• 제목/요약/키워드: Screw diameter

검색결과 191건 처리시간 0.024초

골조직과 임플랜트 계면의 최소접촉분율에 관한 삼차원 유한요소분석적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS ON THE MINIMUM CONTACT FRACTION OF BONE-IMPLANT INTERFACE)

  • 장경수;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.627-646
    • /
    • 1997
  • In order to find the degree of osseointegration at bone-implant interface of clinically successful implants, models including the 3.75mm wide, 10mm long screw type $Br{\aa}nemark$ implant as a standard and cylinder, 15mm long, 5.0mm wide, two splinted implants, and implants installed in various cancellous bone density were designed. Also, the amount of load and material of prostheses were changed. The stress and minimum contact fraction were analyzed on each model using three-dimensional finite element method(I-DEAS and ABAQUS version 5.5). The results of this study were as follows. 1. 10mm long, 3.75mm diameter-screw type implant had $36.5{\sim}43.7%$ of minimum contact fraction. 2. Cylinder type implant showed inferior stress distribution and higher minimum contact fraction than screw type. 3. As implant length was increased, minimum contact fraction was increased a little, however, maximum principal stress was decreased. 4. Implants with a large diameter had lower stress value with slightly higher minimum contact fraction than standard screw type. 5. Two splinted implants showed no change of minimum contact fraction. 6. The higher bone density, the lower stress value. 7. The material of occlusal surface had no effect on the stress of the bone-implant interface.

  • PDF

경골 원위부 골절에서 최소 침습적 잠김 압박 금속판 고정술과 함께 최소 절개를 통한 골절편간 지연 나사 고정술을 시행한 경우의 치료 결과 (Clinical Outcomes of Combinations of Locking Compression Plate Fixation through Minimally Invasive Precutaneous Plate Osteosynthesis and Interfragmentary Screw Fixation in Distal Tibia Fracture)

  • 정형진;추지웅
    • 대한족부족관절학회지
    • /
    • 제17권2호
    • /
    • pp.136-142
    • /
    • 2013
  • Purpose: To analyze the outcome of distal tibia fracture treated with the Distal Tibia LCP with combination of interfragmentary screw. Materials and Methods: Between January 2008 and March 2012, data of 34 patients with fracture of distal tibia treated with the Distal Tibia LCP with or without combination of interfragmentary screws were reviewed. There were 17 males and 17 females with an average age of 51.8 years (range, 18~77 years). Radiographic union time and time from surgery until ability to full weight bearing were measured and compared. Callus index was measured as quotient of callus thickness and diameter of corticalis both in AP and sagittal direction. Results: 12 fractures were treated with interfragmentary screws and 22 fractures were treated with bridging plate alone. In interfragmentary fixation group, time to full weight bearing was 14 weeks versus 15.75 weeks without screw. Callus index at bearing was not significantly lesser in patients with screw compated with those without, but callus index difference at posterative 4weeks was sigficant. Radiologic union time was 11.3 weeks in interfragmentary fixation group and 12.58 weeks without screw. Conclusion: The osteosynthesis with the Distal tibia LCP with combination of interfragmentary screw seems to be more stable in postoperative 4weeks than Distal tibia LCP alone, expecting to earlier ROM exercise and rehabilitation.

Optimization of Screw Pumping System (SPS) for Mass Production of Entrapped Bifidus

