• 제목/요약/키워드: Screw diameter

검색결과 191건 처리시간 0.027초

SQUID와 검출코일의 초전도 결합방식이 개선된 1차 권선형 미분계 시스템 (First-order Wire-wound SQUID Gradiometer System Having Compact Superconductive Connection Structure between SQUID and Pickup Coil)

  • 이용호;유권규;김진목;권혁찬;김기웅;박용기
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.23-28
    • /
    • 2007
  • In order to have a superconductive connection between the wire-wound pickup coil and input coil, typically Nb terminal blocks with screw holes are used. Since this connection structure occupies large volume, large stray pickup area can be generated which can pickup external noise fields. Thus, SQUID and connection block are shielded inside a superconducting tube, and this SQUID module is located at some distance from the distal coil of the gradiometer to minimize the distortion or imbalance of uniform background field due to the superconducting module. To operate this conventional SQUID module, we need a higher liquid He level, resulting in shorter refill interval. To make the fabrication of gradiometers simpler and refill interval longer, we developed a novel method of connecting the pickup coil into the input coil. Gradiometer coil wound of 0.125-mm diameter NbTi wires were glued close to the input coil pads of SQUID. The superconductive connection was made using an ultrasonic bonding of annealed 0.025-mm diameter Nb wires, bonded directly on the surface of NbTi wires where insulation layer was stripped out. The reliability of the superconductive bonding was good enough to sustain several thermal cycling. The stray pickup area due to this connection structure is about $0.1\;mm^2$, much smaller than the typical stray pickup area using the conventional screw block method. By using this compact connection structure, the position of the SQUID sensor is only about 20-30 mm from the distal coil of the gradiometer. Based on this compact module, we fabricated a magnetocardiography system having 61 first-order axial gradiometers, and measured MCG signals. The gradiometers have a coil diameter of 20 mm, and the baseline is 70 mm. The 61 axial gradiometer bobbins were distributed in a hexagonal lattice structure with a sensor interval of 26 mm, measuring $dB_z/dz$ component of magnetocardiography signals.

  • PDF

Single Extruder를 이용한 마른새우첨가 쌀 Collets 제조 시 독립변수의 조건변화에 따른 종속변수의 특성 (Characteristics of the Dependent Variable due to Changes in the Conditions of the Independent Variable During the Producing of Collets Added with Rice and Dried Shrimp by Single Extruder)

  • 제해수;윤문주;이재동;강경훈;박시영;박진효;김정균
    • 수산해양교육연구
    • /
    • 제27권5호
    • /
    • pp.1352-1363
    • /
    • 2015
  • 주원료인 쌀과 부원료인 마른새우의 농수산 복합물을 single screw extruder를 이용하고, 다목적 식품소재의 적용을 위하여 원료독립변수 3개(쌀의 함수율, 쌀의 입도, 마른새우 첨가율)와 작동독립변수 4개(barrel 온도, screw 속도, 토출구직경, 원료투입량)의 총 독립변수 7개의 조건변화에 의한 5개의 종속변수(팽화도, 함수율, 명도, 균질성, 생산성)의 특성은 다음과 같다. 쌀의 함수율을 12, 14, 16, 18%로 조건 변화하여 collets을 제조할 경우, collets의 팽화도는 그 값이 증가하다가 감소하였고, 함수율 및 명도는 증가하였고, 균질성은 감소하는 경향이었다. 쌀의 입도를 raw, 20, 40, 60 mesh로 조건 변화하여 collets을 제조할 경우, collets의 팽화도는 그 값이 미미하나마 감소하였으나 유의적인 큰 차이가 없었고, 함수율은 raw에 비해 20 mesh 입자의 크기로 작아질 때 함수율이 감소하였으나 20 mesh 이상으로 더 분쇄하여 입자의 크기가 작아지더라도 변화 없이 거의 일정하였으며, 명도는 쌀 입도의 크기에 따른 유의차가 없었고, 균질성은 증가하는 경향이었다. 마른새우의 첨가율을 2, 4, 6, 8%로 조건 변화하여 collets을 제조할 경우, collets의 함수율 및 명도는 증가하였고, 팽화도 및 균질성은 감소하는 경향이었다. Barrel 온도를 90, 95, 100, $110^{\circ}C$로 조건 변화하여 collets을 제조할 경우, collets의 팽화도 및 균질성은 유의적으로 증가하였고, 함수율 및 명도는 감소하는 경향이었다. Screw 속도를 210, 280, 340 rpm으로 조건 변화하여 collets을 제조할 경우, collets의 팽화도, 균질성 및 생산성은 증가하였고, 함수율 및 명도는 감소하였다. 토출구 직경을 4, 6, 8, 10 mm로 조건 변화하여 collets을 제조할 경우, collets의 팽화도 및 균질성은 감소하였고, 함수율 및 명도는 증가하였으며, 생산성은 그 값이 증가하다가 일정하였다. 원료투입량을 30, 40, 50, 60 kg/h로 조건 변화하여 collets을 제조할 경우, collets의 팽화도, 함수율, 명도 및 생산성은 증가하였고, 균질성은 감소하였다. 이와 같이 쌀을 주원료로 하고 부원료로 마른새우를 첨가하여 collets을 제조할 경우, 독립변수의 변화에 따라 종속변수의 값이 변화하여 최종제품인 collets의 품질에 영향을 미쳤다. 따라서 품질이 좋은 collets을 제조하기 위해서는 독립변수를 잘 설정할 필요가 있다고 판단되었다.

