• Title/Summary/Keyword: Screw diameter

Search Result 193, Processing Time 0.025 seconds

Pedicle Morphometry for Thoracic Screw Fixation in Ethnic Koreans : Radiological Assessment Using Computed Tomographic Myelography

  • Choi, Yang-Soo;Kim, Young-Jin;Yi, Hyeong-Joong;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.317-321
    • /
    • 2009
  • Objective : In the thoracic spine, insertion of a pedicle screw is annoying due to small pedicle size and wide morphological variation between different levels of the spine and between individuals. The aim of our study was to analyze radiologic parameters of the pedicle morphometry from T1 to T8 using computed tomographic myelography (CTM) in Korean population. Methods : For evaluation of the thoracic pedicle morphometry, the authors prospectively analyzed a consecutive series of 26 patients with stable thoracic spines. With the consent of patients, thoracic CTM were performed, from T1 to T8. We calculated the transverse outer diameters and the transverse angles of the pedicle, distance from the cord to the inner cortical wall of the pedicle, and distance from the cord to the dura. Results : Transverse outer pedicle diameter was widest at T1 ($7.66{\pm}2.14\;mm$) and narrowest at T4 ($4.38{\pm}1.55\;mm$). Transverse pedicle angle was widest at T1 ($30.2{\pm}12.0^{\circ}$ and it became less than $9.0^{\circ}$ below T6 level. Theoretical safety zone of the medial perforation of the pedicle screw, namely, distance from the cord to inner cortical wall of the pedicle was more than 4.5 mm. Conclusion : Based on this study, we suggest that the current pedicle screw system is not always suitable for Korean patients. Computed tomography is required before performing a transpedicular screw fixation at the thoracic levels.

Effect of Combining Wood Particles and Wire Net on the Physical Properties of Board (목재(木材)파티클과 철강결체(鐵鋼結締)가 보오드의 물리적(物理的) 성질(性質)에 미치는 영향(影響))

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.3-26
    • /
    • 1985
  • The object of this study was to investigate the effects on physical and mechanical properties of wood particle and sawdust board combined with wire net. Conventional forming, press-lam, and veneer comply boards combining one to four wire net sheets were made from wood particle and sawdust with different spacings (8, 10, 12, and 18 Mok) and different wire diameters (0.35, 0.50, and 0.80mm) composing wire net. They were compared and analyzed statistically with specific gravity, thickness swelling, length swelling, bending properties (modulus of rupture, modulus of elasticity, work to proportional limit, and total work), internal bonding strength, and screw holding strength between wood particle and sawdust boards. The results obtained at this study as cording to the discussions might be concluded as follows; 1. In specific gravity, both particle and sawdust boards by press-lam method were higher than by conventional forming and veneer comply method, and the boards containing more wire net sheets also showed higher value. But the wire net spacings(Mok) had no influence on specific gravity. In general, particle board showed higher specific gravity than sawdust board. Veneer comply board showed lowest specific gravity values. 2. Both particle and sawdust boards by press-lam method was slightly lower than by conventional forming and veneer comply method in thickness swelling. The sawdust board containing 8, 12. and 18 Mok wire net showed lower thickness swelling than the corresponding particle board, but both sawdust and particle boards containing the T8 and 10 Mok wire net showed higher and similar thickness swelling. 3. Both particle and sawdust boards containing wire net showed no difference in MOR and MOE of bending. Comply board was the highest and particle board showed slightly higher than sawdust board in MOR and MOE values. 4. In work to proportional limit and total work in bending, both particle and sawdust boards containing thicker wire diameter and more wire net sheets showed higher value. From these facts, it is conceivable that boards with thicker wire diameter and more wire net sheets show increasing resistance against external force. But there was no significant difference between particle and sawdust borads. 5. In resistance against delamination (internal bonding strength), both sawdust and particle boards containing wire net showed lower value than control, and also showed decreasing tendency with more number of wire net sheet composed. Particle board showed higher resistance against delamination than sawdust board. 6. In screw holding strength, sawdust board containing thicker wire diameter and more wire net sheets showed higher value, but particle board by press-lam method was higher than by conventional forming and veneer comply method. Screw holding strength of particle board was higher than that of sawdust board.

  • PDF

An Experimental Study of Percutaneously Adjustable Pulmonary Artery Banding Device (가변성 폐동맥 혈류조절기의 실험적 연구)

  • Gang, Gyeong-Hun;Kim, Sang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.580-584
    • /
    • 1997
  • To overcome the problems of classical pulmonary banding procedure, we developed a percutaneously adjustable pulmonary artery ba ding device. The banding device consists of banding portion of zig-zag shaped self-expandable stainless steel wire, shaft portion made by a polyvinyl catheter and a screw adjuster which includes a bolt and a nut. As the screw moves, the diameter of banding portion changes. Four Mongrel dogs ranging from 15 kg to 20 kg in weight underwent the banding of the mid portion of descending aorta with this devices through the left thoracotomy. One month after operation, we evaluated the pressure changes by controling the banding with the devices and then the dogs were sacrificed to study the microscopic changes in the aorta. The diameter and circumference of the band could be easily and finely adjustable by the screw control. The pressure recordings . revealed a linear increase and decrease in pressure gradient according to percutaneous ad;ustment of the banding device. Since the banding device can be easily placed and simply adjusted percutaneously, we hope the banding device may be applicab e clinically to improving the safety of pulmonary artery banding and debanding procedures in the future.