  • Ryu, Ji-Sung;Lee, Yoon-Jong;Choi, Soo-Im;Lee, Jae-Won;Heo, Tae-Ryeon
    • Food Science and Biotechnology
    • /
    • 제14권5호
    • /
    • pp.566-571
    • /
    • 2005
  • Process of screw-pumping system (SPS) was optimized for mass production of encapsulated bifidus. SPS entrapment device was composed of feeding component, with optimized nozzle size and length of 18G (0.91 cm) and 4 mm, respectively, screw pump, and 37-multi-nozzle. Screw component had five wing turns [radius (r)=26 to 15 mm] from top to bottom of axis at 78-degree angle from middle of the screw, and two wings were positioned at screw edge to push materials toward nozzle. For nozzle component, 37 nozzles were attached to 20-mm round plate. Air compressor was attached to SPS to increase productivity of encapsulated bifidus. This system could be operated with highly viscous (more than 300 cp) materials, and productivity was higher than $1128\;{\pm}\;30\;beads/min$. Viability of encapsulated bifidus was $5.45\;{\times}\;10^8\;cfu$/bead, which is superior to that of encapsulated bifidus produced by other methods ($2.51{\times}10^8\;cfu$/bead). Average diameter of produced beads was $2.048\;{\pm}\;0.003\;mm$. Survival rate of SPS-produced encapsulated bifidus was 90% for Simulator of the Human Intestinal Microbial Ecosystem test and 88% in fermented milk (for 14 days). These results show SPS is effective for use in development of economical system for mass production of viable encapsulated bifidus.

치과용 임플랜트에서 지대주 나사의 길이 및 반복 조임 횟수가 지대주 나사의 풀림에 미치는 영향 (THE INFLUENCE OF ABUTMENT SCREW LENGTH AND REPEATED TIGHTENING ON SCREW LOOSENING IN DENIAL IMPLANT)

  • 최진호;양재호;조원표;이재봉
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.432-442
    • /
    • 2006
  • Statement of problem: One of common problems associated with dental implant is the loosening of abutment screws that retain the implants. Purpose : This study was performed to investigate the influence of abutment screw length and repeated tightening on screw loosening in dental implant. Material and method: Forty nine Hexplants (13mm length, 4.3mm diameter, Ti grade IV, Warantec. Co. Ltd. Seongnam, Korea) and cementation type abutments(straight abutment) and abutment screws (0.4mm/pitch) were divided into 7 groups, depending on abutment screw length. Each implant and abutment was tightened to 30Ncm by torque controller(MGT50, MARK-10 Inc., USA) and the removal torque values were measured during 10 consecutive closure/opening trials. Results and Conclusion: The results of comparing the removal torque value are as follows : 1. There is no significant difference in the removal torque value between groups in 10 consecutive closure/opening trials (p = 0.97). 2. If the fractured abutment screw is engaged in longer than 2.425 thread length, there is no significant difference in the preload between the fractured abutment screw and the new abutment screw when both are equally tightened to 30 Ncm. 3. The removal torque value in the 1st trial(24.510 Ncm) was lower than that in the 2nd, 3rd, 4th, 5th, 6th, 7th trials and the removal torque value in the 2nd trials(25.551 Ncm) was maximum and was decreased in 1311owing trials. The removal torque value in the 1st trial was significantly lower than that in the 2nd, 3rd, 4th trials and was significantly higher than that in the 8th, 9th, l0th trials(p<0.05). 4. In the 2nd, 3rd, 4th, 5th, 6th, 7th trials, the abutment screw was mainly influenced by settling effect and the higher preload was obtained In the 8th, 9th, l0th trials, the abutment screw was mainly influenced by adhesive wear and the progressively lower preload was obtained.

The influence of screw type and osseointegration ratio on stress distribution in two different endosseous implants

  • Han, Jung-Suk
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.348-357
    • /
    • 2000
  • The purpose of this study is to examine the effect of partial osseointegration situation on bone loading patterns around two different free-standing screw shaped implants (Nobel Biocare, Gothenburg, Sweden and Degussa-Huls, Hanau, German). Two dimensional axisymmetric Finite element models of two implants(10mm length and 4mm diameter) were created according to different bone quantity, quality and osseointegration ratio in maxilla and mandible bone. At the same time uni-cortical and hi-cortical fixation were analyzed. Generally, full bond case showed less stress than partial bond case in overall area and mandibular model showed less amount of stress than that of maxilla model. Maximum stress of the Branemark implant is higher than that of ANKYLOS regardless of bonding ratio at crestal and apex region. However, more stress concentration was noted in ANKYLOS implant at screw body area especially in mandible. The effect of bicortical fixation on crestal bone stress reduction is dramatical in mandible however, there was no significant effect in maxillary case. The effect of partial bond on stress distribution was more significant at screw body and apex region than in crestal region. Partial bond cases demonstrated greater stress accumulation in trabecular bone than cortical bone. It is concluded that the more accurate model of implant and bone which affects stress and strain distribution is needed to mimic in vivo behavior of implants.

