• 제목/요약/키워드: Screw fracture

검색결과 332건 처리시간 0.027초

Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads

  • Jung, Da-Un;Chung, Chae-Heon;Son, Mee-Kyoung;Choe, Han-Cheol
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.283-291
    • /
    • 2015
  • The purpose of this study was to investigate effects of TiN coating on the fatigue fracture of dental implant system with various cyclic loads. TiN coated abutment screw, the fixture, and abutment of internal hex type were prepared for fatigue test. The fatigue test was carried out according to ISO 14801:2003(E) using tensile and compression tester with repeated load from 30% to 80% of static fracture force. Morphology and fractured surface was observed by field emission scanning electron microscope(FE-SEM) and energy dispersive X-ray spectroscope(EDS). The fracture cycle drastically decreased as repeated load increased. Especially, in the case of TiN-coated abutment screw, fracture cycle increased compared to non-coated abutment screw. The fatigue crack was propagated fast as repeated load increased. The plastic deformation region decreased, whereas, cleavage fracture region increased as repeated load increased.

Lag Screw Fixation of a Slab Fracture in the Third Carpal Bone in a Korean Racehorse

  • Kim, Yeong-Hun;Cho, In Ho
    • 한국임상수의학회지
    • /
    • 제37권4호
    • /
    • pp.217-222
    • /
    • 2020
  • A 3-year-old male Thoroughbred serving as a Korean racehorse named RAON PORTEOUS presented with acute lameness concomitant with edema and fever in the right carpal joint after completing a horse race. Through radiological examination using lateromedial oblique, flexed lateromedial oblique and dorsopromixal-dorsodistal oblique views, the horse was diagnosed with a slab fracture in the 3rd carpal bone of right forelimb. The fracture was surgically approached and corrected by applying 4.5 mm leg screw fixation during surgery. At eight months post-surgery, the horse was able to return to racing and has had successful racing performances with two wins and several prizes in the last 8 months. This is the first reported case of the successful use of lag screw fixation surgery in Korea with the horse showing complete recovery from a severe injury that is often considered fatal in a racehorse.

불안정성 흉·요추부 골절에 대한 단 분절 척추경 나사못 고정술 및 추체 보강 성형술 - 예 비 보 고 - (Short Segment Pedicle Screw Fixation with Augmented Intra-Operative Vertebroplasty in Unstable Thoraco-Lumbar Fracture - Preliminary Report -)

  • 김영우;오성한;윤도흠;진동규;조용은;김영수
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권11호
    • /
    • pp.1271-1277
    • /
    • 2001
  • Objectives : Since vertebroplasty has been introduced, we performed short segment pedicle screw fixation with augmented intra-operative vertebroplasty in patients with unstable thoraco-lumbar fracture. Our intentions are to demonstrate the efficacy and indication of this new technique compare to conventional methods. Material and Methods : The surgery comprised of pedicle screw fixations on one level above and below the fracture site, and the fractured level itself, if pedicle is intact, and intra-operative vertebroplasty under the fluoroscopic guide with in-situ postero-lateral bone graft. Also, in cases of bone apposition, we removed those with small impactor through a transfascetal route. During the last 2 years, we performed in seven(7) unstable thoraco-lumbar fracture patients who consisted of two different characteristics, those four(4) with primary or secondary osteoporosis and three(3) of young and very healthy. All patients were followed clinically by A.S.I.A. score and radiography. Results : Mean follow up period was 14 months. We observed well decompressed state via transfascetal route in cases of bone fragments apposition and no hardware pullout in osteoporotic cases, no poly-methyl-methacrylate (PMMA) leakage through the fracture sites into the spinal canal, and no kyphotic deformities in both cases during follow-up periods. All patients demonstrated solid bony fusion except one following osteoporotic compression fracture on other sites. Conclusions : In the management of unstable thoraco-lumbar fracture, we believe that this short segment pedicle screw fixation with augmented intra-operative vertebroplasty reduce the total length or levels of pedicle screw fixation without post-operative kyphotic deformity.

