• 제목/요약/키워드: Screw connector

검색결과 20건 처리시간 0.024초

5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석 (Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW)

  • 김상철
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석 (Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector)

  • 김상철;김두현;강신욱
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

강화플라스틱 연결구를 이용한 데크의 내력 성능평가 (Strength Performance Evaluation of Deck Using Reinforced Plastic Connector)

  • 송요진;정홍주;이동흡;김경대;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권1호
    • /
    • pp.12-18
    • /
    • 2013
  • 기존의 목재 데크는 보행자의 반복하중으로 못이 인발되어 안전사고가 발생할 우려가 있다. 또한, 데크재와 장선재를 접합 시 접합구에 의하여 목재가 갈라지거나 접합구의 재질에 따라 목재의 부후 속도가 빠르게 진행되는 문제점이 있다. 본 연구에서는 국내 A사에서 개발한 플라스틱 연결구를 사용하여 데크 유닛을 제작, 휨 하중시의 접합내력 성능을 평가하였다. 데크재는 Southern yellow pine (Pinus palustris Miller)을 사용하였다. 접합구의 종류를 달리하여 장선 간 간격(400, 600 mm)에 따른 데크 유닛의 휨 내력 시험을 실시하였다. 시험결과 탄소강 재질의 접합구로 강화플라스틱 연결구에 접합한 시험체의 평균 휨 내력(장선재 간 간격 : 400, 600 mm)이 가장 높게 측정되었으며, 장선재의 폭(40, 50, 70, 80 mm)에 따른 휨 내력 시험 결과 장선재의 폭이 40 mm일때 가장 높은 내력이 측정되었다.

골유착성 임플란트를 중간 지대치로 사용한 고정성 보철물의 응력분석 (A TWO DIMENSIONAL STRESS ANALYSIS OF FIXED PROSTHESIS WITH OSSEOINTEGRATED IMPLANT AS AN INTERMEDIATE ABUTMENT)

  • 박상수;방몽숙
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.611-624
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution of the natural teeth, the implant, the prosthesis and the supporting tissue according to the types of implant and connection modality in the five-unit fixed partial denture with a implant pier abutment. A Two dimensional stress analysis model was constructed to represent a mandible missing the first and second premolars and first molar. The model contained a canine and second molar as abutment teeth and implant pier abutments with and without stress-absorbing element. Finite element models were created and analyzed using software ANSYS 4.4A for IBM 32bit personal computer. The results obtained were as follows. 1. Implant group, compared to the natural teeth group, showed a maximum principal stress at the superior portion of implants and a stress concentration at :he neck and end portion. 2. Maximum principal stress and maximum Von Mises stress were always lower in the case of rigid connection than nonrigid connection. 3. A cylinder type implant with stress absorbing element and screw type implant were generally similar in the stress distribution pattern. 4. A screw type implant, compared to the cylinder type implant, showed a relatively higher stress concentration at both neck and end portion of it. 5. Load B cases showed higher stress concentration on the posterior abutments in the case of nonrigid connector than rigid connector. 6. A maximum displacement was always lower in the case of rigid connection than nonrigid connection. These results suggest that osseointegrated implant can be used as an intermediate abutment.

  • PDF

End Distance of Single-shear Screw Connection in Cross Laminated Timber

  • Oh, Jung-Kwon;Kim, Gwang-Chul;Kim, Kwang-Mo;Lee, Jun-Jae;Hong, Jung-Pyo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.746-752
    • /
    • 2017
  • Cross-laminated timber (CLT) is a relatively new engineered wood for timber construction. It is a great shear wall material. It was known that the shear performance of the CLT wall depends on the performance of connections. In connection, nail or screw has to be installed with a certain distance from the end of the timber. Current building code specifies the distance on the name of end distance. The end distance was decided as a minimum distance not to make splitting or tearing out in lumber or glued laminated timber. As a relatively new engineered wood, the end distance of CLT connection need to be identified because CLT is cross-wisely glued lumber products like plywood. Different from glued laminated timber or lumber, cross layer of CLT may prevent wood from splitting or tearing-out. As a result, the end distance of CLT was expected to be reduced than glued laminated timber. The shorter end distance may let more versatile connector design possible. In this study, prior to developing novel connection for CLT, the end distance of CLT connection was experimentally investigated to identify the end distance limitation. The experiments showed that the end distance can be reduced from 7D to 6D, in case of the tested CLT combination and screw in this study.

Push out tests on various shear connectors used for cold-formed steel composite beam

  • Rajendran, Senthilkumar;Perumalsamya, Jayabalan;Mohanraj, Divya
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.315-323
    • /
    • 2022
  • Shear connectors are key elements that ensure integrity in a composite system. The primary purpose of a shear connector is to bring a high degree of interaction between composite elements. A wide variety of connectors are available for hot-rolled composite construction, connected to the beam through welding. However, with cold-formed members being very thin, welding of shear connectors is not desirable in cold-formed composite constructions. Shear connectors for cold-formed elements are limited in studies as well as in the market. Hence in this study, three different types of shear connectors, namely, single-channel, double channel, and self-tapping screw, were considered, and their performance assessed by the Push-out test as per Eurocode 4. The connection between channel shear connectors and the beam was made using self-tapping screws to avoid welding. The performance of the connectors was analyzed based on their ultimate capacity, characteristic capacity, ductility, and slippage during loading. Strength to weight ratio was also carried out to understand the proposed connectors' suitability for conventional ones. The results showed relatively higher initial stiffness and ductility for double channel connectors than other connectors. Also, self-tapping screws had a higher strength to weight ratio with low ductility.