  • PDF

2축선의 프로펠러 레이싱 추정법에 관한 연구 (Propeller Racing of Ocean-going Ships with Twin Screw Propellers)

  • 박종헌
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.98-106
    • /
    • 2007
  • This paper presents a statistical prediction procedure for the propeller racing of ships with twin screw propellers sailing in ocean waves. The propeller racing is one of the most important factors of seakeeping qualities in relation to the safety of main engine and shafting system. It is especially significant key word for designing the twin-screw-propeller-type ship in view of allowable maximum propeller diameter etc.. In former studies, the propeller racing generally means the situation (propeller exposed) in which the relative motion amplitude between ship hull and wave surface would exceed a depth of point in rotary disk propeller. Therefore, it seems that the magnitude of the amplitude and its exceeding frequency have been examined as a principal subject of study as usual. However, the time during which the amplitude exceeds a depth of point must be also one of most important factor affecting the trend of propeller racing. This paper proposes a simply practical method for estimating the time lasting of exposed propeller related to twin screw propeller racing in rough confused seas on the basis of the statistics. Then, it is confirmed that the practical method is useful and convenience for considering the propeller racing in the stage of the basic design.

  • PDF

Determination of slip modulus of cold-formed steel composite members sheathed with plywood structural panels

  • Karki, Dheeraj;Far, Harry;Al-hunity, Suleiman
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.511-522
    • /
    • 2022
  • An experimental investigation to study the behaviour of connections between cold-formed steel (CFS) joist and plywood structural panel is presented in this paper. Material testing on CFS and plywood was carried out to assess their mechanical properties and behaviour. Push-out tests were conducted to determine the slip modulus and failure modes of three different shear connection types. The employed shear connectors in the study were; size 14 (6mm diameter) self-drilling screw, M12 coach screw, and M12 nut and bolt. The effective bending stiffness of composite cold-formed steel and plywood T-beam assembly is calculated based on the slip modulus values computed from push-out tests. The effective bending stiffness was increased by 25.5%, 18% and 30.2% for self-drilling screw, coach screw, nut and bolt, respectively, over the stiffness of cold-formed steel joist alone. This finding suggests the potential to enhance the structural performance of composite cold-formed steel and timber flooring system by mobilisation of composite action present between timber sheathing and CFS joist.

레이저 광학 장비와 컴퓨터를 이용한 자동측정 장치의 개발 (Development of an Automated Shaft Outside Diameter Measuring System)

  • 최상민;이정주
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.197-199
    • /
    • 1986
  • To meet tight tolerance requirements of mass produced shafts which are subcomponents of automobile parts, an automated measuring system has been developed. The system comprises of a non-contact shaft diameter measuring instrument using laser, a feed mechanism of a step motor and ball screw and a personal computer. The system can determine pass-fail of the piece under test and also analyze data for statistical process control.

  • PDF

무인이송로봇기반 자동 소사료 공급 시스템 개발 및 검증 (Development and Verification of the Automated Cow-Feeding System Driven by AGV)

  • 안성수;이용찬;유지훈;이연정
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.232-241
    • /
    • 2017
  • 본 논문에서는 대형화되고 기업화되어가고 있는 국내 축산농가를 위한 AGV와 스크류컨베이어 기반의 자동 소사료 공급시스템에 대해 소개한다. 제안된 자동 소사료 공급시스템은 최상단에 펠렛형 혼합 사료가 적재되는 호퍼부, 호퍼부에서 펠렛형 혼합사료를 배출부로 이송시키는 스크류컨베이어를 장착한 이송부, 벨트컨베이어로 구성된 배출부 및 시스템 이동을 위한 전자 유도선 주행방식의 AGV로 구성되어있다. 적재된 사료 무게는 이송부의 하부에 위치한 로드셀에 의해 측정된다. 개별 우사 셀에 설치되는 RFID TAG에 미리 저장된 사료 배출정보를 시스템이 읽어 정해진 양만큼의 사료를 시스템이 주행하면서 배출하게된다. 공급 배출 테스트시스템을 제작하여 사료의 공급 능력을 결정짓는 사료 이송부의 스크류 외경, 스크류 샤프트 외경, 스크류 피치 간격 등을 포함하는 스크류컨베이어 설계인자 도출을 하였으며 도출된 설계인자들을 최종 공급시스템 제작 시에 적용하였다. 사료 급이시스템을 제어하기 위해 DSP기반의 주제어기 및 공급시나리오에 따른 급이알고리듬도 함께 개발되었다. 실험을 통해 국내 우사에 사료공급조건을 만족시키기 위해 설정된 목표인 5 m의 거리를 0.1 m/sec의 속도로 주행하면서 7 마리가 수용되는 한 개의 우사에 필요한 총 21 kg의 사료를 초당 420 g으로 균일하게 공급이 가능함을 확인하여 개발된 축우용 무인사료공급시스템이 규격화된 국내 축산농가에 적용될 수 있는 가능성을 확인하였다.

토양굴취력이 향상된 스크류형 경량 식혈기 개발(I) - 설계 및 제작 - (Development of Screw-Type Handy Earth Auger for an Improved Digging Efficiency(I) - Design and Manufacture -)

  • 김진현;이재현;김기동;고치웅;김동근
    • 농업생명과학연구
    • /
    • 제50권3호
    • /
    • pp.31-41
    • /
    • 2016
  • 본 연구는 산림조성사업에 있어서 가장 큰 비중을 차지하는 인건비와 생산비용을 절감시키고 경사가 험준한 우리나라 산림지형에서 유용하게 이용 가능한 경량 식혈기를 개발하고자 수행하였다. 제작된 1차 시제품은 토양을 굴취하는 스크류(screw) 부분과 동력원인 배터리로 구성되고, 제원은 스크류의 길이 170mm, 상단폭 60mm, 하단폭 47mm, 나선각(Helix angle)은 23°, 그리고 Tip은 송곳형태로 길이 50mm로 설계·제작하였고 무게를 줄이기 위해 1줄 스크류를 채택하였다. 또한, 동력원으로는 회전용 DC Motor(WD-6G2425, WONILL, Korea)로 최대 Torque는 30㎏f-cm, 회전속도는 20~30rpm으로 설정하였다. 감속비는 30:1의 K6G30C 감속기에 무부하 상태로 사용한 결과 48시간 작동하였다. 그리고 배터리는 경량식재기의 개발을 목표로 하기 때문에 무게를 고려하여 리듐배터리를 사용하였으며, 포트묘의 길이가 15cm 내외인 점을 고려하면 스크류의 회전력이 최대 100kgf-cm정도로 설계하였다. 1차 시제품의 성능을 평가하기 위해 조사지에서 굴취시 스크류에 소요되는 회전력을 측정한 결과, 회전력이 가장 큰 곳은 A area(단단한 초지), 그 다음은 F area(경사가 40°인 산지), E area(경사가 30°인 산지)의 순서로 나타났다. 토양의 굴취 회전력은 일반적으로 깊이가 깊어질수록 높아지는 경향을 보이고 있으며, 대체적으로 토양의 깊이 10cm 부근에서 높은 경향을 보였다.