  • PDF

스프링 체결나사의 응력부식균열 수명예측 (Stress Corrosion Cracking Lifetime Prediction of Spring Screw)

  • 고승기;류창훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.7-12
    • /
    • 2004
  • A lifetime prediction of holddown spring screw in nuclear fuel assembly was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure and to predict the stress corrosion cracking life of the screw, a stress analysis of the top nozzle spring assembly was done using finite element analysis. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Normalized stress intensity factors for PWSCC life prediction was proposed. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.78 years, which was fairly close to the actual service life of the holddown spring screw.

  • PDF

Short Segment Screw Fixation without Fusion for Unstable Thoracolumbar and Lumbar Burst Fracture : A Prospective Study on Selective Consecutive Patients

  • Kim, Hee-Yul;Kim, Hyeun-Sung;Kim, Seok-Won;Ju, Chang-Il;Lee, Sung-Myung;Park, Hyun-Jong
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권4호
    • /
    • pp.203-207
    • /
    • 2012
  • Objective: The purpose of this prospective study was to evaluate the efficacy and safety of screw fixation without bone fusion for unstable thoracolumbar and lumbar burst fracture. Methods: Nine patients younger than 40 years underwent screw fixation without bone fusion, following postural reduction using a soft roll at the involved vertebra, in cases of burst fracture. Their motor power was intact in spite of severe canal compromise. The surgical procedure included postural reduction for 3 days and screw fixations at one level above, one level below and at the fractured level itself. The patients underwent removal of implants 12 months after the initial operation, due to possibility of implant failure. Imaging and clinical findings, including canal encroachment, vertebral height, clinical outcome, and complications were analyzed. Results: Prior to surgery, the mean pain score (visual analogue scale) was 8.2, which decreased to 2.2 at 12 months after screw fixation. None of the patients complained of worsening of pain during 6 months after implant removal. All patients were graded as having excellent or good outcomes at 6 months after implant removal. The proportion of canal compromise at the fractured level improved from 55% to 35% at 12 months after surgery. The mean preoperative vertebral height loss was 45.3%, which improved to 20.6% at 6 months after implant removal. There were no neurological deficits related to neural injury. The improved vertebral height and canal compromise were maintained at 6 months after implant removal. Conclusion: Short segment pedicle screw fixation, including fractured level itself, without bone fusion following postural reduction can be an effective and safe operative technique in the management of selected young patients suffering from unstable burst fracture.

잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석 (Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate)

  • 권경제;조명래;오종건;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권3호
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

족관절 골절과 동반된 전하 경비 인대 견열 골절의 치료 (Treatment of Anteroinferior Tibiofibular Ligament Avulsion Fracture Accompanied with Ankle Fracture)

  • 정형진;배서영;김만영
    • 대한족부족관절학회지
    • /
    • 제15권1호
    • /
    • pp.13-17
    • /
    • 2011
  • Purpose: To evaluate the clinical results of anteroinferior tibiofibular ligament avulsion fracture accompanied ankle fractures treated with anatomical reduction and internal fixation. Materials and Methods: From January 2007 to April 2010, 30 cases with anteroinferior tibiofibular ligament avulsion fracture that treated with anatomical reduction and internal fixation were analyzed. The average follow-up period was 26 months (minimum 6 months). We have reviewed the bony union, complication and subjective satisfaction according to the fracture classification and method of internal fixation. Results: Among 30 cases, 28 cases were occurred in Lauge-Hansen classification supination-external rotation type, one case was fracture-dislocation and one case was Maisonneuve fracture. We have performed internal fixation with Mini screw in 11 cases, K-wire in 10 cases, repair in six cases and Mini screw & K-wire in three cases. In all cases bony union was completed. two cases in Mini screw, one case in K-wire, two cases in repair and one case in Mini screw & K-wire revealed LOM of ankle joint. Skin irritation and superficial peroneal nerve irritation happened in one case each. Other cases show good subjective satisfaction. Conclusion: Anteroinferior tibiofibular ligament avulsion fracture accompanied with ankle fracture is a good clinical outcome with internal fixation. So we should not miss out the anteroinferior tibiofibular ligament avulsion fracture in radiologic evaluation or operation room.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