  • PDF

MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE (교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가)

  • Kweon, Young-Sun;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.250-259
    • /
    • 2011
  • The aim of this study was to suggest a design for an orthodontic miniscrew which may work most favorably in the thin cortical bone of the adolescent. In this study, orthodontic miniscrews with different diameters, lengths, and body types were manufactured and implanted in two artificial bone samples with different cortical bone thickness. Maximum insertion torque, maximum removal torque, and lateral alteration torque were measured. As a result, the bone quality, body type, diameter, and the length all had their effects on the maximum insertion torque, maximum removal torque, and lateral alteration torque. Cortical bone thickness was the most important factor. In initial stability, conical types showed better results than cylindrical types. Increase in the diameter had favorable effects in achieving mechanical stability. Increase in the length did not have as much influence as the other factors did on the initial stability, but there was a statistically significant difference between screws of 6 mm and 8 mm lengths(p<0.05). In conclusion, the conical type screw with a diameter of 1.8 mm is most favorable in the thin cortical bone of the adolescent. In terms of length, the 8 mm screw is expected to perform better than the 6 mm screw.

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.3
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

Strength Properties of Wooden Model Erosion Control Dams Using Domestic Pinus rigida Miller I (국내산 리기다소나무를 이용한 목재 모형 사방댐의 강도 성능 평가 I)

  • Kim, Sang-Woo;Park, Jun-Chul;Lee, Dong-Heub;Son, Dong-Won;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.77-87
    • /
    • 2008
  • Wooden model erosion control dam was made with pitch pine, of which the strength properties was evaluated. Wooden model erosion control dam was made with diameter 90 mm of pitch pine round posts treated with CUAZ-2 (Copper Azole), changing joint in three different types. In each type, erosion control dam was made in nine floor (cross-bar of five floors and vertical-bar of four floors), of which the hight was 790 mm. And then strength properties were investigated through horizontal loading test and impact strength test, and the deformation of structure through image processing (AICON 3D DPA-PRO system). In horizontal loading test of wooden model erosion control dam using round post of diameter 90 mm, whether there was stone or not did not affect strength much when using self drill screw, but strength was decreased by 23%. In monolithic type of erosion control dam using screw bar, strength was increased by 1.5 times and deformation was decreased when filling with stone. When reinforcing with screw bar that ring is connected to self drill screw, strength was increased by 4.8 times. In impact strength test of wooden model erosion control dam made with round post of diameter 90 mm, the erosion control dam connected with self drilling screw not filling with stone was totally destroyed by the 1st impact, and the erosion control dam using screw bar was ruptured at cross-bar at which 779 kgf of impact was loaded in the 1st impact. In the 2nd impact, the base parts were ruptured, and reaction force was decreased to 545 kgf. In the 3rd impact, whole base parts were destroyed, and reaction force was decreased to 263 kgf.

SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT (콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례)

  • Kim, Rae-Gyoung;Song, Eon-Hee;Choi, Byeong-Gap;Kim, Hyoun-Chull;Ahn, Hyun-Jeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF

Stability of implant screw joint (임플란트 나사의 안정성)

  • Chung, Chae-Heon;Kwak, Jong-Ha;Jang, Doo-IK
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Crystal growth and characteristics of lysozyme crystals

  • Kojima, Kenichi
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.3-3
    • /
    • 2002
  • Many studies on crystal growth mechanisms of the hen egg-white lysozyme protein crystals have mainly performed by optical microscopy and atomic force microscopy (AFM). As results, two types of growth mechanisms, which are a two-dimensional nucleation mechanism and a spiral growth mechanism, were identified. However, there was no direct evidence of grown-in screw dislocations at the spiral sites. We first observed the screw dislocations in tetragonal lysozyme crystals using synchrotron X-ray topography. In addition, to confirm the characteristics of dislocations, we have observed some elastic constants in lysozyme crystals in terms of the sound velocity measurement by pulse echo methods. Tetragonal hen egg-white lysozyme crystals were grown by the concentration gradient method. The crystals were grown in test tubes, with an inner diameter of 8 ㎜ and 80 ㎜ in length, held vertically. The test tubes were kept at 23C for 2 weeks. The maximum size of crystals were 3×3×4 ㎟. The high quality crystals were examined by Laue topography with a water filter using synchrotron radiation. Figure is a X-ray topograph. Several straight screw dislocations were observed. We also determined Burgers vector to be a [110] direction. The measurement of sound velocity was performed by the digital signal processing method. the crystals were placed in stainless steel vessel, which was filled with lysozyme solution used for crystal growth. We observed the longitudinal sound velocity along the [110] direction in the tetragonal is obtained to be 1817 ㎧. Therefore, Young modulus and shear modulus were evaluated to be 2.70 Gpa and 1.02 Gpa, respectively, if we assumed Poisson ratio is 0.33. These results will be discussed at the meeting.

  • PDF

A Novel Axial Foldable Mechanism for a Segmented Primary Mirror of Space Telescope

  • Thesiya, Dignesh;Srinivas, Arra;Shukla, Piyush
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.269-279
    • /
    • 2015
  • Future space missions will have larger telescopes in order to look deeper into space while improvising on spatial resolution. The primary mirrors for these telescopes will be so large that using a monolithic mirror will be nearly impossible because of the difficulties associated with its fabrication, transportation, and installation on a launch vehicle. The feasibility of launching these huge mirrors is limited because of their small launch fairing diameter. The aerodynamic shape of the fairing requires a small diameter, but the height of the launch vehicle, which is available for designers to utilize, is larger than the fairing diameter. This paper presents the development of an axial deployment mechanism based on the screw jack principle. The mechanism was designed and developed, and a prototype was constructed in order to demonstrate a lab model.