접합부의 성질을 고려한 볼 접합 단층 래티스 돔의 탄소성 좌굴해석 (The Elasto-Plastic Buckling Analysis of Ball-jointed Sing1e Layer Latticed Domes Considering the Connection Characteristics)

  • 한상을;권현재;신용환;배상달;이진섭
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.90-100
    • /
    • 2000
  • The present paper investigates the elasto-plastic buckling of ball-jointed single layer latticed domes considering the connection characteristics. The domes are composed of tubular member elements, ball joints and connectors. To judge yielding of the member, the ends and central part of tubular member elements are assumed as five elasto-plastic springs. Elasto-plastic buckling load can be identified the yielding load of estimated member As a numerical analysis technique, loading incremental method based on the Newton-Raphson method is used. The effects of connection characteristics are investigated by the following points; (1) the length of rigid zone, (2) looseness of screw, (3) diameter of connector Finally, it is emphasized that the connection characteristics as well as the material non-linearity have significant effects upon the buckling toad of domes.

  • PDF

CLT-콘크리트 합성 거동을 위한 전단 연결재 부재 실험과 해석 연구 (Experimental and Analytical Study of Shear Connectors for the CLT-Concrete Composite Floor System)

  • 박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.65-73
    • /
    • 2019
  • This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is $90^{\circ}$ and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.

치아 및 임플랜트 지지 고정성 국소의치의 비고정성 연결부의 위치에 따른 유한요소법적 응력분석 (A FINITE ELEMENT STRESS ANALYSIS OF TOOTH AND IMPLANT SUPPORTED FIXED PARTIAL DENTURE ACCORDING TO THE LOCATION OF NON-RIGID CONNECTOR)

  • 안병주;황영필;계기성;조규종
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.807-823
    • /
    • 1995
  • The purpose of this study was to analyze the stress distribution and the displacement happened to the abutment, the prosthesis, and the surrounding structure according to the location of the nonrigid connector, that is, the keyway in the distal of canine and the mesial of the implant in the three unit fixed partial denture. Two-dimensional finite element model ws constructed and analyzed for the stress distribution and the displacement using software ABAQUS(Ver 5.2 Hibbitt, Karisson & Sorenson, Inc., 1992). After finishing the finite element model, the distribution load of 15kg was applied simultaneously to the all cusp tips of the prosthesis and the concentration load of 10㎏ was applied respectively at the each cusp tip of the prosthesis. The following results were obtained : 1. The amount of displacement of the implant was greater in case of the non-rigid connection than the rigid connection, and the more favorable displacement was shown in case of the IKb than the IKa. 2. Without regard to the connection method, the stress represented at the surrounding bone was similar, and the more favorabel stress distribution was shown in case of IKb. 3. The maximum stress was concentrated at the fastening screw and the neck of implant in all experimental groups, and their stress magnitudes were in the order of IKb, IR, and IKa.

  • PDF

볼트풀림에 의한 터미널 블록의 접속부 발열 위험성 분석 (Analysis of the Risk of Heat Generation due to Bolt Loosening in Terminal Block Connector Parts)

  • 연영모;김승희
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.67-75
    • /
    • 2020
  • 본 연구는 산업현장에서 사용되는 분전반 내 터미널 블록의 탄화 사고를 예방하기 위한 목적으로, 전선 접속부 볼트의 이상(Abnormal) 풀림 각도에 따라 변화하는 정상전류 및 과전류의 접속부 발열 위험성을 확인하고 열적 특성을 통해 위험성을 분석하였다. 이를 위하여 터미널 블록에 Resistance temperature detector (RTD) 센서 보드를 설치하여 실시간으로 터미널 블록의 발열 온도와 온도의 변화를 측정하는 새로운 기법을 적용하였다. 실험 결과 정격 전류가 작은 터미널 블록 모델의 발열 온도가 높게 나타남에 따라 부하전류에 따른 터미널 블록 용량 선정의 중요성을 확인하였다. 또한 정격전류가 높은 터미널 블록의 정격 전류가 높을수록, 이상 풀림 정도가 클수록 탄화점이 빨라짐을 확인하였다. 이러한 발열 온도 모니터링을 통해서 실시간 발열 온도를 측정할 수 있었고 열적 분석을 통해서 단계별 위험수위 설정이 가능함을 확인할 수 있었다. 본 연구의 탄화 위험성 측정 및 분석 결과는 탄화로 인한 화재 위험성에 대한 응용 연구의 이론적 기초를 제공할 수 있다. 또한 본 연구에서 새롭게 적용한 온도 센서 보드를 활용한 열화 측정 방법은 위험수준관리 및 전기적 접촉 불량으로 인한 화재 예방 활동에 광범위하게 적용 가능할 것으로 사료된다.