    • /
    • 2013
  • After volar locking plating of distal radius fracture, complications arising from unrecognized dorsally prominent screws penetrating the extensor compartments are increasingly reported. However, standard radiography and fluoroscopy may not adequately visualize screw lengths, because of complex shape of dorsal cortex of the distal radius. We presented case of ultrasonography diagnosis of extensor tenosynovitis caused by dorsal screw prominence after volar plate fixation of distal radius fracture.

  • PDF

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Applying tilt mechanism for high-resolution image acquisition (고해상도 영상 획득을 위한 틸트 메커니즘 적용 기법)

  • Song, Chun-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.31-37
    • /
    • 2014
  • In this paper, to compensate the degraded performance in high-resolution infrared sensor due to assembling error, the influence of each component was evaluated through the sensitivity analysis of lens assembly, axis mirror, and detector and also suggested detector tilt mechanism for compensation. 3 detector tilt mechanisms were investigated. The first one is 'Shim plate' method which is applying shim on installing plane. The second one is 'Tilting screw' method that is using tilt screw for adjusting detection plane. The last one is 'Micrometer head' method that is installing micrometer on detection plane and acquiring quantitative data. Based on the investigation result, 'Tilting screw' method was applied due to ease of user control, small volume, and real-time controllability, thereby we could acquire high-resolution infrared images. The research result shows that the tilting mechanism is necessary technology for the implementation of high-resolution infrared imaging system.

The Tangential Projection Method for Checking Existence and Nonexistence of Radius Groove Penetration of Screw after Distal Radius Fracture Operation Used the T-type Plate (T형 금속판을 이용한 요골 원위부 골절 수술 후 나사못의 요골구 관통 유무를 확인하기 위한 접선방향 촬영법)

  • Seo, Sun-Youl;Hong, Ki-Jang;Han, Man-Seok;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.335-340
    • /
    • 2010
  • This paper is about a projection method to check existence of radius groove penetration of screw after distal radius fracture operation using the T-type plate. Angle of Radius groove was analyzed by fifty one CT images that contains patients' wrist and twenty cases of radius specimens. After making radius phantom by plaster, we set the screw so that it penetrated 2.4 mm depth of radius groove. Then, we projected the phantom by X-ray in change of the elevation and supination angle of distal radius by 5 degree interval on 0~30 degree. The average value of groove angle in the wrist CT images was 14.4 degree and the radius specimens was 16.3 degree. Screws penetrating radius groove of the phantom have different lengths according to elevation angle and supination angle. Consequently, in order to confirm existence and nonexistence of radius groove penetration of the screw in tangential projection after distal radius fracture operation using the T-type plate, we recommend 5 degree of elevation angle and 20 degree of supination angle.

MANUFACTURE AND CHARACTERISTICS OF SNACK-TYPE PRODUCTS CONTAINING MEAT AND STARCH

  • Cho, Soo-Hyun
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 1997.06a
    • /
    • pp.19-39
    • /
    • 1997
  • Extrusion conditions were optimized for blends of ground lamb and starch using a single-screw extruder for the purpose of producing expanded snack-type products. A central composite rotatable response surface methodology(RSM) design was used with variation in feed moisture, process temperature, and screw speed. The three variables significantly affected one or more of the measured physical properties of extrudates. The optimum conditions for minimum shear force values were 26.5% feed moisture, $148^{\circ}C$ process temperature, and 134 rpm screw speed. Lean ground beef, chicken, goat, lamb or mutton was blended with corn starch, and extruded at the optimum condition established from RSM experiments. Physical/rheological properties were generally similar, water activity was low (<0.12) and total aerobic plate counts were <10 for all products. Extrudates containing chicken had the highest ratio of polyunsaturated fatty acids to saturated fatty acids, whereas those containing beef had the highest ratio of monounsaturated fatty acids to saturated fatty acids. Sensory data indicated that texture was acceptable and flavor characteristics were not different among the products.

  • PDF

Development of Devices of the Diversion Gate in Irrigation Canal (용수로 분수문 개폐장치 개발)

  • Jeon, Jong-Gil;Kim, Kyung-Won;Lee, In-Bok;Chun, Man-Bok
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.223-226
    • /
    • 2003
  • Devices of diversion gate used at irrigation canal, as a irrigation structures of agriculture, have shown serious problems such as corrosion, defect, inconvenience of operation, etc. Accordingly, handy devices of diversion gate have been developed and then tested in the laboratory. The operating types of the prototype were a rack-and-pinion type, an improved screw type that only gate plate was moved up and down while the screw axis was unmoved, and a remote control type which can be controlled from 50m away using a remote control system. Those 3 types were developed, and the improved screw type was shown the best operation through the laboratory tests.

  • PDF

Delayed bladder perforation due to screw loosening after pelvic ring injury surgery: a case report

  • Shon, Hyun-Chul;Kang, Ho-Won;Lim, Eic-Ju;Yang, Jae-Young
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.51-55
    • /
    • 2022
  • Pelvic ring injuries have high mortality and morbidity rates, and they are difficult to treat because accompanying injuries to the pelvic organs, genitourinary organs, and neurovascular tissues are common. Genitourinary injuries are common comorbid injuries that have been reported to occur in 5% to 6% of all pelvic ring injuries. However, these injuries usually occur simultaneously with the pelvic ring injury, whereas relatively little research has dealt with genitourinary injuries that occur after treatment of a pelvic ring injury. To the best of our knowledge, only three cases of delayed bladder perforation due to screw loosening after symphyseal plate fixation in anterior pelvic ring injury have been reported worldwide, and no such cases have yet been reported in Korea. Since the authors experienced this very rare complication after pelvic ring surgery, we report this case along with a literature review.

Optimization of Screw Pumping System (SPS) for Mass Production of Entrapped Bifidus

  • Ryu, Ji-Sung;Lee, Yoon-Jong;Choi, Soo-Im;Lee, Jae-Won;Heo, Tae-Ryeon
    • Food Science and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.566-571
    • /
    • 2005
  • Process of screw-pumping system (SPS) was optimized for mass production of encapsulated bifidus. SPS entrapment device was composed of feeding component, with optimized nozzle size and length of 18G (0.91 cm) and 4 mm, respectively, screw pump, and 37-multi-nozzle. Screw component had five wing turns [radius (r)=26 to 15 mm] from top to bottom of axis at 78-degree angle from middle of the screw, and two wings were positioned at screw edge to push materials toward nozzle. For nozzle component, 37 nozzles were attached to 20-mm round plate. Air compressor was attached to SPS to increase productivity of encapsulated bifidus. This system could be operated with highly viscous (more than 300 cp) materials, and productivity was higher than $1128\;{\pm}\;30\;beads/min$. Viability of encapsulated bifidus was $5.45\;{\times}\;10^8\;cfu$/bead, which is superior to that of encapsulated bifidus produced by other methods ($2.51{\times}10^8\;cfu$/bead). Average diameter of produced beads was $2.048\;{\pm}\;0.003\;mm$. Survival rate of SPS-produced encapsulated bifidus was 90% for Simulator of the Human Intestinal Microbial Ecosystem test and 88% in fermented milk (for 14 days). These results show SPS is effective for use in development of economical system for mass production of viable encapsulated bifidus.