추진축설계(推進軸設計)에 관(關)한 각선급협회규칙(各船級協會規則)의 비교연구(比較硏究) (A Comparative Study of the Rules of Ship Classification Societies on the Propeller Shaft Design.)

  • 김극천;이재욱
    • 대한조선학회지
    • /
    • 제4권1호
    • /
    • pp.59-65
    • /
    • 1967
  • Since the screw propellers were adopted as ship propulsion devices, the replacement of propeller shaft due to damage was mostly of fatigue failure due to the alternative stresses [1],[2]. To prevent such a failure, hence, it is suggested that careful attention should be paid to account of the alternative stresses on the design stage of the propeller shafts. In connection with this fact the Ship Classification Societies' Rules are regarded simply as guidance for preliminary determination of the shaft diameter. In this paper, limiting the topic to the small and medium-sized motor ships, an evaluation of the Rules formulae to a theoretical based on Soderberg's correlation [5] between the factor of safety and the resultant stresses obtained by application of the maximum shear theory is done. For this purpose eleven (11) ships built recently in Korea were taken as a species(refer to table 2. in text). In the end the following conclusions are made: (1) In general the Rules formulae give considerably larger size of the propeller shaft diameter than that derived from theoretical calculation, that is, about 7% more in AB and BV Rules, and about 20% more in LR and KR-NK Rules. (2) LR Rule gives the largest size of all, and AB Rule is mostly closed value to the theoretical. (3) The formular of the AB Rule is considered to be of the simplest in utilization and of the reasonable.

  • PDF

선반 구조변경을 위한 현장용 공구대 강성계산모델 (Practical Turret Stiffness Calculation Model to Modify Lathe Structure)

  • 허성혁;김수진
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.19-24
    • /
    • 2017
  • In this research, a practical stiffness calculation method is developed and applied for modifying the height of the headstock, turret, and tailstock of a CNC lathe to enlarge the turntable diameter. The casting structure is assumed to be a rigid body and the linear motion element to be an elastic spring to simplify the turret stiffness calculation model. The stiffness of the sliding guide and ball screw of the original lathe is measured with a push tester and LVDT sensor, and the turret stiffness of the modified lathe is predicted and compared with experimental results to verify the model. The measured stiffness of the original turret is $0.17kN/{\mu}m$ and that of the modified turret is $0.11kN/{\mu}m$, i.e., an 18% difference from the predicted result. The verified stiffness calculation model can be used to develop another modified lathe.

