• Title/Summary/Keyword: Screw diameter

Search Result 191, Processing Time 0.035 seconds

Effects of Wood Particles and Steel Wire Compositions on Physical and Mechanical Properties of the Boards (목재(木材)파아티클과 철선(鐵線) 복합체(複合體)가 보오드의 물리적(物理的) 및 기계적(機械的) 성질(性質)에 미치는 영향(影響))

  • Park, Heon;Lee, Pill-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.3-44
    • /
    • 1986
  • In order to obtain the basic physical and mechanical properties of steel wire reinforced particleboard, particleboards were formed with large particles through 2.11 mm (12 meshes) and retained on 1.27mm (20 meshes) sieves and small particles through 1.27mm (20 meshes) and retained on 0.42mm (60 meshes) sieves from the plywood mill wastes of meranti (Shorea spp.) in the form of pallmanchips, applying urea-formaldehyde resin as an adhesive on the particle surface in 10 percent on the oven dried weight of particles, and arranging steel wires of 1mm in diameter 5,10,15,20, and 25mm in longitudinal and transverse direction with crossing in the mid of the board depth in single layer boards, 10mm in longitudinal or transverse direction without crossing in two layers and 10mm in longitudinal and transverse directions with and without crossing in three steel wire layers boards. The stepwise 9-minutes-multi-pressing schedule in 5 minutes at 35 kgf/$cm^2$, 2.5 minutes at 25 kgf/$cm^2$. and 1.5 minutes at 15 kgf/$cm^2$ was applied for $300{\times}200{\times}13$mm board at the temperature of 160$^{\circ}C$ in a hot press. Specific gravity, thickness swelling, bending properties of modulus of rupture (MOR), modulus of elasticity(MOE), work to proportional limit, and work to ultimate load, internal bond (IB), and screw holding power(SHP) of the reinforced boards were analyzed on the wire openings and wire layers. The results obtained are summarized as follows; 1) In specific gravity, particleboards with large particles and small particles had higher value with more steel wire placements and more steel layers composition, 2) Particleboards with large particles in accordance with more steel wire liners composition gave very poor thickness swelling. 3) The mechanical properties of particleboards formed with large or small particles were reinforced with more steel wire layers. Therefore, bending strength was improved in modulus of rupture, modulus of elasticity, and work to ultimate load. Especiallv, particleboards with two or three steel wire layers showed the tension lamination effect when the steels in lower steel wire layer were oriented parallel to the board length. 4) The modulus of rupture, modulus of elasticity, and work to ultimate load in bending varied with opening area, distance of lengthwise wires multipled by distance of transverse wires. Particleboards formed with large particles resulted in higher value in modulus of rupture with 1.5-3 $cm^2$ opening area, 1-2cm distance between transverse wires, and 1.5-2.5cm distance between lengthwise wires. Particle boards formed with small particles showed higher value with 0.5-1.5$cm^2$ or 3.75-6.25 $cm^2$ opening area, 0.5 or 2.5cm distance between transverse wires. 5) In modulus of elasticity, particleboards formed with large particles with one steel wire layer suggested higher value with 5-3$cm^2$ opening area, 1-2.5cm distance between transverse wires and also 1-2.5 cm distance between lengthwise wires. Particleboards formed with small particles showed higher value with 0.75-1.25$cm^2$ or 3-6.25$cm^2$ opening area and 0.5 or 2.5cm distance between transverse wires. 6) Particleboards formed with large particles gaved higher value in work to ultimate load with 1-3$cm^2$ opening area. Particleboards formed with small particles showed increasing tendancy with decreasing opening area. 7) In internal bond and screw holding power, particleboards formed with large particles had increasing value in two and three steel wire layers compositions, but particleboards formed with small particles showed no difference. Particleboards formed with large particles containing one steel wire layer showed no difference in internal bond and screw holding power, and particleboards formed with small panicles containing one steel wire layer resulted in increasing value in internal bond and decreasing value in screw holding power in accordance with increase in opening area.

  • PDF

Factors influencing primary stability of miniplate anchorage: a three-dimensional finite element analysis (미니플레이트의 골내 고정원 적용 시 초기 안정성에 영향을 주는 요인에 대한 3차원 유한요소법적 연구)

  • Lee, Nam-Ki;Choi, Dong-Soon;Jang, In-San;Cha, Bong-Kuen
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.304-313
    • /
    • 2008
  • Objective: The purpose of this study was to evaluate the stress distribution in bone and displacement distribution of the miniscrew according to the length and number of the miniscrews used for the fixation of miniplate, and the direction of orthodontic force. Methods: Four types of finite element models were designed to show various lengths (6 mm, 4 mm) and number (3, 2) of 2 mm diameter miniscrew used for the fixation of six holes for a curvilinear miniplate. A traction force of 4 N was applied at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$ and $90^{\circ}$ to an imaginary axis connecting the two most distal unfixed holes of the miniplate. Results: The smaller the number of the miniscrew and the shorter the length of the miniscrew, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. Most von Mises stress in the bone was absorbed in the cortical portion rather than in the cancellous portion. The more the angle of the applied force to the imaginary axis increased, the more the maximum von Mises stress in the bone and maximum displacement of the miniscrew increased. The maximum von Mises stress in the bone and maximum displacement of the miniscrew were measured around the most distal screw-fixed area. Condusions: The results suggest that the miniplate system should be positioned in the rigid cortical bone with 3 miniscrews of 2 mm diameter and 6 mm length, and its imaginary axis placed as parallel as possible to the direction of orthodontic force to obtain good primary stability.

Physicochemical Quality Characteristics of Traditional Kamju Using Extruded Rice Collet Powder (압출 쌀 콜렛 분말을 사용한 전통 감주의 제조 및 이화학적 품질 특성)

  • Je, Hae-Soo;Kang, Kyung-Hun;Park, Si-Young;Choi, Byeong-Dae;Kang, Young-Mi;Kim, Jeong-Gyun
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.147-152
    • /
    • 2016
  • This study was conducted to investigate the physicochemical quality properties and provide basic data for the activation of traditional Kamju of juice type product prepared by mixing malt and extruded rice collet powder. Malt extracts were prepared by extracting the mixture of malt and water at a weight ratio of 25:75 after soaking for 2 h at $45^{\circ}C$. Rice collet powder was prepared by adjusting the barrel temperature to $95^{\circ}C$, screw speed to $3.07{\times}g$, discharge port diameter to 7 mm and a raw material input to 50 kg/h, the powder was then ground to a particle size of 80 mesh. The physicochemical characteristics (pH, color, viscosity, reducing sugars, number of viable cells, free amino acids) and sensory evaluations were conducted at various time points during the saccharification and at different mixing ratios of the extruded rice collet powder to malt extract (5:95, 15:85, 25:75, 35:65, each at $55^{\circ}C$ for 9 h). As a result, with an increase in the proportion of the extruded rice collet powder and saccharification time, the physicochemical properties of traditional Kamju significantly improved (p<0.05). A mixing ratio of 35:65 rice collet powder to malt extract and a saccharification time of 9 h were found to be the most desirable conditions. However, based on the sensory evaluation, a mixing ratio of rice collet powder and malt extract of 25:75 and a saccharification time of 5 h resulted in the most preferable palatability of traditional Kamju (p<0.05). Therefore, the mixing ratio and saccharification time should be determined to provide a better choice with respect to the taste and economic aspects of traditional Kamju.

A 15-year clinical retrospective study of Br${\aa}$nemark implants (Br${\aa}$nemark 임플란트의 15년 임상적 후향 연구)

  • Park, Hyo-Jin;Cho, Young-Ye;Kim, Jong-Eun;Choi, Yong-Geun;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: This study was to compare the cumulative survival rate (CSR) of Br${\aa}$nemark machined surface implants and TiUnite$^{TM}$ imlants and to analyze association between risk factors and the CSR of the implants. Materials and methods: A retrospective study design was used to collect long-term follow-up clinical data from dental records of 156 patients treated with 541 Br${\aa}$nemark machined and TiUnite$^{TM}$ implants at Korea University Guro hospital in South Korea from 1993 through 2008. Machined implant and TiUnite$^{TM}$ implant were compared by CSR. Exposure variables such as gender, systemic disease, location, implant length, diameter, prosthesis type, opposing occlusion type, date of implant placement, type of edentulous space, abutment type, existence of splinting with natural teeth, and existence of cantilever were collected. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR (${\alpha}$=.05). Results: Patient ages ranged from 16 to 75 years old (mean age, 51 years old). Implants were more frequently placed in men than women (94 men versus 63 women). Since 1993, 264 Br${\aa}$nemark machined implants were inserted in 79 patients and since 2001, 277 TiUnite$^{TM}$ implants were inserted in 77 patients. A total survival rate of 86.07% was observed in Br${\aa}$nemark and Nobel Biocare TiUnite$^{TM}$ during 15 years. A survival rate of machined implant during 15 years was 82.89% and that of TiUnite$^{TM}$ implant during 5 years was 98.74%. The implant CSR revealed lower rates association with several risk factors such as, systemic disease, other accompanied surgery, implant location, and Kennedy classification. Conclusion: Clinical performance of Br${\aa}$nemark machined and TiUnite$^{TM}$ implant demonstrated a high level of predictability. In this study, TiUnite$^{TM}$ implant was more successful than machined implant. The implant CSR was associated with several risk factors.

