• Title/Summary/Keyword: Screw perforation

Search Result 10, Processing Time 0.019 seconds

Cervical Pedicle Screw Insertion Using the Technique with Direct Exposure of the Pedicle by Laminoforaminotomy

  • Jo, Dae-Jean;Seo, Eun-Min;Kim, Ki-Tack;Kim, Sung-Min;Lee, Sang-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.459-465
    • /
    • 2012
  • Objective : To present the accuracy and safety of cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy. Methods : We retrospectively reviewed 12 consecutive patients. A total of 104 subaxial cervical pedicle screws in 12 patients had been inserted. We also assessed the clinical and radiological outcomes and analyzed the direction and grade of pedicle perforation (grade 0: no perforation, 1: <25%, 2: 20% to 50%, 3: >50% of screw diameter) on the postoperative vascular-enhanced computed tomography scans. Grade 2 and 3 were considered as incorrect position. Results : The correct position was found in 95 screws (91.3%); grade 0-75 screws, grade 1-20 screws and the incorrect position in 9 screws (8.7%); grade 2-6 screws, grade 3-3 screws. There was no neurovascular complication related with cervical pedicle screw insertion. Conclusion : This technique (technique with direct exposure of the pedicle by laminoforaminotomy) could be considered relatively safe and easy method to insert cervical pedicle screw.

Delayed bladder perforation due to screw loosening after pelvic ring injury surgery: a case report

  • Shon, Hyun-Chul;Kang, Ho-Won;Lim, Eic-Ju;Yang, Jae-Young
    • Journal of Trauma and Injury
    • /
    • v.35 no.1
    • /
    • pp.51-55
    • /
    • 2022
  • Pelvic ring injuries have high mortality and morbidity rates, and they are difficult to treat because accompanying injuries to the pelvic organs, genitourinary organs, and neurovascular tissues are common. Genitourinary injuries are common comorbid injuries that have been reported to occur in 5% to 6% of all pelvic ring injuries. However, these injuries usually occur simultaneously with the pelvic ring injury, whereas relatively little research has dealt with genitourinary injuries that occur after treatment of a pelvic ring injury. To the best of our knowledge, only three cases of delayed bladder perforation due to screw loosening after symphyseal plate fixation in anterior pelvic ring injury have been reported worldwide, and no such cases have yet been reported in Korea. Since the authors experienced this very rare complication after pelvic ring surgery, we report this case along with a literature review.

Pedicle Morphometry for Thoracic Screw Fixation in Ethnic Koreans : Radiological Assessment Using Computed Tomographic Myelography

  • Choi, Yang-Soo;Kim, Young-Jin;Yi, Hyeong-Joong;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.317-321
    • /
    • 2009
  • Objective : In the thoracic spine, insertion of a pedicle screw is annoying due to small pedicle size and wide morphological variation between different levels of the spine and between individuals. The aim of our study was to analyze radiologic parameters of the pedicle morphometry from T1 to T8 using computed tomographic myelography (CTM) in Korean population. Methods : For evaluation of the thoracic pedicle morphometry, the authors prospectively analyzed a consecutive series of 26 patients with stable thoracic spines. With the consent of patients, thoracic CTM were performed, from T1 to T8. We calculated the transverse outer diameters and the transverse angles of the pedicle, distance from the cord to the inner cortical wall of the pedicle, and distance from the cord to the dura. Results : Transverse outer pedicle diameter was widest at T1 ($7.66{\pm}2.14\;mm$) and narrowest at T4 ($4.38{\pm}1.55\;mm$). Transverse pedicle angle was widest at T1 ($30.2{\pm}12.0^{\circ}$ and it became less than $9.0^{\circ}$ below T6 level. Theoretical safety zone of the medial perforation of the pedicle screw, namely, distance from the cord to inner cortical wall of the pedicle was more than 4.5 mm. Conclusion : Based on this study, we suggest that the current pedicle screw system is not always suitable for Korean patients. Computed tomography is required before performing a transpedicular screw fixation at the thoracic levels.

Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process

  • Sung, Min-Jae;Kim, Kyoung-Tae;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2018
  • Objective : Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. Methods : We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age${\pm}$standard deviation, $45.8{\pm}14.2years$). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. Results : The mean width of the apical dens tip was $9.6{\pm}1.1mm$. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were $39.2{\pm}2.6mm$ and $36.6{\pm}2.4mm$. The safe margin beyond apical dens tip to ventral dura was $7.7{\pm}1.7mm$. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to $2.1{\pm}3.2mm$, which was statistically significant (p<0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. Conclusion : Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

Improvement of fibrosed scar tissue elongation using self-inflatable expander

  • Jung, Gyu-Un;Kim, Jin-Woo;Pang, Eun-Kyoung;Kim, Sun-Jong
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.501-512
    • /
    • 2016
  • We evaluated a self-inflatable osmotic tissue expander for its utility in creating sufficient soft tissue elongation for primary closure after bone grafting. Six patients with alveolar defects who required vertical augmentation of >6 mm before implant placement were enrolled. All had more than three prior surgeries, and flap advancement for primary coverage was restricted by severely fibrosed scars. Expanders were inserted beneath the flap and fixed with a screw. After 4 weeks, expander removal and bone grafting were performed simultaneously. A vertical block autograft and guided bone regeneration and distraction osteogenesis were performed. Expansion was sufficient to cover the grafted area without additional periosteal incision. Complications included mucosal perforation and displacement of the expander. All augmentation procedures healed uneventfully and the osseous implants were successfully placed. The tissue expander may facilitate primary closure by increasing soft tissue volume. In our experience, this device is effective, rapid, and minimally invasive, especially in fibrous scar tissue.

  • PDF

Indirect Reduction Technique in Proximal Humeral Fractures Stabilized by Locking Plates

  • Rhee, Yong Girl;Cho, Nam Su;Cha, Sang Won;Moon, Seong Cheol;Hwang, Sang Phil
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.2-9
    • /
    • 2014
  • Background: Indirect reduction technique offers a valid option in the treatment of proximal humerus fracture. The purpose of this study is to evaluate the functional outcome and the complication rate after indirect reduction and internal fixation of unstable proximal humeral fractures with use of a locking plate. Methods: Twenty four patients with acute proximal humerus fracture were managed with indirect reduction and internal fixation with a locking plate. The mean follow-up period was 15.5 months. Results: The anatomical reduction of the medial cortex buttress was seen in 16 patients (66%) of the Group A and the non-anatomical reduction was seen in 8 patients (33%) of the Group B. Mean union time was $3.2{\pm}1.9$ months; it was $2.2{\pm}0.6$ months in the Group A and $5.3{\pm}2.2$ months in the Group B (p < 0.05). In our series, there were 6 cases of complications and these include 2 cases of varus malunion, 2 cases of shoulder stiffness, 1 case of heterotrophic ossification, 2 cases of screw perforation and 1 case of impingement. Conclusions: We conclude from our studies that indirect reduction and internal fixation using locking plate for acute proximal humerus fracture can give good results with bony union and predictable good overall functional outcome. If the medial cortex buttress is well maintained, a better anatomical reduction would be achieved, the union would be prompted, the pain would be further reduced and the range of the motion would be recovered more promptly.

Sound Absorption Characteristic of Resonator by Hole Position and Wood Species (천공 위치와 수종에 따른 공명기의 흡음특성)

  • Hwang, Kweonhwan;Kim, Gun-Hyung;Park, Byungsu;Park, Jung-Hwan;Byeon, Hee-Seop;Lee, Won-Hee
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.9-16
    • /
    • 2008
  • Ribbed birch (Betula costata Trautv.), Japanese larch (Larix kaempferi (Lamb.) Carr.), and tulip tree (Liriodendron tulipifera L.), were used as experimental specimens to measure the sound absorption coefficient with various resonator types, regular resonator (Type-R), eccentric resonator (Type-E), aligned resonator (Type-A), and screwed resonator (Type-S). Resonators consisted of the simple perforation by hand drilling. Sound absorption performances of the resonators installed perforations were better than those of untreated specimens. They were varied with the resonator's type and wood species. Increased area by a wood screw gave no significant change on the sound absorption.

A RETROSPECTIVE EVALUATION OF IMPLANT INSTALLATION WITH MAXILLARY SINUS AUGMENTATION BY LATERAL WINDOW TECHNIQUE (측방접근법을 이용한 상악동거상술 후 임프란트 식립에 대한 후향적 평가)