치과용 임플란트 지대주 나사 구조에 관한 연구 (Characteristics of Abutment Screw Structure for Dental Implant)

  • 송종법;최일경;정효경;권순홍;권순구;박종민;김종순;정성원;최원식
    • 한국산업융합학회 논문집
    • /
    • 제20권2호
    • /
    • pp.169-176
    • /
    • 2017
  • Dental implants are required to have biomechanical functions and biostability in order to perform authoring, pronunciation, and aesthetic functions in the oral cavity. In terms of biostability, pure titanium for medical have good biostability and no rejection in the alveolar bone. with appropriate strength in terms of strength as well as biocompatibility. In recent years, various surgical methods and devices have been developed to improve the convenience and safety of the procedure. However, as the number of procedures increases, the screw loosening of the abutment screw connecting the artificial root and the abutment There are many reports of artificial root and abutment fracture. Fig. 1 is an example of a case where the upper part of the abutment screw is arbitrarily modified to remove the abutment by the abutment fracture due to the loosening of the abutment screw. The fundamental cause of abduction of the abutment screw is caused by the slight movement due to the lowering of the retention force of the abutment screw. It is necessary to minimize loosening of the abutment screw to avoid problems such as fracture during the period of using the implant. The purpose of this study is to investigate the structure of the abutment screw to prevent the loosening of the abutment screw by forming 0.5mm slot.

제1,2경추골절의 치료 (Treatment of Atlantoaxial Fractures)

  • 진성철;김상진
    • Journal of Trauma and Injury
    • /
    • 제19권2호
    • /
    • pp.164-172
    • /
    • 2006
  • Background: The authors conducted a retrospective study to evaluate the mechanism of injury, the surgical techniques, the clinical features, the combined injuries, the treatment results, and the surgical complications in patients with atlantoaxial fracture/subluxations. Methods: The authors reviewed 71 cervical fracture/dislocations during a four-year period from September 2002 to August 2006. Among them, there were twenty one C1,2 fracture/subluxations. There were thirteen men (mean age : 43.5 years) and eight women (mean age : 50 years). Their follow-up period was at least 6 months, and the mean follow-up period was 9.6 months. Gardner-Wells tongs traction was used in all patients immediately on presentation. Surgical treatment was performed, depending on the pathologic conditions. Results: Of all 21 cases, 14 cases were injured in motor vehicle accidents, 5 were falls, and 2 were miscellaneous. There were four C1 fracture (5.6%), fourteen C2 fracture (66.7%), one C1 and 2 combined fracture (4.8%), and one C1-2 subluxation (4.8%). The C1 fractures in our series were classified as two Jefferson's fractures and two C1 lateral mass fracture. The C2 fractures were classified as one odontoid type I fracture, two odontoid type II fractures, five odontoid type III fractures, one hangman's fracture, and four C2 body tear-drop fractures. Atlantoaxial fractures were associated with six (28.6%) head injuries, four (19.0%) other spinal injuries, two (9.5%) chest injuries, and three (14.3%) spinal cord injuries. Surgical treatment was performed in nine cases, which included anterior odontoid screw fixation in two cases, transarticular screw fixation with iliac bone graft in one case, posterior fixation by using C2 pedicle screw and C3 lateral mass screw in three cases, lateral mass screw fixation C1-2 with iliac bone graft in one case, O(occipito)-C1-3-4 screw fixation in one case, posterior C2-3 wiring with allograft in one case, and halo vest in six cases. Conservative management was used in the rest of the patients in our trials. Bone fusion was complete in all cases. There were no operation-related complication, except one pin site infection in the case of halo vest. Conclusion: In this study, the choice of appropriate treatment according to the fracture types resulted in safe and effective management of unique atlantoaxial fracture/subluxations.