Sandblasted large grit, acid etched 표면처리에 따른 교정용 미니 임플랜트의 제거회전력에 관한 연구 (Removal torque of sandblasted large grit, acid etched treated mini-implant)

  • 오남희;김성훈;국윤아;이근혜;강윤구;모성서
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.324-330
    • /
    • 2006
  • Sandblasted large grit, acid etched(SLA)표면처리 된 교정용 미니 임플랜트와 평활면을 가진 교정용 미니 임플랜트 사이에 제거회전력과 조직학적 소견을 통해 표면처리된 교정용 임플랜트의 임상적 가능성에 대하여 알아보고자 하였다. 실험재료로는 길이가 9.5 mm, 외경이 1.8 mm인 custom made, screw shaped, titanium implants가 사용되었다. 미니 임플랜트는 두개의 군으로 분류되었는데 SLA군은 20개의 SLA 표면처리된 미니 임플랜트이었고, 평활면군은 크기와 형태가 같지만 SLA처리공정이 생략되어 제작된 20개의 미니 임플랜트로 구성되었다. 이들은 10마리 가토의 경골에 식립되었다. 각각의 가토의 우측 경골에는 SLA군의 미니 임플랜트 2개가 식립되었고, 좌측 경골에는 평활면군의 미니 임플랜트 2개가 식립되었다. 각 군에는 식립 직후 Ni-Ti coil spring에 의해 약 150 g의 지속적인 견인력이 주어졌다. 식립 6주 후에 10마리의 가토를 희생하였고, 안정된 상태에서 Ni-Ti coil spring을 제거하였으며 digital torque gauge를 이용하여 제거 회전력을 측정하였다. 식립 6주 후에 SLA군의 경우 (8.29 Ncm) 평활면군 (3.34 Ncm)에 비해 더 높은 평균 제거회전력을 나타내었고 조직학적 소견에서도 screw 하방에서의 신생골 형성이 관찰되었다. SLA 표면처리된 미니 임플랜트는 평활면 미니 임플랜트에 비해 좀 더 강한 교정력에 저항할 수 있을 것으로 예상되었다.

임플란트 고정체의 platform의 크기에 따른 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO PLATFORM WIDTH OF FIXTURE)

  • 정경민;정재헌;정승미
    • 대한치과보철학회지
    • /
    • 제41권5호
    • /
    • pp.674-688
    • /
    • 2003
  • Statement of Problem : With increasing demand of the implant-supported prosthesis, it is advantageous to use the different platform width of the fixture according to bone quantity and quality of the patients. Purpose : The purpose of this study was to assess the loading distributing characteristics of two implant designs according to each platform width of fixture, under vertical and inclined loading using finite element analysis. Material and method : The two kinds of finite element models were designed according to each platform width of future (4.1mm restorative component x 11.5mm length, 5.0mm wide-diameter restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction, 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction and 200N at the buccal cusp in a 300 transverse direction individually Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. Results : The stresses were concentrated mainly at the cortex in both vertical and oblique load ing but the stresses in the cancellous bone were low in both vertical and oblique loading. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading. Increasing the platform width of the implant fixture decreased the stress in the supporting bone, future and abutment screw. Increased the platform width of fixture decreased the stress in the crown and platform. Conclusion : Conclusively, this investigation provides evidence that the platform width of the implant fixture directly affects periimplant stress. By increasing the platform width of the implant fixture, it showed tendency to decreased the supporting bone, future and screw. But, further clinical studies are necessary to determine the ideal protocol for the successful placement of wide platform implants.