  • Ki, Se-Il;Yu, Min-Gi;Kim, Young-Joon;Kook, Min-Suk;Park, Hong-Ju;Shet, Uttom Kumar;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.457-464
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the clinical results of implants which were installed with maxillary sinus elevation by using lateral window technique. Materials and methods: We performed the maxillary sinus elevation by lateral window technique to 87 patients who visited Dept. of Oral & Maxillofacial Surgery, Chonnam National University Hospital from January, 2003 to January, 2007. When the residual bone height was from 3 mm to 7 mm, the sinus elevation and simultaneous implant installation was mostly performed. When the residual bone height was less than 3 mm, the sinus elevation was performed and the delayed implant installation was done after 5 or 6 months. No artificial membranes were used for coverage of the lateral bony window site and freeze dried fibrin sealant was applied to the grafted bone. The mean follow-up period was 28.5 months (ranged from 10 months to 48 months) Results: 1. Unilateral sinus elevations were performed in 51 patients and bilateral sinus elevations were performed in 36 patients. And the total number of sinus elevation procedure was 123 cases. 2. The sinus elevation and simultaneous implant installation was performed in 89 sinuses and 249 implants were installed. The sinus elevation and delayed implant installation was performed in 44 sinuses and 141 implants were installed. The total number of implants were 390 in 133 sinuses. The average healing period after sinus elevations was 6.1 months in delayed implant installation. 3. Only autogenous bone, autogenous bone mixing with allografts or autogenous bone mixing with xenografts were used as graft materials. 4. The average period from first surgery to second surgery was about 7.2 months. 5. Some patients complications, such as perforation of sinus membrane, swelling, infection and exposure of cover screw. Two implants were removed in the infected sinus. 6. The survival rate of implants with maxillary sinus elevation by lateral window technique was 99.5% and the success rate of implants was 95.1%. Conclusions: These results indicated that the implants which were installed with maxillary sinus elevation by lateral window technique showed high survival and success rates.

A RETROSPECTIVE MULTICENTER CLINICAL STUDY OF INSTALLED US II / SS II IMPLANTS AFTER MAXILLARY SINUS FLOOR ELEVATION (상악동저 거상술 후 Osstem Implant (US II / SS II)의 다기관 후향적 임상연구)

  • Kook, Min-Suk;Park, Hong-Ju;Kim, Su-Gwan;Kim, Young-Kyun;Cho, Yong-Seok;Choi, Gab-Lim;Oh, Young-Hak;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.341-349
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate the $Osstem^{(R)}$ implants (US II/SS II implants) through the retrospective study for the clinical success rate during the installation of the $Osstem^{(R)}$ implants (US II/SS II implants) by using of the procedures of maxillary sinus floor elevation. Materials and methods: The current study was researched in the 6 medical institutions: Chonnam National University, Chosun University, Pusan DaeDong Hospital, Bundang Seoul National University Hospital, Ap-Seon Clinic, and All Clinic. Based on the total number of 116 patients whose treatment was the installation of the US II/SS II implants with the procedures of the maxillary sinus floor elevation, they were conferred on the dental records of the patients under the joint consultation of the 6 medical institutions. On the dental recording charts, there were included in as the following; the name of the institutions, gender, age, with or without smoking or drinking, with or without the generalized diseases, the height of the alveolar bone on the operational sites, elapsed edentulous state period, the state of the opposed or adjacent teeth, the methods of the maxillary sinus floor elevation, secondary time period for surgery, the lengths, types, and diameters of implants, with or without bone transplantation or the types of bone, postoperative current bone height, current adjacent soft tissue state of the implants, with or without the success of the installations of the implants. We have done our survey with the clinical and radiolographical examinations and dental questionaries. The success and survival rate of the implants was evaluated. Results 1. Total number of the patients with the installation of the US II implants were 62. The 252 numbers of US II implants were installed on the 89 maxillary sinuses. The patient's mean age was 54.1 years old and there were 36 men and 27 women. 2. Total number of patients with the installation of SS II implant were 57. The 165 numbers of SS II implants were planted on the 80 maxillary sinuses. Their mean age was 48.7 years old and there were 37 men and 20 women. 3. The follow-up period was 30.7 months(21-49 mon) on average. The vertical bone loss of installed implants after the procedures of the maxillary sinus elevation was 1.1 mm on average in SS II and 1.3 mm on average in US II. There existed no statistical significance on each group. The mean enlarged bone height after the maxillary sinus floor elevation was 8.2 mm. 4. For the procedures of the maxillary sinus elevation, the Lateral approach technique occupied 87.1%, which was the most used one. In addition, the most frequently used transplanted bone was autogenous bone only which was 72.7% during the maxillary sinus floor elevation. 5. The complication of maxillary sinus floor elevation were perforation of sinus membrane, disesthesia on doner site, exposure of cover screw and exposure of maxillar bone. 6. The survival rate of US II and SS II after maxillary sinus floor elevation was 99.2% and 95.8%, respectively. And the success rate of US II and SS II after maxillary sinus floor elevation was 97.6% and 89.7%, respectively. Conclusion : On the evaluation of the analysis of our study, both US II and SS II implants showed the excellent clinical results by use of the procedures of maxillary sinus floor elevation.