Study of the re-osseointegration of implant fixture after mechanical unscrewing (임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구)

  • Jang, Ji-Hoon;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants (Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구)

  • Kang, Hyun-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The objective of this study was to investigate the effects of calcium phosphate coated titanium implant surface on bone response and implant stability at early stage of healing period of 3 weeks and later healing period of 6 weeks. Material and methods: A total of 24 machined, screw-shaped implants (Dentium Co., Ltd., Seoul, Korea) which dimensions were 3.3 mm in diameter and 5.0 mm in length, were used in this research. All implants (n = 24), made of commercially pure (grade IV) titanium, were divided into 2 groups. Twelve implants (n = 12) were machined without any surface modification (control). The test implants (n = 12) were anodized and coated with thin film (150nm) of calcium phosphate by electron-beam deposition. The implants were placed on the proximal surface of the rabbit tibiae. The bone to implant contact (BIC) ratios was evaluated after 3 and 6 weeks of implant insertion. Results: The BIC percentage of calcium phosphate coated implants ($70.8{\pm}18.9%$) was significantly higher than that of machined implants ($44.1{\pm}16.5%$) 3 weeks after implant insertion (P = 0.0264). However, there was no significant difference between the groups after 6 weeks of healing (P > .05). Conclusion: The histomorphometric evaluation of implant surface revealed that; 1. After 3 weeks early healing period, bone to implant contact (BIC) percentage of calcium phosphate coated implants (70.8%) was much greater than that of surface untreated machined implants (44.1%) with P = 0.0264. 2. After 6 weeks healing period, however, BIC percentage of calcium phosphate coated implants group (79.0%) was similar to the machined only implant group (78.6%). There was no statistical difference between two groups (P = 0.8074). 3. We found the significant deference between the control group and experimental group during the early healing period of 3 weeks. But no statistical difference was found between two groups during the later of 6 weeks.

HISTOLOGICAL CHANGES IN THE ELONGATED BONE AFFECTED BY OSTEODISTRACTION OF THE MANDIBLE IN THE DOG (성견 하악골 절단 후 기계적 골 견인에 의해 형성된 골 신장부에 대한 시기별 조직학적 변화)

  • Baek, Sun-Ho;Ahn, Byoung-Keun;Park, Young-Ju;Park, Hee-Geon;Park, Jun-Woo;Rhee, Gun-Joo;Lee, Yong-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.404-416
    • /
    • 2001
  • Purpose : Traditionally, the treatement of choice has been a bone grafting procedure to increase the length of bone in case of actual length discrepancy. But, bone grafting procedure has many disadvantages, for example, graft resorption, donor site morbidity, and so on. So, many trials have been performed to avert the use of autogenous bone graft via introducing new materials or methods. And, one of those trials has been realized by the development of a technique inducing bone lengthening by osteotomy (or corticotomy) and slow gradual distraction of the osteotomized segments. This new technique of bone lengthening dates back to the early 20th century. But, the majority of information concerning the biology of new bone formation during bone lengthening and technical details of the procedure were produced by extensive clinical and experimental studies performed by Ilizarov, a Russian surgeon. According to Ilizarov, with adequate blood supply, preservation of periosteum, rigid fixation of the osteotomized segments, and proper rate and rhythm of distraction, intramembranous bone rapidly develops within the distraction gap in the limb lengthening procedure. In the limb lengthening, many orthopedic surgeons try to observe the biologic and clinical principles recommended by Ilizarov. In the oral and maxillofacial region, however, not a few studies must be performed to apply this surgical technique in the clinical cases. Besides, the mechanism of bone formation in the distraction gap is not clear, yet. The purpose of this experiment was to scrutinize serially the histological changes in the elongated bone affected by osteodistraction of the mandibular body in an adult canine model. In addition, it was performed to confirm the presence of specific region(s) which was important in the bone formation in the gap through the observation of the expression pattern of osteocalcin and osteonectin with the immunohistochemical examination. Materials and Methods : The experimental and control specimens were obtained from seven adult male mongrel dogs weighing over 20kg. The distractors were custom-made linear extraoral devices and bicortical fixation screws were 2.3mm in diameter, 50mm in total length, 15mm in screw length. The distractors were devised to produce a linear gap of 0.75mm between two bony segments every $360^{\circ}$ turn of the rotation rod of the device. The mandibular body of the right side of each animal was corticotomized perpendicular to the occlusal plane and then two bony segments were separated completely by careful manipulation of the segments with bone forceps. The left side of each animal was left intact. This side was served as control. At sixth day after osteotomy and fixation of the segments were performed, distraction of the segments was commenced with a rate of 1.1mm/day and a rhythm of two/day for ensuing 7 days. The animals were euthanized at the 16th. 29th, and 44th day after the osteotomy. The bony specimens were decalcified, embedded in paraffin, sectioned $5{\mu}m$ thick and stained with H&E. The prepared specimens were examined under the light microscope. And, immunohistochemical examinations using anti-osteocalcin antibody (OC1, Biodesign, USA) and anti-osteonectin antibody (Haematologic Technologies Inc., Essex, VT) to locate the expressions of osteocalcin and osteonectin, respectively, were performed. Results : 1. New bone was observed already at the 16th. day after osteotomy. This suggests that new bone formation in osteodistraction was commenced at an early stage of the regenerative process. But, radiologically and microscopically, bony union was not completed in the distraction gap at the 44th. day after osteotomy. Therefore, rigid fixation must be maintained between the bony fragments till the complete bony union is confirmed clinically rather than one month or so after the completion of distraction.

  • PDF

Effect on bone healing by the application of low intensity pulsed ultrasound after injection of adipose tissue-derived stem cells at the implantation of titanium implant in the tibia of diabetes-induced rat (당뇨유도 백서 경골에 티타늄 임플란트 매식 시 지방조직 유래 줄기세포 주입 후 저출력 초음파 적용이 골치유에 미치는 영향)

  • Jung, Tae-Young;Park, Sang-Jun;Hwang, Dae-Suk;Kim, Yong-Deok;Lee, Soo-Woon;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.301-311
    • /
    • 2011
  • Introduction: This study examined the effect of the application of low intensity pulsed ultrasound on bone healing after an injection of adipose tissue-derived stem cells (ADSCs) during the implantation of a titanium implant in the tibia of diabetes-induced rats. Materials and Methods: Twelve Sprague-Dawely rats were used. After inducing diabetes, the ADSCs were injected into the hole for the implant. Customized screw type implants, 2.0 mm in diameter and 3.5 mm in length, were implanted in both the tibia of the diabetes-induced rats. After implantation, LIPUS was applied with parameters of 3 MHz, 40 mW/$cm^2$, and 10 minutes for 7 days to the left tibiae (experimental group) of the diabetesinduced rats. The right tibiae in each rat were used in the control group. At 1, 2 and 4 week rats were sacrificed, and the bone tissues of both tibia were harvested. The bone tissues of the three rats in each week were used for bone-to-implant contact (BIC) and bone area (BA) analyses and the bone tissues of one rat were used to make sagittal serial sections. Results: In histomorphometric analyses, the BIC in the experimental and control group were respectively, $39.00{\pm}18.17%$ and $42.87{\pm}9.27%$ at 1 week, $43.74{\pm}6.83%$ and $32.27{\pm}6.00%$ at 2 weeks, and $32.62{\pm}11.02%$ and $47.10{\pm}9.77%$ at 4 weeks. The BA in experimental and control group were respectively, $37.28{\pm}3.68%$ and $31.90{\pm}2.84%$ at 1 week, $20.62{\pm}2.47%$ and $15.64{\pm}2.69%$ at 2 weeks, and $11.37{\pm}4.54%$ and $17.69{\pm}8.77%$ at 4 weeks. In immunohistochemistry analyses, Osteoprotegerin expression was strong at 1 and 2 weeks in the experimental group than the control group. Receptor activator of nuclear factor kB ligand expression showed similar staining at each week in the experimental and control group. Conclusion: These results suggest that the application of low intensity pulsed ultrasound after an injection of adipose tissue-derived stem cells during the implantation of titanium implants in the tibia of diabetes-induced rats provided some positive effect on bone regeneration at the early stage after implantation. On the other hand, this method is unable to increase the level of osseointegration and bone regeneration of the implant in an uncontrolled diabetic patient.

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.