Melt-blown 방사에 의한 PP/Ba-ferrite 복합 부직포 제조시의 공정인자가 부직포의 특성에 미치는 영향 (Effect of Processing Factors on the Properties of Melt-blown PP/Ba-ferrite Composite Fabrics)

  • 한종헌;이동진;임형미;이승호;오성근
    • 공업화학
    • /
    • 제17권3호
    • /
    • pp.267-273
    • /
    • 2006
  • Melt-blown 방사법으로 Ba-ferrite 포함하는 PP 복합수지를 방사하여 부직포 섬유를 제조하는 공정에서 방사공정인자와 부직포 특성과의 상관관계를 조사하였다. PP 수지와 Ba-ferrite 분말을 혼합한 후 단축 압출 성형기를 이용하여 펠렛 형태로 제조하고 Melt-blown 섬유 방사기를 이용하여 screw turning force (rpm)와 DCD (die-to-collector distance)를 변화시켜 Ba-ferrite 분말이 부직포 섬유의 기계적, 열적, 결정학적 및 자성 특성에 미치는 영향을 조사하였다. SEM 관찰을 통하여 방사 거리가 증가할수록 혹은 screw turning force가 감소할수록 부직포 섬유의 연신율이 증가하고, 섬유의 직경 및 인장강도가 감소하는 것을 알 수 있었고, XRD 측정 결과로부터 방사거리의 증가는 섬유의 결정성을 높이는 것으로 관찰되었다. 복합 부직포에서는 입자가 고분자와 분리되어 고분자와 입자간의 결합력이 떨어져 순수한 PP대비 인장강도가 감소하였다. Ba-ferrite 분말에 의한 부직포의 자성적 성질을 보면 방사거리에 따라 보자력, 최대 자화, 잔류 자화 값은 감소하였다. TGA 측정을 통한 부직포 섬유의 내열성 시험 결과는 방사거리의 감소에 따라 내열성이 증가하였으며 난연성은 Ba-ferrite 분말의 함량 증가에 따라 증가하였다.

구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구 (Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position)

  • 홍수영;이선기;이진한;이재인
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.101-112
    • /
    • 2023
  • 목적: 구치부 단일 임플란트에서 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 각각의 합병증의 발생률을 후향적으로 조사하는 것이다. 대상 및 방법: 본 연구는 2014년 2월부터 2018년 5월까지 원광대학교 대전치과병원 보철과에서 3명의 보철전문의에게 구치부 단일 치관으로 임플란트 보철 수복을 완료한 환자를 대상으로 하였다. 총 505명의 환자에서 697개의 임플란트를 추적 관찰하였다. 대상 환자의 전자 진료기록부와 방사선 사진을 통해 임플란트의 생존 여부 및 합병증을 기록하였으며 이에 영향을 미칠 수 있는 요인으로 고정체의 직경과 길이, 식립 위치 그리고 환자의 성별, 연령이 평가되었다. 결과: 생존율은 구치부 단일 임플란트의 3년 누적 생존율은 98.5%, 5년 누적 생존율은 94.4% 이었다. 5년 누적 생존율은 직경 4.0 mm 이하(89.5%)일 때보다 4.0 mm 초과(97.0%)일 때 더 높았고, 남성(92.4%)보다 여성(98.8%)에서 더 높았다. 이는 통계적으로 유의한 차이가 있었다 (P < .05). 구치부 단일 임플란트의 기계적 합병증은 20.1%, 생물학적 합병증은 4.7% 발생하였다. 합병증은 지대주 나사 풀림(7.5%), 보철물 탈락(6.3%), 인접면 접촉 상실(3.7%) 순으로 많이 발생하였다. 지대주 나사 풀림은 하악 대구치 부위(10.5%)에서 가장 많이 발생하였고 여성(5.1%)보다 남성(9.5%)에서, 65세 이상(5.1%)보다 65세 미만의 환자(9.4%)에서 더 많이 발생하였다. 이는 통계적으로 유의한 차이가 있었다 (P < .05). 결론: 구치부 단일 임플란트의 5년 누적 생존율은 고정체의 직경이 4.0 mm 이하일 때보다 4.0 mm 초과일 때, 남성보다 여성에서 더 높았다. 가장 많이 발생한 합병증인 지대주 나사 풀림은 하악 대구치 부위에서 가장 많이 발생하였고, 여성보다 남성에서, 65세 이상보다 65세 미만의 환자에서 더 많이 발생하였다. 이는 통계적으로 유의한 차이가 있었다.

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF